Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
2.
Circ Arrhythm Electrophysiol ; 16(9): e011861, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37589197

RESUMO

BACKGROUND: Ablation for persistent atrial fibrillation (PsAF) has been performed for over 20 years, although success rates have remained modest. Several adjunctive lesion sets have been studied but none have become standard of practice. We sought to describe how the efficacy of ablation for PsAF has evolved in this time period with a focus on the effect of adjunctive ablation strategies. METHODS: Databases were searched for prospective studies of PsAF ablation. We performed meta-regression and trial sequential analysis. RESULTS: A total of 99 studies (15 424 patients) were included. Ablation for PsAF achieved the primary outcome (freedom of atrial fibrillation/atrial tachycardia rate at 12 months follow-up) in 48.2% (5% CI, 44.0-52.3). Meta-regression showed freedom from atrial arrhythmia at 12 months has improved over time, while procedure time and fluoroscopy time have significantly reduced. Through the use of cumulative meta-analyses and trial sequential analysis, we show that some ablation strategies may initially seem promising, but after several randomized controlled trials may be found to be ineffective. Trial sequential analysis showed that complex fractionated atrial electrogram ablation is ineffective and further study of this treatment would be futile, while posterior wall isolation currently does not have sufficient evidence for routine use in PsAF ablation. CONCLUSIONS: Overall success rates from PsAF ablation and procedure/fluoroscopy times have improved over time. However, no adjunctive lesion set, in addition to pulmonary vein isolation, has been conclusively demonstrated to be beneficial. Through the use of trial sequential analysis, we highlight the importance of adequately powered randomized controlled trials, to avoid reaching premature conclusions, before widespread adoption of novel therapies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Bases de Dados Factuais , Fluoroscopia
4.
Ann Intern Med ; 175(12): 1658-1665, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36343346

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) improve survival in patients at risk for cardiac arrest, but are associated with intravascular lead-related complications. The subcutaneous ICD (S-ICD), with no intravascular components, was developed to minimize lead-related complications. OBJECTIVE: To assess key ICD performance measures related to delivery of ICD therapy, including inappropriate ICD shocks (delivered in absence of life-threatening arrhythmia) and failed ICD shocks (which did not terminate ventricular arrhythmia). DESIGN: Randomized, multicenter trial. (ClinicalTrials.gov: NCT02881255). SETTING: The ATLAS trial. PATIENTS: 544 eligible patients (141 female) with a primary or secondary prevention indication for an ICD who were younger than age 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications were electrocardiographically screened and 503 randomly assigned to S-ICD (251 patients) or transvenous ICD (TV-ICD) (252 patients). Mean follow-up was 2.5 years (SD, 1.1). Mean age was 49.0 years (SD, 11.5). MEASUREMENTS: The primary outcome was perioperative major lead-related complications. RESULTS: There was a statistically significant reduction in perioperative, lead-related complications, which occurred in 1 patient (0.4%) with an S-ICD and in 12 patients (4.8%) with TV-ICD (-4.4%; 95% CI, -6.9 to -1.9; P = 0.001). There was a trend for more inappropriate shocks with the S-ICD (hazard ratio [HR], 2.37; 95% CI, 0.98 to 5.77), but no increase in failed appropriate ICD shocks (HR, 0.61 (0.15 to 2.57). Patients in the S-ICD group had more ICD site pain, measured on a 10-point numeric rating scale, on the day of implant (4.2 ± 2.8 vs. 2.9 ± 2.2; P < 0.001) and 1 month later (1.3 ± 1.8 vs. 0.9 ± 1.5; P = 0.035). LIMITATION: At present, the ATLAS trial is underpowered to detect differences in clinical shock outcomes; however, extended follow-up is ongoing. CONCLUSION: The S-ICD reduces perioperative, lead-related complications without significantly compromising the effectiveness of ICD shocks, but with more early postoperative pain and a trend for more inappropriate shocks. PRIMARY FUNDING SOURCE: Boston Scientific.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Feminino , Humanos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Arritmias Cardíacas , Fatores de Risco , Morte Súbita Cardíaca/etiologia
5.
Am Heart J ; 254: 133-140, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36030965

RESUMO

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Qualidade de Vida , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
6.
Br J Pharmacol ; 179(9): 2037-2053, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34855992

RESUMO

BACKGROUND AND PURPOSE: Sudden cardiac death (SCD) caused by acute myocardial ischaemia and ventricular fibrillation (VF) is an unmet therapeutic need. Lidocaine suppresses ischaemia-induced VF, but its utility is limited by side effects and a narrow therapeutic index. Here, we characterise OCT2013, a putative ischaemia-activated prodrug of lidocaine. EXPERIMENTAL APPROACH: The rat Langendorff-perfused isolated heart, anaesthetised rat and rat ventricular myocyte preparations were utilised in a series of blinded and randomised studies to investigate the antiarrhythmic effectiveness, adverse effects and mechanism of action of OCT2013, compared with lidocaine. KEY RESULTS: In isolated hearts, OCT2013 and lidocaine prevented ischaemia-induced VF equi-effectively, but OCT2013 did not share lidocaine's adverse effects (PR widening, bradycardia and negative inotropy). In anaesthetised rats, i.v. OCT2013 and lidocaine suppressed VF and increased survival equi-effectively; OCT2013 had no effect on cardiac output even at 64 mg·kg-1 i.v., whereas lidocaine reduced it even at 1 mg·kg-1 . In adult rat ventricular myocytes, OCT2013 had no effect on Ca2+ handling, whereas lidocaine impaired it. In paced isolated hearts, lidocaine caused rate-dependent conduction slowing and block, whereas OCT2013 was inactive. However, during regional ischaemia, OCT2013 and lidocaine equi-effectively hastened conduction block. Chromatography and MS analysis revealed that OCT2013, detectable in normoxic OCT2013-perfused hearts, became undetectable during global ischaemia, with lidocaine becoming detectable. CONCLUSIONS AND IMPLICATIONS: OCT2013 is inactive but is bio-reduced locally in ischaemic myocardium to lidocaine, acting as an ischaemia-activated and ischaemia-selective antiarrhythmic prodrug with a large therapeutic index, mimicking lidocaine's benefit without adversity.


Assuntos
Isquemia Miocárdica , Pró-Fármacos , Animais , Antiarrítmicos/farmacologia , Isquemia , Lidocaína/farmacologia , Isquemia Miocárdica/complicações , Isquemia Miocárdica/tratamento farmacológico , Pró-Fármacos/farmacologia , Ratos , Ratos Wistar , Fibrilação Ventricular
7.
Heart Rhythm ; 19(4): 516-524, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34915187

RESUMO

BACKGROUND: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system may play a role in atrial fibrillation (AF). OBJECTIVE: We hypothesized that ablating the ectopy-triggering GPs (ET-GPs) prevents AF. METHODS: GANGLIA-AF (ClinicalTrials.gov identifier NCT02487654) was a prospective, randomized, controlled, 3-center trial. ET-GPs were mapped using high frequency stimulation, delivered within the atrial refractory period and ablated until nonfunctional. If triggered AF became incessant, atrioventricular dissociating GPs were ablated. We compared GP ablation (GPA) without pulmonary vein isolation (PVI) against PVI in patients with paroxysmal AF. Follow-up was for 12 months including 3-monthly 48-hour Holter monitors. The primary end point was documented ≥30 seconds of atrial arrhythmia after a 3-month blanking period. RESULTS: A total of 102 randomized patients were analyzed on a per-protocol basis after GPA (n = 52; 51%) or PVI (n = 50; 49%). Patients who underwent GPA had 89 ± 26 high frequency stimulation sites tested, identifying a median of 18.5% (interquartile range 16%-21%) of GPs. The radiofrequency ablation time was 22.9 ± 9.8 minutes in GPA and 38 ± 14.4 minutes in PVI (P < .0001). The freedom from ≥30 seconds of atrial arrhythmia at 12-month follow-up was 50% (26 of 52) with GPA vs 64% (32 of 50) with PVI (log-rank, P = .09). ET-GPA without atrioventricular dissociating GPA achieved 58% (22 of 38) freedom from the primary end point. There was a significantly higher reduction in antiarrhythmic drug usage postablation after GPA than after PVI (55.5% vs 36%; P = .05). Patients were referred for redo ablation procedures in 31% (16 of 52) after GPA and 24% (12 of 50) after PVI (P = .53). CONCLUSION: GPA did not prevent atrial arrhythmias more than PVI. However, less radiofrequency ablation was delivered to achieve a higher reduction in antiarrhythmic drug usage with GPA than with PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Gânglios/cirurgia , Átrios do Coração , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
10.
Europace ; 23(11): 1698-1707, 2021 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-33948648

RESUMO

Evidence has accumulated over the last century of the importance of a critical electrical mass in sustaining atrial fibrillation (AF). AF ablation certainly reduces electrically contiguous atrial mass, but this is not widely accepted to be an important part of its mechanism of action. In this article, we review data showing that atrial size is correlated in many settings with AF propensity. Larger mammals are more likely to exhibit AF. This is seen both in the natural world and in animal models, where it is much easier to create a goat model than a mouse model of AF, for example. This also extends to humans-athletes, taller people, and obese individuals all have large atria and are more likely to exhibit AF. Within an individual, risk factors such as hypertension, valvular disease and ischaemia can enlarge the atrium and increase the risk of AF. With respect to AF ablation, we explore how variations in ablation strategy and the relative effectiveness of these strategies may suggest that a reduction in electrical atrial mass is an important mechanism of action. We counter this with examples in which there is no doubt that mass reduction is less important than competing theories such as ganglionated plexus ablation. We conclude that, when considering future strategies for the ablative therapy of AF, it is important not to discount the possibility that contiguous electrical mass reduction is the most important mechanism despite the disappointing consequence being that enhancing success rates in AF ablation may involve greater tissue destruction.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Mamíferos , Camundongos , Resultado do Tratamento
11.
Eur Heart J ; 42(8): 847-857, 2021 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-33495788

RESUMO

AIMS: The aim of this study was to understand the changing trends in atrial fibrillation (AF) incidence and mortality across Europe from 1990 to 2017, and how socioeconomic factors and sex differences play a role. METHODS AND RESULTS: We performed a temporal analysis of data from the 2017 Global Burden of Disease Database for 20 countries across Europe using Joinpoint regression analysis. Age-adjusted incidence, mortality, and mortality-to-incidence ratios (MIRs) to approximate case fatality rate are presented. Incidence and mortality trends were heterogenous throughout Europe, with Austria, Denmark, and Sweden experiencing peaks in incidence in the middle of the study period. Mortality rates were higher in wealthier countries with the highest being Sweden for both men and women (8.83 and 8.88 per 100 000, respectively) in 2017. MIRs were higher in women in all countries studied, with the disparity increasing the most over time in Germany (43.6% higher in women vs. men in 1990 to 74.5% higher in women in 2017). CONCLUSION: AF incidence and mortality across Europe did not show a general trend, but unique patterns for some nations were observed. Higher mortality rates were observed in wealthier countries, potentially secondary to a survivor effect where patients survive long enough to suffer from AF and its complications. Outcomes for women with AF were worse than men, represented by higher MIRs. This suggests that there is widespread healthcare inequality between the sexes across Europe, or that there are biological differences between them in terms of their risk of adverse outcomes from AF.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/epidemiologia , Áustria , Europa (Continente)/epidemiologia , Feminino , Alemanha , Humanos , Incidência , Masculino , Fatores de Risco , Fatores Socioeconômicos , Suécia
12.
J Cardiovasc Electrophysiol ; 32(2): 235-244, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33421265

RESUMO

BACKGROUND: Ganglionated plexuses (GPs) are implicated in atrial fibrillation (AF). Endocardial high-frequency stimulation (HFS) delivered within the local atrial refractory period can trigger ectopy and AF from specific GP sites (ET-GP). The aim of this study was to understand the role of ET-GP ablation in the treatment of AF. METHODS: Patients with paroxysmal AF indicated for ablation were recruited. HFS mapping was performed globally around the left atrium to identify ET-GP. ET-GP was defined as atrial ectopy or atrial arrhythmia triggered by HFS. All ET-GP were ablated, and PVs were left electrically connected. Outcomes were compared with a control group receiving pulmonary vein isolation (PVI). Patients were followed-up for 12 months with multiple 48-h Holter ECGs. Primary endpoint was ≥30 s AF/atrial tachycardia in ECGs. RESULTS: In total, 67 patients were recruited and randomized to ET-GP ablation (n = 39) or PVI (n = 28). In the ET-GP ablation group, 103 ± 28 HFS sites were tested per patient, identifying 21 ± 10 (20%) GPs. ET-GP ablation used 23.3 ± 4.1 kWs total radiofrequency (RF) energy per patient, compared with 55.7 ± 22.7 kWs in PVI (p = <.0001). Duration of procedure was 3.7 ± 1.0 and 3.3 ± 0.7 h in ET-GP ablation group and PVI, respectively (p = .07). Follow-up at 12 months showed that 61% and 49% were free from ≥30 s of AF/AT with PVI and ET-GP ablation respectively (log-rank p = .27). CONCLUSIONS: It is feasible to perform detailed global functional mapping with HFS and ablate ET-GP to prevent AF. This provides direct evidence that ET-GPs are part of the AF mechanism. The lower RF requirement implies that ET-GP targets the AF pathway more specifically.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrocardiografia Ambulatorial , Átrios do Coração , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
Auton Neurosci ; 228: 102699, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32769021

RESUMO

BACKGROUND: Epicardial ganglionated plexuses (GP) have an important role in the pathogenesis of atrial fibrillation (AF). The relationship between anatomical, histological and functional effects of GP is not well known. We previously described atrioventricular (AV) dissociating GP (AVD-GP) locations. In this study, we hypothesised that ectopy triggering GP (ET-GP) are upstream triggers of atrial ectopy/AF and have different anatomical distribution to AVD-GP. OBJECTIVES: We mapped and characterised ET-GP to understand their neural mechanism in AF and anatomical distribution in the left atrium (LA). METHODS: 26 patients with paroxysmal AF were recruited. All were paced in the LA with an ablation catheter. High frequency stimulation (HFS) was synchronised to each paced stimulus for delivery within the local atrial refractory period. HFS responses were tagged onto CARTO™ 3D LA geometry. All geometries were transformed onto one reference LA shell. A probability distribution atlas of ET-GP was created. This identified high/low ET-GP probability regions. RESULTS: 2302 sites were tested with HFS, identifying 579 (25%) ET-GP. 464 ET-GP were characterised, where 74 (16%) triggered ≥30s AF/AT. Median 97 (IQR 55) sites were tested, identifying 19 (20%) ET-GP per patient. >30% of ET-GP were in the roof, mid-anterior wall, around all PV ostia except in the right inferior PV (RIPV) in the posterior wall. CONCLUSION: ET-GP can be identified by endocardial stimulation and their anatomical distribution, in contrast to AVD-GP, would be more likely to be affected by wide antral circumferential ablation. This may contribute to AF ablation outcomes.


Assuntos
Fibrilação Atrial/fisiopatologia , Complexos Atriais Prematuros/fisiopatologia , Ablação por Cateter , Gânglios Autônomos/fisiologia , Coração/inervação , Pericárdio/inervação , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Complexos Atriais Prematuros/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
JACC Clin Electrophysiol ; 6(6): 609-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32553209

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy, health care utilization, and safety of a same-day discharge protocol. BACKGROUND: Catheter ablation of atrial fibrillation (AF) is the most common ablation performed. Increasing volumes of AF ablation are placing demands on hospital resources. In response, our institutions developed a same-day discharge protocol for AF ablation. METHODS: This was a multicenter cohort study of all patients undergoing AF ablation from 2010 to 2014 at 2 major centers. The primary efficacy outcome was the proportion of successful same-day discharges. The primary health care utilization outcome was 30-day hospital readmission for any reason. The primary safety outcome was a composite of 30-day death, stroke/transient ischemic attack or embolism, or bleeding requiring hospitalization. RESULTS: A total of 3,054 patients underwent AF ablation from 2010 to 2014 and met inclusion criteria. Same-day discharge was achieved in 79.2% (2,418 of 3,054). Hospital readmission at 30 days was 7.7% for the same-day discharge group, 10.2% for those who remained in the hospital overnight without complications (p = 0.055 for comparison with same-day discharge), and 19.5% (p < 0.001) for those who remained in the hospital with procedural complications (7.7%). Complication rates from discharge to 30 days (excluding immediate procedural complications) were 0.37% for the same-day discharge group, 0.36% (p = 0.999) for those kept overnight without complications, and 2.5% (p = 0.044) for those with initial procedural complications. CONCLUSIONS: Same-day discharge after AF ablation is feasible in the majority of patients with use of a standardized protocol. This approach was not associated with higher hospital readmission or complication rates after discharge.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Humanos , Alta do Paciente , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento
16.
JACC Clin Electrophysiol ; 5(8): 968-976, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31439299

RESUMO

OBJECTIVES: This meta-analysis examined the ability of pulmonary vein isolation (PVI) to prevent atrial fibrillation in randomized controlled trials (RCTs) in which the patients not receiving PVI nevertheless underwent a procedure. BACKGROUND: PVI is a commonly used procedure for the treatment of atrial fibrillation (AF), and its efficacy has usually been judged against therapy with anti-arrhythmic drugs in open-label trials. There have been several RCTs of AF ablation in which both arms received an ablation, but the difference between the treatment arms was inclusion or omission of PVI. These trials of an ablation strategy with PVI versus an ablation strategy without PVI may provide a more rigorous method for evaluating the efficacy of PVI. METHODS: Medline and Cochrane databases were searched for RCTs comparing ablation including PVI with ablation excluding PVI. The primary efficacy endpoint was freedom from atrial fibrillation (AF) and atrial tachycardia at 12 months. A random-effects meta-analysis was performed using the restricted maximum likelihood estimator. RESULTS: Overall, 6 studies (n = 610) met inclusion criteria. AF recurrence was significantly lower with an ablation including PVI than an ablation without PVI (RR: 0.54; 95% confidence interval [CI]: 0.33 to 0.89; p = 0.0147; I2 = 79.7%). Neither the type of AF (p = 0.48) nor the type of non-PVI ablation (p = 0.21) was a significant moderator of the effect size. In 3 trials the non-PVI ablation procedure was performed in both arms, whereas PVI was performed in only 1 arm. In these studies, AF recurrence was significantly lower when PVI was included (RR: 0.32; 95% CI: 0.14 to 0.73; p = 0.007, I2 78%). CONCLUSIONS: In RCTs where both arms received an ablation, and therefore an expectation amongst patients and doctors of benefit, being randomized to PVI had a striking effect, reducing AF recurrence by a half.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva
18.
Europace ; 21(8): 1176-1184, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31071213

RESUMO

AIMS: Ablation of persistent atrial fibrillation (PsAF) has been performed by many techniques with varying success rates. This may be due to ablation techniques, patient demographics, comorbidities, and trial design. We conducted a meta-regression of studies of PsAF ablation to elucidate the factors affecting atrial fibrillation (AF) recurrence. METHODS AND RESULTS: Databases were searched for prospective studies of PsAF ablation. A meta-regression was performed. Fifty-eight studies (6767 patients) were included. Complex fractionated atrial electrogram (CFAE) ablation reduced freedom from AF by 8.9% [95% confidence interval (CI) -15 to -2.3, P = 0.009). Left atrial appendage [LAA isolation (three study arms)] increased freedom from AF by 39.5% (95% CI 9.1-78.4, P = 0.008). Posterior wall isolation (PWI) (eight study arms) increased freedom from AF by 19.4% (95% CI 3.3-38.1, P = 0.017). Linear ablation or ganglionated plexi ablation resulted in no significant effect on freedom from AF. More extensive ablation increased intraprocedural AF termination; however, intraprocedural AF termination was not associated with improved outcomes. Increased left atrial diameter was associated with a reduction in freedom from AF by 4% (95% CI -6.8% to -1.1%, P = 0.007) for every 1 mm increase in diameter. CONCLUSION: Linear ablation, PWI, and CFAE ablation improves intraprocedural AF termination, but such termination does not predict better long-term outcomes. Study arms including PWI or LAA isolation in the lesion set were associated with improved outcomes in terms of freedom from AF; however, further randomized trials are required before these can be routinely recommended. Left atrial size is the most important marker of AF chronicity influencing outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Efeitos Adversos de Longa Duração/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Recidiva , Análise de Regressão , Medição de Risco/métodos , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 29(12): 1624-1634, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30168232

RESUMO

INTRODUCTION: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system are implicated in arrhythmogenesis. GP localization by stimulation of the epicardial fat pads to produce atrioventricular dissociating (AVD) effects is well described. We determined the anatomical distribution of the left atrial GPs that influence atrioventricular (AV) dissociation. METHODS AND RESULTS: High frequency stimulation was delivered through a Smart-Touch catheter in the left atrium of patients undergoing atrial fibrillation (AF) ablation. Three dimensional locations of points tested throughout the entire chamber were recorded on the CARTO™ system. Impact on the AV conduction was categorized as ventricular asystole, bradycardia, or no effect. CARTO maps were exported, registered, and transformed onto a reference left atrial geometry using a custom software, enabling data from multiple patients to be overlaid. In 28 patients, 2108 locations were tested and 283 sites (13%) demonstrated (AVD-GP) effects. There were 10 AVD-GPs (interquartile range, 11.5) per patient. Eighty percent (226) produced asystole and 20% (57) showed bradycardia. The distribution of the two groups was very similar. Highest probability of AVD-GPs (>20%) was identified in: inferoseptal portion (41%) and right inferior pulmonary vein base (30%) of the posterior wall, right superior pulmonary vein antrum (31%). CONCLUSION: It is feasible to map the entire left atrium for AVD-GPs before AF ablation. Aggregated data from multiple patients, producing a distribution probability atlas of AVD-GPs, identified three regions with a higher likelihood for finding AVD-GPs and these matched the histological descriptions. This approach could be used to better characterize the autonomic network.


Assuntos
Atlas como Assunto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Gânglios Autônomos/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Idoso , Ablação por Cateter/métodos , Feminino , Gânglios Autônomos/anatomia & histologia , Átrios do Coração/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Probabilidade
20.
J Cardiovasc Electrophysiol ; 29(11): 1471-1479, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30230101

RESUMO

OBJECTIVE: We tested whether ablation methodology and study design can explain the varying outcomes in terms of atrial fibrillation (AF)-free survival at 1 year. BACKGROUND: There have been numerous paroxysmal AF ablation trials, which are heterogeneous in their use of different ablation techniques and study design. A useful approach to understanding how these factors influence outcome is to dismantle the trials into individual arms and reconstitute them as a large meta-regression. METHODS: Data were collected from 66 studies (6941 patients). With freedom from AF as the dependent variable, we performed meta-regression using the individual study arm as the unit. RESULTS: Success rates did not change regardless of the technique used to produce pulmonary vein isolation (PVI). Neither was adjunctive lesion sets associated with any improvement in outcome. Studies that included more males and fewer hypertensive patients were found more likely to report better outcomes. The electrocardiography method selected to assess outcome also plays an important role. Outcomes were worse in studies that used regular telemonitoring (by 23%; P < 0.001) or in patients who had implantable loop recorders (by 21%; P = 0.006), rather than those with the less thorough periodic Holter monitoring. CONCLUSIONS: Outcomes of AF ablation studies involving PVI are not affected by the technologies used to produce PVI. Neither do adjunctive lesion sets change the outcome. Achieving high success rates in these studies appears to be dependent more on patient mix and on the thoroughness of AF detection protocols. These should be carefully considered when quoting the success rates of AF ablation procedures that are derived from such studies.


Assuntos
Técnicas de Ablação/métodos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Técnicas de Ablação/tendências , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/tendências , Humanos , Seleção de Pacientes , Taxa de Sobrevida/tendências , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA