Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 17(7): e0268671, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35839206

RESUMO

Periodontal disease is a chronic inflammatory condition caused by periodontal pathogens in the gingival sulcus. Short-chain fatty acids (SCFAs) produced by causal bacteria are closely related to the onset and progression of periodontal disease and have been reported to proliferate in the periodontal sulcus of patients experiencing this pathology. In such patients, propionic acid (C3), butyric acid (C4), isobutyric acid (IC4), valeric acid (C5), isovaleric acid (IC5), and caproic acid (C6), henceforth referred to as [C3-C6], has been reported to have a detrimental effect, while acetic acid (C2) exhibits no detrimental effect. In this study, we established an inexpensive and simple enzymatic assay that can fractionate and measure these acids. The possibility of applying this technique to determine the severity of periodontal disease by adapting it to specimens collected from humans has been explored. We established an enzyme system using acetate kinase and butyrate kinase capable of measuring SCFAs in two fractions, C2 and [C3-C6]. The gingival crevicular fluid (GCF) and saliva of 10 healthy participants and 10 participants with mild and severe periodontal disease were measured using the established enzymatic method and conventional gas chromatography-mass spectrometry (GC-MS). The quantification of C2 and [C3-C6] in human GCF and saliva was well correlated when using the GC-MS method. Furthermore, both C2 and [C3-C6] in the GCF increased with disease severity. However, while no significant difference was observed between healthy participants and periodontal patients when using saliva, [C3-C6] significantly differed between mild and severe periodontal disease. The enzymatic method was able to measure C2 and [C3-C6] separately as well as using the GC-MS method. Furthermore, the C2 and [C3-C6] fractions of GCF correlated with disease severity, suggesting that this method can be applied clinically. In contrast, the quantification of C2 and [C3-C6] in saliva did not differ significantly between healthy participants and patients with periodontal disease. Future studies should focus on inflammation rather than on tissue destruction.


Assuntos
Ácidos Graxos Voláteis , Doenças Periodontais , Ácido Acético , Ácido Butírico , Ácidos Graxos Voláteis/análise , Líquido do Sulco Gengival/química , Humanos , Doenças Periodontais/diagnóstico
2.
Scand J Clin Lab Invest ; 69(6): 687-95, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19484658

RESUMO

OBJECTIVE: The MB fraction of creatine kinase (CK-MB) has long been used as a cardiac marker. It is known that the CK-MB immunoinhibition method lacks selectivity and accuracy, because the appearance of macro CK type 2, corresponding to mitochondrial creatine kinase (MtCK) in some patient serum may render CK-MB activity measured by conventional method abnormally high. Thus, to improve the specificity and accuracy of the CK-MB assay, we developed two types of monoclonal anti-MtCK antibodies against sarcomeric MtCK and ubiquitous MtCK, and present herein the performance of a new method using these antibodies. MATERIAL AND METHODS: The performance of our test for detecting CK-MB activity was compared with other methods, and the range of CK-MB activities in normal human serum was investigated. RESULTS: The two types of monoclonal antibodies developed by us were isoenzyme-specific to sMtCK or uMtCK. The correlation coefficients of our method and conventional method to electrophoresis were 0.973 and 0.873, respectively. The mean CK-MB activity in normal human serum by our method and the conventional method was 2.4 and 11.7 U/L, respectively. Thus, our data indicated that about 80% of CK-MB activity, determined using the conventional method, seems to correspond to the MtCK activity. CONCLUSION: Our method is novel in offering higher accuracy of measuring true CK-MB contents in human serum as compared to the conventional method. The possibility of accurately estimating CK-MB activity by our method which can inhibit MtCKs in healthy person and patient serum is likely to bring a break-through in clinical diagnostics.


Assuntos
Anticorpos Monoclonais/farmacologia , Creatina Quinase Forma MB/sangue , Creatina Quinase Mitocondrial/imunologia , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Especificidade de Anticorpos/efeitos dos fármacos , Sítios de Ligação de Anticorpos , Creatina Quinase Forma BB/antagonistas & inibidores , Creatina Quinase Forma BB/sangue , Creatina Quinase Forma MB/antagonistas & inibidores , Creatina Quinase Mitocondrial/antagonistas & inibidores , Creatina Quinase Mitocondrial/sangue , Eletroforese , Saúde , Humanos , Isoenzimas/antagonistas & inibidores , Isoenzimas/sangue , Membranas Artificiais , Peso Molecular , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA