Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Med Eng Technol ; 45(2): 136-144, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33632055

RESUMO

There has been a marked rise in the number of avoidable deaths in health services around the world. At the same time there has been a growing increase in antibiotic resistant so-called "superbugs." We examine here the potential role of body temperature measurement in these adverse trends. Electronic based thermometers have replaced traditional mercury (and other liquid-in-glass type) thermometers for reasons of safety rather than superiority. Electronic thermometers are in general less robust from a measurement perspective than their predecessors. We illustrate the implications of unreliable temperature measurement on the diagnosis and management of disease, including COVID-19, through statistical calculations. Since a return to mercury thermometers is both undesirable and impractical, we call for better governance in the current practice of clinical thermometry to ensure the traceability and long-term accuracy of electronic thermometers and discuss how this could be achieved.


Assuntos
Temperatura Corporal/fisiologia , Termometria/métodos , COVID-19/diagnóstico , COVID-19/fisiopatologia , Humanos , Guias de Prática Clínica como Assunto , SARS-CoV-2 , Termômetros/efeitos adversos , Termômetros/normas , Termometria/efeitos adversos , Termometria/instrumentação , Termometria/normas , Incerteza
4.
Physiol Meas ; 40(8): 084004, 2019 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-31362275

RESUMO

OBJECTIVE: People with diabetic neuropathy who have previously ulcerated are at high risk of re-ulceration. They should regularly attend podiatry clinics for surveillance and routine protective podiatric treatment. It has been suggested that inflammation prior to skin breakdown shows up as a hotspot on a thermal image even in the absence of clinical signs. The aim of this study is to quantify inter-patient and intra-patient thermal variations presented by diabetic feet at high risk of ulceration. APPROACH: Whole foot and spot temperatures were recorded for 96 patients who attended two successive podiatry appointments without ulceration 28 [28, 31] days apart, median [interquartile range]. This was a part of a longer study into whether thermal imaging in clinic can reduce the rate of re-ulceration. MAIN RESULTS: The variation in spot temperature right/left differences for single patients between visits was comparable to the variation observed between patients (0.8 [0.3, 1.5] °C compared with 0.9 [0.4, 1.7] °C). Similarly, whole foot temperature variation for a single patient between visits was comparable to the variation observed between patients (0.6 [0.2, 1.1] °C compared with 0.8 [0.2, 1.3] °C). SIGNIFICANCE: Thresholds which depend on thermal differences from visit to visit are unlikely to have sufficient specificity to effectively target treatment designed to prevent the development of foot ulcers.


Assuntos
Assistência Ambulatorial , Pé Diabético/complicações , Neuropatias Diabéticas/complicações , Neuropatias Diabéticas/diagnóstico por imagem , Pé/diagnóstico por imagem , Termografia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Podiatria
5.
PLoS One ; 13(9): e0203302, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30231046

RESUMO

Infrared (IR) modalities represent the only currently viable mass fever screening approaches for outbreaks of infectious disease pandemics such as Ebola virus disease and severe acute respiratory syndrome. Non-contact IR thermometers (NCITs) and IR thermographs (IRTs) have been used for fever screening in public areas such as airports. While NCITs remain a more popular choice than IRTs, there has been increasing evidences in the literature that IRTs can provide great accuracy in estimating body temperature if qualified systems are used and appropriate procedures are consistently applied. In this study, we addressed the issue of IRT qualification by implementing and evaluating a battery of test methods for objective, quantitative assessment of IRT performance based on a recent international standard (IEC 80601-2-59). We tested two commercial IRTs to evaluate their stability and drift, image uniformity, minimum resolvable temperature difference, and radiometric temperature laboratory accuracy. Based on these tests, we illustrated how experimental and data processing procedures could affect results, and suggested methods for clarifying and optimizing test methods. Overall, the insights into thermograph standardization and acquisition methods provided by this study may improve the utility of IR thermography and aid in comparing IRT performance, thus improving the potential for producing high quality disease pandemic countermeasures.


Assuntos
Febre/diagnóstico , Termografia/métodos , Termografia/normas , Aeroportos , Doenças Transmissíveis/diagnóstico , Doenças Transmissíveis/epidemiologia , Surtos de Doenças , Humanos , Raios Infravermelhos , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Programas de Rastreamento/estatística & dados numéricos , Guias de Prática Clínica como Assunto/normas , Termografia/estatística & dados numéricos , Termômetros
6.
Sci Data ; 5: 180124, 2018 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-29944146

RESUMO

Automated time-lapse cameras can facilitate reliable and consistent monitoring of wild animal populations. In this report, data from 73,802 images taken by 15 different Penguin Watch cameras are presented, capturing the dynamics of penguin (Spheniscidae; Pygoscelis spp.) breeding colonies across the Antarctic Peninsula, South Shetland Islands and South Georgia (03/2012 to 01/2014). Citizen science provides a means by which large and otherwise intractable photographic data sets can be processed, and here we describe the methodology associated with the Zooniverse project Penguin Watch, and provide validation of the method. We present anonymised volunteer classifications for the 73,802 images, alongside the associated metadata (including date/time and temperature information). In addition to the benefits for ecological monitoring, such as easy detection of animal attendance patterns, this type of annotated time-lapse imagery can be employed as a training tool for machine learning algorithms to automate data extraction, and we encourage the use of this data set for computer vision development.


Assuntos
Spheniscidae , Imagem com Lapso de Tempo/métodos , Animais , Regiões Antárticas , Monitorização de Parâmetros Ecológicos/métodos , Dinâmica Populacional
7.
J Med Eng Technol ; 42(2): 65-71, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29493342

RESUMO

Non-contact infra-red skin thermometers (NCITs) are becoming more prevalent for use in medical diagnostics. Not only are they used as an alternative means of estimating core body temperature but also to assess the diabetic foot for signs of inflammation prior to ulceration. Previous investigations have compared the performance of NCITs in a clinical setting against other gold standard methods. However, there have been no previous investigations comparing the performance of NCITs in assessing temperature measurement capability traceable to the International Temperature Scale of 1990 (ITS-90). A metrological assessment of nine common NCITs was carried out over the temperature range of 15-45 °C using the National Physical Laboratory's blackbody reference sources to identify their accuracy, repeatability, size-of-source and distance effects. The results are concerning in that five of the NCITs fell far outside the accuracy range stated by their manufacturers as well as the medical standard to which the NCITs are supposed to adhere. Furthermore, a 6 °C step change in measurement error over the temperature range of interest for the diabetic foot was found for one NCIT. These results have implications for all clinicians using NCITs for temperature measurement and demonstrate the need for traceable calibration to ITS-90.


Assuntos
Pele , Termômetros , Calibragem , Raios Infravermelhos , Temperatura
8.
Physiol Meas ; 38(1): 33-44, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27941234

RESUMO

Early identification of areas of inflammation may aid prevention of diabetic foot ulcers. A new bespoke thermal camera system has been developed to thermally image feet at risk. Hotspots (areas at least 2.2 °C hotter than the contralateral site) may indicate areas of inflammation prior to any apparent visual signs. This article describes the thermal pattern and symmetry of 103 healthy pairs of feet. 68% of participants were thermally symmetric at the 33 foot sites measured. 32% of participants had at least one hotspot, but hotspots overall only accounted for 5% of the measurements made. Refinements to the definition of hotspots are proposed when considering feet at risk of ulceration.


Assuntos
Pé Diabético/diagnóstico por imagem , Pé/diagnóstico por imagem , Temperatura , Termografia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Chiropr Osteopat ; 14: 26, 2006 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-17076888

RESUMO

BACKGROUND: The purpose of this systematic review was to critically appraise the literature on the accuracy of orthopaedic tests for the spine. METHODS: Multiple orthopaedic texts were reviewed to produce a comprehensive list of spine orthopaedic test names and synonyms. A search was conducted in MEDLINE, MANTIS, CINAHL, AMED and the Cochrane Library for relevant articles from inception up to December 2005. The studies were evaluated using the tool for quality assessment for diagnostic accuracy studies (QUADAS). RESULTS: Twenty-one papers met the inclusion criteria. The QUADAS scores ranged from 4 to 12 of a possible 14. Twenty-nine percent of the studies achieved a score of 10 or more. The papers covered a wide range of tests for spine conditions. CONCLUSION: There was a lack of quantity and quality of orthopaedic tests for the spine found in the literature. There is a lack of high quality research regarding the accuracy of spinal orthopaedic tests. Due to this lack of evidence it is suggested that over-reliance on single orthopaedic tests is not appropriate.

10.
Physiol Meas ; 25(5): 1239-47, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15535188

RESUMO

The paper describes the comparison method and analyses the results of comparison in terms of agreement between the blackbody of the National Physical Laboratory (NPL), United Kingdom and four different blackbody cavities of the Laboratory of Metrology and Quality (LMK), at the University of Ljubljana, Faculty of Electrical Engineering (FE), Slovenia. Three cavity shapes are suggested in different standards as suitable for calibration of infrared ear thermometers (IRETs), while one cavity shape was proposed by the LMK. The agreement between blackbody cavities was determined with the help of platinum resistance thermometers. Two reference IRETs were used to check their stability and level of agreement between calibration results at different institutes and against different blackbody cavities. Measurements were performed with two IRETs, at the NPL in one cavity and at the LMK in four different cavities. The comparison was initiated to solve the problem of assuring proper traceability for IRETs and to present the solution to their users.


Assuntos
Termômetros/normas , Calibragem , Orelha , Lateralidade Funcional , Humanos , Raios Infravermelhos , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA