Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ann Surg Oncol ; 25(4): 1079-1085, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29372363

RESUMO

BACKGROUND/PURPOSE: Development of a humanized fluorophore-conjugated antibody that can improve contrast for fluorescence-guided oncologic surgeries. METHODS: BxPC-3-GFP pancreatic cancer cells were injected into flanks of nude mice. Fragments of subcutaneous tumors were grafted onto the pancreatic tail of recipient mice to create orthotopic xenograft models of pancreatic cancer. After tumors developed for 4 weeks, a humanized anti-carcinoembryonic antigen antibody conjugated to an 800 nm near-infrared fluorescent dye (hM5A-IR800) was injected intravenously. Mice were imaged at 6, 12, 24, 48, and 72 h after injection. RESULTS: Fluorescence imaging showed that hM5A-IR800 specifically localized to BxPC-3 human pancreatic cancer cells. The fluorescent probe localized to cell surfaces in vitro and specifically co-localized with green fluorescent protein-labeled tumors in an orthotopic pancreatic xenograft model in vivo. Serial imaging at specific time points showed peak signal intensity of the orthotopic pancreatic tumor at 48 h; this time point corresponded with a maximal tumor-to-background ratio (TBR) of 16.6 at 48 h. DISCUSSION: hM5A-IR800 was successfully able to specifically label orthotopic pancreatic tumors in situ. The longer wavelength allowed deeper tissue penetration, particularly in tumor areas covered by normal pancreatic parenchyma. The probe had expected kinetics for an antibody-fluorophore conjugate, with the peak signal intensity reached at 48 h. A clear tumor signal was observed with a TBR > 5 at all time points, with high contrast (TBR of 16.6) at 48 h. CONCLUSION: hM5A-IR800 demonstrated excellent tumor localization and a very bright signal. It is a promising agent for future clinical fluorescence-guided surgery applications.


Assuntos
Anticorpos Monoclonais Humanizados , Antígeno Carcinoembrionário/imunologia , Corantes Fluorescentes/química , Imagem Óptica/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Humanos , Camundongos , Camundongos Nus , Neoplasias Pancreáticas/imunologia , Neoplasias Pancreáticas/patologia , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
2.
Oncotarget ; 9(99): 37333-37342, 2018 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-30647873

RESUMO

Pancreatic cancer is a highly lethal disease in part due to incomplete tumor resection. Targeting by tumor-specific antibodies conjugated with a fluorescent label can result in selective labeling of cancer in vivo for surgical navigation. In the present study, we describe a patient-derived orthotopic xenograft model of pancreatic cancer that recapitulated the disease on a gross and microscopic level, along with physiologic clinical manifestations. We additionally show that the use of an anti-CEA antibody conjugated to the near-infrared (NIR) fluorescent dye, IRDye800CW, can selectively highlight the pancreatic cancer and its metastases in this model with a tumor-to-background ratio of 3.5 (SEM 0.9). The present results demonstrate the clinical potential of this labeling technique for fluorescence-guided surgery of pancreatic cancer.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA