Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Med Imaging Radiat Sci ; 52(3): 385-389, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34001456

RESUMO

INTRODUCTION: This study was conducted to assess the diagnostic accuracy of three-dimensional computed tomography (3D-CT) in detection of cervical spine injuries in symptomatic post-trauma patients using multiplanar computed tomography (MP-CT) as reference standard. APPROACH: This cross-sectional study was conducted at Aga Khan University from July 2016 to January 2017. Patients were included using a non-probability, consecutive sampling. MP-CT and 3D- CT images were obtained and evaluated by a senior radiologist to identify cervical spine injuries. RESULTS: 205 patients were included in the study. For fractures, 3D-CT images had sensitivity of 71%, specificity of 100%, positive predictive value (PPV) of 100%, negative predictive value (NPV) of 96.8% and diagnostic accuracy of 97%. For dislocations, 3D-CT reported sensitivity of 83.34%, specificity of 100%, positive predictive value of 100% and negative predictive value of 99.5% and diagnostic accuracy of 99.5%. CONCLUSION: 3D-CT has good diagnostic accuracy for injuries of the cervical spine but must be reviewed simultaneously with multiplanar CT images.


Assuntos
Vértebras Cervicais , Tomografia Computadorizada por Raios X , Vértebras Cervicais/diagnóstico por imagem , Computadores , Estudos Transversais , Humanos , Sensibilidade e Especificidade
2.
J Coll Physicians Surg Pak ; 31(3): 340-341, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33775029

RESUMO

Pseudo-aneurysm of internal maxillary artery, following a road traffic accident, is a rare clinical scenario. The consequence of pseudo-aneurysm may be spontaneous rupture of the arterial wall, which may eventually lead to life-threatening hemorrhage. We report a case of a 20-year male who presented with recurrent epistaxis. CT scan was performed, which revealed a pseudo-aneurysm of the internal maxillary artery; this was successfully treated by angioembolisation. Similar cases of traumatic pseudo-aneurysms have been reported, however, none presented with recurrent epistaxis after management of pan-facial fractures. Key Words: Epistaxis, Pseudo-aneurysm, Angioembolisation, Pan-facial fracture.


Assuntos
Falso Aneurisma , Doenças das Artérias Carótidas , Embolização Terapêutica , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Artérias , Epistaxe/etiologia , Epistaxe/terapia , Humanos , Masculino , Artéria Maxilar/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA