Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 265: 116689, 2024 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-39208511

RESUMO

Transistor-based biosensing (BioFET) is a long-enduring vision for next generation medical diagnostics. The study addresses a challenge associated with the BioFET solution gating. The standard BioFET sensing measurement involves sweeping of the solution gate (Vsol) with a concurrent measurement of the source-drain current (IDS). This IDS-Vsol sweep poses a great challenge, as Vsol does not only determine IDS, but also determines the pH levels, ion concentrations, and electric fields at the sensing area double layer accommodating the biomolecules. Therefore, inevitably, an IDS-Vsol sweep implies that the sensing area double layer is not in an electrochemical equilibrium, but rather in a continuous transient state as electrochemical potential gradients induce transient ion currents continuously affecting double layer hosting the biomolecules and the biological interactions. This challenge calls for a BioFET design which permits IDS sweeping from an off-state to an on-state while keeping Vsol constant and the double layer sensing area in electrochemical equilibrium. The study explores a BioFET design addressing this challenge by decoupling the solution potential from IDS gating. Specific and label-free sensing of ferritin in 0.5 µL drops of 1:100 diluted plasma is pursued. We show an excellent sensing performance once the solution potential and IDS gating are decoupled, with a limit-of-detection of 10 fg/ml, a dynamic range of 10 orders of magnitude in ferritin concentration and excellent linearity and sensitivity. In contrast, a poor sensing performance is recorded for the conventional Vsol sweep performed in parallel to the above. Extensive control measurements quantifying the non-specific signals are reported.


Assuntos
Técnicas Biossensoriais , Desenho de Equipamento , Ferritinas , Transistores Eletrônicos , Técnicas Biossensoriais/instrumentação , Ferritinas/sangue , Humanos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos
2.
Biosens Bioelectron ; 258: 116368, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38744114

RESUMO

Biosensing with biological field-effect transistors (bioFETs) is a promising technology toward specific, label-free, and multiplexed sensing in ultra-small samples. The current study employs the field-effect meta-nano-channel biosensor (MNC biosensor) for the detection of the enzyme N-acetyl-beta-D-glucosaminidase (NAGase), a biomarker for milk cow infections. The measurements are performed in a 0.5 µL drops of 3% commercial milk spiked with NAGase concentrations in the range of 30.3 aM-3.03 µM (Note that there is no background NAGase concentration in commercial milk). Specific and label-free sensing of NAGase is demonstrated with a limit-of-detection of 30.3 aM, a dynamic range of 11 orders of magnitude and with excellent linearity and sensitivity. Additional two important research outcomes are reported. First, the ionic strength of the examined milk is ∼120 mM which implies a bulk Debye screening length <1 nm. Conventionally, a 1 nm Debye length excludes the possibility of sensing with a recognition layer composed of surface bound anti-NAGase antibodies with a size of ∼10 nm. This apparent contradiction is removed considering the ample literature reporting antibody adsorption in a predominantly surface tilted configuration (side-on, flat-on, etc.). Secondly, milk contains a non-specific background protein concentration of 33 mg/ml, in addition to considerable amounts of micron-size heterogeneous fat structures. The reported sensing was performed without the customarily exercised surface blocking and without washing of the non-specific signal. This suggests that the role of non-specific adsorption to the BioFET sensing signal needs to be further evaluated. Control measurements are reported.


Assuntos
Acetilglucosaminidase , Técnicas Biossensoriais , Limite de Detecção , Leite , Técnicas Biossensoriais/métodos , Leite/química , Animais , Bovinos , Acetilglucosaminidase/análise , Concentração Osmolar , Transistores Eletrônicos , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA