Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Interv Cardiol Clin ; 13(3): 369-384, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38839170

RESUMO

Over the last 2 decades, experience with transcatheter pulmonary valve replacement (TPVR) has grown significantly and has become an effective and reliable way of treating pulmonary valve regurgitation, right ventricular outflow (RVOT) obstruction, and dysfunctional bioprosthetic valves and conduits. With the introduction of self-expanding valves and prestents, dilated native RVOT can be addressed with the transcatheter approach. In this article, the authors review the current practices, technical challenges, and outcomes of TPVR.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Cardiopatias Congênitas/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico , Obstrução do Fluxo Ventricular Externo/cirurgia , Desenho de Prótese , Bioprótese
2.
Pediatr Cardiol ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38761285

RESUMO

In the present era, the intricacy of procedures undertaken by a pediatric interventional cardiologist has increased, primarily attributed to dealing with smaller, younger patients with more complex anatomies. To adapt to these smaller and more complex patients, we must adapt our interventions and our equipment to perform these procedures. This article outlines various innovative applications of the SwiftNinja steerable microcatheter within the pediatric cardiac catheterization laboratory.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38736246

RESUMO

BACKGROUND: Stent implantation has become standard of care in older children and adults for treatment of branch pulmonary artery stenosis (BPAS) and coarctation aorta (CoAo). There are no stents approved or available for infants that have the potential to be dilated to adult diameters. The Minima stent was designed to fulfill this unmet need. METHODS: Multicenter, prospective, nonrandomized early feasibility study evaluating safety and effectiveness of the Minima stent for treatment of BPAS and CoAo. Primary endpoints included: (1) successful deployment across lesion, (2) stenosis relief defined by an increase in angiographic diameter of >50% and (3) freedom from stent explant, embolization or migration at 30 days and 6 months. RESULTS: Between 2/2022 and 5/2022, 10 pts underwent Minima stent implantation with a median age and weight of 9 months (4-43 months) and 7.6 kg (5.1-16.9 kg). Procedural success and predefined stenosis relief was achieved in all cases (CoAo [n = 4], BPAS [n = 6]). Adverse events occurred in 3 pts: transient diminished lower extremity pulse (n = 2), distal stent on-balloon displacement successfully managed in the catheterization suite (n = 1). There were no deaths or major adverse events. All patients were free from stent explant and migration at 30 days and 6 months with no evidence for significant restenosis at latest follow-up. CONCLUSIONS: Implantation of the Renata Minima stent was safe and effective for the treatment of BPAS and CoAo in this small cohort of infants and young children during early follow-up. Based on these early results, an expanded study with longer follow-up is warranted.

4.
J Pediatr ; 272: 114122, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38815742

RESUMO

OBJECTIVE: To test the hypothesis that neonates with symptomatic tetralogy of Fallot (TOF) and absent ductus arteriosus (ADA) have worse clinical outcomes compared with those with a ductus arteriosus (DA), and that this difference is driven by those born with ADA and with critically deficient pulmonary blood flow (CDPBF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of neonates who underwent intervention for symptomatic TOF comparing death and reintervention between subjects with and without a DA identified on fetal echocardiogram or on echocardiogram performed in the first postnatal day. Exclusion criteria were as follows: inability to define DA status, collaterals supplying pulmonary blood flow, atrioventricular septal defect, and absent pulmonary valve. We defined CDPBF as undergoing a procedure to augment pulmonary blood flow on the date of birth or extracorporeal membrane oxygenation prior to such a procedure. RESULTS: The study cohort included 519 patients, among whom 11% had ADA. Patients with ADA were more likely to have a genetic syndrome and had smaller branch pulmonary artery size. In analyses adjusting for center, interventional treatment strategy, genetic syndrome, and minimum branch pulmonary artery size, ADA was associated with higher mortality risk (adjusted hazard ratio of 2.37 (95% CI: 1.07,5.27; P = .034). Seven patients had CDPBF (1.3% of the entire cohort and 12% of patients with ADA). CONCLUSIONS: A minority of symptomatic TOF neonates have ADA, which is associated with higher adjusted mortality risk compared with those with a DA. CDPBF appears to be a rare but important entity in this population.

5.
Cardiol Young ; : 1-3, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38618881

RESUMO

Immobilisation of mechanical valve leaflets can be a life-threatening complication. In the acute setting, medical therapy can be attempted but is not always successful. We present the first described case of a patient with a mechanical tricuspid valve with recurrent leaflet immobilisation that was able to be mobilised using a transcatheter knocking technique.

6.
Catheter Cardiovasc Interv ; 103(4): 580-586, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38353500

RESUMO

BACKGROUND: Use of alternate access for complex neonatal interventions has gained acceptance with carotid and axillary artery access being used for ductal and aortic interventions. METHODS: This study was a retrospective, single-center study at Cincinnati Children's Hospital Medical Center. The study included infants, aged ≤90 days, who underwent cardiac catheterization with either carotid or axillary artery access between 2013 and 2022. Data encompassing demographics, clinical information, catheterization data, and the incidence of pseudoaneurysm as a procedural complication were collected. RESULTS: Among 29 young infants (20 males, 69%), 4 out of 15 patients (27%) who underwent the carotid approach developed pseudoaneurysms, while 1 out of 14 patients (7.1%) who underwent the axillary approach developed one. Two patients required transcatheter intervention due to enlargement of pseudoaneurysms, involving the placement of transarterial flow-diverting stent and occlusion of left common carotid artery. Longer sheath in-to-out time (135 vs. 77 min, p = 0.001), and higher closing activated clotting times (ACT) (268 vs. 197 s, p = 0.021) were observed among patients with pseudoaneurysms compared to those without. CONCLUSIONS: Young infants with alternative access via the carotid and axillary arteries may be at risk of pseudoaneurysm formation during longer procedures and with higher ACTs for closure. Ultrasound-guided compression can be employed to prevent the progression and in resolution of these lesions.


Assuntos
Falso Aneurisma , Masculino , Recém-Nascido , Lactente , Criança , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/epidemiologia , Falso Aneurisma/etiologia , Artéria Axilar/diagnóstico por imagem , Estudos Retrospectivos , Incidência , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Fatores de Risco , Artéria Femoral
7.
Circ Cardiovasc Interv ; 17(3): e012834, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258562

RESUMO

BACKGROUND: Current metrics used to adjust for case mix complexity in congenital cardiac catheterization are becoming outdated due to the introduction of novel procedures, innovative technologies, and expanding patient subgroups. This study aims to develop a risk adjustment methodology introducing a novel, clinically meaningful adverse event outcome and incorporating a modern understanding of risk. METHODS: Data from diagnostic only and interventional cases with defined case types were collected for patients ≤18 years of age and ≥2.5 kg at all Congenital Cardiac Catheterization Project on Outcomes participating centers. The derivation data set consisted of cases performed from 2014 to 2017, and the validation data set consisted of cases performed from 2019 to 2020. Severity level 3 adverse events were stratified into 3 tiers by clinical impact (3a/b/c); the study outcome was clinically meaningful adverse events, severity level ≥3b (3bc/4/5). RESULTS: The derivation data set contained 15 224 cases, and the validation data set included 9462 cases. Clinically meaningful adverse event rates were 4.5% and 4.2% in the derivation and validation cohorts, respectively. The final risk adjustment model included age <30 days, Procedural Risk in Congenital Cardiac Catheterization risk category, and hemodynamic vulnerability score (C statistic, 0.70; Hosmer-Lemeshow P value, 0.83; Brier score, 0.042). CONCLUSIONS: CHARM II (Congenital Heart Disease Adjustment for Risk Method II) risk adjustment methodology allows for equitable comparison of clinically meaningful adverse events among institutions and operators with varying patient populations and case mix complexity performing pediatric cardiac catheterization.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Criança , Humanos , Lactente , Fatores de Risco , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Hemodinâmica , Risco Ajustado/métodos
8.
Catheter Cardiovasc Interv ; 102(6): 1105-1108, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37855191

RESUMO

Intracardiac masses and specifically right atrial thrombi can be difficult to manage and carry a high mortality rate. Typically, surgical removal or mechanical thrombectomy can be performed though may not be suitable for all patients. We present a unique case of a sickle cell patient with a large pedunculated right atrial thrombus that was successfully extracted using the novel ONO Retrieval Device.


Assuntos
Fibrilação Atrial , Cardiopatias , Trombose , Humanos , Trombectomia , Cardiopatias/diagnóstico por imagem , Cardiopatias/cirurgia , Resultado do Tratamento , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia
9.
J Perinatol ; 43(10): 1238-1244, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37587183

RESUMO

OBJECTIVE: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder. STUDY DESIGN: Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or procedure-related events were evaluated. A total of 156 of the available 182 patients (86%) completed the study. RESULTS: The implant success rate was 95.5% (191/200). At 3 years, PDA closure was observed in 100% (33/33) of patients. Survival was >95% with 9 reported deaths. No deaths were adjudicated as device- or procedure-related. Notable events included aortic obstruction (2) requiring stent placement and tricuspid regurgitation (5), for which no interventions were required. CONCLUSIONS: This follow-up study demonstrates high rates of PDA closure, low serious complication rates, and survival > 95% at 3 years. The Amplatzer Piccolo™ Occluder is a safe and effective therapy for PDA treatment in premature infants. CLINICALTRIALS: gov identifier: NCT0305585.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Criança , Seguimentos , Permeabilidade do Canal Arterial/cirurgia , Estudos Prospectivos , Cateterismo Cardíaco/efeitos adversos , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento
10.
J Am Coll Cardiol ; 82(7): 615-627, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558375

RESUMO

BACKGROUND: Neonates with symptomatic tetralogy of Fallot (sTOF) with hypoplastic pulmonary arteries (hPA) are considered high risk. Data are needed to inform the impact of hPA on outcomes, and the ideal management strategy. OBJECTIVES: The objectives of this study were to quantify the impact of hPA on outcomes in neonates with sTOF and measure the impact of strategy on pulmonary artery (PA) growth in this population. METHODS: Neonates with sTOF from 2005 to 2017 were reviewed from the Congenital Cardiac Research Collaborative. Criteria for hPA included a unilateral PA z score <-2.0 and contralateral PA z score <0. Primary outcome was mortality. Secondary outcomes included reintervention and PA growth. RESULTS: We included 542 neonates with sTOF, including 188 (35%) with hPA and 354 (65%) with normal PA, with median follow-up of 4.1 years. Median right and left hPA z scores were -2.19 (25th-75th percentile: -2.55 to -1.94) and -2.23 (25th-75th percentile: -2.64 to -1.91), respectively. Staged repair (vs primary TOF repair) was less common in the hPA cohort (36 vs 44%; P = 0.07). Survival was similar between groups (unadjusted P = 0.16; adjusted P = 0.25). Reintervention was more common in the hPA group (HR: 1.28; 95% CI: 1.01-1.63; P = 0.044); there was no difference after definitive repair (HR: 1.21; 95% CI: 0.93-1.58; P = 0.16). PA growth at 1 year was greater in the hPA cohort, particularly for the right PA (P < 0.001). CONCLUSIONS: Despite perception, the presence of hPA in neonates with sTOF conferred no increase in overall hazard of mortality or reintervention after definitive repair. PA growth was superior in the hPA cohort. These findings suggest that the presence of hPA does not adversely impact outcomes in sTOF.


Assuntos
Tetralogia de Fallot , Recém-Nascido , Humanos , Lactente , Tetralogia de Fallot/cirurgia , Artéria Pulmonar/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
11.
Pediatr Cardiol ; 44(8): 1691-1701, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37382636

RESUMO

The Pediatric Heart Network's Fontan Udenafil Exercise Longitudinal (FUEL) Trial (Mezzion Pharma Co. Ltd., NCT02741115) demonstrated improvements in some measures of exercise capacity and in the myocardial performance index following 6 months of treatment with udenafil (87.5 mg twice daily). In this post hoc analysis, we evaluate whether subgroups within the population experienced a differential effect on exercise performance in response to treatment. The effect of udenafil on exercise was evaluated within subgroups defined by baseline characteristics, including peak oxygen consumption (VO2), serum brain-type natriuretic peptide level, weight, race, gender, and ventricular morphology. Differences among subgroups were evaluated using ANCOVA modeling with fixed factors for treatment arm and subgroup and the interaction between treatment arm and subgroup. Within-subgroup analyses demonstrated trends toward quantitative improvements in peak VO2, work rate at the ventilatory anaerobic threshold (VAT), VO2 at VAT, and ventilatory efficiency (VE/VCO2) for those randomized to udenafil compared to placebo in nearly all subgroups. There was no identified differential response to udenafil based on baseline peak VO2, baseline BNP level, weight, race and ethnicity, gender, or ventricular morphology, although participants in the lowest tertile of baseline peak VO2 trended toward larger improvements. The absence of a differential response across subgroups in response to treatment with udenafil suggests that the treatment benefit may not be restricted to specific sub-populations. Further work is warranted to confirm the potential benefit of udenafil and to evaluate the long-term tolerability and safety of treatment and to determine the impact of udenafil on the development of other morbidities related to the Fontan circulation.Trial Registration NCT0274115.


Assuntos
Consumo de Oxigênio , Sulfonamidas , Humanos , Criança , Sulfonamidas/uso terapêutico , Exercício Físico , Pirimidinas/uso terapêutico , Teste de Esforço , Tolerância ao Exercício
12.
Cardiol Young ; 33(11): 2405-2407, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37317799

RESUMO

Mechanical thrombectomy is generally used in adult patients with pulmonary embolism or extensive venous thromboembolism, but it is starting to become more prevalent in the children. We present a unique case of a 3-year-old female with very early-onset inflammatory bowel disease with extensive venous thromboembolism who underwent successful mechanical thrombectomy.


Assuntos
Doenças Inflamatórias Intestinais , Embolia Pulmonar , Tromboembolia Venosa , Trombose Venosa , Adulto , Feminino , Criança , Humanos , Pré-Escolar , Trombectomia , Trombose Venosa/complicações , Trombose Venosa/cirurgia , Embolia Pulmonar/complicações , Embolia Pulmonar/cirurgia , Doenças Inflamatórias Intestinais/complicações
13.
Pediatr Cardiol ; 44(6): 1414-1417, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37227453

RESUMO

Management of pulmonary atresia, ventricular septal defect with major aorto-pulmonary collateral arteries, and hypoplastic native pulmonary arteries focuses on growth of the native pulmonary arteries. One strategy to grow the native pulmonary arteries is through pulmonary valve perforation followed by right ventricular outflow tract stenting, if suitable. We present a unique case of retrograde pulmonary valve perforation and stenting of the right ventricular outflow tract through a major aorto-pulmonary collateral artery.


Assuntos
Cardiopatias Congênitas , Comunicação Interventricular , Atresia Pulmonar , Valva Pulmonar , Humanos , Lactente , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/cirurgia , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Artéria Pulmonar/anormalidades , Circulação Colateral
14.
Pediatr Cardiol ; 44(5): 1183-1186, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36867232

RESUMO

Transcatheter tricuspid valve placement in congenital heart disease is becoming increasingly used when a previously placed surgical ringed valve becomes dysfunctional. Surgically repaired and/or native tricuspid inflows are generally not amenable to transcatheter valve placement without a prior ring being placed. We present the second pediatric case to our knowledge of transcatheter tricuspid valve placement in a surgically repaired tricuspid valve in the absence of a ring.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Criança , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco , Desenho de Prótese
15.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
16.
World J Pediatr Congenit Heart Surg ; 14(4): 527-530, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36972508

RESUMO

Microvascular pulmonary arteriovenous malformations (pAVMs) can lead to profound hypoxemia. "Hepatic factor" is postulated to play a role in their development. Certain patients with congenital heart disease are at particular risk to develop pAVMs, including those with heterotaxy syndromes and complex Fontan palliation. Ideally, an underlying cause is identified and corrected, although pAVMs may persist despite those interventions. We report a patient with heterotaxy syndrome s/p Fontan who had pAVMs that persisted despite Fontan revision with equal hepatic flow to both lungs. We employed a novel method to produce a diabolo configuration of a large covered stent to restrict lung flow while maintaining the potential for future dilation.


Assuntos
Malformações Arteriovenosas , Síndrome de Heterotaxia , Veias Pulmonares , Humanos , Malformações Arteriovenosas/complicações , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Artéria Pulmonar/anormalidades , Veias Pulmonares/cirurgia , Veias Pulmonares/anormalidades , Síndrome de Heterotaxia/complicações , Síndrome de Heterotaxia/cirurgia , Cianose/etiologia , Cianose/cirurgia , Stents/efeitos adversos
17.
J Thorac Cardiovasc Surg ; 166(3): 916-925.e6, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36828672

RESUMO

OBJECTIVE: Neonates with tetralogy of Fallot and pulmonary atresia (TOF/PA) but no major aorta-pulmonary collaterals are dependent on the arterial duct for pulmonary blood flow and require early intervention, either by primary (PR) or staged repair (SR) with initial palliation (IP) followed by complete repair (CR). The optimal approach has not been established. METHODS: Neonates with TOF/PA who underwent PR or SR were retrospectively reviewed from the Congenital Cardiac Research Collaborative. Outcomes were compared between PR and SR (IP + CR) strategies. Propensity scoring was used to adjust for baseline differences. The primary outcome was mortality. Secondary outcomes included complications, length of stay, cardiopulmonary bypass and anesthesia times, reintervention (RI), and pulmonary artery (PA) growth. RESULTS: Of 282 neonates, 106 underwent PR and 176 underwent SR (IP: 144 surgical, 32 transcatheter). Patients who underwent SR were more likely to have DiGeorge syndrome and greater rates of mechanical ventilation before the initial intervention. Mortality was not significantly different. Duration of mechanical ventilation, inotrope use, and complication rates were similar. Cumulative length of stay, cardiopulmonary bypass, and anesthesia times favored PR (P ≤ .001). Early RI was more common in patients who underwent SR (rate ratio, 1.42; P = .003) but was similar after CR (P = .837). Conduit size at the time of CR was larger with SR. Right PA growth was greater with PR. CONCLUSIONS: In neonates with TOF/PA, SR is more common in greater-risk patients. Accounting for this, SR and PR strategies have similar mortality. Perioperative morbidities, RI, and right PA growth generally favor PR, whereas SR allows for larger initial conduit implantation.


Assuntos
Síndrome de DiGeorge , Atresia Pulmonar , Tetralogia de Fallot , Recém-Nascido , Humanos , Lactente , Atresia Pulmonar/cirurgia , Atresia Pulmonar/complicações , Estudos Retrospectivos , Aorta , Artéria Pulmonar/cirurgia , Resultado do Tratamento
18.
Pediatr Cardiol ; 44(4): 795-805, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36806971

RESUMO

Data on the frequency and outcome of surgical interventions as a result of adverse events (AE) encountered in the pediatric and congenital cardiac catheterization laboratory are limited. This study analyzes the outcomes of specific types of AE that are most likely to require immediate surgical intervention. Data from the C3PO registry were analyzed to identify specific types of significant vascular/cardiac trauma or technical adverse events (stent/device/coil embolization/migration). The relationship between these AE and an "adverse outcome" (defined as either surgery, ECMO, or death) were analyzed. Between 01/2014 and 12/2017, 25,731 cases were entered into the C3PO registry. Vascular or cardiac trauma were observed in 92 cases (0.36% cases in C3PO), and technical adverse events were observed in 176 cases (0.68% cases in C3PO). The two highest procedure type risk categories (PREDIC3T) accounted for 61% of the cases in the cardiac/vascular trauma cohort, and 34% in the technical AE cohort. For vascular/cardiac trauma, 24 (26%) had an adverse outcome, with ECMO in 8 (9%), surgery in 19 (20%), and death in 9 (10%). For technical AE 25 (14%) had an adverse outcome, with ECMO in 3 (2%), surgery in 23 (13%), and death in 3 (2%). Survival after cardiac surgery secondary to an AE was 68% for cardiac/vascular trauma, and 96% for technical adverse events. RF perforation of the pulmonary valve was the procedure most likely to result in cardiac/vascular trauma (10%), with 57% of those having an adverse outcome. Atrial septal interventions accounted for 29% of all adverse outcomes in the cardiac/vascular trauma cohort. Non-elective or emergent cases were associated with a significantly higher incidence of an adverse outcome for both, cardiac/vascular trauma (OR 7.1) and technical adverse events (OR 2.7). Surgery within the last 30 days was associated with a significantly higher incidence of an adverse outcome for cardiac/vascular trauma only (OR 4.2). Significant cardiac/vascular trauma or stent/device/coil embolization/migration are rare, but high consequence AE. With appropriate surgical and ECMO backup, a high survival can be achieved. The potential need for and impact of immediate surgical backup seems to be higher for cardiac/vascular trauma (in particular after specific case types), than for device/coil migration/embolization, and as such case specific backup arrangements are required.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Valva Pulmonar , Cirurgia Torácica , Criança , Humanos , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Fatores de Risco
20.
Ann Thorac Surg ; 116(1): 86-93, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36481325

RESUMO

BACKGROUND: Early postoperative catheterizations (EPOCs) within 6 weeks after a congenital heart surgical procedure can treat residual lesions and provide important clinical information. However, EPOCs are often assumed to impose additional risk on a vulnerable patient population. This study aimed to describe the EPOC population, evaluate procedural safety, compare EPOC patients with procedure-matched non-EPOC patients, and determine risk factors for poor outcomes using data from the Congenital Cardiac Catheterization Project on Outcomes registry. METHODS: In a retrospective cohort, demographic, clinical, and procedural characteristics were analyzed for diagnostic and interventional catheterizations performed in 13 participating institutions from January 2014 to December 2017, excluding patients after heart transplant. The primary outcome was a high-severity adverse event (AE). Three distinct analyses included (1) describing the full cohort and EPOC patients, (2) comparing EPOC patients with and without a high-severity AE, and (3) comparing EPOC patients with controls matched on case type. RESULTS: This study included 17,776 catheterizations, with 1399 EPOCs. The high-severity AE rate was 6.4% overall, 8.9% in the EPOC cohort, and 8.4% in matched controls (P = .74). The association between EPOC status and high-severity AE was not significant in a multivariable model (P = .17). In EPOCs with a high-severity AE, median procedure duration was 30 minutes longer (P < .001), and median time from surgical procedure to catheterization was 3 days longer (P = .05). CONCLUSIONS: EPOC was not associated with additional risk. Individual patient characteristics of size and hemodynamic vulnerability may serve as informative predictors. Timely catheterization may preempt further clinical deterioration, and intraprocedure duration optimization may correlate with improved outcomes.


Assuntos
Cardiopatias Congênitas , Humanos , Estudos Retrospectivos , Cardiopatias Congênitas/diagnóstico , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA