1.
J Biomed Mater Res B Appl Biomater ; 111(12): 2064-2076, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37596906

RESUMO

Polypropylene (PP) surgical mesh had reasonable success in repair of hernia and treatment of stress urinary incontinence (SUI); however, their use for the repair of pelvic organ prolapse (POP) resulted in highly variable results with lifelong complications in some patients. One of several factors that could be associated with mesh-related POP complications is changes in the properties of the implanted surgical mesh due to oxidative degradation of PP in vivo. Currently, there are no standardized in vitro bench testing methods available for assessing the susceptibility to oxidative degradation and estimating long-term in vivo stability of surgical mesh. In this work, we adapted a previously reported automated reactive accelerated aging (aRAA) system, which uses elevated temperatures and high concentrations of hydrogen peroxide (H2 O2 ), for accelerated bench-top oxidative degradation testing of PP surgical mesh. Since H2 O2 is highly unstable at elevated temperatures and for prolonged periods, the aRAA system involves a feedback loop based on electrochemical detection methods to maintain consistent H2 O2 concentration in test solutions. Four PP mesh samples with varying mesh knit designs, filament diameter, weight, and % porosity, were selected for testing using aRAA up to 4 weeks and characterized using thermal analysis, Fourier-transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) and scanning electron microscopy (SEM). Additionally, the oxidation index (OI) values were calculated based on the FTIR-ATR spectra to estimate the oxidative degradation and oxidation reaction kinetics of PP surgical mesh. The OI values and surface damage in the form of surface flaking, peeling, and formation of transverse cracks increased with aRAA aging time. The aRAA test method introduced here could be used to standardize the assessment of long-term stability of surgical mesh and may also be adopted for accelerated oxidative degradation testing of other polymer-based medical devices.

2.
Biomech Model Mechanobiol ; 21(4): 1117-1131, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35534762

RESUMO

Recent reports of adverse health effects (e.g., capsular contracture, lymphoma) linked to the absence or presence of texture on soft-tissue implants (e.g., breast implants) suggest surface topography may have pathological impact(s). We propose that surface texture influences the transfer of displacements, experienced by an implant undergoing micromotion, to surrounding interfacial extracellular matrix, which in turn impacts the activity of the resident cells and is based on degree of tissue integration. We hypothesize that transfer of displacements due to micromotion promotes interstitial fluid movement that imposes hydrodynamic stresses (pressures, shear stresses) on cells residing in the interfacial tissues and impacts their activity. To address this, we developed a computer simulation to approximate hydrodynamic stresses in the interstitial environment of saturated poroelastic tissues (model soft-tissue implantation sites) generated from oscillatory implant micromotion as a function of the magnitude of translational displacement, direction of motion, degree of tissue integration, and surface roughness of the implant. Highly integrated implants were predicted to generate the highest fluid shear stresses within model tissues, with oscillatory fluid shear stresses up to 80 dyn/cm2 for a 20-µm displacement. Notably, application of oscillatory 80 dyn/cm2 shear stress to cultured human fibroblasts elicited cell death after 20 h compared to cells maintained under static conditions or exposed to 80 dyn/cm2 steady, unidirectional shear. These results indicate that oscillatory interstitial fluid stresses generated by micromotion of an integrated implant may influence the activity of the surrounding cells and play a role in the body's fibrotic response to textured soft-tissue implants.


Assuntos
Hidrodinâmica , Próteses e Implantes , Simulação por Computador , Humanos , Movimento (Física) , Estresse Mecânico
3.
Shap Mem Superelasticity ; 8: 98-106, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37720627

RESUMO

Nitinol is a nickel-titanium alloy widely used in medical devices for its unique pseudoelastic and shape-memory properties. However, nitinol can release potentially hazardous amounts of nickel, depending on surface manufacturing yielding different oxide thicknesses and compositions. Furthermore, nitinol medical devices can be implanted throughout the body and exposed to extremes in pH and reactive oxygen species (ROS), but few tools exist for evaluating nickel release under such physiological conditions. Even in cardiovascular applications, where nitinol medical devices are relatively common and the blood environment is well understood, there is a lack of information on how local inflammatory conditions after implantation might affect nickel ion release. For this study, nickel release from nitinol wires of different finishes was measured in pH conditions and at ROS concentrations selected to encompass and exceed literature reports of extracellular pH and ROS. Results showed increased nickel release at levels of pH and ROS reported to be physiological, with decreasing pH and increasing concentrations of hydrogen peroxide and NaOCl/HOCl having the greatest effects. The results support the importance of considering the implantation site when designing studies to predict nickel release from nitinol and underscore the value of understanding the chemical milieu at the device-tissue interface.

4.
Toxicol Sci ; 172(1): 201-212, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31388681

RESUMO

Many polymeric medical devices contain color additives for differentiation or labeling. Although some additives can be toxic under certain conditions, the risk associated with the use of these additives in medical device applications is not well established, and evaluating their impact on device biocompatibility can be expensive and time consuming. Therefore, we have developed a framework to conduct screening-level risk assessments to aid in determining whether generating color additive exposure data and further risk evaluation are necessary. We first derive tolerable intake values that are protective for worst-case exposure to 8 commonly used color additives. Next, we establish a model to predict exposure limited only by the diffusive transport of the additive through the polymer matrix. The model is parameterized using a constitutive model for diffusion coefficient (D) as a function of molecular weight (Mw) of the color additive. After segmenting polymer matrices into 4 distinct categories, upper bounds on D(Mw) were determined based on available data for each category. The upper bounds and exposure predictions were validated independently to provide conservative estimates. Because both components (toxicity and exposure) are conservative, a ratio of tolerable intake to exposure in excess of one indicates acceptable risk. Application of this approach to typical colored polymeric materials used in medical devices suggests that additional color additive risk evaluation could be eliminated in a large percentage (≈90%) of scenarios.

5.
Acta Biomater ; 70: 304-314, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29408403

RESUMO

Many cardiovascular device alloys contain nickel, which if released in sufficient quantities, can lead to adverse health effects. However, in-vivo nickel release from implanted devices and subsequent biodistribution of nickel ions to local tissues and systemic circulation are not well understood. To address this uncertainty, we have developed a multi-scale (material, tissue, and system) biokinetic model. The model links nickel release from an implanted cardiovascular device to concentrations in peri-implant tissue, as well as in serum and urine, which can be readily monitored. The model was parameterized for a specific cardiovascular implant, nitinol septal occluders, using in-vitro nickel release test results, studies of ex-vivo uptake into heart tissue, and in-vivo and clinical measurements from the literature. Our results show that the model accurately predicts nickel concentrations in peri-implant tissue in an animal model and in serum and urine of septal occluder patients. The congruity of the model with these data suggests it may provide useful insight to establish nickel exposure limits and interpret biomonitoring data. Finally, we use the model to predict local and systemic nickel exposure due to passive release from nitinol devices produced using a wide range of manufacturing processes, as well as general relationships between release rate and exposure. These relationships suggest that peri-implant tissue and serum levels of nickel will remain below 5 µg/g and 10 µg/l, respectively, in patients who have received implanted nitinol cardiovascular devices provided the rate of nickel release per device surface area does not exceed 0.074 µg/(cm2 d) and is less than 32 µg/d in total. STATEMENT OF SIGNIFICANCE: The uncertainty in whether in-vitro tests used to evaluate metal ion release from medical products are representative of clinical environments is one of the largest roadblocks to establishing the associated patient risk. We have developed and validated a multi-scale biokinetic model linking nickel release from cardiovascular devices in-vivo to both peri-implant and systemic levels. By providing clinically relevant exposure estimates, the model vastly improves the evaluation of risk posed to patients by the nickel contained within these devices. Our model is the first to address the potential for local and systemic metal ion exposure due to a medical device and can serve as a basis for future efforts aimed at other metal ions and biomedical products.


Assuntos
Ligas , Modelos Biológicos , Miocárdio , Níquel , Dispositivo para Oclusão Septal/efeitos adversos , Ligas/efeitos adversos , Ligas/farmacocinética , Animais , Miocárdio/metabolismo , Miocárdio/patologia , Níquel/efeitos adversos , Níquel/farmacocinética , Suínos
6.
J Biomed Mater Res B Appl Biomater ; 106(2): 854-862, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28419752

RESUMO

INTRODUCTION: Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. METHODS: The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. RESULTS: Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. CONCLUSIONS: Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018.


Assuntos
Teste de Materiais , Telas Cirúrgicas , Resistência à Tração , Propriedades de Superfície
7.
J Neurosurg Spine ; 26(4): 524-531, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28128700

RESUMO

OBJECTIVE Lumbar cages with integrated fixation screws offer a low-profile alternative to a standard cage with anterior supplemental fixation. However, the mechanical stability of integrated fixation cages (IFCs) compared with a cage with anterior plate fixation under fatigue loading has not been investigated. The purpose of this study was to compare the biomechanical stability of a screw-based IFC with a standard cage coupled with that of an anterior plate under fatigue loading. METHODS Eighteen functional spinal units were implanted with either a 4-screw IFC or an anterior plate and cage (AP+C) without integrated fixation. Flexibility testing was conducted in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) on intact spines, immediately after device implantation, and post-fatigue up to 20,000 cycles of FE loading. Stability parameters such as range of motion (ROM) and lax zone (LZ) for each loading mode were compared between the 2 constructs at multiple stages of testing. In addition, construct loosening was quantified by subtracting post-instrumentation ROM from post-fatigue ROM. RESULTS IFC and AP+C configurations exhibited similar stability (ROM and LZ) at every stage of testing in FE (p ≥ 0.33) and LB (p ≥ 0.23) motions. In AR, however, IFCs had decreased ROM compared with AP+C constructs at pre-fatigue (p = 0.07) and at all post-fatigue time points (p ≤ 0.05). LZ followed a trend similar to that of ROM in AR. ROM increased toward intact motion during fatigue cycling for AP+C and IFC implants. IFC specimens remained significantly (p < 0.01) more rigid than specimens in the intact condition during fatigue for each loading mode, whereas AP+C construct motion did not differ significantly (p ≥ 0.37) in FE and LB and was significantly greater (p < 0.01) in AR motion compared with intact specimens after fatigue. Weak to moderate correlations (R2 ≤ 56%) were observed between T-scores and construct loosening, with lower T-scores leading to decreased stability after fatigue testing. CONCLUSIONS These data indicate that a 4-screw IFC design provides fixation similar to that provided by an AP+C construct in FE and LB during fatigue testing and better stability in AR motion.


Assuntos
Fixadores Internos , Vértebras Lombares/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Vértebras Lombares/fisiopatologia , Masculino , Maleabilidade , Falha de Prótese , Amplitude de Movimento Articular
8.
Proc Natl Acad Sci U S A ; 111(48): 17308-13, 2014 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-25404299

RESUMO

Atherosclerotic plaque localization correlates with regions of disturbed flow in which endothelial cells (ECs) align poorly, whereas sustained laminar flow correlates with cell alignment in the direction of flow and resistance to atherosclerosis. We now report that in hypercholesterolemic mice, deletion of syndecan 4 (S4(-/-)) drastically increased atherosclerotic plaque burden with the appearance of plaque in normally resistant locations. Strikingly, ECs from the thoracic aortas of S4(-/-) mice were poorly aligned in the direction of the flow. Depletion of S4 in human umbilical vein endothelial cells (HUVECs) using shRNA also inhibited flow-induced alignment in vitro, which was rescued by re-expression of S4. This effect was highly specific, as flow activation of VEGF receptor 2 and NF-κB was normal. S4-depleted ECs aligned in cyclic stretch and even elongated under flow, although nondirectionally. EC alignment was previously found to have a causal role in modulating activation of inflammatory versus antiinflammatory pathways by flow. Consistent with these results, S4-depleted HUVECs in long-term laminar flow showed increased activation of proinflammatory NF-κB and decreased induction of antiinflammatory kruppel-like factor (KLF) 2 and KLF4. Thus, S4 plays a critical role in sensing flow direction to promote cell alignment and inhibit atherosclerosis.


Assuntos
Aterosclerose/metabolismo , Células Endoteliais/metabolismo , Transdução de Sinais , Sindecana-4/metabolismo , Animais , Aterosclerose/genética , Western Blotting , Células Cultivadas , Células Endoteliais/citologia , Feminino , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Fator 4 Semelhante a Kruppel , Fatores de Transcrição Kruppel-Like/genética , Fatores de Transcrição Kruppel-Like/metabolismo , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Confocal , NF-kappa B/metabolismo , Interferência de RNA , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Estresse Mecânico , Sindecana-4/genética , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo