Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Arq Bras Cardiol ; 121(7): e20230622, 2024 Jun.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39082574

RESUMO

BACKGROUND: Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. OBJECTIVE: To assess TAVR's LC in Brazil over time. METHODS: We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. RESULTS: A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. CONCLUSION: A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.


Assuntos
Mortalidade Hospitalar , Curva de Aprendizado , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Brasil/epidemiologia , Feminino , Masculino , Idoso de 80 Anos ou mais , Idoso , Fatores de Tempo , Fatores de Risco , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Resultado do Tratamento , Medição de Risco
2.
Arq. bras. cardiol ; 121(7): e20230622, jun.2024. tab, graf
Artigo em Português | LILACS-Express | LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1563934

RESUMO

Resumo Fundamento Dados robustos sobre a curva de aprendizagem (LC) da substituição da válvula aórtica transcateter (TAVR) são escassos nos países em desenvolvimento. Objetivo Avaliar a LC da TAVR no Brasil ao longo do tempo. Métodos Analisamos dados do registro brasileiro de TAVR de 2008 a 2023. Pacientes de cada centro foram numerados cronologicamente em número sequencial de caso (NSC). A LC foi realizada usando um spline cúbico restrito ajustado para o EuroSCORE-II e o uso de próteses de nova geração. Ainda, os desfechos hospitalares foram comparados entre grupos definidos de acordo com o nível de experiência, com base no NSC: 1º ao 40º caso (experiência inicial), 41º ao 80º caso (experiência básica), 81º ao 120º caso (experiência intermediária) e 121º caso em diante (experiência alta). Análises adicionais foram conduzidas de acordo com o número de casos tratados antes de 2014 (>40 e ≤40 procedimentos). O nível de significância adotado foi p <0,05. Resultados Foram incluídos 3194 pacientes de 25 centros. A idade média foi 80,7±8,1 anos e o EuroSCORE II médio foi 7±7,1. A análise da LC demonstrou uma queda na mortalidade hospitalar ajustada após o tratamento de 40 pacientes. Um patamar de nivelamento na curva foi observado após o caso 118. A mortalidade hospitalar entre os grupos foi 8,6%, 7,7%, 5,9%, e 3,7% para experiência inicial, básica, intermediária e alta, respectivamente (p<0,001). A experiência alta foi preditora independente de mortalidade mais baixa (OR 0,57, p=0,013 vs. experiência inicial). Centros com baixo volume de casos antes de 2014 não mostraram uma redução significativa na probabilidade de morte com o ganho de experiência, enquanto centros com alto volume de casos antes de 2014 apresentaram uma melhora contínua após o caso de número 10. Conclusão Observou-se um fenômeno de LC para a mortalidade hospitalar do TAVR no Brasil. Esse efeito foi mais pronunciado em centros que trataram seus 40 primeiros casos antes de 2014 que naqueles que o fizeram após 2014.


Abstract Background Robust data on the learning curve (LC) of transcatheter aortic valve replacement (TAVR) are lacking in developing countries. Objective To assess TAVR's LC in Brazil over time. Methods We analyzed data from the Brazilian TAVR registry from 2008 to 2023. Patients from each center were numbered chronologically in case sequence numbers (CSNs). LC was performed using restricted cubic splines adjusted for EuroSCORE-II and the use of new-generation prostheses. Also, in-hospital outcomes were compared between groups defined according to the level of experience based on the CSN: 1st to 40th (initial-experience), 41st to 80th (early-experience), 81st to 120th (intermediate-experience), and over 121st (high-experience). Additional analysis was performed grouping hospitals according to the number of cases treated before 2014 (>40 and ≤40 procedures). The level of significance adopted was <0.05. Results A total of 3,194 patients from 25 centers were included. Mean age and EuroSCORE II were 80.7±8.1 years and 7±7.1, respectively. LC analysis demonstrated a drop in adjusted in-hospital mortality after treating 40 patients. A leveling off of the curve was observed after case #118. In-hospital mortality across the groups was 8.6%, 7.7%, 5.9%, and 3.7% for initial-, early-, intermediate-, and high-experience, respectively (p<0.001). High experience independently predicted lower mortality (OR 0.57, p=0.013 vs. initial experience). Low-volume centers before 2014 showed no significant decrease in the likelihood of death with gained experience, whereas high-volume centers had a continuous improvement after case #10. Conclusion A TAVR LC phenomenon was observed for in-hospital mortality in Brazil. This effect was more pronounced in centers that treated their first 40 cases before 2014 than those that reached this milestone after 2014.

3.
Arq Bras Cardiol ; 120(9): e20230328, 2023 09.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37878895

RESUMO

Central Illustration : Viability and Safety of Early Hospital Discharge after Minimalist TAVI in the Brazilian Unified Health System Results after transcatheter aortic valve implantation with a minimalist approach. CKD: chronic kidney disease; PO: postoperative days; TAVI: transcatheter aortic valve implantation.


Figura Central : Viabilidade e Segurança de Alta Hospitalar Precoce após TAVI com Abordagem Minimalista no SUS Resultados após implante de prótese aórtica por cateter por abordagem minimalista. DRC: doença renal crônica; PO: dias pós-operativos; TAVI: implante por cateter de prótese aórtica.


Assuntos
Estenose da Valva Aórtica , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Alta do Paciente , Brasil , Resultado do Tratamento , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Fatores de Risco
4.
Arq Bras Cardiol ; 120(7): e20220319, 2023.
Artigo em Inglês, Português | MEDLINE | ID: mdl-37556650

RESUMO

BACKGROUND: The extent of cardiac damage associated with aortic stenosis has important prognostic implications after transcatheter aortic valve replacement (TAVR). However, the role of tricuspid regurgitation (TR) in this clinical setting is still unclear. OBJECTIVES: To explore the association between TR and mortality in patients undergoing TAVR and assess changes in TR severity post TAVR and its relationship with short and mid-term mortality. METHODS: Relevant databases were searched for articles published from inception until August 2020. Out of 414 screened studies, we selected 24 that reported the degree of TR pre or post TAVR. The primary outcome was all-cause mortality, and random effects meta-analysis models were conducted (at a significance level of 5%). RESULTS: Seventeen studies reported associations between pre-TAVR TR and all-cause mortality (> 45,000 participants) and thirteen accessed TR severity post TAVR (709 participants). Moderate/severe baseline TR was associated to higher all-cause mortality both at 30 days (HR 1.65; 95% CI, 1.20-2.29) and 1.2 years (HR 1.56; 95% CI, 1.31-1.84). After TAVR, 43% of patients presented a decrease of at least one grade in TR (30 days, 95% CI, 30-56%), sustained at 12.5 months in 44% of participants (95% CI, 35-52%). Persistence of significant TR was associated with a two-fold increase in all-cause mortality (HR 2.12; 95% CI, 1.53-2.92). CONCLUSIONS: Significant TR pre TAVR is associated with higher mortality. Although TR severity may improve, the persistence of significant TR post TAVR is strongly associated with increased mortality. Our findings highlight the importance of a detailed assessment of TR pre and post TAVR and might help identify patients who may benefit from more careful surveillance in this scenario.


FUNDAMENTO: A extensão do dano cardíaco associada à estenose aórtica tem importantes implicações prognósticas após a substituição da valva aórtica transcateter (TAVR). Contudo, ainda não está claro qual é o papel da insuficiência tricúspide (IT) nesse cenário clínico. OBJETIVOS: Explorar a associação entre IT e mortalidade em pacientes submetidos a TAVR e avaliar as alterações na gravidade da IT após a TAVR e sua relação com mortalidade de curto e médio prazo. MÉTODOS: Foram feitas pesquisas em bases de dados relevantes de artigos publicados do início até agosto de 2020. Dos 414 estudos triados, selecionamos 24 que relataram o grau de IT pré- ou pós-TAVR. O desfecho primário foi mortalidade por todas as causas, e foram conduzidos modelos de metanálise de efeitos aleatórios (a um nível de significância de 5%). RESULTADOS: Dezessete estudos relataram associações entre IT pré-TAVR e mortalidade por todas as causas (> 45.000 participantes), e 13 avaliaram a gravidade da IT pós-TAVR (709 participantes). A IT basal moderada/grave foi associada a maior mortalidade por todas as causas em 30 dias [razão de risco (RR) 1,65; intervalo de confiança (IC) 95% 1,20-2,29] e 1,2 ano (RR 1,56; IC95% 1,31-1,84). Após a TAVR, 43% dos pacientes apresentaram redução de pelo menos um grau na IT (30 dias, IC95% 30-56%), que se sustentou em 12,5 meses em 44% dos participantes (IC95% 35-52%).A persistência de IT significativa foi associada a um aumento de duas vezes na mortalidade por todas as causas (RR 2,12; IC95% 1,53-2,92). CONCLUSÕES: A IT significativa pré-TAVR está associada a maior mortalidade. Ainda que a gravidade da IT possa melhorar, a persistência de IT significativa após a TAVR está fortemente associada ao aumento da mortalidade. Nossos achados destacam a importância de uma avaliação detalhada da IT pré- e pós-TAVR e podem ajudar a identificar pacientes que possam se beneficiar de uma vigilância mais cuidadosa nesse cenário.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Tricúspide/complicações , Resultado do Tratamento , Fatores de Risco , Prognóstico , Valva Aórtica/cirurgia , Índice de Gravidade de Doença
5.
J Invasive Cardiol ; 35(3): E113-E121, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36884359

RESUMO

OBJECTIVE: To enlighten preprocedural risk factors of mitral valve restenosis in a large, single-center cohort of patients submitted to percutaneous mitral balloon commissurotomy (PMBC) for the treatment of mitral stenosis (MS) secondary to rheumatic heart disease. METHODS: This is a database analysis of a single-center, high-volume tertiary institution involving all consecutive PMBC procedures performed in the mitral valve (MV). Restenosis was diagnosed when MV area was <1.5 cm² and/or loss of 50% or more of the immediate procedural result aligned with the return/worsened symptoms of heart failure. The primary endpoint was to determine the preprocedural independent predictors of restenosis after PMBC. RESULTS: Among a total of 1921 PMBC procedures, 1794 consecutive patients without previous intervention were treated between 1987 and 2010. Throughout 24 years of follow-up, MV restenosis was observed in 483 cases (26%). Mean age was 36 years and most (87%) were female. Median follow-up duration was 9.03 years (interquartile range, 0.33-23.38). Restenosis population, however, presented a significantly lower age at the procedure time as well as a higher Wilkins-Block score. At multivariate analysis, independent preprocedure predictors of restenosis were left atrium diameter (hazard risk [HR], 1.03; 95% confidence interval [CI], 1.02-1.05; P<.04), preprocedure maximum gradient (HR, 1.02; 95% CI, 1.00-1.03; P=.04), and higher Wilkins-Block score (>8) (HR, 1.38; 95% CI, 1.14-1.67; P<.01). CONCLUSIONS: At long-term follow-up, MV restenosis was observed in a quarter of the population undergoing PMBC. Preprocedure echocardiographic findings, including left atrial diameter, maximum MV gradient, and Wilkins-Block score were found to be the only independent predictors.


Assuntos
Cateterismo , Estenose da Valva Mitral , Humanos , Feminino , Adulto , Masculino , Cateterismo/efeitos adversos , Seguimentos , Ecocardiografia , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/cirurgia , Estenose da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Constrição Patológica , Recidiva , Resultado do Tratamento
7.
Arq. bras. cardiol ; 120(7): e20220319, 2023. tab, graf
Artigo em Português | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1447323

RESUMO

Resumo Fundamento A extensão do dano cardíaco associada à estenose aórtica tem importantes implicações prognósticas após a substituição da valva aórtica transcateter (TAVR). Contudo, ainda não está claro qual é o papel da insuficiência tricúspide (IT) nesse cenário clínico. Objetivos Explorar a associação entre IT e mortalidade em pacientes submetidos a TAVR e avaliar as alterações na gravidade da IT após a TAVR e sua relação com mortalidade de curto e médio prazo. Métodos Foram feitas pesquisas em bases de dados relevantes de artigos publicados do início até agosto de 2020. Dos 414 estudos triados, selecionamos 24 que relataram o grau de IT pré- ou pós-TAVR. O desfecho primário foi mortalidade por todas as causas, e foram conduzidos modelos de metanálise de efeitos aleatórios (a um nível de significância de 5%). Resultados Dezessete estudos relataram associações entre IT pré-TAVR e mortalidade por todas as causas (> 45.000 participantes), e 13 avaliaram a gravidade da IT pós-TAVR (709 participantes). A IT basal moderada/grave foi associada a maior mortalidade por todas as causas em 30 dias [razão de risco (RR) 1,65; intervalo de confiança (IC) 95% 1,20-2,29] e 1,2 ano (RR 1,56; IC95% 1,31-1,84). Após a TAVR, 43% dos pacientes apresentaram redução de pelo menos um grau na IT (30 dias, IC95% 30-56%), que se sustentou em 12,5 meses em 44% dos participantes (IC95% 35-52%).A persistência de IT significativa foi associada a um aumento de duas vezes na mortalidade por todas as causas (RR 2,12; IC95% 1,53-2,92). Conclusões A IT significativa pré-TAVR está associada a maior mortalidade. Ainda que a gravidade da IT possa melhorar, a persistência de IT significativa após a TAVR está fortemente associada ao aumento da mortalidade. Nossos achados destacam a importância de uma avaliação detalhada da IT pré- e pós-TAVR e podem ajudar a identificar pacientes que possam se beneficiar de uma vigilância mais cuidadosa nesse cenário.


Abstract Background The extent of cardiac damage associated with aortic stenosis has important prognostic implications after transcatheter aortic valve replacement (TAVR). However, the role of tricuspid regurgitation (TR) in this clinical setting is still unclear. Objectives To explore the association between TR and mortality in patients undergoing TAVR and assess changes in TR severity post TAVR and its relationship with short and mid-term mortality. Methods Relevant databases were searched for articles published from inception until August 2020. Out of 414 screened studies, we selected 24 that reported the degree of TR pre or post TAVR. The primary outcome was all-cause mortality, and random effects meta-analysis models were conducted (at a significance level of 5%). Results Seventeen studies reported associations between pre-TAVR TR and all-cause mortality (> 45,000 participants) and thirteen accessed TR severity post TAVR (709 participants). Moderate/severe baseline TR was associated to higher all-cause mortality both at 30 days (HR 1.65; 95% CI, 1.20-2.29) and 1.2 years (HR 1.56; 95% CI, 1.31-1.84). After TAVR, 43% of patients presented a decrease of at least one grade in TR (30 days, 95% CI, 30-56%), sustained at 12.5 months in 44% of participants (95% CI, 35-52%). Persistence of significant TR was associated with a two-fold increase in all-cause mortality (HR 2.12; 95% CI, 1.53-2.92). Conclusions Significant TR pre TAVR is associated with higher mortality. Although TR severity may improve, the persistence of significant TR post TAVR is strongly associated with increased mortality. Our findings highlight the importance of a detailed assessment of TR pre and post TAVR and might help identify patients who may benefit from more careful surveillance in this scenario.

8.
EuroIntervention ; 18(10): 804-811, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-35678222

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. AIMS: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. METHODS: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. RESULTS: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). CONCLUSIONS: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Fatores de Tempo , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Hemodinâmica
9.
Am J Cardiol ; 175: 80-87, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35597627

RESUMO

Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Insuficiência Cardíaca/epidemiologia , Humanos , Estudos Retrospectivos , Medição de Risco/métodos , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
10.
Int. j. cardiovasc. sci. (Impr.) ; 34(5,supl.1): 34-40, Nov. 2021. graf, tab
Artigo em Inglês | LILACS, CONASS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1346335

RESUMO

BACKGROUND: The treatment for symptomatic severe aortic stenosis (AS) is the correction of valve stenosis by surgical valve replacement and more recently by transcatheter aortic valve implant (TAVI). However, in some high risk surgical patients, TAVI is not possible for technical or clinical reasons or due to the unavailability of the endoprosthesis. OBJECTIVE: The aim of this study was to evaluate a mid-term follow-up of symptomatic severe AS patients who are not eligible for TAVI trials, as well as to identify the clinical features of these patients. METHODS: This was an observational, retrospective study conducted with 475 symptomatic severe AS patients, evaluated by the Heart Team between 2000 and 2017. Inclusion criterias were: patients considered not to be eligible for TAVI. The Shapiro-Wilk test was applied to evaluate normality. Non-paired t and Mann-Whitney tests were applied for continuous variables, while the chi-squared and Fischer exact tests were applied for categorical variables, with a level of significance of p<0,05. RESULTS: The heart team evaluated 475 patients: 25 (5.26%) died before any intervention could be proposed; 326 (68.3%) were submitted to TAVI, so the study population consisted of 124 patients not eligible for TAVI. Of these, 31 (25%) underwent surgery and 93 (75%) remained in clinical treatment. In a mean 56 months- follow-up the mortality in clinical group was 46.2%. In the surgical group the mortality was 23.9% (in-hospital 12.9% and late mortality 11% in a mean 47.4 months follow-up). The patients that died presented a significantly lower left ventricle ejection fraction (LVEF), a smaller valve area, and a larger end-systolic diameter of the LV. CONCLUSION: The mortality of the clinical group's patients was significantly higher than the surgical mortality (46.2% vs. 12.9%; p=0.021). The patients of the clinical group were older, weighed less, and had a higher incidence of renal failure and a higher STS score.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Estudos Retrospectivos
12.
Catheter Cardiovasc Interv ; 97(1): E95-E103, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32301250

RESUMO

INTRODUCTION: Few data exist regarding the late clinical impact of the Selvester score prediction of myocardial fibrosis after transcatheter aortic valve replacement (TAVR). This study evaluated the predictive power of the Selvester score on survival in patients with aortic stenosis (AS) undergoing TAVR. METHODS AND RESULTS: Patients with severe AS who had preoperative electrocardiograms were included. Clinical follow-up was obtained retrospectively. The primary endpoint was all-cause mortality. Secondary endpoints were cardiovascular death and major adverse cardiac events (MACEs). Two-hundred twenty-eight patients were included (mean age, 81.5 ± 7.4 years; women, 58.3%). Deceased patients had a higher mean score (4.6 ± 3.2 vs. 1.4 ± 1.3; p < .001). At a mean follow-up of 36.2 ± 21.2 months, the Selvester score was independently associated with all-cause mortality (hazard ratio [HR], 1.65; 95% confidence interval [CI], 1.48-1.84; p < .001), cardiovascular death (HR, 1.59; 95% CI, 1.38-1.74; p < .001), and MACE (HR, 1.55; 95% CI, 1.30-1.68; p < .001). After 5 years, the mortality risk was incrementally related to the Selvester score. The involvement of the inferior wall of the left ventricle was a lower mortality risk factor (HR, 0.42; 95% CI, 0.18-0.98; p = .046). For a Selvester score of 3, the area under the curve showed 0.92, 0.94, and 0.86 (p < .001), respectively, for 1, 2, and 3 years. CONCLUSIONS: Elevated Selvester scores increase the risk of poor outcomes in patients with AS undergoing TAVR. The involvement of the anterior or lateral wall presents worse prognosis.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 97(1): 167-174, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445607

RESUMO

OBJECTIVES: The aim of the study was to evaluate mid- to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with Acurate neo™ (Boston Scientific, Boston, MA). BACKGROUND: TAVR is an established treatment for aortic stenosis (AS). Few data exist on mid- to long-term outcomes and durability after new-generation valves. METHODS: All consecutive patients (n = 104) who underwent Acurate neo™ implantation from 2012 to 2018 were included. Follow-up was systematically performed at 1, 6, 12, and 24 months and yearly thereafter. Outcomes were reported according to VARC-2, and structural valve deterioration (SVD) or bioprosthetic valve failure defined accordingly to new definitions. RESULTS: Mean age was 82 ± 5.4 years, 56.7% were female and the Society of Thoracic Surgeons score for mortality was 5.9 ± 4%. Patients were followed for a median of 3 years (1,092 days; IQR 1.5-4 years), and the maximum follow-up was 7 years. All-cause mortality values at 1 and 5 years were 8.5% and 40.5%, respectively. No relevant changes in mean gradient and orifice area occurred (7.9 ± 3.8 mmHg and 1.9 ± 0.3 cm2 at 1 year; 6.6 ± 2.1 mmHg and 1.8 ± 0.3 cm2 at 5 years), and there was a significant rate of paravalvular leaks resolution at 1, 2, and 3 years (p = .004; p < .001; p < .001, respectively). None of the patients had leaflet thrombosis or endocarditis. One patient developed SVD at 84 months. CONCLUSIONS: Acurate neo™ was associated with sustained echocardiographic results. Reassuring mid- to long-term outcomes was observed in this cohort of elderly patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Arq. bras. cardiol ; 115(3): 558-568, out. 2020. ilus, tab, graf
Artigo em Inglês, Português | SES-SP, LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1129857

RESUMO

Introdução A pandemia global da doença de coronavírus 2019 (COVID-19) causada pelo novo vírus de síndrome respiratória aguda grave coronavírus 2 (SARS-CoV-2) começou em Wuhan, China, em dezembro de 2019 e afetou mais de 4,4 milhões de pessoas em todo o mundo, com 302.169 mortes até o dia 16 de maio de 2020.1 Embora os sintomas respiratórios sejam a apresentação mais comum de COVID-19, o envolvimento cardíaco é uma característica proeminente dessa doença, ocorrendo em 20% a 30% dos pacientes hospitalizados e contribuindo para 40% dos óbitos.2-4 O envolvimento cardíaco relacionado à COVID-19 tem sido documentado por elevações em biomarcadores cardíacos e frequentemente apresenta alterações no segmento ST-T no eletrocardiograma (ECG) de 12 derivações, motivo pelo qual a equipe do laboratório de cateterismo é frequentemente ativada. Além disso, as atividades do laboratório de cateterismo devem continuar no atendimento a pacientes não COVID-19 que apresentam síndrome coronariana aguda (SCA) verdadeira, infarto do miocárdio com supradesnivelamento do segmento ST (IAMCSST) e doença cardíaca isquêmica estável muito sintomática. Devido à escalada no número de casos de COVID-19 na cidade de São Paulo, epicentro da doença no Brasil, reformularam-se a logística e as práticas no laboratório de cateterismo cardíaco do Instituto Dante Pazzanese de Cardiologia, que entraram em vigor em abril de 2020 e continuarão durante o período da pandemia. Os objetivos são fornecer atendimento otimizado à população que necessita de procedimentos cardíacos invasivos durante a pandemia, com a proteção adequada aos profissionais de saúde (PS), pacientes e seus familiares. Os protocolos aqui descritos representam os esforços multidisciplinares e dinâmicos do Departamento de Cardiologia Invasiva do Instituto Dante Pazzanese de Cardiologia validados pelo Comitê de Controle de Infecção da instituição. Essas práticas estão sujeitas a alterações em função do estado epidemiológico local, a fase da epidemia e a disponibilidade de equipamento de proteção individual (EPI). Estes protocolos podem não se aplicar a outras localidades sem casos (ou casos esporádicos) de COVID-19 ou a serviços que atendem diferentes perfis populacionais com logísticas e disponibilidade de EPI diversas.


Assuntos
Infecções por Coronavirus , Betacoronavirus , Doenças Cardiovasculares , Guia de Prática Clínica , Habilidades para Realização de Testes , Reestruturação Hospitalar
18.
Am J Cardiol ; 125(9): 1369-1377, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32098656

RESUMO

Safety and feasibility of transfemoral Acurate neo implantation without systematic predilatation are not fully investigated. Our aim was to evaluate the use and impact of pre-implantation balloon aortic valvuloplasty (pre-BAV) before transcatheter aortic valve implantation (TAVI) with Acurate neo. The NEOPRO Registry retrospectively included 1,263 patients who underwent transfemoral TAVI with Acurate neo at 18 centers between January 2012 and March 2018. Information on pre-BAV was available for 1,262 patients (99.9%). Primary end points were pre-discharge moderate-to-severe paravalvular aortic regurgitation (PAR II+), 30-day new permanent pacemaker implantation, and 30-day all-cause mortality or stroke. A total of 1,262 patients who underwent TAVI with (n = 1,051) or without predilatation (n = 211) were included. A reduction in the pre-BAV rate was observed during the study period (from 95.7% in the first date quintile to 78.4% in the last date quintile). Patients who underwent pre-BAV had higher degrees of aortic valve (AV) and left ventricular outflow tract (LVOT) calcification. Primary endpoints were similar between pre-BAV and no pre-BAV groups (PAR II+ 5.5% vs 3.4%, p = 0.214; 30-day permanent pacemaker implantation 9.0% vs 8.0%, p = 0.660; 30-day death or stroke 4.9% vs 4.4%, p = 0.743). The need for postdilatation and other procedural outcomes were comparable between groups. Predilatation did not have a significant impact on primary endpoints across AV and LVOT calcification subgroups (subgroup analyses) and was not independently associated with primary endpoints (multivariate analyses). In conclusion, transfemoral Acurate neo implantation without predilatation appears to be feasible and safe, especially in patients with milder degrees of AV and LVOT calcification.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Dilatação/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Período Pré-Operatório , Sistema de Registros , Estudos Retrospectivos
19.
JACC Cardiovasc Interv ; 12(16): 1606-1617, 2019 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-31439340

RESUMO

OBJECTIVES: This study sought to evaluate SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, California) positioning using different strategies. BACKGROUND: Aortic valve-in-valve (ViV) is associated with high risk of elevated gradients. METHODS: S3 aortic ViV procedures in stented bioprostheses were studied. Transcatheter heart valve (THV) positioning was analyzed in a centralized core lab blinded to clinical outcomes. A combined endpoint of severely elevated mean gradient (≥30 mm Hg) or pacemaker need was established. Two positioning strategies were compared: central marker method and top of S3 method. Optimal final depth was defined as S3 depth ≤20%. RESULTS: A total of 113 patients met inclusion criteria and were analyzed (76.5 ± 9.7 years of age, 65.8% male, STS score 8 ± 7.6%). THVs had incomplete shortening in comparison to fully expanded valves (92 ± 3.4%), and expansion was more complete in optimal positioning cases compared with others (93.2 ± 2.7% vs. 91.5 ± 3.5%; p = 0.027). The central marker method demonstrated greater correlation with final implantation depth than the top of S3 method (R2 of 0.48 and 0.14; p < 0.001 and p = 0.001, respectively). The combined endpoint rate was 4.3% in the optimal (higher than 3 mm) implantation group, 12% in the intermediate group, and 50% in the low group (p < 0.001). There were no cases of THV embolization. In cases with central marker higher than 3 mm, 72.4% had optimal final depth. In those with central marker higher than 6 mm, 90% had optimal final depth. CONCLUSIONS: Optimal S3 positioning in aortic ViV is associated with better outcomes. Central marker positioning is more reliable than top of S3 positioning. Central marker bottom position should be 3 mm to 6 mm above the ring.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
JACC Cardiovasc Interv ; 12(5): 433-443, 2019 03 11.
Artigo em Inglês | MEDLINE | ID: mdl-30846081

RESUMO

OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: In this multicenter registry, transfemoral TAVR with the NEO and PRO bioprostheses was associated with high device success, acceptable rates of paravalvular aortic regurgitation II+, and good 30-day clinical outcomes. After adjusting for potential confounders, short-term outcomes were similar between the devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA