Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Vet Cardiol ; 31: 1-7, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32836069

RESUMO

Idiopathic pulmonary arterial hypertension is a rare disease reported in humans and dogs diagnosed as persistent elevation of pulmonary arterial blood pressure without predisposing or associated diseases. A four-month-old pot-bellied pig (Sus scrofa domesticus) was presented for decreased appetite, lethargy, respiratory distress, and occasional syncope. On physical examination, the pig was tachypneic with labored breathing, with a distended abdomen and a bilateral grade 4-5/6 parasternal systolic heart murmur. Systolic pulmonary arterial pressure was estimated at 95 mmHg by Doppler echocardiography, consistent with severe pulmonary hypertension. At autopsy, there was dilation of the main pulmonary artery and right ventricle. The lungs were diffusely rubbery, and there was tricavitary effusion. Microscopically, there was severe widespread pulmonary arterial concentric medial hypertrophy with rare plexiform lesions. The clinical history and gross and microscopic findings supported a diagnosis of idiopathic pulmonary arterial hypertension with subsequent right-sided congestive heart failure. Primary (idiopathic) pulmonary arterial hypertension should be considered as a differential diagnosis in young pigs with right-sided congestive heart failure.


Assuntos
Insuficiência Cardíaca/veterinária , Hipertensão Pulmonar/veterinária , Doenças dos Suínos/diagnóstico , Animais , Diagnóstico Diferencial , Ecocardiografia Doppler/veterinária , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico , Masculino , Sus scrofa , Suínos , Doenças dos Suínos/diagnóstico por imagem , Doenças dos Suínos/patologia
5.
Infect Immun ; 68(4): 2187-95, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10722619

RESUMO

It is generally accepted that cellular, but not humoral immunity, plays an important role in host defense against intracellular bacteria. However, studies of some of these pathogens have provided evidence that antibodies can provide immunity if present during the initiation of infection. Here, we examined immunity against infection by Ehrlichia chaffeensis, an obligate intracellular bacterium that causes human monocytic ehrlichiosis. Studies with mice have demonstrated that immunocompetent strains are resistant to persistent infection but that SCID mice become persistently and fatally infected. Transfer of immune serum or antibodies obtained from immunocompetent C57BL/6 mice to C57BL/6 scid mice provided significant although transient protection from infection. Bacterial clearance was observed when administration occurred at the time of inoculation or well after infection was established. The effect was dose dependent, occurred within 2 days, and persisted for as long as 2 weeks. Weekly serum administration prolonged the survival of susceptible mice. Although cellular immunity is required for complete bacterial clearance, the data show that antibodies can play a significant role in the elimination of this obligate intracellular bacterium during active infection and thus challenge the paradigm that humoral responses are unimportant for immunity to such organisms.


Assuntos
Anticorpos Antibacterianos/imunologia , Ehrlichia chaffeensis/imunologia , Ehrlichia chaffeensis/metabolismo , Animais , Antígenos de Bactérias/imunologia , Linfócitos B/imunologia , Sangue/imunologia , Western Blotting , Linhagem Celular , Cães , Imunofluorescência , Imunidade , Imunização Passiva , Fígado/imunologia , Fígado/microbiologia , Camundongos , Camundongos Endogâmicos C57BL , Camundongos SCID , Receptores de Antígenos de Linfócitos T/imunologia , Baço/imunologia , Baço/microbiologia , Linfócitos T/imunologia , Fatores de Tempo
6.
Infect Immun ; 66(8): 3892-9, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9673277

RESUMO

To determine the basis of susceptibility and resistance to human monocytic ehrlichiosis (HME), immunocompetent and immunocompromised mice were infected with Ehrlichia chaffeensis and bacterial loads were measured by PCR and by immunohistochemistry. Immunocompetent (C. B-17 and C57BL/6) mice cleared the bacteria within 10 days, but immunocompromised SCID and SCID/BEIGE mice developed persistent infection in the spleen, liver, peritoneal cavity, brain, lung, and bone marrow and became moribund within 24 days. Both immunocompromised strains lack T and B lymphocytes, but the SCID/BEIGE strain is also deficient in natural killer (NK) cell function. During advanced stages of disease, the infections were associated with wasting, splenomegaly, lymphadenopathy, liver granulomas and necroses, intravascular coagulation, and granulomatous inflammation. Histochemical and immunohistochemical localization studies confirmed the presence of bacteria in tissues, and viable bacteria were cultured from infected animals. The data reveal that T and/or B cells play an essential role during resistance of immunocompetent mice to infection with E. chaffeensis and demonstrate the utility of immunocompromised mice as an experimental model for the study of HME.


Assuntos
Ehrlichia chaffeensis/fisiologia , Ehrlichiose/fisiopatologia , Animais , Modelos Animais de Doenças , Vias de Administração de Medicamentos , Ehrlichia chaffeensis/crescimento & desenvolvimento , Ehrlichiose/microbiologia , Ehrlichiose/patologia , Feminino , Humanos , Hospedeiro Imunocomprometido , Camundongos , Camundongos Endogâmicos C57BL , Camundongos SCID , Esplenomegalia , Redução de Peso
7.
Rev Sci Instrum ; 50(9): 1080-3, 1979 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18699671

RESUMO

A device for the measurement of concentration fluctuations in flowing gases which can be used to establish and control the degree of mixing is described. The design is based on an improved laser-schlieren technique combined with photometric detection. The device operates on-line and has high sensitivity and fast response. A quantitative sensitivity evaluation is made and checked experimentally. The device is used to characterize the performance of some simple mixing configurations. The detection limits for various gas mixtures are given.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA