Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Front Pediatr ; 11: 1157272, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252040

RESUMO

Objective: Central precocious puberty (CPP) is a rare condition that causes early sexual development in children. Although the cure is effective, the etiology of central precocious puberty is unclear. Methods: In total, 10 girls with central precocious puberty and same number of age-matched female controls were enrolled. Plasma samples were collected from each participant and subjected to untargeted metabolomics and lipidomics. Student's t-tests were employed to compare the mean of each metabolite and lipid. Furthermore, orthogonal partial least-squares discriminant analysis was conducted and the variable importance in the projection was calculated to identify differentially expressed metabolites or lipids. Subsequent bioinformatics was conducted to investigate the potential function of differentially expressed metabolites and lipids. Results: Fifty-nine differentially expressed metabolites were identified based on the criteria used (variable importance in the projection >1 and a P value < 0.05). Kyoto Encyclopedia Genes and Genome (KEGG) enrichment analysis showed that differentially expressed metabolites were enriched in four pathways: beta-alanine metabolism, histidine metabolism, bile secretion, and steroid hormone biosynthesis. As for the lipidomics, 41 differentially expressed lipids were observed and chain length analysis and lipid saturation analysis yielded similar results. Significant differences between the two groups were only observed in (O-acyl) ω-hydroxy fatty acids (OAHFA). Conclusion: The present study showed that antibiotic overuse, increased meat consumption, and obesity may have potential roles in the development of central precocious puberty in girls. Several metabolites have diagnostic value but further research is required.

2.
J Clin Lab Anal ; 34(7): e23291, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32147884

RESUMO

BACKGROUND: Blood gas analyzers are capable of delivering results on electrolytes and metabolites within a few minutes and facilitate clinical decision-making. However, whether the results can be used interchangeably with values measured by chemistry analyzers remains controversial. Blood gas analyzers are capable of delivering results on electrolytes and metabolites within a few minutes and facilitate clinical decision-making. However, whether the results can be used interchangeably with values measured by chemistry analyzers remains controversial. METHODS: In total, arterial and matched venous blood samples were collected from 200 hospitalized patients. Arterial blood samples were evaluated using a RAPIDPOINT 500 to test electrolyte and glucose levels, then the samples were centrifuged and the same parameters were measured with an AU5800. Venous blood samples were processed and tested in accordance with standard operation procedures. Data were compared by using a paired t test, the agreement between the two analyzers was evaluated by using the Bland-Altman test, and sensitivity and specificity were calculated. RESULTS: Paired t tests showed that all parameters tested were significantly different between the two analyzers except chloride. The biases calculated indicated that blood gas analyzers tend to underestimate the parameters, and the linear regression showed a strong correlation between the two analyzers. The sensitivity, specificity and kappa values demonstrated that the diagnostic performance of blood gas analyzers is not satisfactory. CONCLUSION: The significant reduction in parameter estimation and diagnostic performance we observed suggested that clinicians should interpret results from blood gas analyzers more cautiously. The reference interval of blood gas analyzers should be adjusted accordingly, given that values are underestimated.


Assuntos
Gasometria/instrumentação , Glicemia/análise , Eletrólitos/sangue , Automação Laboratorial , Gasometria/métodos , Humanos , Flebotomia , Potássio/sangue , Valores de Referência , Sensibilidade e Especificidade , Sódio/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA