Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 33(4): e4453, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30517974

RESUMO

A single LC-MS/MS assay has been developed and validated for the simultaneous determination of metformin and dapagliflozin in human plasma using ion-pair solid-phase extraction. Chromatographic separation of the analytes and their internal standards was carried out on a reversed-phase ACE 5CN (150 × 4.6 mm, 5 µm) column using acetonitrile-15 mm ammonium acetate, pH 4.5 (70:30, v/v) as the mobile phase. To achieve higher sensitivity and selectivity for the analytes, mass spectrometric analysis was performed using a polarity switching approach. Ion transitions studied using multiple reaction monitoring mode were m/z 130.1 [M + H]+ /60.1 for metformin and m/z 467.1 [M + CH3 COO]- /329.1 for dapagliflozin in the positive and negative modes, respectively. The linear calibration range of the assay was established from 1.00 to 2000 ng/mL for metformin and from 0.10 to 200 ng/mL for dapagliflozin to achieve a better assessment of the pharmacokinetics of the drugs. The limit of detection and limit of quantitation for the analytes were 0.39 and 1.0 ng/mL for metformin and 0.03 and 0.1 ng/mL for dapagliflozin, respectively. There was no interference of plasma matrix obtained from different sources, including hemolyzed and lipemic plasma. The method was successfully applied to study the effect of food on the pharmacokinetics of metformin and dapagliflozin in healthy subjects.


Assuntos
Compostos Benzidrílicos/sangue , Compostos Benzidrílicos/farmacocinética , Cromatografia Líquida/métodos , Glucosídeos/sangue , Glucosídeos/farmacocinética , Metformina/sangue , Metformina/farmacocinética , Espectrometria de Massas em Tandem/métodos , Adulto , Compostos Benzidrílicos/química , Feminino , Glucosídeos/química , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Metformina/química , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
2.
J Pharm Anal ; 7(3): 163-169, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29404033

RESUMO

A sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for the simultaneous determination of lisinopril (LIS) and hydrochlorothiazide (HCTZ) in human plasma using their labeled internal standards (ISs). Sample pre-treatment involved solid phase extraction on Waters Oasis HLB cartridges using 100 µL of plasma, followed by liquid chromatography on Hypersil Gold C18 (50 mm×3.0 mm, 5 µm) column. The analytes were eluted within 2.0 min using acetonitrile-5.0 mM ammonium formate, pH 4.5 (85:15, v/v) as the mobile phase. The analytes and ISs were analyzed in the negative ionization mode and quantified using multiple reaction monitoring. The method showed excellent linearity over the concentration range of 0.50-250.0 ng/mL for both the analytes. The intra-batch and inter-batch precision (% CV) was ≤5.26% and their extraction recoveries were in the range of 96.6%-103.1%. Matrix effect evaluated in terms of IS-normalized matrix factors ranged from 0.97 to 1.03 for both the analytes. The validated method was successfully applied to determine the plasma concentration of the drugs using 10 mg lisinopril and 12.5 mg hydrochlorothiazide fixed dose formulation in 18 healthy Indian volunteers.

3.
J Pharm Anal ; 7(5): 288-296, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29404051

RESUMO

A selective, sensitive and precise assay based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the simultaneous determination of amiloride (AMI) and hydrochlorothiazide (HCTZ) in human plasma. Sample clean-up with 250 µL of plasma was done on Phenomenex Strata™-X extraction cartridges using their labeled internal standards (AMI-15N3 and HCTZ-13C,d2). Chromatography was performed on Hypersil Gold C18 (50 mm×3.0 mm, 5 µm) column using acetonitrile with 4.0 mM ammonium formate (pH 4.0, adjusted with 0.1% formic acid) (80:20, v/v) as the mobile phase. Detection was carried out on a triple quadrupole API 5500 mass spectrometer utilizing an electrospray ionization interface and operating in the positive ionization mode for AMI and negative ionization mode for HCTZ. Multiple reaction monitoring was used following the transitions at m/z 230.6/116.0, m/z 233.6/116.0, m/z 296.0/204.9 and m/z 299.0/205.9 for AMI, AMI-15N3, HCTZ and HCTZ-13C,d2, respectively. Calibration curves were linear (r2≥0.9997) over the concentration range of 0.050-50.0 and 0.50-500 ng/mL for AMI and HCTZ, respectively, with acceptable accuracy and precision. The signal-to-noise ratio at the limit of quantitation was ≥14 for both the analytes. The mean recovery of AMI and HCTZ from plasma was 89.0% and 98.7%, respectively. The IS-normalized matrix factors determined for matrix effect ranged from 0.971 to 1.024 for both the analytes. The validated LC-MS/MS method was successfully applied to a bioequivalence study using 5 mg AMI and 50 mg HCTZ fixed dose tablet formulation in 18 healthy Indian volunteers with good reproducibility.

4.
J Pharm Anal ; 7(5): 309-316, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29404054

RESUMO

A sensitive and selective method has been proposed for the simultaneous determination of amlodipine (AML), valsartan (VAL) and hydrochlorothiazide (HCTZ) in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The analytes and their deuterated analogs were quantitatively extracted from 100 µL human plasma by solid phase extraction on Oasis HLB cartridges. The chromatographic separation of the analytes was achieved on a Chromolith RP18e (100 mm × 4.6 mm) analytical column within 2.5 min. The resolution factor between AML and VAL, AML and HCTZ, and VAL and HCTZ was 2.9, 1.5 and 1.4, respectively, under isocratic conditions. The method was validated over a dynamic concentration range of 0.02-20.0 ng/mL for AML, 5.00-10,000 ng/mL for VAL and 0.20-200 ng/mL for HCTZ. Ion-suppression/enhancement effects were investigated by post-column infusion technique. The mean IS-normalized matrix factors for AML, VAL and HCTZ were 0.992, 0.994 and 0.998, respectively. The intra-batch and inter-batch precision (% CV) across quality control levels was ≤ 5.56% and the recovery was in the range of 93.4%-99.6% for all the analytes. The method was successfully applied to a bioequivalence study of 5 mg AML + 160 mg VAL + 12.5 mg HCTZ tablet formulation (test and reference) in 18 healthy Indian males under fasting. The mean log-transformed ratios of Cmax, AUC0-120h and AUC0-inf and their 90% CIs were within 90.2%-102.1%. The assay reproducibility was demonstrated by reanalysis of 90 incurred samples.

5.
Biomed Chromatogr ; 31(3)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27508356

RESUMO

A specific and rapid liquid chromatography-tandem mass spectrometry method is proposed for the simultaneous determination of metformin (MET), saxagliptin (SAXA) and its active metabolite, 5-hydroxy saxagliptin (5-OH SAXA) in human plasma. Sample preparation was accomplished from 50 µL plasma sample by solid-phase extraction using sodium dodecyl sulfate as an ion-pair reagent. Reversed-phase chromatographic resolution of analytes was possible within 3.5 min on ACE 5CN (150 × 4.6 mm, 5 µm) column using acetonitrile and10.0 mm ammonium formate buffer, pH 5.0 (80:20, v/v) as the mobile phase. Triple quadrupole mass spectrometric detection was performed using electrospray ionization in the positive ionization mode. The calibration curves showed good linearity (r2 ≥ 0.9992) over the established concentration range with limit of quantification of 1.50, 0.10 and 0.20 ng/mL for MET, SAXA and 5-OH SAXA respectively. The extraction recoveries obtained from spiked plasma samples were highly consistent for MET (75.12-77.84%), SAXA (85.90-87.84%) and 5-OH SAXA (80.32-82.69%) across quality controls. The validated method was successfully applied to a bioequivalence study with a fixed-dose formulation consisting of 5 mg SAXA and 500 mg MET in 18 healthy subjects. The reproducibility of the assay was demonstrated by reanalysis of 87 incurred samples.


Assuntos
Adamantano/análogos & derivados , Cromatografia Líquida/métodos , Dipeptídeos/sangue , Metformina/sangue , Espectrometria de Massas em Tandem/métodos , Adamantano/sangue , Humanos , Reprodutibilidade dos Testes , Extração em Fase Sólida
6.
J Pharm Biomed Anal ; 131: 64-70, 2016 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-27526402

RESUMO

A reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) method was established for simultaneous determination of two oral hypoglycemic drugs metformin (MET) and sitagliptin (STG) in human plasma. The analytes were extracted from 50µL human plasma by ion-pair solid phase extraction using sodium lauryl sulphate on Phenomenex Strata-X (30mg/1mL) cartridges. The chromatographic separation was accomplished on XSelect HSS CN (150×4.6mm, 5µm) column using mobile phase consisting of methanol-8.0mM ammonium formate in water, pH 4.5 (80:20, v/v) under isocratic condition. Tandem MS detection was performed on a triple quadrupole spectrometer equipped with an electrospray ionization source, operated in the positive mode. Multiple reaction monitoring (MRM) was used to quantify the analytes following transitions, m/z 130.1→60.1 and m/z 408.3→235.1 for MET and STG respectively. The method displayed acceptable linearity in the concentration range of 4.00-3200ng/mL for MET and 1.00-800ng/mL for STG. The intra-batch and inter-batch precisions were ≤5.1% and accuracy ranged from 96.5 to 103.3% for both the drugs. The mean recovery of MET and STG obtained from spiked plasma samples was 82.5% and 90.4% respectively with minimal matrix interference. Both the drugs were found to be stable under all mandatory storage conditions. The validated method was successfully applied to a clinical pharmacokinetic study for a fixed-dose tablet formulation containing 500mg MET and 50mg STG in 16 healthy volunteers.


Assuntos
Hipoglicemiantes/sangue , Metformina/sangue , Fosfato de Sitagliptina/sangue , Extração em Fase Sólida/métodos , Cromatografia Líquida/métodos , Humanos , Hipoglicemiantes/análise , Metformina/análise , Fosfato de Sitagliptina/análise , Equivalência Terapêutica
7.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1017-1018: 52-61, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26945134

RESUMO

In the present work the plasma levels of PZA and its two active metabolites, pyrazinoic acid (PA) and 5-hydroxy pyrazinoic acid (5-OH PA) were determined by a sensitive and rapid LC-MS/MS method. The analytes and their labeled internal standards were extracted from 200µL plasma samples by liquid-liquid extraction with methyl tert-butyl ether: diethyl ether (90:10, v/v) under acidic conditions. Their separation was achieved on a Zorbax Eclipse XDB C18 (100×4.6mm, 3.5µm) column using methanol and 0.1% acetic acid (65:35, v/v) as the mobile phase within 4.0min. Detection and quantitation were done by multiple reaction monitoring on a triple quadrupole mass spectrometer following the transitions, m/z 124.1→81.1,m/z 125.0→80.9 and m/z 141.0→81.0 for PZA, PA and 5-OH PA respectively in the positive ionization mode. All the analytes were baseline resolved with a resolution factor of 3.3 and 6.4 between PZA and its metabolites, PA and 5-OH PA respectively. The calibration curves were linear from 0.100-30.0µg/mL, 0.03-9.00µg/mL and 0.002-0.600µg/mL for PZA, PA and 5-OH PA respectively with r(2)≥0.9980 for all the analytes. The intra-batch and inter-batch accuracy and precision (% CV) across quality controls varied from 93.5-106.7% and 1.10-4.57 respectively for all the analytes. The mean extraction recovery of PZA, PA and 5-OH PA was 83.7%, 89.2% and 80.8% respectively, which was consistent at higher as well as lower concentration levels. The% change in the stability of analytes under different storage conditions ranged -6.7 to 7.1 for all the analytes. The method was applied to assess the comparative bioavailability of a 500mg PZA test and reference formulation in healthy subjects. The assay reproducibility was also tested by reanalysis of 22 incurred subject samples.


Assuntos
Cromatografia Líquida/métodos , Pirazinamida/análogos & derivados , Pirazinamida/sangue , Espectrometria de Massas em Tandem/métodos , Calibragem , Humanos , Pirazinamida/farmacocinética , Controle de Qualidade , Padrões de Referência
8.
Biomed Chromatogr ; 30(2): 208-16, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26096961

RESUMO

A simple, sensitive and reproducible ultra-performance liquid chromatography-tandem mass spectrometry method has been developed for the simultaneous determination of atenolol, a ß-adrenergic receptor-blocker and chlorthalidone, a monosulfonamyl diuretic in human plasma, using atenolol-d7 and chlorthalidone-d4 as the internal standards (ISs). Following solid-phase extraction on Phenomenex Strata-X cartridges using 100 µL human plasma sample, the analytes and ISs were separated on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 µm) column using a mobile phase consisting of 0.1% formic acid-acetonitrile (25:75, v/v). A tandem mass spectrometer equipped with electrospray ionization was used as a detector in the positive ionization mode for both analytes. The linear concentration range was established as 0.50-500 ng/mL for atenolol and 0.25-150 ng/mL for chlorthalidone. Extraction recoveries were within 95-103% and ion suppression/enhancement, expressed as IS-normalized matrix factors, ranged from 0.95 to 1.06 for both the analytes. Intra-batch and inter-batch precision (CV) and accuracy values were 2.37-5.91 and 96.1-103.2%, respectively. Stability of analytes in plasma was evaluated under different conditions, such as bench-top, freeze-thaw, dry and wet extract and long-term. The developed method was superior to the existing methods for the simultaneous determination of atenolol and chlorthalidone in human plasma with respect to the sensitivity, chromatographic analysis time and plasma volume for processing. Further, it was successfully applied to support a bioequivalence study of 50 mg atenolol + 12.5 mg chlorthalidone in 28 healthy Indian subjects.


Assuntos
Atenolol/sangue , Clortalidona/sangue , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Atenolol/química , Atenolol/farmacocinética , Clortalidona/química , Clortalidona/farmacocinética , Estabilidade de Medicamentos , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Pharm Anal ; 6(2): 87-94, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29403967

RESUMO

An improved and reliable ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the determination of lercanidipine in human plasma. Plasma samples with lercanidipine-d3 as an internal standard (IS) were prepared by solid phase extraction on Phenomenex Strata-X cartridges using 100 µL of human plasma. Chromatographic analysis was performed on UPLC BEH C18 (50 mm×2.1 mm, 1.7 µm) column under isocratic conditions. Linear calibration curves were obtained over a wide dynamic concentration range of 0.010-20.0 ng/mL. Matrix effect was assessed by post-column infusion, post-extraction spiking and standard-line slope methods. The mean extraction recovery was >94% for the analyte and IS. Inter-batch and intra-batch precision (% CV) across five quality controls was <5.8%. Bioequivalence study was performed with 36 healthy subjects after oral administration of 10 mg of lercanidipine and the assay reproducibility was evaluated by reanalysis of 133 incurred samples.

10.
J Pharm Anal ; 6(4): 276-281, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29403993

RESUMO

A rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method is described for determination of letrozole in human plasma. Following solid phase extraction (SPE) of letrozole and letrozole-d4 on Orochem DVB-LP cartridges, chromatography was performed on Acquity UPLC BEH C18 (50 mm×2.1 mm, 1.7 µm) column using methanol-0.1% formic acid in water (85:15, v/v) as the mobile phase. Detection was carried out on a triple quadrupole mass spectrometer with an electrospray source, operated under positive ionization mode. Quantitation of letrozole and letrozole-d4 was done using multiple reaction monitoring (MRM) following the transitions at m/z 286.2→217.0 and m/z 290.2→221.0, respectively. The calibration plots were linear through the concentration range of 0.10-100 ng/mL (r2≥0.9990) using 100 µL human plasma. The extraction recovery of letrozole ranged from 94.3% to 96.2% and the intra-batch and inter-batch precision was ≤5.2%. The method was successfully applied to a bioequivalence study of letrozole after oral administration of 2.5 mg tablet formulation to 16 healthy postmenopausal Indian women. The assay reproducibility was also established through incurred sample reanalysis (ISR) of 74 subject samples.

11.
Biomed Chromatogr ; 29(10): 1527-34, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25761551

RESUMO

A simple, rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the determination of alosetron (ALO) in human plasma. The assay method involved solid-phase extraction of ALO and ALO 13C-d3 as internal standard (IS) on a LichroSep DVB-HL (30 mg, 1 cm(3) ) cartridge. The chromatography was performed on an Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile and 2.0 mm ammonium formate, pH 3.0 adjusted with 0.1% formic acid (80:20, v/v) as the mobile phase in an isocratic mode. For quantitative analysis, the multiple reaction monitoring transitions studied were m/z 295.1/201.0 for ALO and m/z 299.1/205.1 for IS in the positive ionization mode. The method was validated over a concentration range of 0.01-10.0 ng/mL for ALO. Post-column infusion experiment showed no positive or negative peaks in the elution range of the analyte and IS after injection of extracted blank plasma. The extent of ion-suppression/enhancement, expressed as IS-normalized matrix factor, varied from 0.96 to 1.04. The assay recovery was within 97-103% for ALO and IS. The method was successfully applied to support a bioequivalence study of 1.0 mg alosetron tablets in 28 healthy Indian male and female subjects.


Assuntos
Carbolinas/sangue , Carbolinas/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Adolescente , Adulto , Calibragem , Estudos Cross-Over , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Equivalência Terapêutica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA