J Occup Environ Med ; 65(7): 610-614, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37043393

RESUMO

OBJECTIVE: The aim of the study is to evaluate the metabolic demands and internal breathing environments when covering an N95 with a surgical mask, cloth mask, and/or FS. METHODS: Three N95 models approved by the National Institute for Occupational Safety and Health were evaluated under six covering conditions using the National Institute for Occupational Safety and Health Automated Breathing and Metabolic Simulator. All conditions used one trial with each N95 for six incremental 5-minute work rates. Inhaled oxygen and carbon dioxide concentrations, peak inhaled and exhaled pressures, and inhaled wet-bulb and dry-bulb temperatures were measured continuously and averaged across all work rates and covering conditions. CONCLUSIONS: Results suggest that metabolic demands and internal breathing environments are significantly impacted by all combinations of coverings tested when compared to N95 only.


Assuntos
Exposição Ocupacional , Saúde Ocupacional , Dispositivos de Proteção Respiratória , Humanos , Respiradores N95 , Máscaras , Exposição Ocupacional/prevenção & controle
2.
J Occup Environ Hyg ; 18(1): 28-34, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33284081

RESUMO

Powered air-purifying respirators (PAPRs) are worn to protect workers from hazardous respiratory exposures in a wide range of workplaces, including healthcare. However, PAPRs may diminish the ability of wearers to correctly hear words spoken by others, potentially interfering with safe performance of healthcare duties. Accordingly, the impact of PAPRs during healthcare use on speech intelligibility (SI) and consequently on user safety, usability, and patient care is not well studied. The objectives of this study were to (1) determine a listener's ability to comprehend single-syllable words spoken by a PAPR wearer; (2) determine a PAPR wearer's ability to intelligibly hear and identify single-syllable words spoken by a PAPR wearer; (3) to assess the variability between speakers, listeners, and PAPR models; (4) to investigate the effects of PAPR design features on SI; and (5) inform a SI requirement for certifying future PAPRs for use in healthcare. This study utilized a Modified Rhyme Test to assess SI for PAPRs. The current National Institute for Occupational Safety and Health (NIOSH) methods for assessing SI are limited to the recently introduced PAPR100 respirator class and the class of respirators claiming chemical, biological, radiological, and nuclear (CBRN) protections. Four NIOSH-approved PAPRs were evaluated using four human subjects. Four experimental conditions were examined:(1) Speaker and Listener with no PAPR; (2) Speaker and Listener both wearing PAPRs; (3) Speaker with a PAPR, Listener without a PAPR; and (4) Speaker without a PAPR, Listener with a PAPR resulted in a total of 144 experiments. Statistical analysis showed that the SI performance ratings were not significantly different among the PAPR models, but experimental conditions had significant impact on SI. The pattern of SI across the conditions of the experiment also showed a significant difference depending on PAPR model. The SI performance rating for all PAPRs could meet the current NIOSH CBRN certification requirement for speech intelligibility.


Assuntos
Dispositivos de Proteção Respiratória/normas , Inteligibilidade da Fala , Desenho de Equipamento , Pessoal de Saúde , Humanos