RESUMO
PURPOSE: The purpose of this study was to compare lung image quality obtained with ultra-high resolution (UHR) spectral photon-counting CT (SPCCT) with that of dual-layer CT (DLCT), at standard and low dose levels using an image quality phantom and an anthropomorphic lung phantom. METHODS: An image quality phantom was scanned using a clinical SPCCT prototype and an 8 cm collimation DLCT from the same manufacturer at 10 mGy. Additional acquisitions at 6 mGy were performed with SPCCT only. Images were reconstructed with dedicated high-frequency reconstruction kernels, slice thickness between 0.58 and 0.67 mm, and matrix between 5122 and 10242 mm, using a hybrid iterative algorithm at level 6. Noise power spectrum (NPS), task-based transfer function (TTF) for iodine and air inserts, and detectability index (d') were assessed for ground-glass and solid nodules of 2 mm to simulate highly detailed lung lesions. Subjective analysis of an anthropomorphic lung phantom was performed by two radiologists using a five-point quality score. RESULTS: At 10 mGy, noise magnitude was reduced by 29.1 % with SPCCT images compared to DLCT images for all parameters (27.1 ± 11.0 [standard deviation (SD)] HU vs. 38.2 ± 1.0 [SD] HU, respectively). At 6 mGy with SPCCT images, noise magnitude was reduced by 8.9 % compared to DLCT images at 10 mGy (34.8 ± 14.1 [SD] HU vs. 38.2 ± 1.0 [SD] HU, respectively). At 10 mGy and 6 mGy, average NPS spatial frequency (fav) was greater for SPCCT images (0.75 ± 0.17 [SD] mm-1) compared to DLCT images at 10 mGy (0.55 ± 0.04 [SD] mm-1) while remaining constant from 10 to 6 mGy. At 10 mGy, TTF at 50 % (f50) was greater for SPCCT images (0.92 ± 0.08 [SD] mm-1) compared to DLCT images (0.67 ± 0.06 [SD] mm-1) for both inserts. At 6 mGy, f50 decreased by 1.1 % for SPCCT images, while remaining greater compared to DLCT images at 10 mGy (0.91 ± 0.06 [SD] mm-1 vs. 0.67 ± 0.06 [SD] mm-1, respectively). At both dose levels, d' were greater for SPCCT images compared to DLCT for all clinical tasks. Subjective analysis performed by two radiologists revealed a greater median image quality for SPCCT (5; Q1, 4; Q3, 5) compared to DLCT images (3; Q1, 3; Q3, 3). CONCLUSION: UHR SPCCT outperforms DLCT in terms of image quality for lung imaging. In addition, UHR SPCCT contributes to a 40 % reduction in radiation dose compared to DLCT.
RESUMO
OBJECTIVE: Development of spectral photon-counting computed tomography (SPCCT) for ultra-high-resolution coronary CT angiography (CCTA) has the potential to accurately evaluate the coronary arteries of very-high-risk patients. The aim of this study was to compare the diagnostic performances of SPCCT against conventional CT for quantifying coronary stenosis in very-high-risk patients, with invasive coronary angiography (ICA) as the reference method. MATERIALS AND METHODS: In this prospective institutional review board-approved study, very-high-risk patients addressed for ICA following an acute coronary syndrome were consecutively included. CCTA was performed for each patient with both SPCCT and conventional CT before ICA within 3 days. Stenoses were assessed using the minimal diameter over proximal and distal diameters method for CCTA and the quantitative coronary angiography method for ICA. Intraclass correlation coefficients and mean errors were assessed. Sensitivity and specificity were calculated for a >50% diameter stenosis threshold. Reclassification rates for conventional CT and SPCCT were assessed according to CAD-RADS 2.0, using ICA as the gold standard. RESULTS: Twenty-six coronary stenoses were identified in 26 patients (4 women [15%]; age 64 ± 8 years) with 19 (73%) above 50% and 9 (35%) equal or above 70%. The median stenosis value was 64% (interquartile range, 48%-73%). SPCCT showed a lower mean error (6% [5%, 8%]) than conventional CT (12% [9%, 16%]). SPCCT demonstrated greater sensitivity (100%) and specificity (90%) than conventional CT (75% and 50%, respectively). Ten (38%) stenoses were reclassified with SPCCT and one (4%) with conventional CT. CONCLUSIONS: In very-high-risk patients, ultra-high-resolution SPCCT coronary angiography showed greater accuracy, sensitivity, and specificity, and led to more stenosis reclassifications than conventional CT.
RESUMO
X-Ray imaging techniques are among the most widely used modalities in medical imaging and their constant evolution has led to the emergence of new technologies. The new generation of computed tomography (CT) systems - spectral photonic counting CT (SPCCT) and X-ray luminescence optical imaging - are examples of such powerful techniques. With these new technologies the rising demand for new contrast agents has led to extensive research in the field of nanoparticles and the possibility to merge the modalities appears to be highly attractive. In this work, we propose the design of lanthanide-based nanocrystals as a multimodal contrast agent with the two aforementioned technologies, allowing SPCCT and optical imaging at the same time. We present a systematic study on the effect of the Tb3+ doping level and surface modification on the generation of contrast with SPCCT and the luminescence properties of GdF3:Tb3+ nanocrystals (NCs), comparing different surface grafting with organic ligands and coatings with silica to make these NCs bio-compatible. A comparison of the luminescence properties of these NCs with UV revealed that the best results were obtained for the Gd0.9Tb0.1F3 composition. This property was confirmed under X-ray excitation in microCT and with SPCCT. Moreover, we could demonstrate that the intensity of the luminescence and the excited state lifetime are strongly affected by the surface modification. Furthermore, whatever the chemical nature of the ligand, the contrast with SPCCT did not change. Finally, the successful proof of concept of multimodal imaging was performed in vivo with nude mice in the SPCCT taking advantage of the so-called color K-edge imaging method.
Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Camundongos , Animais , Tomografia Computadorizada por Raios X/métodos , Raios X , Luminescência , Camundongos Nus , Imagens de FantasmasRESUMO
Objective. X-ray spectral computed tomography (CT) allows for material decomposition (MD). This study compared a one-step material decomposition MD algorithm with a two-step reconstruction MD algorithm using acquisitions of a prototype CT scanner with a photon-counting detector (PCD).Approach. MD and CT reconstruction may be done in two successive steps, i.e. decompose the data in material sinograms which are then reconstructed in material CT images, or jointly in a one-step algorithm. The one-step algorithm reconstructed material CT images by maximizing their Poisson log-likelihood in the projection domain with a spatial regularization in the image domain. The two-step algorithm maximized first the Poisson log-likelihood without regularization to decompose the data in material sinograms. These sinograms were then reconstructed into material CT images by least squares minimization, with the same spatial regularization as the one step algorithm. A phantom simulating the CT angiography clinical task was scanned and the data used to measure noise and spatial resolution properties. Low dose carotid CT angiographies of 4 patients were also reconstructed with both algorithms and analyzed by a radiologist. The image quality and diagnostic clinical task were evaluated with a clinical score.Main results. The phantom data processing demonstrated that the one-step algorithm had a better spatial resolution at the same noise level or a decreased noise value at matching spatial resolution. Regularization parameters leading to a fair comparison were selected for the patient data reconstruction. On the patient images, the one-step images received higher scores compared to the two-step algorithm for image quality and diagnostic.Significance. Both phantom and patient data demonstrated how a one-step algorithm improves spectral CT image quality over the implemented two-step algorithm but requires a longer computation time. At a low radiation dose, the one-step algorithm presented good to excellent clinical scores for all the spectral CT images.
Assuntos
Melhoria de Qualidade , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Algoritmos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodosRESUMO
Introduction: To evaluate a reduced iodine volume protocol for lower extremity CT angiography (CTA) using dual-energy CT (DECT). Methods: This retrospective study included consecutive patients who underwent lower extremity CTA from June to December 2022. A 10â ml 1:1 mixed test bolus was performed, followed by a 40â ml full bolus at a 2.5/s injection rate, using 400â mg/ml iodine contrast media. Conventional and 40 keV virtual monoenergetic images (VMI) were reconstructed. For both reconstructions, five main artery segments were assessed with a 3-point image quality score as well as quantitative attenuation, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements with diagnostic quality thresholds (respectively >150â HU and >3). Results: Forty patients were included in the study (mean age 68 ± 12â yo). 200 artery segments were assessed. Median qualitative image scores were 3 [IQR, 3, 3] for both reconstructions. 40 keV VMI upgraded qualitative scores for 51 (26%) of patients, including 9 (5%) from nondiagnostic to diagnostic quality. 40 keV VMI obtained attenuation and CNR diagnostic quality for respectively 100% and 100% of segments, compared with 96% and 98% for conventional images (p < 0.001). Distal artery segments showed the most differences between 40 keV VMI and conventional images. Conclusion: A low-iodine lower extremity CTA protocol is feasible, with 40 keV virtual monoenergetic spectral reconstruction enabling maintained diagnostic image quality at the distal artery segments.
RESUMO
CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.
Assuntos
Artérias , Tomografia Computadorizada por Raios X , Humanos , Artefatos , Brônquios , Meios de ContrasteRESUMO
OBJECTIVES: To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS: A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS: For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION: HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS: ⢠Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. ⢠Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. ⢠In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.
Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Coração , FótonsRESUMO
ABSTRACT: Spectral photon-counting computed tomography (SPCCT) technology holds great promise for becoming the next generation of computed tomography (CT) systems. Its technical characteristics have many advantages over conventional CT imaging. For example, SPCCT provides better spatial resolution, greater dose efficiency for ultra-low-dose and low-dose protocols, and tissue contrast superior to that of conventional CT. In addition, SPCCT takes advantage of several known approaches in the field of spectral CT imaging, such as virtual monochromatic imaging and material decomposition imaging. In addition, SPCCT takes advantage of a new approach in this field, known as K-edge imaging, which allows specific and quantitative imaging of a heavy atom-based contrast agent. Hence, the high potential of SPCCT systems supports their ongoing investigation in clinical research settings. In this review, we propose an overview of our clinical research experience of a whole-body SPCCT clinical prototype, to give an insight into the potential benefits for clinical human imaging on image quality, diagnostic confidence, and new approaches in spectral CT imaging.
Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Tomógrafos ComputadorizadosRESUMO
In chronic thromboembolic pulmonary hypertension (CTEPH), assessment of severity requires right heart catheterization (RHC) through cardiac index (CI). Previous studies have shown that dual-energy CT allows a quantitative assessment of the lung perfusion blood volume (PBV). Therefore, the objective was to evaluate the quantitative PBV as a marker of severity in CTEPH. In the present study, thirty-three patients with CTEPH (22 women, 68.2 ± 14.8 years) were included from May 2017 to September 2021. Mean quantitative PBV was 7.6% ± 3.1 and correlated with CI (r = 0.519, p = 0.002). Mean qualitative PBV was 41.1 ± 13.4 and did not correlate with CI. Quantitative PBV AUC values were 0.795 (95% CI: 0.637-0.953, p = 0.013) for a CI ≥ 2 L/min/m2 and 0.752 (95% CI: 0.575-0.929, p = 0.020) for a CI ≥ 2.5 L/min/m2. In conclusion, quantitative lung PBV outperformed qualitative PBV for its correlation with the cardiac index and may be used as a non-invasive marker of severity in CTPEH patients.
RESUMO
OBJECTIVES: To evaluate short- and long-term safety and efficacy of embolization with Onyx® for recurrent pulmonary arteriovenous malformations (PAVMs) in hereditary hemorrhagic telangiectasia (HHT). METHODS: In total, 45 consecutive patients (51% women, mean (SD) age 53 (18) years) with HHT referred to a reference center for treatment of recurrent PAVM were retrospectively included from April 2014 to July 2021. Inclusion criteria included evidence of PAVM recurrence on CT or angiography, embolization using Onyx® and a minimal 1-year-follow-up CT or angiography. Success was defined based on the standard of reference criteria on unenhanced CT or pulmonary angiography if a recurrence was suspected. PAVMs were analyzed in consensus by two radiologists. The absence of safety distance, as defined by a too-short distance for coil/plug deployment, i.e., between 0.5 and 1 cm, between the proximal extremity of the primary embolic material used and a healthy upstream artery branch, was reported. RESULTS: In total, 70 PAVM were analyzed. Mean (SD) follow-up was 3 (1.3) years. Safety distance criteria were missing in 33 (47%) PAVMs. All procedures were technically successful, with a short-term occlusion rate of 100% using a mean (SD) of 0.6 (0.5) mL of Onyx®. The long-term occlusion rate was 60%. No immediate complication directly related to embolization was reported, nor was any severe long-term complication such as strokes or cerebral abscesses. CONCLUSIONS: In HHT, treatment of recurrent PAVM with Onyx® showed satisfactory safety and efficacy, with an immediate occlusion rate of 100% and a long-term rate of 60%.
RESUMO
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.
Assuntos
Angiografia por Tomografia Computadorizada , Fótons , Angiografia por Tomografia Computadorizada/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodosRESUMO
OBJECTIVES: To compare the lung CT volume (CTvol) and pulmonary function tests in an interstitial lung disease (ILD) population. Then to evaluate the CTvol loss between idiopathic pulmonary fibrosis (IPF) and non-IPF and explore a prognostic value of annual CTvol loss in IPF. METHODS: We conducted in an expert center a retrospective study between 2005 and 2018 on consecutive patients with ILD. CTvol was measured automatically using commercial software based on a deep learning algorithm. In the first group, Spearman correlation coefficients (r) between forced vital capacity (FVC), total lung capacity (TLC), and CTvol were calculated. In a second group, annual CTvol loss was calculated using linear regression analysis and compared with the Mann-Whitney test. In a last group of IPF patients, annual CTvol loss was calculated between baseline and 1-year CTs for investigating with the Youden index a prognostic value of major adverse event at 3 years. Univariate and log-rank tests were calculated. RESULTS: In total, 560 patients (4610 CTs) were analyzed. For 1171 CTs, CTvol was correlated with FVC (r: 0.86) and TLC (r: 0.84) (p < 0.0001). In 408 patients (3332 CT), median annual CTvol loss was 155.7 mL in IPF versus 50.7 mL in non-IPF (p < 0.0001) over 5.03 years. In 73 IPF patients, a relative annual CTvol loss of 7.9% was associated with major adverse events (log-rank, p < 0.0001) in univariate analysis (p < 0.001). CONCLUSIONS: Automated lung CT volume may be an alternative or a complementary biomarker to pulmonary function tests for the assessment of lung volume loss in ILD. KEY POINTS: ⢠There is a good correlation between lung CT volume and forced vital capacity, as well as for with total lung capacity measurements (r of 0.86 and 0.84 respectively, p < 0.0001). ⢠Median annual CT volume loss is significantly higher in patients with idiopathic pulmonary fibrosis than in patients with other fibrotic interstitial lung diseases (155.7 versus 50.7 mL, p < 0.0001). ⢠In idiopathic pulmonary fibrosis, a relative annual CT volume loss higher than 9.4% is associated with a significantly reduced mean survival time at 2.0 years versus 2.8 years (log-rank, p < 0.0001).
Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Medidas de Volume Pulmonar , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Capacidade VitalRESUMO
OBJECTIVES: To evaluate the image quality (IQ) of a spectral photon-counting CT (SPCCT) using filtered back projection (FBP) and hybrid iterative reconstruction (IR) algorithms (iDose4), in comparison with a dual-layer CT (DLCT) system, and to choose the best image quality according to the IR level for SPCCT. METHODS: Two phantoms were scanned using a standard lung protocol (120 kVp, 40 mAs) with SPCCT and DLCT systems. Raw data were reconstructed using FBP and 9 iDose4 levels (i1/i2/i3/i4/i5/i6/i7/i9/i11) for SPCCT and 7 for DLCT (i1/i2/i3/i4/i5/i6/i7). Noise power spectrum and task-based transfer function (TTF) were computed. Detectability index (d') was computed for detection of 4 mm ground-glass nodule (GGN) and solid nodule. Two chest radiologists performed an IQ evaluation (noise/nodule sharpness/nodule conspicuity/overall IQ) in consensus, and chose the best image for SPCCT. RESULTS: Noise magnitude was -47% ± 2% lower on average with SPCCT than with DLCT for iDose4 range from i1 to i6. Average NPS spatial frequencies increased for SPCCT in comparison with DLCT. TTF also increased, except for the air insert with FBP, and i1/i2/i3. Higher detectability was found for SPCCT for both GGN and solid nodules. IQ for both types of nodule was rated consistently higher with SPCCT than with DLCT for the same iDose4 level. For SPCCT and both nodules, the scores for noise and conspicuity improved with increasing iDose4 level. iDose4 level 6 provided the best subjective IQ for both types of nodule. CONCLUSIONS: Higher IQ for GGN and solid nodules was demonstrated with SPCCT compared with DLCT with better detectability using iDose4. KEY POINTS: Using spectral photon-counting CT compared with dual-layer CT, noise magnitude was reduced with improvements in spatial resolution and detectability of ground-glass nodules and solid lung nodules. As the iDose4 level increased, noise magnitude was reduced and detectability of ground-glass and solid lung nodules was better for both CT systems. For spectral photon-counting CT imaging, two chest radiologists determined iDose4 level 6 as the best image quality for detecting ground-glass nodules and solid lung nodules.
Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Humanos , Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Doses de RadiaçãoRESUMO
OBJECTIVES: The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). MATERIALS AND METHODS: In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. RESULTS: Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. CONCLUSION: Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.
Assuntos
Angiografia por Tomografia Computadorizada , Platina , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Humanos , Masculino , Imagens de Fantasmas , Fótons , Estudos Retrospectivos , Stents , Tomografia Computadorizada por Raios X/métodosRESUMO
AIMS: To evaluate spectral photon-counting CT's (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. METHODS: We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d') of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. RESULTS: SPCCT provided lower noise magnitude (9-38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30-33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d'. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d' (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. CONCLUSIONS: SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.