Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Plast Reconstr Surg Glob Open ; 8(1): e2574, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32095393

RESUMO

Biomaterials derived from human adipose extracellular matrix have shown promise in vitro and in animal studies as an off-the-shelf adipogenic matrix for sustained volume replacement. Herein, we report the results of a randomized prospective study conducted with allograft adipose matrix (AAM) grafted into the pannus of presurgical abdominoplasty patients 3 or 6 months before scheduled surgery. This is the first report of a longitudinal histologic analysis of AAM in clinical use. METHODS: Ten healthy patients undergoing elective abdominoplasty were recruited to receive AAM before surgery. Enrolled subjects were randomized into either a 3-month follow-up cohort or a 6-month follow-up cohort. Subjects were monitored for adverse events associated with AAM grafting in addition to undergoing serial biopsy. Following surgical excision of the pannus, representative samples from the AAM surgical sites were stained and evaluated with hematoxylin and eosin for tissue morphology, Masson's trichrome for collagen, and perilipin for adipocytes. RESULTS: All subjects tolerated AAM with no severe adverse events reported. At 3 months following implantation, AAM remained visible within the confines of the subjects' native surrounding adipose tissue with sparse adipocytes apparent within the matrix. By 6 months, AAM had remodeled and was primarily composed of perilipin-positive adipocytes. Histologic analysis confirmed tissue remodeling (hematoxylin and eosin), adipogenesis (perilipin), and angiogenesis (Masson's trichrome) occurred with the presence of AAM. CONCLUSIONS: AAM is a safe, allogeneic, off-the-shelf regenerative matrix that is adipogenic and noninflammatory and promotes angiogenesis.

2.
Adv Wound Care (New Rochelle) ; 9(1): 28-33, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31871828

RESUMO

Objective: The objective of this prospective clinical study was to validate two prototype pressure ulcer monitoring platform (PUMP) devices, (PUMP1 and PUMP2), to promote optimal bed repositioning of hospitalized patients to prevent pressure ulcers (PUs). Approach: PUMP1 was a wearable electronic device attached to the patient gown with no skin contact. PUMP2 was a set of four identical electronic devices placed under the patient's bed wheels. A video camera recorded events in the patient room while measurements from the PUMP devices were correlated with true patient repositioning activity. The performance of these PUMP devices developed by our research team were evaluated and compared by both clinicians and engineers. Results: Ten mobility-restricted patients were enrolled into the study. Repositioning movement was recorded by both PUMP devices for 10 ± 2 h and corroborated with video capture. One hundred thirty-seven movements in total were detected by both PUMP1 and PUMP2 over 105 h of capture. Two false positives were detected by the sensors and 11 movements were missed by the sensors. PUMP1 and PUMP2 never conflicted in data collection. Innovation: The presented study evaluated two different sensors' abilities to capture accurate patient repositioning to eventually prevent PU formation. Importantly, detection of patient motion was completed without contact to patient skin. Conclusion: The clinical study demonstrated successful capture of patient repositioning movement by both PUMP1 and PUMP2 devices with 85% reliability, 2 false positives, and 11 missed movements. In future studies, the PUMP devices will be combined with a SMS-based mobile phone alert system to improve caregiver repositioning behavior.


Assuntos
Monitorização Fisiológica/instrumentação , Movimentação e Reposicionamento de Pacientes/métodos , Posicionamento do Paciente/instrumentação , Úlcera por Pressão/prevenção & controle , Adulto , Idoso , Ensaios Clínicos como Assunto , Desenho de Equipamento/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Dispositivos Eletrônicos Vestíveis/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA