Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Endovasc Ther ; : 15266028241271679, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39148208

RESUMO

INTRODUCTION: The present standard of care to treat aortic arch pathologies is open surgical repair with cardiopulmonary bypass and deep hypothermic arrest. With approaches for total endovascular and extra-anatomic cervical debranching hybrid arch repair becoming more diverse, understanding what is considered a successful operation is prerequisite for a rigorous comparison of techniques. This review describes the specific outcomes reported, the rates of success, and the definitions of technical and clinical success in total endovascular and extra-anatomic cervical debranching hybrid aortic arch repair. METHODS: A comprehensive search of MEDLINE, Embase, and the Cochrane Central Register of Controlled Trials was performed. Studies with patients undergoing total endovascular or hybrid extra-anatomic cervical debranching repair of the aortic arch were included. Any publications including only patients with Ishimaru zone 2 or distal repairs were excluded from this review. Studies with less than 5 patients were excluded. Data extraction was performed by one author. Data items included were study design, procedure type, procedural details, underlying pathology, type of cervical debranching, type of endograft repair, surgical outcomes, definition of cerebrovascular events, technical success, and the definition of technical success. RESULTS: Of 1754 studies screened for review, 85 studies with 5521 patients were included. By frequency, the included studies examined the following interventions: fenestrated devices, branched devices, parallel grafting. Most studies were retrospective single-institution studies. There were no randomized controlled trials. Short-term mortality and cerebrovascular events were nearly universally reported, present in 99% and 95% of studies reviewed, respectively. Only 27% of studies provided an explicit definition for cerebrovascular events. While 75% of studies reported a technical success rate, only 45% of those studies provided explicit criteria. Clinical success rates were infrequently reported, present in only 5.9% of studies reviewed. CONCLUSION: The definitions of technical success that were provided fell short of analogous defined reporting standards in nearly all studies, inflating technical success rates. Definitions of cerebrovascular events and technical success require stringent criteria to uniformly compare various methods of endovascular aortic arch repair. A societal consensus document for reporting standards of endovascular aortic arch repair would allow for higher-quality outcomes research. CLINICAL IMPACT: Total endovascular and extra-anatomic cervical debranching hybrid operations are being increasingly utilized for complex aortic arch repair. These techniques, however, can be associated with serious complications. Currently, there is no accepted metric to define technical or report clinical outcomes. Due to the paucity of high-quality data, use of these approaches may be limited in clinical practice. This study emphasizes the need for the development of standards for reporting outcomes in endovascular aortic arch repair. Future studies can then utilize these benchmarks, whcih will allow for improved efficacy and safety in these techniques.

2.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Assuntos
Endocardite , Falha de Prótese , Infecções Relacionadas à Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Remoção de Dispositivo , Próteses Valvulares Cardíacas/efeitos adversos , Bioprótese/efeitos adversos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
3.
EClinicalMedicine ; 68: 102364, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38586479

RESUMO

Background: RBT-1 is a combination drug of stannic protoporfin (SnPP) and iron sucrose (FeS) that elicits a preconditioning response through activation of antioxidant, anti-inflammatory, and iron-scavenging pathways, as measured by heme oxygenase-1 (HO-1), interleukin-10 (IL-10), and ferritin, respectively. Our primary aim was to determine whether RBT-1 administered before surgery would safely and effectively elicit a preconditioning response in patients undergoing cardiac surgery. Methods: This phase 2, double-blind, randomised, placebo-controlled, parallel-group, adaptive trial, conducted in 19 centres across the USA, Canada, and Australia, enrolled patients scheduled to undergo non-emergent coronary artery bypass graft (CABG) and/or heart valve surgery with cardiopulmonary bypass. Patients were randomised (1:1:1) to receive either a single intravenous infusion of high-dose RBT-1 (90 mg SnPP/240 mg FeS), low-dose RBT-1 (45 mg SnPP/240 mg FeS), or placebo within 24-48 h before surgery. The primary outcome was a preoperative preconditioning response, measured by a composite of plasma HO-1, IL-10, and ferritin. Safety was assessed by adverse events and laboratory parameters. Prespecified adaptive criteria permitted early stopping and enrichment. This trial is registered with ClinicalTrials.gov, NCT04564833. Findings: Between Aug 4, 2021, and Nov 9, 2022, of 135 patients who were enrolled and randomly allocated to a study group (46 high-dose, 45 low-dose, 44 placebo), 132 (98%) were included in the primary analysis (46 high-dose, 42 low-dose, 44 placebo). At interim, the trial proceeded to full enrollment without enrichment. RBT-1 led to a greater preconditioning response than did placebo at high-dose (geometric least squares mean [GLSM] ratio, 3.58; 95% CI, 2.91-4.41; p < 0.0001) and low-dose (GLSM ratio, 2.62; 95% CI, 2.11-3.24; p < 0.0001). RBT-1 was generally well tolerated by patients. The primary drug-related adverse event was dose-dependent photosensitivity, observed in 12 (26%) of 46 patients treated with high-dose RBT-1 and in six (13%) of 45 patients treated with low-dose RBT-1 (safety population). Interpretation: RBT-1 demonstrated a statistically significant cytoprotective preconditioning response and a manageable safety profile. Further research is needed. A phase 3 trial is planned. Funding: Renibus Therapeutics, Inc.

4.
Ann Cardiothorac Surg ; 13(2): 155-164, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38590997

RESUMO

Background: CONVERGE was a prospective, multicenter, randomized controlled trial that evaluated the safety of Hybrid Atrial Fibrillation Convergent (HC) and compared its effectiveness to endocardial catheter ablation (CA) for the treatment of persistent atrial fibrillation (PersAF) and longstanding PersAF (LSPAF). In 2020, we reported that CONVERGE met its primary safety and effectiveness endpoints. The primary objective of the present study is to report CONVERGE trial results for quality of life (QOL) and Class I/III anti-arrhythmic drug (AAD) utilization following HC. Methods: Eligible patients had drug-refractory symptomatic PersAF or LSPAF and a left atrium diameter ≤6.0 cm. Enrolled patients were randomized 2:1 to receive HC or CA. Atrial Fibrillation Severity Scale (AFSS) and the 36-Item Short Form Health Survey (SF-36) were assessed at baseline and 12 months; statistical comparison was performed using paired t-tests. AAD utilization at baseline through 12 and 18 months post-procedure was evaluated; statistical comparison was performed using McNemar's tests. Results: A total of 153 patients were treated with either HC (n=102) or CA (n=51). Of the 102 HC patients, 38 had LSPAF. AFSS and SF-36 Mental and Physical Component scores were significantly improved at 12 months versus baseline with HC overall and for the subset of LSPAF patients treated with either HC or CA. The proportion of HC patients (n=102) who used Class I /III AADs at 12 and 18 months was significantly less (33.3% and 36.3%, respectively) than baseline (84.3%; P<0.001). In LSPAF patients who underwent HC (n=38), AADs use was 29.0% through 18 months follow-up versus 71.1% at baseline (P<0.001). Conclusions: HC reduced AF symptoms, significantly improved QOL, and reduced AAD use in patients with PersAF and LSPAF. ClinicalTrialsgov Identifier: NCT01984346.

5.
Ann Thorac Surg ; 117(2): 336-343, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37769702

RESUMO

BACKGROUND: The safety and effectiveness of the RelayPro endograft (Terumo Aortic) was assessed for the treatment of acute, complicated type B aortic dissection (TBAD). METHODS: A prospective pivotal trial analyzed a primary end point of all-cause mortality at 30 days. Secondary end points included technical success, major adverse events (disabling stroke, renal failure, and paraplegia/paralysis), endoleaks, patency, rupture, device integrity, false lumen perfusion, reinterventions, aortic expansion, and migration evaluated to 5 years. RESULTS: The study involved 22 United States centers and enrolled 56 patients (mean age, 59.5 ± 11.4 years) from 2017 to 2021; of whom, 73.2% were men and 53.6% were African American. TBAD was complicated by malperfusion of the kidneys (51.8%), lower extremities (35.7%), and viscera (33.9%), and rupture (10.7%). Dissection extended proximally to zones 1/2 (14.3%) and zone 3 (78.6%) and distally to the iliac arteries (67.3%). Most procedures were percutaneous (85.5%). Technical success was 100%. Median hospitalization was 7 days (interquartile range, 5-12 days). All-cause mortality at 30 days was 1.8% (1 of 56; upper 95% CI, 8.2%; P < .0001). Seven major adverse events occurred in 6 patients (10.7%), consisting of paraplegia (n = 3), paraparesis (n = 2), disabling stroke (n = 1), and renal failure (n = 1). All paraplegia/paraparesis resolved with lumbar drainage. Kaplan-Meier analysis estimated a freedom from major adverse events of 89.1% at each interval from 30 days to 3 years. There was 1 endoleak (Type Ia), 2 retrograde dissections, and aortic diameter growth occurred in 2. There has been no rupture, fistula, component separation, patency loss, stenosis, kinking, twisting, bird beak, loss of device integrity, or fracture. CONCLUSIONS: RelayPro is safe and effective in acute, complicated TBAD. Follow-up is ongoing to evaluate longer-term outcomes and durability.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Renal , Acidente Vascular Cerebral , Masculino , Humanos , Estados Unidos , Pessoa de Meia-Idade , Idoso , Feminino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Estudos Prospectivos , Resultado do Tratamento , Stents/efeitos adversos , Dissecção Aórtica/cirurgia , Endoleak/etiologia , Paraplegia/etiologia , Estudos Retrospectivos , Insuficiência Renal/etiologia , Acidente Vascular Cerebral/etiologia , Paraparesia/complicações , Procedimentos Endovasculares/efeitos adversos
6.
Cardiovasc Revasc Med ; 59: 9-13, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550124

RESUMO

BACKGROUND/PURPOSE: The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS: We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS: Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS: The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese
7.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
9.
J Cardiothorac Vasc Anesth ; 37(12): 2524-2530, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37716892

RESUMO

OBJECTIVES: Stroke after thoracic aortic surgery is a complication that is associated with poor outcomes. The aim is to characterize the intraoperative risk factors for stroke development. DESIGN: A retrospective analysis. SETTING: Tertiary, high-volume cardiac surgery center. PARTICIPANTS: Patients who had surgical repair of thoracic aortic diseases from January 1, 2017, through December 31, 2021. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 704 patients were included, of whom 533 had ascending aortic aneurysms, and 171 had type A aortic dissection. The incidence of postoperative stroke was 4.5% (95% CI 2.9%-6.6%) for ascending aortic aneurysms compared with 12.3% (95% CI 7.8%-18.16%) in type-A aortic dissections. Patients who developed postoperative strokes had significantly lower intraoperative hemoglobin median (7.5 gm/dL [IQR 6.8-8.6] v 8.55 gm/dL [IQR 7.3-10.0]; p < 0.001). The median cardiopulmonary bypass time was 185 minutes (IQR 136-328) in the stroke group versus 156 minutes (IQR 113-206) in the nonstroke group (p = 0.014). Circulatory arrest was used in 57.8% versus 38.5% of the nonstroke patients (p = 0.017). The initial temperature after leaving the operating room was lower, with a median of 35.0°C (IQR 34-35.92) in the stroke group versus 35.5°C (IQR 35-36) in the nonstroke cohort (p = 0.021). CONCLUSIONS: This single-center study highlighted the potential importance of intra-operative factors in preventing stroke. Lower hemoglobin, longer duration of cardiopulmonary bypass, deep hypothermic circulatory arrest, and postoperative hypothermia are potential risk factors for postoperative stroke. Further studies are needed to prevent this significant complication in patients with thoracic aortic diseases.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Doenças da Aorta , Dissecção Aórtica , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Aorta Torácica/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Risco , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/epidemiologia , Dissecção Aórtica/cirurgia , Doenças da Aorta/cirurgia , Doenças da Aorta/etiologia , Hemoglobinas , Aneurisma da Aorta Torácica/cirurgia , Parada Circulatória Induzida por Hipotermia Profunda/efeitos adversos , Resultado do Tratamento
10.
JACC Case Rep ; 18: 101915, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37545687

RESUMO

We present a case of post-myocardial infarction free-wall rupture in a critically ill patient presenting to the emergency department. Through our case we highlight the prompt evaluation, diagnosis, and management necessary to improve survival in a patient with this life-threatening condition. (Level of Difficulty: Beginner.).

11.
Circ Cardiovasc Interv ; 16(5): e012655, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37192308

RESUMO

BACKGROUND: The LRT trial (Low-Risk Transcatheter Aortic Valve Replacement [TAVR]) demonstrated the safety and feasibility of TAVR in low-risk patients, with excellent 1- and 2-year outcomes. The objective of the current study is to provide the overall clinical outcomes and the impact of 30-day hypoattenuated leaflet thickening (HALT) on structural valve deterioration at 4 years. METHODS: The prospective, multicenter LRT trial was the first Food and Drug Administration-approved investigational device exemption study to evaluate feasibility and safety of TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis. Clinical outcomes and valve hemodynamics were documented annually through 4 years. RESULTS: A total of 200 patients were enrolled, and follow-up was available on 177 patients at 4 years. The rates of all-cause mortality and cardiovascular death were 11.9% and 3.3%, respectively. The stroke rate rose from 0.5% at 30 days to 7.5% at 4 years, and permanent pacemaker implantation rose from 6.5% at 30 days to 11.7% at 4 years. Endocarditis was detected in 2.5% of the cohort, with no new cases reported between 2 and 4 years. Transcatheter heart valve hemodynamics remained excellent post-procedure and were maintained (mean gradient 12.56±5.54 mm Hg and aortic valve area 1.69±0.52 cm2) at 4 years. At 30 days, HALT was observed in 14% of subjects who received a balloon-expandable transcatheter heart valve. There was no difference in valve hemodynamics between patients with and without HALT (mean gradient 14.94±5.01 mm Hg versus 12.3±5.57 mm Hg; P=0.23) at 4 years. The overall rate of structural valve deterioration was 5.8%, and there was no impact of HALT on valve hemodynamics, endocarditis, or stroke at 4 years. CONCLUSIONS: TAVR in low-risk patients with symptomatic severe tricuspid aortic stenosis was found to be safe and durable at 4 years. Structural valve deterioration rates were low irrespective of the type of valve, and the presence of HALT at 30 days did not affect structural valve deterioration, transcatheter valve hemodynamics, and stroke rate at 4 years. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02628899.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Prospectivos , Fatores de Risco , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Hemodinâmica , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Trombose/etiologia
12.
Heart Rhythm O2 ; 4(2): 111-118, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873309

RESUMO

Background: Favorable clinical outcomes are difficult to achieve in long-standing persistent atrial fibrillation (LSPAF) with catheter ablation (CA). The CONVERGE (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent Atrial FIbrillation) trial evaluated the effectiveness of hybrid convergent (HC) ablation vs endocardial CA. Objective: The study sought to evaluate the safety and effectiveness of HC vs CA in the LSPAF subgroup from the CONVERGE trial. Methods: The CONVERGE trial was a prospective, multicenter, randomized trial that enrolled 153 patients at 27 sites. A post hoc analysis was performed on LSPAF patients. The primary effectiveness was freedom from atrial arrhythmias off new or increased dose of previously failed or intolerant antiarrhythmic drugs (AADs) through 12 months. The primary safety endpoint was major adverse event incidence through 30 days with HC. Key secondary effectiveness measures included (1) percent of patients achieving ≥90% AF burden reduction vs baseline and (2) AF freedom. Results: Sixty-five patients (42.5% of total enrollment) had LSPAF; 38 in HC and 27 in CA. Primary effectiveness was 65.8% (95% confidence interval [CI] 50.7%-80.9%) with HC vs 37.0% (95% CI 5.1%-52.4%) with CA (P = .022). Through 18 months, these rates were 60.5% (95% CI 50.0%-76.1%) with HC vs 25.9% (95% CI 9.4%-42.5%) with CA (P = .006). Secondary effectiveness rates were higher than CA with HC at 12 and 18 months. Freedom from atrial arrhythmias off AADs was 52.6% (95% CI 36.8%-68.5%) and 47.4% (95% CI 31.5%-63.2%) with HC at 12 and 18 months vs 25.9% (95% CI 9.4%-42.5%) and 22.2% (95% CI 6.5%-37.9%) with CA, respectively (12 months: P = .031; 18 months: P = .038). Three (7.9%) major adverse events occurred within 30 days of HC. Conclusion: Post hoc analysis demonstrated effectiveness and acceptable safety of HC compared with CA in LSPAF.

13.
Am J Cardiol ; 193: 1-18, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36857839

RESUMO

Since the first transcatheter delivery of an aortic valve prosthesis was performed by Cribier et al in 2002, the picture of aortic stenosis (AS) therapeutics has changed dramatically. Initiated from an indication of inoperable to high surgical risk, extending to intermediate and low risk, transcatheter aortic valve replacement (TAVR) is now an approved treatment for patients with severe, symptomatic AS across all the risk categories. The current evidence supports TAVR as a frontline therapy for treating severe AS. The crucial question remains concerning the subset of patients who still are not ideal candidates for TAVR because of certain inherent anatomic, nonmodifiable, and procedure-specific factors. Therefore, in this study, we focus on these scenarios and reasons for referring selected patients for surgical aortic valve replacement in 2023.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos
14.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858660

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Mortalidade Hospitalar , Resultado do Tratamento , Coração
15.
Am J Cardiol ; 192: 45-50, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36736012

RESUMO

Surgical aortic valve replacement (SAVR) remains the standard of care for patients with chronic severe aortic regurgitation (AR). The introduction of a dedicated transcatheter heart valve for AR has fueled interest in using transcatheter aortic valve replacement to treat patients with isolated AR. We aimed to characterize the profile and outcomes of patients with symptomatic severe AR who underwent isolated SAVR. We conducted a retrospective, observational study of patients who underwent isolated SAVR for symptomatic severe AR at our institution. The primary outcome was in-hospital all-cause mortality. Patients were followed up with 30-day clinical and echocardiographic assessment. A total of 979 patients who underwent SAVR for severe AR between January 2015 and June 2021 were screened for eligibility, of whom 112 patients (11.4%) underwent isolated SAVR for symptomatic severe AR and were included in this analysis. Approximately 25% of patients were deemed to be at intermediate or high risk (n = 26 of 112). The primary outcome occurred in 2.7% of patients (n = 3 of 112). In-hospital stroke occurred in 2.7% of patients (n = 3 of 112), and new-onset atrial fibrillation occurred in 32.1% (n = 36 of 112). At 30-day follow-up, all-cause mortality occurred in 3.6% of patients (n = 4 of 112), and 0.8% (1 of 112) had >mild AR. In conclusion, in a tertiary referral center, the number of patients who underwent isolated SAVR for pure AR represented a small fraction of the overall SAVR patients. The vast majority were low risk and younger when compared with patients with severe aortic stenosis. SAVR yielded excellent short-term mortality and echocardiographic improvements.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
16.
Gen Thorac Cardiovasc Surg ; 71(9): 491-497, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36843184

RESUMO

OBJECTIVE: The use of del Nido cardioplegia (DNC) was initially adopted in the field of pediatric cardiac surgery. Several studies in adult patients suggested there were no differences in early postoperative outcomes as compared to blood-based cardioplegia. We sought to evaluate the impact of DNC as compared to modified Buckberg cardioplegia (BC) on early postoperative outcomes in patients undergoing surgical aortic valve replacement with and without coronary artery bypass grafting (SAVR ± CABG). METHODS: All SAVR ± CABG procedures were switched from BC to DNC at our institute in 2012. We compared outcomes of BC (November 2007-October 2012; n = 1037) with DNC (November 2012-December 2017; n = 1067). Significant baseline differences were observed between the two groups and such differences were adjusted via inverse propensity treatment weighting. RESULTS: After adjustment, SAVR ± CABG patients who received DNC required longer aortic cross-clamp times, while postoperative peak troponin I and creatinine kinase-MB isotype were significantly lower in the BC group. Length of hospital and intensive care unit stay were significantly shorter in the DNC group. The incidence of postoperative complications was lower in the DNC cohort. Thirty-day mortality rate was significantly lower in the DNC group (3.0% vs 4.9%, p = 0.002). CONCLUSIONS: The use of DNC cardioplegia in our cohort of adult patients who underwent SAVR ± CABG was safe and associated with improved postoperative outcomes. However, the use of DNC may be associated with higher degrees of myocardial injury.


Assuntos
Valva Aórtica , Soluções Cardioplégicas , Adulto , Humanos , Criança , Valva Aórtica/cirurgia , Soluções Cardioplégicas/efeitos adversos , Parada Cardíaca Induzida/efeitos adversos , Ponte de Artéria Coronária/efeitos adversos , Período Pós-Operatório , Estudos Retrospectivos , Resultado do Tratamento
17.
Int J Cardiol ; 371: 305-311, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36272571

RESUMO

BACKGROUND: Subclinical leaflet thrombosis (SLT) is characterized on computed tomography (CT) imaging as hypoattenuated leaflet thickening (HALT), reduced leaflet motion (RELM), and hypoattenuation affecting motion (HAM). How antithrombotic regimen type impacts SLT remains poorly understood. We evaluated how antithrombotic regimen type impacts SLT in low-risk subjects following transcatheter aortic valve implantation (TAVI). METHODS: This substudy is a post hoc analysis of the LRT 1.0 and 2.0 trials to assess SLT in subjects who underwent CT or transoesophageal echocardiogram (TOE) imaging at 30 days, stratified by antithrombotic regimen received (single antiplatelet therapy [SAPT], dual antiplatelet therapy [DAPT], or oral anticoagulation). We also utilized univariable logistic regression modelling to identify echocardiographic predictors of HALT. RESULTS: Rates of HALT, RELM, and HAM were all significantly lower with oral anticoagulation compared to SAPT or DAPT at 30 days (HALT: 2.6% vs 14.3% vs 17.2%, respectively, with p < 0.001; RELM: 1.8% vs 9.6% vs 13.1%, respectively, with p = 0.004; and HAM: 0.9% vs 8.5% vs 9.8%, respectively, with p = 0.011). Additionally, short-term oral anticoagulation was not associated with higher bleeding rates compared to SAPT or DAPT (0.8% vs. 1.8% vs. 3.6%, p = 0.291). The presence of HALT did not significantly impact echocardiographic haemodynamic parameters at 30 days. CONCLUSION: This is the largest study to date that evaluated the impact of different antithrombotic regimens on SLT in low-risk TAVI patients. Oral anticoagulation was associated with significantly lower rates of SLT at 30 days compared to DAPT or SAPT, and there was no apparent benefit of DAPT over SAPT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Fibrinolíticos/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Trombose/etiologia , Resultado do Tratamento , Inibidores da Agregação Plaquetária/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia
18.
Heart Rhythm O2 ; 3(4): 396-404, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36097459

RESUMO

Background: Hybrid Convergent ablation for atrial fibrillation (AF) combines minimally invasive surgical (epicardial) and catheter (endocardial) ablation. The procedural goal is to achieve more extensive, enduring ablation of AF substrate around the pulmonary veins, posterior wall, and vestibule of the posterior wall left atrium. Objective: To perform a systematic review and meta-analysis on safety and effectiveness of contemporary Hybrid Convergent procedures. Methods: PubMed, Embase, and manual searches identified primary research articles on Hybrid Convergent. Inclusion criteria focused on contemporary practices (epicardial ablation device and lesions). Clinical outcomes at 1 year or later follow-up, patient population, procedural details, and major adverse events (MAE) were recorded. Results: Of 249 records, 6 studies (5 observational, 1 randomized controlled trial) including 551 patients were included. Endocardial energy sources included radiofrequency and cryoballoon. Hybrid Convergent ablation was mostly performed in patients with drug-refractory persistent and longstanding persistent AF. Mean preprocedural AF duration ranged between 2 and 5.1 years. Most patients (∼92%) underwent Hybrid Convergent in a single hospitalization. At 1 year follow-up or later, 69% (95% confidence interval [CI]: 61%-78%, n = 523) were free from atrial arrhythmias and 50% (95% CI: 42%-58%, n = 343) were free from atrial arrhythmias off antiarrhythmic drugs. Thirty-day MAE rate was 6% (95% CI: 3%-8%, n = 551). Conclusion: Hybrid Convergent ablation is an effective ablation strategy for persistent and longstanding persistent AF. Contemporary procedural approaches and published strategies aim to mitigate complications reported in early experience and address delayed inflammatory effusions.

19.
Catheter Cardiovasc Interv ; 100(3): 404-412, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35723247

RESUMO

OBJECTIVES: Evaluate transcatheter heart valve (THV) geometry according to left ventricular outflow tract (LVOT) calcium degree and its impact on hemodynamics and outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a contemporary self-expanding THV. BACKGROUND: LVOT calcium remains challenging for contemporary THVs. LVOT calcium location and degree may affect THV deployment and impact flow patterns and shear stress, accelerating THV degeneration. METHODS: EPROMPT (CoreValve Evolut Pro Prospective Registry; NCT03423459) is a prospective, investigator-initiated, multicenter registry of patients undergoing TAVR using CoreValve Evolut PRO/PRO + THVs. A total of 107 patients were enrolled in EPROMPT's computed tomography (CT) cohort between January 2018 and October 2021. These patients underwent follow-up CT scan 30 days post-TAVR. We analyzed THV geometry and its interaction with the aortic root following deployment using 30-day post-TAVR CT in patients with none/mild versus moderate/severe LVOT calcium. RESULTS: Thirty-day THV inflows were less eccentric in the short axis in patients with none/mild versus moderate/severe LVOT calcium (1.16 ± 0.09 vs. 1.21 ± 0.12; p = 0.007). THV became more circular and was similar between both cohorts at the THV waist (1.08 ± 0.06 vs. 1.09 ± 0.11; p = 0.551), leaflet tips (1.03 ± 0.04 vs. 1.05 ± 0.09; p = 0.299), and THV outflow (1.04 ± 2.2 vs. 1.03 ± 2.7; p = 0.143). Thirty-day > mild paravalvular leak was low in both cohorts (1.5% vs. 2.4%; p = 0.724); mean gradients were similar (7.7 ± 3.6 vs. 7.7 ± 3.4 mmHg; p = 0.955). CONCLUSIONS: Despite inflow deformities observed in patients with moderate/severe LVOT calcium, Evolut PRO/PRO + conforms to elliptical aortic annuli, maintaining circularity and proper function at the leaflets and outflow, even in patients with moderate/severe LVOT calcium.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Cálcio , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
20.
EuroIntervention ; 18(5): e407-e416, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35321859

RESUMO

BACKGROUND: Given enough time, transcatheter heart valves (THVs) will degenerate and may require reintervention. Redo transcatheter aortic valve implantation (TAVI) is an attractive strategy but carries a risk of coronary obstruction. AIMS: We sought to predict how many TAVIs patients could undergo in their lifetime using computed tomography (CT) simulation. METHODS: We analysed paired CT scans (baseline and 30 days post-TAVI) from patients in the LRT trial and EPROMPT registry. We implanted virtual THVs on baseline CTs, comparing predicted valve-to-coronary (VTC) distances to 30-day CT VTC distances to evaluate the accuracy of CT simulation. We then simulated implantation of a second virtual THV within the first to estimate the risk of coronary obstruction due to sinus sequestration and the need for leaflet modification. RESULTS: We included 213 patients with evaluable paired CTs. There was good agreement between virtual (baseline) and actual (30 days) CT measurements. CT simulation of TAVI followed by redo TAVI predicted low coronary obstruction risk in 25.4% of patients and high risk, likely necessitating leaflet modification, in 27.7%, regardless of THV type. The remaining 46.9% could undergo redo TAVI so long as the first THV was balloon-expandable but would likely require leaflet modification if the first THV was self-expanding. CONCLUSIONS: Using cardiac CT simulation, it is possible to predict whether a patient can undergo multiple TAVI procedures in their lifetime. Those who cannot may prefer to undergo surgery first. CT simulation could provide a personalised lifetime management strategy for younger patients with symptomatic severe aortic stenosis and inform decision-making. CLINICALTRIALS: gov: NCT02628899; ClinicalTrials.gov: NCT03557242; ClinicalTrials.gov: NCT03423459.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Oclusão Coronária/cirurgia , Humanos , Desenho de Prótese , Tomografia , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA