Pract Lab Med ; 38: e00347, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38188654

RESUMO

Background: Vitamin D (vit-D) deficiency is highly prevalent in the Korean population, highlighting the need for accurate measurements. In this study, the interferences by endogenous and cross-reactive substances were compared between routine vit-D immunoassays and mass spectrometry (MS) methods. Methods: Two MS methods and 4 immunoassays from different manufacturers (Abbott, Beckman Coulter, Roche, Siemens) were compared. Residual samples that were icteric, lipemic, hemolyzed, high in rheumatoid factor, from myeloma patients, or patients undergoing hemodialysis were collected. Also, 4 levels of National Institute of Standards and Technology (NIST) Standard Reference Material 972a, and 12 samples serially spiked with 3-epi-25-OH-D3 were prepared. Results: Significant interferences were observed in hemolytic (Roche), icteric (Beckman and Siemens) and lipemic samples (all 4 immunoassays). Level 4 NIST material and 3-epi-25-OH-D3-spiked samples induced significant cross-reactivity, yielding higher total vit-D measurements in non-epimer-separating MS methods, and both the Beckman and Roche immunoassays. Conclusion: Most observed interferences were consistent with manufacturers' claims, but overall improvement of immunoassay bias limits is required. Awareness of potential interference is important to increase the accuracy of vit-D measurements. Moreover, care is due when interpreting vit-D results of newborns, infants and less commonly, pregnant women, who are known to have physiologically high levels of the highly cross-reactive 3-epi-25-OH-D3.

2.
Diagnostics (Basel) ; 14(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38275478

RESUMO

We evaluated the diagnostic performance of the STANDARD i-Q COVID-19 Ag Test, which was developed to detect viral antigens, using nasal and oral swabs. Sixty positive and 100 negative samples were analyzed. We determined the distribution of the Ct values according to the day of sample collection after symptom onset, the diagnostic performance of the total samples and subgroups separated by Ct value or time of sample collection, and the Ct value at which maximal accuracy was expected. No differences were observed in Ct values, except for the samples obtained on the day of symptom onset. The diagnostic sensitivity and specificity of the oral swabs were 75.0 and 100.0%, respectively, whereas those of the nasal swabs were 85.0 and 98.0%, respectively. The sensitivity was higher in samples with a high viral load collected earlier than those collected later, although the difference was not significant. False-negative results were confirmed in all samples with a Ct value ≥ 30.0. These results indicate that tests using oral and nasal swabs are helpful for diagnosing acute symptomatic cases with suspected high viral loads. Our tests exhibited relatively low sensitivity but high specificity rates, indicating the need to assess negative antigen test results.

3.
Ann Lab Med ; 43(3): 290-294, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36544341

RESUMO

While numerous studies have evaluated humoral responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines, data on the cellular responses to these vaccines remain sparse. We evaluated T cell responses to ChAdOx1-nCoV-19 and BNT162b2 vaccinations using an interferon gamma (IFN-γ) release assay (IGRA). ChAdOx1-nCoV-19- and BNT162b2-vaccinated participants initially showed stronger T cell responses than unvaccinated controls. The T cell response decreased over time and increased substantially after the administration of a BNT162b2 booster dose. Changes in the T cell response were less significant than those in the anti-receptor-binding domain IgG antibody titer. The study results can serve as baseline data for T cell responses after SARS-CoV-2 vaccination and suggest that the IGRA can be useful in monitoring immunogenicity.


Assuntos
COVID-19 , ChAdOx1 nCoV-19 , Humanos , Vacina BNT162 , Vacinas contra COVID-19 , COVID-19/prevenção & controle , SARS-CoV-2 , Vacinação , Anticorpos Antivirais
4.
Front Genet ; 13: 836970, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35664336

RESUMO

Background: Statins are the most popular agents for the primary and secondary prevention of cardiovascular disease; however, the pharmacokinetic parameters and associated genetic factors in the Korean population have not been fully elucidated. This study explored the pharmacokinetic properties of atorvastatin and the association between genetic variations and atorvastatin pharmacokinetics in healthy Korean subjects. Methods: Atorvastatin (80 mg) was administered to 35 healthy Korean volunteers. Plasma levels of atorvastatin and its metabolites were measured sequentially using liquid chromatography-tandem mass spectrometry from 0 to 24 h after atorvastatin administration. Customized next-generation sequencing analysis was performed covering all coding exons of 15 genes, as well as 46 single-nucleotide variants in 29 genes related to statin pharmacokinetics. Results: The mean area under the concentration-time (AUC) and Cmax (maximum peak concentration) were 269.0 ng/ml∙h and 84.3 ng/ml, respectively, which were approximately two times higher than those reported in Caucasians. Genetic analysis revealed that eight genetic variants in ABCB1, ABCG2, APOA5, CETP, and CYP7A1 contributed to the AUC of atorvastatin. The atorvastatin AUC0-24 h prediction model was developed based on age and eight genetic variants using multivariate linear regression (adjusted R 2 = 0.878, p < 0.0001). Conclusion: This study shows that the pharmacokinetic properties of atorvastatin in Koreans are different from those in Caucasians and that atorvastatin AUC0-24 h could be predicted based on age and eight genetic variants of ABCB1, ABCG2, APOA5, CETP, and CYP7A1.

5.
Diagnostics (Basel) ; 12(6)2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35741159

RESUMO

BACKGROUND: Immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) wanes over time after vaccination. METHODS: We compared SARS-CoV-2 antibody levels in serial samples from 350 vaccinated individuals at 3 time points (3 weeks after the first or second dose and before the third dose) with 4 assays: GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS), Siemens SARS-CoV-2 IgG (sCOVG), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II), and an Immuno-On™ COVID-19 IgG test (Immuno-On IgG). Antibody levels by time, concordance between assays, and values from other tests corresponding to the percent inhibition results in cPASS were assessed. RESULTS: The median values at three time points were 49.31%, 90.87%, and 53.38% inhibition for cPASS, 5.39, 13.65, and 2.24 U/mL for sCOVG, 570.25, 1279.65, and 315.80 AU/mL for CoV-2 IgG II, and 223.22, 362.20, and 62.20 relative units (RU) for Immuno-On IgG. The concordance with cPASS at each time point ranged from 0.735 to 0.984, showing the highest concordance in the second sample and lowest concordance in the third in all comparative tests. The values corresponded to 30% inhibition, and the cutoffs of cPASS, were 2.02 U/mL, 258.6 AU/mL, and 74.2 RU for each test. Those for 50%, 70%, and 90% inhibition were 3.16, 5.66, and 8.26 U/mL for sCOVG, while they were 412.5, 596.9, and 1121.6 AU/mL for CoV-2 IgG II and 141.8, 248.92, and 327.14 RU for Immuno-On IgG. CONCLUSIONS: This study demonstrated the dynamic changes in antibody values at different time points using four test systems and is expected to provide useful baseline data for comparative studies and standardization efforts in the future.

6.
Microbiol Spectr ; 9(3): e0120221, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34817223

RESUMO

Multiple vaccines against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have been developed and administered to mitigate the coronavirus disease 2019 (COVID-19) pandemic. We assessed the humoral response of BNT162b2 and ChAdOx1 nCoV-19 using Siemens SARS-CoV-2 IgG (sCOVG; cutoff of ≥1.0 U/ml), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; cutoff of ≥50.0 AU/ml), and GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS; cutoff of ≥30% inhibition). We collected 710 serum samples (174 samples after BNT162b2 and 536 samples after ChAdOx1 nCoV-19). Venous blood was obtained 3 weeks after first and second vaccinations. In both vaccines, sCOVG, CoV-2 IgG II, and cPASS showed a high seropositive rate (>95.7%) except for cPASS after the first vaccination with ChAdOx1 nCoV-19 (68.8%). Using sCOVG and CoV-2 IgG II, the ratios of antibody value (second/first) increased 10.6- and 11.4-fold in BNT162b2 (first 14.1, second 134.8 U/ml; first 1,416.2, second 14,326.4 AU/ml) and 2.3- and 2.0-fold in ChAdOx1 nCoV-19 (first 4.0, second 9.1 U/ml; first 431.0, second 9,744.0 AU/ml). cPASS-positive results indicated a very high concordance rate with sCOVG and CoV-2 IgG II (>98%), whereas cPASS-negative results showed a relatively low concordance rate (range of 22.2% to 66.7%). To predict cPASS positivity, we suggested additional cutoffs for sCOVG and CoV-2 IgG II at 2.42 U/ml and 284 AU/ml, respectively. In conclusion, BNT162b2 and ChAdOx1 nCoV-19 evoked robust humoral responses. sCOVG and CoV-2 IgG II showed a very strong correlation with cPASS. sCOVG and CoV-2 IgG II may predict the presence of neutralizing antibodies against SARS-CoV-2. IMPORTANCE The Siemens severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) IgG (sCOVG; Siemens Healthcare Diagnostics Inc., NY, USA) and Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II; Abbott Laboratories, Sligo, Ireland), which are automated, quantitative SARS-CoV-2-binding antibody assays, have been recently launched. This study aimed to evaluate the humoral immune response of BNT162b2 and ChAdOx1 nCoV-19 vaccines using sCOVG and CoV-2 IgG II and compare the quantitative values with the results of the GenScript surrogate virus neutralization test (cPASS; GenScript, USA Inc., NJ, USA). Our findings demonstrated that both BNT162b2 and ChAdOx1 nCoV-19 elicited a robust humoral response after the first vaccination and further increased after the second vaccination. sCOVG and CoV-2 IgG II showed a strong correlation, and the concordance rates among sCOVG, CoV-2 IgG II, and cPASS were very high in the cPASS-positive results. The additional cutoff sCOVG and CoV-2 IgG II could predict the results of cPASS.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Vacinas contra COVID-19/imunologia , COVID-19/imunologia , Imunidade Humoral , Vacinação , Adulto , Vacina BNT162/imunologia , COVID-19/prevenção & controle , ChAdOx1 nCoV-19/imunologia , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , SARS-CoV-2 , Testes Sorológicos/métodos , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto Jovem
7.
Ann Clin Biochem ; 58(5): 468-473, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33940935

RESUMO

BACKGROUND: The type of blood collection tube affects specimen quality and laboratory results. Because plasma specimens have a shorter processing time compared with serum specimens, emergency biochemistry tests use plasma. However, serum specimens remain stable after centrifugation and show more accurate results than plasma. Therefore, a quick-clotting serum separator tube is expected to be useful for shorter turnaround times and accurate results. We evaluated a new quick-clotting serum separator tube VQ-Tube™ (AB Medical, Korea) for clinical chemistry and thyroid hormone assays. METHODS: One hundred volunteers from four university hospitals were recruited, and peripheral blood samples were collected in quick-clotting serum separator tube VQ-Tubes™ and the commonly used serum separator tube V-Tubes™. The obtained specimens were used for 16 clinical chemistry assays and three thyroid hormone assays. RESULTS: The differences (%) in the test results obtained from the samples in each tube satisfied the allowable difference ranges (19 assays). The differences in the test results between the tubes satisfied the desired specifications for accuracy except for the glucose results (2.75%). The paired t-test revealed significant differences between the results of six assays, but each set of results showed a good correlation. Samples were visually inspected for serum clarity and gel barrier integrity, and incomplete clotting reactions and haemolysed serum were not observed. CONCLUSIONS: The new quick-clotting VQ-Tube™ demonstrated reliable test results compared with the commonly used serum separator tube V-Tube™. This quick-clotting tube will provide fast test results with adequately separated serum specimens, especially for patients who need fast tests.


Assuntos
Coleta de Amostras Sanguíneas/instrumentação , Hormônios Tireóideos/sangue , Adulto , Química Clínica/instrumentação , Química Clínica/métodos , Feminino , Humanos , Masculino
8.
Ann Lab Med ; 41(2): 155-170, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33063677

RESUMO

BACKGROUND: Reference intervals defined for adults or children of other ethnicities cannot be applied in the evaluation of Korean pediatric patients. Pediatric reference intervals are difficult to establish because children are in their growing stage and their physiology changes continuously. We aimed to establish reference intervals for routine laboratory tests for Korean pediatric patients through retrospective multicenter data analysis. METHODS: Preoperative laboratory test results from 1,031 pediatric patients aged 0 month-18 years who underwent minor surgeries in four university hospitals were collected. Age- and sex-specific reference intervals for routine laboratory tests were defined based on the Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. RESULTS: The pediatric reference intervals determined in this study were different from existing adult reference intervals and pediatric reference intervals for other ethnicities. Most tests required age-specific partitioning, and some of those required sex-specific partitioning for at least one age-partitioned subgroup. Erythrocyte sedimentation rate, monocyte percentage, basophil percentage, activated partial thromboplastin time, glucose, cholesterol, albumin, bilirubin, chloride, and C-reactive protein did not show any difference between age- or sex-partitioned subgroups. CONCLUSIONS: We determined Korean pediatric reference intervals for hematology, coagulation, and chemistry tests by indirect sampling based on medical record data from multiple institutions. These reference intervals would be valuable for clinical evaluations in the Korean pediatric population.


Assuntos
Testes Diagnósticos de Rotina/normas , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , República da Coreia , Estudos Retrospectivos
9.
Pract Lab Med ; 22: e00185, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33204790

RESUMO

INTRODUCTION: Accurate, precise and reliable laboratory test results play a critical role in medical decision making. To satisfy the increasing needs in clinical laboratory tests, the analyzers have been advanced. In this study, authors aimed to evaluate the analytical performance of the Alinity i system (Abbott Laboratories, IL, USA) for diverse analytes measured by using immunoassay principle. MATERIALS AND METHODS: Analytical performance of recently launched Alinity i system has been evaluated for 31 assays in aspects of precision, linearity and analytical measurement range, correlation with the Architect i2000sr system (Abbott Laboratories), carry-over, and reference interval validation in accordance with CLSI guidelines. RESULTS: The within-laboratory CVs of the analytes tested in the study ranged between 1.00 and 7.84%, which met vendor claimed value in precision. In linearity test, most assays satisfied acceptable linearity criteria, best-fit first order regression or polynomial regression with nonlinearity smaller than ±10%, compared with linear regression. The recovery of each analyte distributed from 90.1 to 109.7%. The coefficient of determination (R2) for each test was larger than 0.95 except for folate when compared to the results obtained from existing routine analyzer and statistically or clinically equivalent. The carry-over rates were acceptable, and reference intervals were validated. CONCLUSION: Through this study, acceptable analytical performance of novel Alinity i system has been verified. It is expected to readily replace existing instrument and to be an option for laboratories considering introduction of automated immunoassay analyzer.

10.
J Korean Med Sci ; 35(24): e231, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32567262

RESUMO

There have been controversies on the prophylactic effect of hydroxychloroquine against severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). We describe a patient, 60-year old Korean woman, with coronavirus disease 2019 (COVID-19) who had been taking hydroxychloroquine for 6 months. Her serum and saliva concentrations of hydroxychloroquine were 280 µg/L and 4,890 µg/L, respectively. The present case raises concerns on hydroxychloroquine's role as a prophylactic agent for COVID-19.


Assuntos
Antivirais/uso terapêutico , Betacoronavirus/efeitos dos fármacos , Infecções por Coronavirus/tratamento farmacológico , Infecções por Coronavirus/prevenção & controle , Hidroxicloroquina/uso terapêutico , Pandemias/prevenção & controle , Pneumonia Viral/tratamento farmacológico , Pneumonia Viral/prevenção & controle , Monofosfato de Adenosina/análogos & derivados , Monofosfato de Adenosina/uso terapêutico , Alanina/análogos & derivados , Alanina/uso terapêutico , Azitromicina/uso terapêutico , COVID-19 , Feminino , Humanos , Pessoa de Meia-Idade , Prevenção Primária/métodos , SARS-CoV-2
11.
J Clin Lab Anal ; 34(11): e23504, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33463769

RESUMO

BACKGROUND: Hemoglobin A1c (HbA1c) is arguably the most important biomarker used in the diagnosis and treatment monitoring of diabetes mellitus. We evaluated the analytical performance of the Norudia HbA1c assay (Sekisui Medical Co., LTD), which uses an enzymatic method incorporated into a fully automated, high-throughput system. METHODS: The precision, linearity, and carryover of the Norudia HbA1c assay were evaluated. Using 60 patient samples, comparative analysis of HbA1c measurements with two commonly used HbA1c assays, the D100 (Bio-Rad Laboratories, Inc) and HLC-723 G11 (Tosoh), was undergone. Thirteen commutable samples with known HbA1c concentrations measured using an IFCC reference measurement procedure were used to compare accuracy between methods. Interference of HbA1c measurement by Hb variants was evaluated using 16 known Hb variant samples. RESULTS: Repeatability (% CV) for low and high concentrations ranged from 1.12%-1.50% and 0.66%-0.75%, respectively, and within-laboratory precision for low and high concentrations ranged from 1.73%-2.89% and 0.98%-1.64%, respectively. For linearity, the coefficient of determination was 0.9987. No significant carryover was observed. When compared to the D100 and HLC-723 G11 assays, the Norudia HbA1c assay showed the best accuracy with the lowest mean bias (-1.72%). Furthermore, the Norudia was least affected by Hb variants and gave the most reliable HbA1c measurements. CONCLUSION: The Norudia HbA1c showed excellent analytical performance with good precision and linearity, and minimal carryover. When compared to other routine HbA1c methods, the Norudia HbA1c assay showed the highest accuracy and was least affected by Hb variants.


Assuntos
Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Hemoglobinas Glicadas/análise , Humanos , Modelos Lineares , Reprodutibilidade dos Testes
12.
Clin Appl Thromb Hemost ; 25: 1076029618825310, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30808222

RESUMO

Although portal vein thrombosis (PVT) commonly occurs in patients with hepatocellular carcinoma (HCC), the hypercoagulability mechanism in patients with HCC is not entirely clear. Recently, tumor-induced formation of neutrophil extracellular traps (NET) has been shown to trigger contact system activation, and contact system activation has been shown to be a new mechanism of thrombosis. Therefore, we investigated whether contact system activation and NET formation occurred in relation to PVT in HCC patients. The circulating levels of NET formation markers (DNA-histone complex, double-stranded DNA, neutrophil elastase) and contact system activation markers (factor XIIa and high-molecular-weight kininogen) were measured in 177 patients who had been diagnosed with HCC and 48 healthy controls. Presence of PVT was confirmed in 77 HCC patients. The levels of NET formation and contact system activation markers were significantly higher in patients than in healthy controls and they increased significantly with the increase in the model for end-stage liver disease (MELD) scores. Of note, these markers were significantly higher in HCC patients with PVT than in those without PVT. These NET formation markers and the contact system activation markers were significant thrombotic risk factors in HCC patients. The well-known liver injury markers (alanine transaminase, prothrombin time) significantly contributed to factor XIIa level. Contact system activation and NET formation are well correlated with liver disease severity and the markers of these can be used as thrombotic risk factors in HCC patients. In addition, therapeutics inhibiting the contact system can be potentially used to manage PVT in HCC patients.


Assuntos
Carcinoma Hepatocelular/complicações , Armadilhas Extracelulares/metabolismo , Neoplasias Hepáticas/complicações , Neutrófilos/metabolismo , Trombose Venosa/etiologia , Adulto , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Veia Porta/patologia , Fatores de Risco , Trombose Venosa/patologia