Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 220: 114984, 2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-35994945

RESUMO

A simple, rapid, sensitive and specific LC-MS/MS method was developed and validated for the quantitative determination of doxylamine in human plasma, using isotope doxylamine-d5 as internal standard (IS). The detection was conducted on a QTRAP 5500 tandem mass spectrometer coupled with electrospray ionization (ESI) source in positive ion mode. Quantification was achieved by positive electrospray ionization containing multiple reaction monitoring (MRM) transitions of m/z 271.0→182.0 for doxylamine and m/z 276.2→187.3 for IS. The mobile phase A was methanol, and mobile phase B was 20 mM ammonium acetate (0.2 % formic acid) in water, using a gradient elution procedure at a flow rate of 0.6 mL/min. The method was validated with a sensitivity of 0.500 ng/mL and a linear concentration range of 0.500-200 ng/mL. The inter-batch precision (%CV) was less than 5.4 %, and the accuracy deviation (%RE) ranged from - 10.6 % to 3.7 %; the inter-batch precision (%CV) was less than 6.6 %, and the accuracy deviation (%RE) was ranged from - 2.7 % to 0.1 %. The selectivity, sensitivity, extraction recovery, matrix effect, carryover, dilution reliability, stability and other characteristics were within the acceptable range. This validated method was successfully applied to a bioequivalence study that orally administered 25 mg of doxylamine succinate tablets in 60 healthy Chinese volunteers.


Assuntos
Doxilamina/sangue , Doxilamina/farmacocinética , Antagonistas dos Receptores Histamínicos H1/sangue , Antagonistas dos Receptores Histamínicos H1/farmacocinética , Espectrometria de Massas em Tandem/métodos , Administração Oral , China , Cromatografia Líquida/métodos , Doxilamina/administração & dosagem , Voluntários Saudáveis , Antagonistas dos Receptores Histamínicos H1/administração & dosagem , Humanos , Metanol , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray , Comprimidos , Equivalência Terapêutica
2.
Artigo em Inglês | MEDLINE | ID: mdl-35063863

RESUMO

A rapid, simple, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was validated for the determination of terbinafine concentrations in the plasma of healthy Chinese subjects. Terbinafine-d7 was used as the internal standard (IS), and the acetonitrile protein precipitation method was selected. The processed samples were chromatographically separated with a C18 column. The mobile phases were 0.1% formic acid (FA) in water (A), and methanol (B), respectively, and the gradient elution program was used with a flow rate of 0.8 mL/min. Quantification was achieved by positive electrospray ionization containing multiple reaction monitoring (MRM) transitions of m/z 292.5 â†’ 141.1 for terbinafine and m/z 299.5 â†’ 148.1 for IS. The calibration curve range was 2.00-1200 ng/mL; the intra- and inter-batch precision (coefficient of variation, %CV) was <8.2%, with the accuracy deviation (relative error, %RE) of -6.5% to 10.2%. The selectivity, sensitivity, extraction recovery, matrix effect, dilution reliability, carryover, and stability were within the acceptable range. This method was successfully applied to a bioequivalence study that orally administered 125 mg of terbinafine hydrochloride tablets in 84 healthy Chinese subjects.


Assuntos
Antifúngicos/farmacocinética , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Terbinafina/farmacocinética , Adolescente , Adulto , Antifúngicos/administração & dosagem , Antifúngicos/sangue , China , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Terbinafina/administração & dosagem , Terbinafina/sangue , Equivalência Terapêutica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA