Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cent Asian J Glob Health ; 9(1): e371, 2020 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-33062401

RESUMO

INTRODUCTION: Information on microbiological and susceptibility profiles of clinical isolates in Mongolia is scarce, hampering infection control and clinical care. METHODS: Species and resistance profiles of 6334 clinical gram negative isolates, collected at Mongolia's National Center for Maternal and Child Health between 2014 and 2017 were analyzed. RESULTS: Annual proportion of multidrug-resistance among E. coli and Enterobacter isolates increased from 2.8% to 16.6% and 3.5% to 22.6% respectively; Klebsiella isolates exhibiting susceptibilities suggestive of extended spectrum beta-lactamase (ESBL) production from 73% to 94%. By 2017, 60.6% of Klebsiella isolates were multidrug-resistant, most originated from intensive care wards. Enterobacteriaceae exhibiting susceptibility patterns suggestive of ESBL production and multidrug-resistant organisms were common and their incidence increased rapidly. CONCLUSION: These findings will serve to build strategies to strengthen microbiological surveillance, diagnostics and infection control; and to develop empiric therapy and stewardship recommendations for Mongolia's largest Children's and Maternity hospital.

2.
Cent Asian J Glob Health ; 8(1): 380, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32002315

RESUMO

INTRODUCTION: Information on microbiological and susceptibility profiles of Monoglian bacterial isolates is scarce. Resistance profiles, patient demographics and microbiological work-up of gram positive isolates were analyzed in order to develop infection control activities and policies at the National Center for Maternity and Children's Health (NCMCH) in Ulaanbataar, Mongolia. METHODS: All gram positive isolates of specimens submitted to the microbiology laboratory at NCMCH between January 2014 and August 2017 were included. Data collected included demographic data, specimen type, in-/outpatient status, hospital ward of sample origin, and antimicrobial susceptibility testing profile. Susceptibility testing was performed by trained microbiologists at the NCMCH microbiology laboratory. T-test, Mann-Whitney, Chi-square and Fisher exact tests were used as appropriate. RESULTS: Of 11,889 isolates, 4012 (33.7%) were gram positive, with most identified as S. aureus (62.6%, n=2512). Rates of methicillin resistance (MRSA) remained stable at a quarter, but was significantly higher among inpatients (inpatients: 630/2002, 31.5%; outpatients 67/290, 23.1%; p≤0.05) and sterile site isolates (sterile: 83/171, 48.5%; non-sterile: 416/1678, 24.8%; p≤0.01). The vast majority of S. pneumoniae isolates (12/14; 85%) was found to be penicillin resistant by oxacillin disk diffusion. While identification of Group B streptococci was rare (n=137) due to of lack of diagnostic measures available, the number of enterococcal isolates identified increased significantly due to implementation of improved microbiological work-up (2015: n=7; 2016: n=26; 2017: n=83). CONCLUSION: Compared with published studies from neighboring nations, the rates of antimicrobial resistance among gram positive isolates at NCMCH, particularly with respect to S. aureus and S. pneumoniae, were much higher. Further improvement of microbiological diagnostics and collaboration of stakeholders is required to address the pressing infection control and stewardship issues and to ensure reliable identification of relevant pathogens in Mongolia.

3.
Eur J Pediatr ; 174(10): 1299-304, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25869495

RESUMO

UNLABELLED: Transcutaneous bilirubin (TcB) nomograms have been developed for different populations. However, the TcB level, rate of rise and peak varies among countries and ethnicities. The aim of this study was to establish an hour-specific TcB nomogram for healthy term and late preterm Mongolian neonates during the first 144 h after birth. A total of 5084 TcB measurements from 1297 healthy neonates (gestational age ≥35 weeks, birth weight ≥2000 g) were obtained from October 2012 to October 2013. All measurements were performed using the Jaundice Meter, the JM-103 at 6 to 144 postnatal hours. Mongolian infants had the following characteristics: 27.1 % were delivered by cesarean section, 17.8 % had a birth weight >4000 g, and >90 % were being breastfed. TcB percentiles for each designated time point were calculated for the development of an hour-specific nomogram. TcB levels increased most rapidly in the first 24 h and less rapidly from 24 to 78 h, reaching a plateau after 78 h for the 50th percentile. TcB levels of Mongolian neonates for each time point were higher than those of previous studies. CONCLUSION: The higher values of the TcB nomogram for Mongolian neonates may be due to their Asian ethnicity and exclusive breastfeeding. WHAT IS KNOWN: • TcB nomograms for neonatal jaundice screening have been established for many countries and ethnicities. The pattern of the TcB nomogram varies by country and ethnicity. What is New: • A TcB nomogram for neonates of Mongolian ethnicity at 6-144 postnatal hours was created and it had higher values than those in previous studies.


Assuntos
Bilirrubina/análise , Hiperbilirrubinemia Neonatal/diagnóstico , Triagem Neonatal/métodos , Feminino , Seguimentos , Idade Gestacional , Humanos , Hiperbilirrubinemia Neonatal/epidemiologia , Hiperbilirrubinemia Neonatal/metabolismo , Recém-Nascido , Masculino , Mongólia/epidemiologia , Nomogramas , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo
4.
PLoS One ; 8(10): e79427, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24205385

RESUMO

BACKGROUND: In Mongolia, adequate early diagnosis and treatment of developmental hip dysplasia (DDH) have been unavailable and its incidence was unknown. We determined the incidence of ultrasonographic DDH in newborns and established adequate procedures for diagnosis and treatment of DDH at the largest maternity hospital in Ulaanbaatar, Mongolia. METHODOLOGY/PRINCIPAL FINDINGS: During one year (Sept 2010 - Aug 2011) we assessed the hips newborns using ultrasound and Graf's classification of DDH. 8,356 newborns were screened; median age at screening was 1 day. We identified 14,873 Type 1 (89.0%), 1715 Type 2a (10.3%), 36 Type 2c (0.2%), 70 Type D (0.4%), 14 Type 3 (0.08%), and 4 Type 4 hips (0.02%). Children with Type 1 hips (normal) were discharged. Children with Type 2a hips (physiologically immature) received follow-up ultrasounds at monthly intervals. Children with Type 2c to 4 (DDH; deformed or misaligned hip joint) hips were treated with a Tubingen hip flexion splint and also followed up. The hip abnormalities resolved to mature hips in all children who were followed up. There was no evidence for severe treatment related complications. CONCLUSION/SIGNIFICANCE: This study suggests that the incidence of DDH in Mongolian neonates is comparable to that in neonates in Europe. Early ultrasound-based assessment and splinting treatment of DDH led to mature hips in all children followed up. Procedures are feasible and will be continued.


Assuntos
Luxação do Quadril/epidemiologia , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/terapia , Humanos , Incidência , Recém-Nascido , Programas de Rastreamento , Mongólia/epidemiologia , Estudos Prospectivos , Fatores de Risco , Contenções , Ultrassonografia
5.
BMC Pediatr ; 13: 151, 2013 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-24074043

RESUMO

BACKGROUND: Neonatal hyperbilirubinemia, especially kernicterus, can be prevented by screening for neonatal jaundice. The transcutaneous bilirubin (TcB) meter is a non-invasive medical device for screening neonates. The study aimed to investigate the validity of a TcB meter in a resource-limited setting such as Mongolia. METHODS: Term and late preterm neonates from the National Center for Maternal and Child Health of Ulaanbaatar in Mongolia who met the inclusion criteria (gestational age ≥35 weeks, birth weight ≥2000 g, postnatal age ≤ 1 month) were enrolled in the study. We used a TcB meter, JM-103 to screen for neonatal jaundice. TcB measurements at the infant's forehead and midsternum were performed within 3 h of obtaining samples for total serum bilirubin (TSB) measurement. We analyzed the correlation between TcB measurements and TSB measurements to validate the meter. RESULTS: A total of 47 term and six late preterm neonates were included in the study. TcB measured by the meter at both the forehead and the midsternum showed a strong correlation with TSB measured in the laboratory. The correlation equations were TSB = 1.409+0.8655 × TcB (R2=0.78871) at the forehead, and TSB = 0.7555+0.8974 × TcB (R2=0.78488) at the midsternum. Bland-Altman plots and the Bradley-Blackwood test showed no significant differences between the two methods at all measured ranges of bilirubin. The mean areas under the curves of TcB at the forehead and midsternum at three TSB levels (>10 mg/dL, >13 mg/dL, >15 mg/dL) of TcB were greater than 0.9, and all had high sensitivity and specificity. CONCLUSIONS: This study established the validity of the JM-103 meter as a screening tool for neonatal jaundice in term and late preterm infants in Mongolia. Future studies are needed, including the establishment of a TcB hour-specific nomogram, for more effective clinical practice to prevent severe hyperbilirubinemia.


Assuntos
Bilirrubina/análise , Hiperbilirrubinemia Neonatal/diagnóstico , Icterícia Neonatal/diagnóstico , Triagem Neonatal/instrumentação , Área Sob a Curva , Coleta de Amostras Sanguíneas/instrumentação , Feminino , Humanos , Recém-Nascido , Icterícia Neonatal/sangue , Modelos Lineares , Masculino , Mongólia , Triagem Neonatal/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA