Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Am Soc Echocardiogr ; 28(5): 559-69, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25753503

RESUMO

BACKGROUND: Right ventricular (RV) fractional area of change (FAC) is a quantitative two-dimensional echocardiographic measurement of RV function. RV FAC expresses the percentage change in the RV chamber area between end-diastole (RV end-diastolic area [RVEDA]) to end-systole (RV end-systolic area [RVESA]). The objectives of this study were to determine the maturational (age- and weight-related) changes in RV FAC and RV areas and to establish reference values in healthy preterm and term neonates. METHODS: A prospective longitudinal study was conducted in 115 preterm infants (23-28 weeks' gestational age at birth, 500-1,500 g). RV FAC was measured at 24 hours of age, 72 hours of age, and 32 and 36 weeks' postmenstrual age (PMA). The maturational patterns of RVEDA, RVESA, and RV FAC were compared with those in 60 healthy full-term infants in a cross-sectional study (≥37 weeks, 3.5 ± 1 kg), who underwent echocardiography at birth (n = 25) and 1 month of age (n = 35). RVEDA and RVESA were traced in the RV-focused apical four-chamber view, and FAC was calculated using the formula 100 × [(RVEDA - RVESA)/RVEDA)]. Premature infants who developed chronic lung disease or had clinically and hemodynamically significant patent ductus arteriosus were excluded (n = 55) from the reference values. Intra- and interobserver reproducibility analysis was performed. RESULTS: RV FAC ranged from 26% at birth to 35% by 36 weeks' PMA in preterm infants (n = 60) and increased almost 2 times faster in the first month of age compared with healthy term infants (n = 60). Similarly, RVEDA and RVESA increased throughout maturation in both term and preterm infants. RV FAC and RV areas were correlated with weight (r = 0.81, P < .001) but were independent of gestational age at birth (r = 0.3, P = .45). RVEDA and RVESA were correlated with PMA in weeks (r = 0.81, P < .001). RV FAC trended lower in preterm infants with bronchopulmonary dysplasia (P = .04) but was not correlated with size of patent ductus arteriosus (P = .56). There was no difference in RV FAC based on gender or need for mechanical ventilation. CONCLUSIONS: This study establishes reference values of RV areas (RVEDA and RVESA) and RV FAC in healthy term and preterm infants and tracks their maturational changes during postnatal development. These measures increase from birth to 36 weeks' PMA, and this is reflective of the postnatal cardiac growth as a contributor to the maturation of cardiac function These measures are also linearly associated with increasing weight throughout maturation. This study suggests that two-dimensional RV FAC can be used as a complementary modality to assess global RV systolic function in neonates and facilitates its incorporation into clinical pediatric and neonatal guidelines.


Assuntos
Permeabilidade do Canal Arterial/fisiopatologia , Ecocardiografia/métodos , Recém-Nascido Prematuro/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Direita/fisiologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Feminino , Seguimentos , Idade Gestacional , Ventrículos do Coração/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes
2.
J Pediatr ; 166(3): 660-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25556013

RESUMO

OBJECTIVES: To test our hypothesis that obese adolescents have left ventricular (LV) dysfunction and remodeling that are associated with markers of cardiovascular risk and insulin resistance (IR). STUDY DESIGN: In a cross-sectional study of 44 obese and 14 lean age-, sex-, Tanner stage-, and race-matched adolescents, IR, markers of cardiovascular risks, conventional and 2-dimensional speckle tracking echocardiography measures of LV function and structure were evaluated and compared. RESULTS: The obese adolescents had significantly increased body mass index Z-score, systolic blood pressure, fasting insulin, IR, and atherogenic lipids compared with the lean adolescents. A subgroup of obese adolescents had LV remodeling characterized by significantly increased LV mass index (g/m(2.7)) and relative wall thickness. Almost all obese adolescents had LV dysfunction with peak LV global longitudinal strain (GLS, %), systolic GLS rate (GLSR, %/s), and early diastolic GLSR significantly lower than in lean adolescents and in the normal pediatric population. Body mass index Z-score predicted LV remodeling (LV mass index [R(2) = 0.34] and relative wall thickness [R(2) 0.10]), and peak LV GLS (R(2) 0.15), and along with systolic blood pressure, predicted systolic GLSR (R(2) 0.16); (P ≤ .01 for all). Fasting insulin predicted early diastolic GLSR (R(2) 0.17, P ≤ .01). CONCLUSIONS: Obese adolescents have subclinical ventricular dysfunction associated with the severity of obesity, increased systolic blood pressure, and IR. Ventricular remodeling is present in a subgroup of obese adolescents in association with the severity of obesity. These findings suggest that obesity may have an early impact on the cardiovascular health of obese adolescents.


Assuntos
Biomarcadores/sangue , Índice de Massa Corporal , Resistência à Insulina , Obesidade Infantil/complicações , Disfunção Ventricular Esquerda/etiologia , Adolescente , Doenças Cardiovasculares/sangue , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/etiologia , Criança , Estudos Transversais , Ecocardiografia , Feminino , Humanos , Incidência , Masculino , Obesidade Infantil/sangue , Obesidade Infantil/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Estados Unidos/epidemiologia , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/fisiopatologia
3.
Echocardiography ; 32(5): 839-47, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25109389

RESUMO

BACKGROUND: Frame rate (FR) of image acquisition is an important determinant of the reliability of 2-dimensional speckle tracking echocardiography (2DSTE)-derived myocardial strain. Premature infants have relatively high heart rates (HR). The aim was to analyze the effects of varying FR on the reproducibility of 2DSTE-derived right ventricle (RV) and left ventricle (LV) longitudinal strain (LS) and strain rate (LSR) in premature infants. METHODS: RV and LV LS and LSR were measured by 2DSTE in the apical four-chamber view in 20 premature infants (26 ± 1 weeks) with HR 163 ± 13 bpm. For each subject, 4 sets of cine loops were acquired at FR of <90, 90-110, 110-130, and >130 frames/sec. Two observers measured LS and LSR. Inter- and intra-observer reproducibility was assessed using Bland-Altman analysis, coefficient of variation, and linear regression. RESULTS: Intra-observer reproducibility for RV and LV LS was higher at FR >110 frames/sec, and optimum at FR >130 frames/sec. The highest inter-observer reproducibility for RV and LV LS were at FR >130 and >110 frames/s, respectively. The highest reproducibility for RV and LV systolic and early diastolic LSR was at FR >110 frames/sec. FR/HR ratio >0.7 frames/sec per bpm yielded optimum reproducibility for RV and LV deformation imaging. CONCLUSIONS: The reliability of 2DSTE-derived RV and LV deformation imaging in premature infants is affected by the FR of image acquisition. Reproducibility is most robust when cine loops are obtained with FR/HR ratio between 0.7 and 0.9 frames/sec per bpm, which likely results from optimal myocardial speckle tracking and mechanical event timing.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Recém-Nascido Prematuro , Feminino , Humanos , Recém-Nascido , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia
4.
J Am Soc Echocardiogr ; 27(2): 163-71, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24183542

RESUMO

BACKGROUND: Doppler echocardiography (DE) is widely used as a surrogate for right heart catheterization (RHC), the gold standard, to assess and monitor elevated right heart pressure in children. However, its accuracy has not been prospectively validated in children. The objectives of this study were to evaluate the accuracy of DE in predicting simultaneously measured right ventricular (RV) pressure by RHC in pediatric patients and to determine if the degree of RV hypertension affects the accuracy of DE in assessing right heart pressure. METHODS: Eighty children (age range, 0-17.9 years; median age, 5.5 years) with two-ventricle physiology and a wide range of right heart pressures underwent simultaneous DE and RHC. The pressure gradient between the right ventricle and the right atrium was directly measured by RHC and simultaneously estimated by DE using tricuspid regurgitation. Patients were then grouped on the basis of RHC-measured RV systolic pressure (RVSP): group 1 (n = 43), with RVSP < 1/2 systemic systolic blood pressure (SBP); group 2 (n = 37), with RVSP ≥ 1/2 SBP; group 3 (n = 56), with RVSP < 2/3 SBP; and group 4 (n = 24), with RVSP ≥ 2/3 SBP. Correlation and Bland-Altman analyses were performed on all groups. Accuracy was predefined as 95% limits of agreement within ±10 mm Hg. RESULTS: Despite a reasonable correlation between DE and RHC in all groups, there was poor agreement between techniques as RVSP/SBP increased. DE was inaccurate in one of 43 patients in group 1 (2%) versus nine of 37 in group 2 (24%) and was inaccurate in one of 56 patients in group 3 (2%) versus eight of 24 in group 4 (33%). Overestimation and underestimation occurred equally in all groups. CONCLUSION: DE inaccurately estimates RV pressure in children with elevated right heart pressure. It should not be relied on as the sole method of assessing right heart hemodynamics in children with RV hypertension.


Assuntos
Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/normas , Ecocardiografia Doppler , Cardiopatias/complicações , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Pressão Ventricular , Adolescente , Cateterismo Cardíaco , Criança , Pré-Escolar , Precisão da Medição Dimensional , Feminino , Humanos , Hipertensão/etiologia , Lactente , Masculino , Erros Médicos , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Função Ventricular Direita/fisiologia
5.
J Am Soc Echocardiogr ; 26(10): 1201-1213, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23880052

RESUMO

BACKGROUND: Right ventricular (RV) systolic function is an important prognostic determinant of cardiopulmonary pathologies in premature infants. Measurements of dominant RV longitudinal deformation are likely to provide a sensitive measure of RV function. An approach for image acquisition and postacquisition processing is needed for reliable and reproducible measurements of myocardial deformation by two-dimensional (2D) speckle-tracking echocardiography. The aims of this study were to determine the feasibility and reproducibility of 2D speckle-tracking echocardiographic measurement of RV peak global longitudinal strain (pGLS) and peak global longitudinal strain rate in premature infants and to establish methods for acquiring and analyzing strain. METHODS: The study was designed in two phases: (1) a training phase to develop methods of image acquisition and postprocessing in a cohort of 30 premature infants (born at 28 ± 1 weeks) and (2) a study phase to prospectively test in a separate cohort of 50 premature infants (born at 27 ± 1 weeks) if the methods improved the feasibility and reproducibility of RV pGLS and peak global longitudinal strain rate measurements to a clinically significant level, assessed using Bland-Altman analysis (bias, limits of agreement, coefficient of variation, and intraclass correlation coefficient). RESULTS: Strain imaging was feasible from 84% of the acquisitions using the methods developed for optimal speckle brightness and frame rate for RV-focused image acquisition. There was high intraobserver (bias, 3%; 95% limits of agreement, -1.6 to +1.6; coefficient of variation, 2.7%; intraclass correlation coefficient, 0.97; P = .02) and interobserver (bias, 7%; 95% limits of agreement, -4.8 to +4.73; coefficient of variation, 3.9%; intraclass correlation coefficient, 0.93; P < .05) reproducibility, with excellent linear correlation between the two pGLS measurements (r = 0.97 [P < .01] and r = 0.93 [P < .05], respectively). CONCLUSIONS: This study demonstrates high clinical feasibility and reproducibility of RV pGLS and RV peak global longitudinal strain rate measurements by 2D speckle-tracking echocardiography in premature infants and offers methods for image acquisition and data analysis for systolic strain imaging that can provide a reliable assessment of global RV function.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Recém-Nascido Prematuro , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Recém-Nascido , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sístole/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA