Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Clin Med ; 13(10)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38792297

RESUMO

Introduction: The efficacy of de novo cardiac resynchronisation therapy (CRT) in patients with heart failure (HF), left ventricular systolic dysfunction (LVSD), and a broad QRS morphology is well established. However, the optimal stage for upgrading patients with existing pacemakers (PPMs) or implantable cardioverter-defibrillators (ICDs) and HF with high-burden right ventricular (RV) pacing remains uncertain. Thus, this multicentre retrospective analysis compared patients with pre-existing PPMs or ICDs who underwent CRT upgrades to investigate the appropriate stage for CRT implantation in these patients and to assess the validity of treating both PPM and ICD recipients under the same recommendation level in the current guidelines. Materials and Methods: A total of 151 participants underwent analysis in this study, comprising 93 upgrades to cardiac resynchronisation therapy with pacemaker (CRT-P) and 58 upgrades to cardiac resynchronisation therapy with defibrillator (CRT-D) across three centres in the UK. The aim of the study was to investigate the safety and efficacy of upgrading to CRT from an existing conventional pacemaker or an ICD in the context of high-burden RV pacing. The analysis was conducted separately for each group, assessing changes in echocardiographic parameters, functional New York Heart Association (NYHA) class, and procedure-related complications. Results: The PPM group had a higher percentage RVP burden compared to the ICD group. Post-upgrade, NYHA functional class and EF and LV volumes improved in both groups; however, the response to an upgrade from a pacemaker was greater compared to an upgrade from an ICD. Post-procedural complication risks were similar across the two subgroups but significantly higher compared to de novo implantation. Conclusions: Within the CRT-P subgroup, participants exhibited better responses than their CRT-D counterparts, evident both in echocardiographic improvements and clinical outcomes. Furthermore, patients with non-ischemic cardiomyopathy (NICM) were better responders than those with ischaemic cardiomyopathy. These findings suggest that international guidelines should consider approaching each subgroup separately in the future.

2.
Heart Rhythm ; 20(12): 1629-1636, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37516414

RESUMO

BACKGROUND: Biventricular endocardial pacing (BiV-endo) and left bundle branch area pacing (LBBAP) are novel methods of delivering cardiac resynchronization therapy. These techniques are associated with improved activation times and acute hemodynamic response compared with conventional biventricular epicardial pacing (BiV-epi); however, the effects on repolarization and arrhythmic risk are unknown. OBJECTIVE: The purpose of this study was to compare the effects of temporary BiV-epi, BiV-endo, and LBBAP on epicardial left ventricular (LV) repolarization using electrocardiographic imaging (ECGi). METHODS: Eleven patients indicated for cardiac resynchronization therapy underwent a temporary pacing protocol with ECGi. BiV-endo was delivered via endocardial stimulation of the LV lateral wall. LBBAP was delivered by pacing the LV septum. Epicardial LV repolarization time (LVRT-95; time taken for 95% of the LV to repolarize), LV RT dispersion, mean LV activation recovery interval (ARI), LV ARI dispersion, and RT gradients were calculated. RESULTS: The protocol was completed in 10 patients. During LBBAP, there were significant reductions in LVRT-95 (94.9 ± 17.4 ms vs 125.0 ± 29.4 ms; P = .03) and LV RT dispersion (29.4 ± 6.3 ms vs 40.8 ± 11.4 ms; P = .015) compared with BiV-epi. In contrast, there were no significant differences between baseline, BiV-epi, or BiV-endo. There was a nonsignificant reduction in mean RT gradients between LBBAP and baseline rhythm (0.74 ± 0.22 ms/mm vs 1.01 ± 0.31 ms/mm; P = .07). There were no significant differences in mean LV ARI or LV ARI dispersion between groups. CONCLUSION: Temporary LBBAP reduces epicardial dispersion of repolarization compared with conventional BiV-epi. Further study is required to determine whether these repolarization changes on ECGi translate into a reduced risk of ventricular arrhythmia in clinical practice.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Septo Interventricular , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Arritmias Cardíacas/terapia , Ventrículos do Coração , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
3.
Heart Rhythm ; 20(2): 207-216, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36575808

RESUMO

BACKGROUND: Biventricular endocardial pacing (BiV-endo) has demonstrated superior cardiac resynchronization compared to conventional biventricular epicardial pacing (BiV-epi). Left bundle branch area pacing (LBBAP) may also achieve effective cardiac resynchronization therapy (CRT). OBJECTIVE: The purpose of this study was to compare the acute electrical and hemodynamic effects of BiV-epi, BiV-endo, and LBBAP delivered from the LV endocardium and to assess how myocardial scar affects response. METHODS: Eleven patients with heart failure and indications for CRT underwent a temporary pacing study with electrocardiographic imaging (ECGi) and hemodynamic assessment. BiV-endo was delivered by stimulation of the left ventricular (LV) lateral wall, and LBBAP was delivered by stimulation of the LV septum, at the site of a Purkinje potential. LV activation time (LVAT-95), LV dyssynchrony index (LVDI), biventricular activation time (BIVAT-90), and biventricular dyssynchrony index (BIVDI) were calculated. Myocardial scar was assessed using magnetic resonance imaging (MRI). RESULTS: The protocol was completed in 10 patients. Compared to BiV-epi (LVAT-95: 79.2 ± 13.1 ms; LVDI: 26.6 ± 3.4 ms) LV resynchronization was superior during BiV-endo (LVAT-95: 48.5 ± 14.9 ms; P = .001; LVDI: 16.6 ± 6.4 ms; P = .002) and LBBAP (LVAT-95: 48.9 ± 12.5 ms; P = .001; LVDI: 15.3 ± 3.4 ms; P = .001). Biventricular resynchronization was similarly superior during BiV-endo and LBBAP vs BiV-epi (BIVAT-90 and BIVDI; P <.05). The rate of acute hemodynamic responders was higher during BiV-endo (90%) and LBBAP (70%) vs BiV-epi (50%). The benefits of LBBAP (but not BiV-endo) on LV resynchronization were attenuated when septal scar was present in a subset of 8 patients who underwent MRI. CONCLUSION: Our findings suggest superior electrical resynchronization and a higher proportion of acute hemodynamic responders during BiV-endo and LBBAP compared to BiV-epi. Electrical resynchronization was similar between BiV-endo and LBBAP; however, septal scar seemed to attenuate response to LBBAP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Endocárdio , Cicatriz/terapia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Imageamento por Ressonância Magnética , Hemodinâmica/fisiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Resultado do Tratamento
4.
Diving Hyperb Med ; 52(3): 217-220, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36100934

RESUMO

Immersion pulmonary oedema (IPO) can affect sea swimmers, snorkelers, and scuba divers. It can be fatal and cases are often mistaken for drowning. There has been an association between IPO and the development of takotsubo cardiomyopathy. We present a case study of a diver rescued from the water with IPO, who was subsequently found to have takotsubo cardiomyopathy on cardiac magnetic resonance imaging (CMR). This case demonstrates CMR findings as well as follow- up investigation results. The diver's and instructor's perspective during the initial dive incident are also described.


Assuntos
Mergulho , Edema Pulmonar , Cardiomiopatia de Takotsubo , Mergulho/efeitos adversos , Humanos , Imageamento por Ressonância Magnética/métodos , Edema Pulmonar/diagnóstico por imagem , Edema Pulmonar/etiologia , Cardiomiopatia de Takotsubo/diagnóstico por imagem
5.
Europace ; 24(5): 796-806, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-35079787

RESUMO

AIMS: To determine whether triventricular (TriV) pacing is feasible and improves CRT response compared to conventional biventricular (BiV) pacing in patients with left bundle branch block (LBBB) and intermediate QRS prolongation (120-150 ms). METHODS AND RESULTS: Between October 2015 and November 2019, 99 patients were recruited from 11 UK centres. Ninety-five patients were randomized 1:1 to receive TriV or BiV pacing systems. The primary endpoint was feasibility of TriV pacing. Secondary endpoints assessed symptomatic and remodelling response to CRT. Baseline characteristics were balanced between groups. In the TriV group, 43/46 (93.5%) patients underwent successful implantation vs. 47/49 (95.9%) in the BiV group. Feasibility of maintaining CRT at 6 months was similar in the TriV vs. BiV group (90.0% vs. 97.7%, P = 0.191). All-cause mortality was similar between TriV vs. BiV groups (4.3% vs. 8.2%, P = 0.678). There were no significant differences in echocardiographic LV volumes or clinical composite scores from baseline to 6-month follow-up between groups. CONCLUSION: Implantation of two LV leads to deliver and maintain TriV pacing at 6 months is feasible without significant complications in the majority of patients. There was no evidence that TriV pacing improves CRT response or provides additional clinical benefit to patients with LBBB and intermediate QRS prolongation and cannot be recommended in this patient group. CLINICAL TRIAL REGISTRATION NUMBER: Clinicaltrials.gov: NCT02529410.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 32(3): 802-812, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33484216

RESUMO

BACKGROUND: Optimal positioning of the left ventricular (LV) lead is an important determinant of cardiac resynchronization therapy (CRT) response. OBJECTIVE: Evaluate the feasibility of intraprocedural integration of cardiac computed tomography (CT) to guide LV lead implantation for CRT upgrades. METHODS: Patients undergoing LV lead upgrade underwent ECG-gated cardiac CT dyssynchrony and LV scar assessment. Target American Heart Association segment selection was determined using latest non-scarred mechanically activating segments overlaid onto real-time fluoroscopy with image co-registration to guide optimal LV lead implantation. Hemodynamic validation was performed using a pressure wire in the LV cavity (dP/dtmax) ). RESULTS: 18 patients (male 94%, 55.6% ischemic cardiomyopathy) with RV pacing burden 60.0 ± 43.7% and mean QRS duration 154 ± 30 ms underwent cardiac CT. 10/10 ischemic patients had CT evidence of scar and these segments were excluded as targets. Seventeen out of 18 (94%) patients underwent successful LV lead implantation with delivery to the CT target segment in 15 out of 18 (83%) of patients. Acute hemodynamic response (dP/dtmax ≥ 10%) was superior with LV stimulation in CT target versus nontarget segments (83.3% vs. 25.0%; p = .012). Reverse remodeling at 6 months (LV end-systolic volume improvement ≥15%) occurred in 60% of subjects (4/8 [50.0%] ischemic cardiomyopathy vs. 5/7 [71.4%] nonischemic cardiomyopathy, p = .608). CONCLUSION: Intraprocedural integration of cardiac CT to guide optimal LV lead placement is feasible with superior hemodynamics when pacing in CT target segments and favorable volumetric response rates, despite a high proportion of patients with ischemic cardiomyopathy. Multicentre, randomized controlled studies are needed to evaluate whether intraprocedural integration of cardiac CT is superior to standard care.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 43(7): 737-745, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32469085

RESUMO

BACKGROUND: Antitachycardia pacing (ATP), which may avoid unnecessary implantable cardioverter-defibrillator (ICD) shocks, does not always terminate ventricular arrhythmias (VAs). Mean entropy calculated using cardiac magnetic resonance texture analysis (CMR-TA) has been shown to predict appropriate ICD therapy. We examined whether scar heterogeneity, quantified by mean entropy, is associated with ATP failure and explore potential mechanisms using computer modeling. METHODS: A subanalysis of 114 patients undergoing CMR-TA where the primary endpoint was delivery of appropriate ICD therapy (ATP or shock therapy) was performed. Patients receiving appropriate ICD therapy (n = 33) were dichotomized into "successful ATP" versus "shock therapy" groups. In silico computer modeling was used to explore underlying mechanisms. RESULTS: A total of 16 of 33 (48.5%) patients had successful ATP to terminate VA, and 17 of 33 (51.5%) patients required shock therapy. Mean entropy was significantly higher in the shock versus successful ATP group (6.1 ± 0.5 vs 5.5 ± 0.7, P = .037). Analysis of patients receiving ATP (n = 22) showed significantly higher mean entropy in the six of 22 patients that failed ATP (followed by rescue ICD shock) compared to 16 of 22 that had successful ATP (6.3 ± 0.7 vs 5.5 ± 0.7, P = .048). Computer modeling suggested inability of the paced wavefront in ATP to successfully propagate from the electrode site through patchy fibrosis as a possible mechanism of failed ATP. CONCLUSIONS: Our findings suggest lower scar heterogeneity (mean entropy) is associated with successful ATP, whereas higher scar heterogeneity is associated with more aggressive VAs unresponsive to ATP requiring shock therapy that may be due to inability of the paced wavefront to propagate through scar and terminate the VA circuit.


Assuntos
Cicatriz/fisiopatologia , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/terapia , Simulação por Computador , Desfibriladores Implantáveis , Entropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento
8.
Heart Rhythm ; 17(8): 1291-1297, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32165181

RESUMO

BACKGROUND: Biventricular endocardial pacing (BiV ENDO) is a therapy for heart failure patients who cannot receive transvenous epicardial cardiac resynchronization therapy (CRT) or have not responded adequately to CRT. BiV ENDO CRT can be delivered by a new wireless LV ENDO pacing system (WiSE-CRT system; EBR Systems, Sunnyvale, CA), without the requirement for lifelong anticoagulation. OBJECTIVE: The purpose of this study was to assess the safety and efficacy of the WiSE-CRT system during real-world clinical use in an international registry. METHODS: Data were prospectively collected from 14 centers implanting the WiSE-CRT system as part of the WiCS-LV Post Market Surveillance Registry. (ClinicalTrials.gov Identifier: NCT02610673). RESULTS: Ninety patients from 14 European centers underwent implantation with the WiSE-CRT system. Patients were predominantly male, age 68.2 ± 10.5 years, left ventricular ejection fraction 30.6% ± 8.9%, mean QRS duration 180.7 ± 27.0 ms, and 40% with ischemic etiology. Successful implantation and delivery of BiV ENDO pacing was achieved in 94.4% of patients. Acute (<24 hours), 1- to 30-day, and 1- to 6-month complications rates were 4.4%, 18.8%, and 6.7%, respectively. Five deaths (5.6%) occurred within 6 months (3 procedure related). Seventy percent of patients had improvement in heart failure symptoms. CONCLUSION: BiV ENDO pacing with the WiSE-CRT system seems to be technically feasible, with a high success rate. Three procedural deaths occurred during the study. Procedural complications mandate adequate operator training and implantation at centers with immediately available cardiothoracic and vascular surgical support.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Sistema de Registros , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Endocárdio , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
9.
Heart ; 106(12): 931-937, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31932286

RESUMO

OBJECTIVES: Transvenous lead extraction (TLE) poses a significant economic and resource burden on healthcare systems; however, limited data exist on its true cost. We therefore estimate real-world healthcare reimbursement costs of TLE to the UK healthcare system at a single extraction centre. METHODS: Consecutive admissions entailing TLE at a high-volume UK centre between April 2013 and March 2018 were prospectively recorded in a computer registry. In the hospital's National Health Service (NHS) clinical coding/reimbursement database, 447 cases were identified. Mean reimbursement cost (n=445) and length of stay (n=447) were calculated. Ordinary least squares regressions estimated the relationship between cost (bed days) and clinical factors. RESULTS: Mean reimbursement cost per admission was £17 399.09±£13 966.49. Total reimbursement for all TLE admissions was £7 777 393.51. Mean length of stay was 16.3±15.16 days with a total of 7199 bed days. Implantable cardioverter-defibrillator and cardiac resynchronisation therapy defibrillator devices incurred higher reimbursement costs (70.5% and 68.7% higher, respectively, both p<0.001). Heart failure and prior valve surgery also incurred significantly higher reimbursement costs. Prior valve surgery and heart failure were associated with 8.3 (p=0.017) and 5.5 (p=0.021) additional days in hospital, respectively. CONCLUSIONS: Financial costs to the NHS from TLE are substantial. Consideration should therefore be given to cost/resource-sparing potential of leadless/extravascular cardiac devices that negate the need for TLE particularly in patients with prior valve surgery and/or heart failure. Additionally, use of antibiotic envelopes and other interventions that reduce infection risk in patients receiving transvenous leads should be considered.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/economia , Recursos em Saúde/economia , Custos Hospitalares , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Medicina Estatal/economia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Análise Custo-Benefício , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Reembolso de Seguro de Saúde , Tempo de Internação/economia , Londres , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/economia , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 42(10): 1355-1364, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31433064

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) may be performed by superior approach using the original implant vein or via a femoral approach; however, limited comparative data exists. We compare outcomes between femoral versus nonfemoral TLE approaches and determine predictors of bailout transfemoral lead extraction in patients undergoing initial TLE via the original implant vein by a superior approach. METHODS: All consecutive TLEs between October 2000 and March 2018 were prospectively collected (n = 1052). Patients were dichotomized into femoral (n = 118) and nonfemoral (n = 934) groups. RESULTS: Demographics were balanced between femoral vs nonfemoral groups. Patients in the femoral group had significantly higher mean lead dwell times (11.6 ± 9.7 vs 6.6 ± 6.6 years, P < .001), mean number of leads extracted (2.7 ± 1.3 vs 2.0 ± 1.0, P < .001), 30-day procedure related major complications (including deaths) (8.5% vs 1.1%, P < .001) and emergency thoracotomy rates (4.2% vs 0.7%, P = .007). All-cause 30-day mortality rates were similar between groups (3.4% vs 2.0%, P = .315). Prolonged lead dwell time and increased number of leads extracted were predictive of a bailout transfemoral approach at multivariable analysis. CONCLUSION: Femoral approach TLE is associated with increased risk of 30-day procedure related major complications but not 30-day all-cause mortality. Prolonged lead dwell time and increased number of leads extracted are independent predictors for bailout transfemoral lead extraction. Such patients should be considered high risk of major complications and performed by high-volume lead extraction centers with experience in multiple approaches and techniques including experience with transfemoral lead extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Idoso , Desenho de Equipamento , Falha de Equipamento , Veia Femoral , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo
11.
J Arrhythm ; 35(2): 267-275, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31007792

RESUMO

AIM: Quadripolar lead technology and multi-point pacing (MPP) are important clinical adjuncts in cardiac resynchronization therapy (CRT) pacing aimed at reducing the rate of non-response to therapy. Mixed results have been achieved using MPP and it is critical to identify which patients require this approach and how to configure their MPP stimulation, in order to achieve optimal electrical resynchronization. METHODS & RESULTS: We sought to investigate whether electrocardiographic imaging (ECGi), using the CARDIOINSIGHT ™ inverse ECG mapping system, could identify alterations in electrical resynchronization during different methods of device optimization. In no patient did a single form of programming optimization provide the best electrical response. The effects of utilizing MPP were idiosyncratic and highly patient specific. ECGi activation maps were clearly able to discern changes in bulk LV activation during differing MPP programming. In two of the five subjects, MPP resulted in more rapid activation of the left ventricle compared to standard CRT; however, in the remaining three patients, the use of MPP did not appear to acutely improve electrical resynchronization. Crucially, this cohort showed evidence of extensive LV scarring which was well visualized using both CMR and ECGi voltage mapping. CONCLUSIONS: Our work suggests a potential role for ECGi in the optimization of non-responders to CRT, as it allows the fusion of activation maps and scar analysis above and beyond interrogation of the 12 lead ECG.

12.
Heart Rhythm ; 16(8): 1242-1250, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30849532

RESUMO

BACKGROUND: Risk stratification of ventricular arrhythmia remains complex in patients with ischemic and nonischemic cardiomyopathy. OBJECTIVE: The purpose of this study was to determine whether scar heterogeneity, quantified by mean entropy, predicts appropriate implantable cardioverter-defibrillator (ICD) therapy. We hypothesized that higher mean entropy calculated from cardiac magnetic resonance texture analysis (CMR-TA) will predict appropriate ICD therapy. METHODS: Consecutive patients underwent CMR imaging before ICD implantation. Short-axis left ventricular scar was manually segmented. CMR-TA was performed using a Laplacian filter to extract and augment image features to create a scar texture from which histogram analysis of pixel intensity was used to calculate mean entropy. The primary end point was appropriate ICD therapy. RESULTS: A total of 114 patients underwent CMR-TA (ischemic cardiomyopathy [ICM]: n = 70; nonischemic cardiomyopathy [NICM]: n = 44) with a median follow-up of 955 days (interquartile range 691-1185 days). Mean entropy was significantly higher in the ICM group (5.7 ± 0.7 vs 5.5 ± 0.7; P= .045). Overall, 33 patients received appropriate ICD therapy. Using optimized cutoff values from receiver operating characteristic curves, Kaplan-Meier survival analysis demonstrated time until first appropriate therapy was significantly shorter in the high mean entropy group (P = .003). Multivariable analysis showed that mean entropy was the sole predictor of appropriate ICD therapy (hazard ratio 1.882; 95% confidence interval 1.083-3.271; P = .025). In the ICM group, mean entropy remained an independent predictor of appropriate ICD therapy, whereas in the NICM group, precontrast T1 values were the sole predictor. CONCLUSION: Scar heterogeneity, quantified by mean entropy using CMR-TA, was an independent predictor of appropriate ICD therapy in the mixed cardiomyopathy cohort and ICM-only group, suggesting a potential role for CMR-TA in predicting ventricular arrhythmia and risk-stratifying patients for ICD implantation.


Assuntos
Cardiomiopatias/diagnóstico , Cicatriz/patologia , Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Taquicardia Ventricular/terapia , Idoso , Cardiomiopatias/complicações , Entropia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico
13.
Heart Fail Rev ; 24(1): 41-54, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30143910

RESUMO

Heart failure is a complex clinical syndrome associated with a significant morbidity and mortality burden. Reductions in left ventricular (LV) function trigger adaptive mechanisms, leading to structural changes within the LV and the potential development of dyssynchronous ventricular activation. This is the substrate targeted during cardiac resynchronisation therapy (CRT); however, around 30-50% of patients do not experience benefit from this treatment. Non-response occurs as a result of pre-implant, peri-implant and post implant factors but the technical constraints of traditional, transvenous epicardial CRT mean they can be challenging to overcome. In an effort to improve response, novel alternative methods of CRT delivery have been developed and of these endocardial pacing, where the LV is stimulated from inside the LV cavity, appears the most promising.


Assuntos
Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/terapia , Endocárdio/metabolismo , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pericárdio/metabolismo , Fatores Sexuais , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
14.
Pacing Clin Electrophysiol ; 42(1): 73-84, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30411817

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) may be necessary due to infective and noninfective indications. We aim to identify predictors of 30-day mortality and risk factors between infective versus noninfective groups and systemic versus local infection subgroups. METHODS: A total of 925 TLEs between October 2000 and December 2016 were prospectively collected and dichotomized (infective group n = 505 vs noninfective group n = 420 and systemic infection n = 164 vs local infection n = 341). RESULTS: All-cause major complication including deaths was significantly higher (5.1%, n = 26 vs 1.2%, n = 5, P = 0.001) as well as 30-day mortality (4.0%, n = 20 vs 0.2%, n = 1, P < 0.001) in the infective group compared to the noninfective group. Both subgroups (systemic vs local infection) were balanced for demographics. All-cause major complication including deaths was significantly higher (9.1%, n = 15 vs 3.2%, n = 11, P = 0.008) as well as all-cause 30-day mortality (7.9%, n  = 13 vs 2.1%, n = 7, P = 0.003) in the systemic infection subgroup compared to the local infection subgroup. CONCLUSION: Patients undergoing TLE for infective indications are at greater risk of 30-day all-cause mortality compared to noninfective patients. Patients undergoing TLE for systemic infective indications are at greater risk of 30-day all-cause mortality compared to patients with local infection. Renal impairment, systemic infection, and elevated preprocedure C-reactive protein are independent predictors of 30-day all-cause mortality in patients undergoing TLE for an infective indication.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/mortalidade , Idoso , Causas de Morte , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco
15.
Heart Rhythm ; 16(5): 702-709, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30528448

RESUMO

BACKGROUND: Enhanced beat-to-beat variability of repolarization is strongly linked to arrhythmogenesis and is largely due to variation in ventricular action potential duration (APD). Previous studies in humans have relied on QT interval measurements; however, a direct relationship between beat-to-beat variability of APD and arrhythmogenesis in humans has yet to be demonstrated. OBJECTIVE: This study aimed to explore the beat-to-beat repolarization dynamics in patients with heart failure at the level of ventricular APD. METHODS: Forty-three patients with heart failure and implanted cardiac resynchronization therapy - defibrillator devices were studied. Activation-recovery intervals as a surrogate for APD were recorded from the left ventricular epicardial lead while pacing from the right ventricular lead to maintain a constant cycle length. RESULTS: During a mean follow-up of 23.6±13.6 months, 11 patients sustained ventricular fibrillation/ventricular tachycardia (VT/VF) and received appropriate implantable cardioverter-defibrillator therapies (antitachycardia pacing or shock therapy). Activation-recovery interval variability (ARIV) was significantly greater in patients with subsequent VT/VF than in those without VT/VF (3.55±1.3 ms vs 2.77±1.09 ms; P=.047). Receiver operating characteristic curve analysis (area under the curve 0.71; P=.046) suggested high- and low-risk ARIV groups for VT/VF. Kaplan-Meier survival analysis demonstrated that the time until first appropriate therapy for VT/VF was significantly shorter in the high-risk ARIV group (P=.028). ARIV was a predictor for VT/VF in the multivariate Cox model (hazard ratio 1.623; 95% confidence interval 1.1-2.393; P=.015). CONCLUSION: Increased left ventricular ARIV is associated with an increased risk of VT/VF in patients with heart failure.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular , Análise de Variância , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
16.
Europace ; 21(6): 928-936, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590509

RESUMO

AIMS: Transvenous lead extraction (TLE) may be necessary due to system infection/erosion or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may be at greater risk due to increased comorbidities. We examined whether patients with CRT systems undergoing TLE had more comorbidities and higher 30-day mortality than those with non-CRT devices. METHODS AND RESULTS: All TLEs between October 2000 and December 2016 were prospectively collected. During this period 925 TLEs occurred (CRT group 231, non-CRT group 694). Cardiac resynchronization therapy patients were older (68.1 ± 10.8 years vs. 64.3 ± 16.1 years, P = 0.024); more likely male (85.7% vs. 69%, P < 0.001); had lower mean left ventricular ejection fraction (34.1 ± 12.7% vs. 48.3 ± 12.9%, P < 0.001); had higher prevalence of renal impairment (33.8% vs. 13.7%, P < 0.001) and were more likely to have ≥2 comorbidities (84% vs. 40.1%, P < 0.001). Mean lead dwell time was lower in the CRT group (5.6 ± 5.5 years vs. 7.6 ± 7.1 years, P = 0.002). There was no significant difference in all-cause 30-day mortality rates between CRT (3.0%, n = 7) and non-CRT patients (2.0%, n = 14) (P = 0.443). The majority of deaths in both groups were due to sepsis. Univariate and multivariate analysis showed age, renal impairment and sepsis were associated with increased risk of 30-day mortality. Transvenous lead extraction of a CRT system did not predict 30-day mortality. CONCLUSION: Transvenous lead extraction in CRT patients was not associated with increased 30-day mortality when compared with non-CRT patients. Age, renal impairment and sepsis were independent predictors of 30-day mortality. Sepsis was the main cause of 30-day mortality.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo , Mortalidade/tendências , Idoso , Causas de Morte , Comorbidade , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
17.
J Cardiovasc Electrophysiol ; 29(12): 1675-1681, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30106206

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is typically delivered via quadripolar leads that allow stimulation using either true bipolar pacing, where stimulation occurs between two electrodes (BP) on the quadripolar lead, or extended bipole (EBP) left ventricular (LV) pacing, with the quadripolar electrodes and right ventricular coil acting as the cathode and anode, respectively. True bipolar pacing is associated with reductions in mortality and it has been postulated that these differences are the result of enhanced electrical activation. MATERIALS AND METHODS: Patients undergoing a CRT underwent an electrocardiographic imaging study where electrical activation data were recorded while different LV pacing vectors were temporarily programmed. RESULTS: There were no differences in the total electrical activation times or dispersion of electrical activation between biventricular pacing with bipolar or corresponding EBP LV vector configurations (left ventricular total activation time [LVtat] BP 74.70 ± 18.07 vs EBP 72.4 ± 22.64; P = 0.45). When dichotomized according to etiology, no difference was observed in the activation time with either BP or EBP pacing (LVtat BP ischemic cardiomyopathy 72.2 ± 17.4 vs BP dilated cardiomyopathy 79.9 ± 18.9; P = 0.38). CONCLUSIONS: Bipolar pacing alters the mechanical activation sequence of the LV and is associated with reductions in all-cause mortality. It has been postulated these benefits derive from improvements in electromechanical activation of the LV. Our study would suggest that true bipolar pacing does not necessarily result in more favorable activation of the LV or improved electrical resynchronization and other mechanisms should be explored.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Cardiopatias/fisiopatologia , Cardiopatias/cirurgia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
18.
Expert Rev Med Devices ; 15(8): 555-570, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30019954

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) has emerged as one of the few effective treatments for heart failure. However, up to 50% of patients derive no benefit. Suboptimal left ventricle (LV) lead position is a potential cause of poor outcomes while targeted lead deployment has been associated with enhanced response rates. Image-fusion guidance systems represent a novel approach to CRT delivery, allowing physicians to both accurately track and target a specific location during LV lead deployment. AREAS COVERED: This review will provide a comprehensive evaluation of how to define the optimal pacing site. We will evaluate the evidence for delivering targeted LV stimulation at sites displaying favorable viability or advantageous mechanical or electrical properties. Finally, we will evaluate several emerging image-fusion guidance systems which aim to facilitate optimal site selection during CRT. EXPERT COMMENTARY: Targeted LV lead deployment is associated with reductions in morbidity and mortality. Assessment of tissue characterization and electrical latency are critical and can be achieved in a number of ways. Ultimately, the constraints of coronary sinus anatomy have forced the exploration of novel means of delivering CRT including endocardial pacing which hold promise for the future of CRT delivery.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Imageamento Tridimensional , Biomarcadores/metabolismo , Endocárdio/patologia , Ventrículos do Coração/patologia , Humanos , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 4(7): 860-868, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30025684

RESUMO

OBJECTIVES: This study hypothesized that guided implants, in which the optimal left ventricular endocardial (LVENDO) pacing location was identified and targeted, would improve acute markers of contractility and chronic markers of cardiac resynchronization (CRT) response. BACKGROUND: Biventricular endocardial (BiVENDO) pacing may offer a potential benefit over standard CRT; however, the optimal LVENDO pacing site is highly variable. Indiscriminately delivered BiVENDO pacing is associated with a reverse remodeling response rate of between 40% and 60%. METHODS: Registry of centers implanting a wireless, LVENDO pacing system (WiSE-CRT System, EBR Systems, Sunnyvale, California); John Radcliffe Hospital (Oxford, United Kingdom), Guy's and St. Thomas' Hospital (London, United Kingdom), and The James Cook University Hospital (Middlesbrough, United Kingdom). Centers used a combination of preprocedural imaging and electroanatomical mapping the identify the optimal LVENDO site. RESULTS: A total of 26 patients across the 3 centers underwent a guided implant. Patients were predominantly male with a mean age of 68.8 ± 8.4 years, the mean LV ejection fraction was 34.2 ± 7.8%. The mean QRS duration was 163.8 ± 26.7 ms, and 30.8% of patients had an ischemic etiology. It proved technically feasible to selectively target and deploy the pacing electrode in a chosen endocardial segment in almost all cases, with a similar complication rate to that observed during indiscriminate BiVENDO. Ninety percent of patients met the definition of echocardiographic responder. Reverse remodeling was observed in 71%. CONCLUSIONS: Guided endocardial implants were associated with a higher degree of chronic LV remodeling compared with historical nonguided approaches.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Ventrículos do Coração , Hemodinâmica/fisiologia , Cirurgia Assistida por Computador/métodos , Idoso , Terapia de Ressincronização Cardíaca , Eletrocardiografia , Eletrodos Implantados , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Tecnologia sem Fio
20.
Expert Rev Cardiovasc Ther ; 16(8): 607-615, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29985076

RESUMO

INTRODUCTION: A significant number of patients undergo upgrade to cardiac resynchronization therapy (CRT). These patients tend to differ from individuals undergoing de novo CRT implantations both in terms of their baseline demographics and the etiology underlying their heart failure. Areas covered: There are several factors that need to be considered when upgrading patients to CRT, such as, venous patency. Potentially, these conditions can cause issues which may result in procedures being more difficult than de novo implantations. This article discusses these issues and compares the rates of procedural-related complications for CRT upgrades and de novo implantations. It discusses the proportion of patients that are likely to respond to CRT with each intervention. Expert commentary: Understanding the relative risks of CRT upgrades versus de novo implantations is important to help operators select the correct initial device and counsel patients accordingly. Growing experience with image-guided implantations and endocardial pacing may prove to be particularly relevant to patients undergoing CRT upgrades.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA