Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Children (Basel) ; 11(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38790524

RESUMO

Supraglottic airway devices such as laryngeal masks and i-gels are useful for airway management. The i-gel is a relatively new device that replaces the air-inflated cuff of the laryngeal mask with a gel-filled cuff. It remains unclear which device is more effective for neonatal resuscitation. We aimed to evaluate the dependence of successful airway management in neonatal simulators on the device type and providers' backgrounds. Ninety-one healthcare providers performed four attempts at airway management using a laryngeal mask and i-gel in two types of neonatal manikins. The dependence of successful insertions within 16.7 s (75th percentile of all successful insertions) on the device type and providers' specialty, years of healthcare service, and completion of the neonatal resuscitation training course was assessed. Successful insertion (p = 0.001) and insertion time (p = 0.003) were associated with using the i-gel vs. laryngeal mask. The providers' backgrounds were not associated with the outcome. Using the i-gel was associated with more successful airway management than laryngeal masks using neonatal manikins. Considering the limited effect of the provider's specialty and experience, using the i-gel as the first-choice device in neonatal resuscitation may be advantageous. Prospective studies are warranted to compare these devices in the clinical setting.

2.
Brain Dev ; 40(8): 714-718, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29631775

RESUMO

Rett syndrome is a neurodevelopmental disorder caused by mutations in the MECP2 gene, which encodes methyl-CpG-binding protein 2 (MECP2). It almost exclusively affects the female sex and is considered lethal in the male sex. However, an increasing number of male patients with MECP2 mutations have been reported, including patients who suddenly died of unknown causes. We report a case of MECP2 mutation in a male patient who exhibited neonatal encephalopathy. He developed severe apnea, epilepsy, and psychomotor developmental delay and died suddenly of sick sinus syndrome at 17 months of age. Severe bradycardia had been noticed since 16 months of age. His older brother followed a similar clinical course and died at 30 months of age. The brother had also experienced severe bradycardia. This familial case might help to clarify the causes of sudden death in cases of MECP2 mutations.


Assuntos
Apneia/genética , Proteína 2 de Ligação a Metil-CpG/genética , Mutação , Síndrome do Nó Sinusal/genética , Pré-Escolar , Evolução Fatal , Humanos , Lactente , Masculino , Linhagem
3.
Pediatr Int ; 59(2): 154-158, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27706892

RESUMO

BACKGROUND: Guidelines recommend avoiding excessive oxygen during neonatal resuscitation. Recent studies have suggested that oxygen titration can be achieved using a self-inflating bag, but data on the effectiveness of resuscitators used in neonatal ventilation are scarce, The aim of this study was therefore to determine the amount of oxygen delivered using several brands of neonatal self-inflating resuscitation bags without reservoirs under different conditions with regard to oxygen flow rate, ventilation rate (VR), peak inspiratory pressure (PIP) range, and test lung compliance. METHODS: Oxygen concentration was measured under a variety of conditions. Combinations of oxygen flow rate (10, 5.0, 3.0 and 1.0 L/min), VR (40, 60 inflations/min), PIP range (20-25 cmH2 O, 35-40 cmH2 O), and test lung compliance (0.6, 1.0, 3.0, and 5.0 mL/cmH2 O) were examined using six kinds of self-inflating bag. RESULTS: Delivered oxygen concentration varied widely (30.1-96.7%) and had a significant positive correlation with gas flow rate in all of the bags. Delivered oxygen concentration was also negatively correlated with PIP in all of the bags and with VR in some of them. Test lung compliance did not affect delivered oxygen concentration. CONCLUSION: The use of neonatal resuscitation self-inflating bags without reservoirs resulted in different delivered oxygen concentrations depending on gas flow rate, VR, PIP, and manufacturer, but not on lung compliance. This suggests that targeted oxygen concentrations could be delivered, even in lungs with decreased compliance, during resuscitation.


Assuntos
Oxigenoterapia/instrumentação , Oxigênio/administração & dosagem , Respiração com Pressão Positiva/instrumentação , Humanos , Técnicas In Vitro , Recém-Nascido , Complacência Pulmonar , Oxigenoterapia/métodos , Respiração com Pressão Positiva/métodos
4.
Ind Health ; 54(6): 488-497, 2016 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-27396766

RESUMO

Child health checkups are an important public service to support children's development; however, many children do not attend all the child health checkups that are required by maternal and child health law (i.e., at 1 month, 4 months, 1 and a half years, and 3 years of age). This study aimed to identify social and household factors influencing child health checkup attendance. We used data from a longitudinal household panel study in Japan. The total number of subjects was 2,612 children. We extracted numerous social variables reflecting childcare and conducted logistic regression analyses. In every health checkup, the attendance rate was significantly lower for children whose birth order was 3rd or later. Children whose father graduated from a 4-year college or whose mother had 5 or more communicating neighbors were significantly more likely to attend the 1-and-a-half-year checkup. Children whose maternal annual income was in the middle range (1.5 to 5.0 million yen) tended not to attend checkups after 1 and a half years of age. We concluded that the later birth order was the factor of non-attendance. On the other hand, high paternal educational attainment and many communicating neighbors were identified as the factors of attendance.


Assuntos
Exame Físico/estatística & dados numéricos , Adulto , Ordem de Nascimento , Criança , Saúde da Criança , Pré-Escolar , Feminino , Humanos , Japão , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Capital Social , Apoio Social , Fatores Socioeconômicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA