Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Dosim ; 49(1): 19-24, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37914563

RESUMO

To assess the performance of a knowledge-based planning (KBP) model for generating intensity-modulated proton therapy (IMPT) treatment plans as part of an adaptive radiotherapy (ART) strategy for patients with high-risk prostate cancer. A knowledge-based planning (KBP) model for proton adaptive treatment plan generation was developed based on thirty patient treatment plans utilizing RapidPlanTM PT (Varian Medical Systems, Palo Alto, CA). The model was subsequently validated using an additional eleven patient cases. All patients in the study were administered a prescribed dose of 70.2 Gy to the prostate and seminal vesicle (CTV70.2), along with 46.8 Gy to the pelvic lymph nodes (CTV46.8) through simultaneous integrated boost (SIB) technique. To assess the quality of the validation knowledge-based proton plans (KBPPs), target coverage and organ-at-risk (OAR) dose-volume constraints were compared against those of clinically used expert plans using paired t-tests. The KBP model training statistics (R2) (mean ± SD, 0.763 ± 0.167, range, 0.406 to 0.907) and χ² values (1.162 ± 0.0867, 1.039-1.253) indicate acceptable model training quality. Moreover, the average total treatment planning optimization and calculation time for adaptive plan generation is approximately 10 minutes. The CTV70.2 D98% for the KBPPs (mean ± SD, 69.1 ± 0.08 Gy) and expert plans (69.9 ± 0.04 Gy) shows a significant difference (p < 0.05) but are both within 1.1 Gy of the prescribed dose which is clinically acceptable. While the maximum dose for some organs-at-risk (OARs) such as the bladder and rectum is generally higher in the KBPPs, the doses still fall within clinical constraints. Among all the OARs, most of them received comparable results to the expert plan, except the cauda equina Dmax, which shows statistical significance and was lower in the KBPPs than in expert plans (48.5 ± 0.06 Gy vs 49.3 ± 0.05 Gy). The generated KBPPs were clinically comparable to manually crafted plans by expert treatment planners. The adaptive plan generation process was completed within an acceptable timeframe, offering a quick same-day adaptive treatment option. Our study supports the integration of KBP as a crucial component of an ART strategy, including maintaining plan consistency, improving quality, and enhancing efficiency. This advancement in speed and adaptability promises more precise treatment in proton ART.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Masculino , Humanos , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Próstata/radioterapia
2.
Front Oncol ; 13: 1132178, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576891

RESUMO

Introduction: Dose perturbation of spot-scanning proton beams passing through a dislocated metallic port (MP) of a breast tissue expander may degrade target dose coverage or deliver excess dose to the ipsilateral lung and heart. The feasibility of utilizing daily cone-beam computed tomography (CBCT)-based synthetic CTs (synCTs) for dose reconstruction was evaluated, and the fractional and cumulative dosimetric impact due to daily MP dislocation is reported. Methods: The synCT was generated by deforming the simulation CT to daily CBCT. The MP structure template was mapped onto all CTs on the basis of daily MP position. Proton treatment plans were generated with two and three fields on the planned CT (pCT, Plan A) and the first verification CT (vCT, Plan B), respectively, for a fractional dose of 1.8 Gy(RBE). Plan A and Plan B were used alternatively, as determined by the daily MP position. The reconstructed fractional doses were calculated with corresponding plans and synCTs, and the cumulative doses were summed with the rigid or deformed fractional doses on pCT and vCT. Results: The planned and reconstructed fractional dose demonstrated a low-dose socket around the planned MP position due to the use of field-specific targets (FSTs). Dose hot spots with >120% of the prescription due to MP dislocation were found behind the planned MP position on most reconstructed fractional doses. The reconstructed cumulative dose shows two low-dose sockets around the two planned MP positions reflecting the two plans used. The doses at the hot spots behind the planned MPs averaged out to 114% of the prescription. The cumulative D95% of the CTV_Chest Wall decreased by up to 2.4% and 4.0%, and the cumulative V20Gy(RBE) of the left lung decreased to 16.1% and 16.8% on pCT and vCT, respectively. The cumulative Dmean of the heart decreased to as low as 0.7 Gy(RBE) on pCT but increased to as high as 1.6 Gy(RBE) on vCT. Conclusion: The robustness of proton plans using FSTs around the magnet in the MP of the tissue expander can be improved by applying multiple fields and plans, which provides forgiveness of dose heterogeneity incurred from dislocation of high-Z materials in this single case.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA