Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 20587, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37996563

RESUMO

Different biomaterials have been clinically used as bone filling materials, although the mechanisms behind the biological effects are incompletely understood. To address this, we compared the effects of five different biomaterials: two bioactive glasses (45S5 and S53P4), hydroxyapatite (HAP), carbonated apatite (CAP), and alumina on the in vitro migration and viability of pre-osteoblastic cells. In addition, we studied the effects of biomaterials' calcium release on cell migration, viability and differentiation. We found differences between the materials as the bioactive glasses promoted rapid pre-osteoblastic cell migration. In contrast, CAP decreased cell migration, which was also associated with lower activity of migration related kinases. Bioactive glasses released significant amounts of calcium into the media, while CAP decreased the calcium concentration. The response of cells to calcium was mechanistically studied by blocking calcium sensing receptor (CaSR) and ATP-gated ion channel P2X7, but this had no effect on cell migration. Surprisingly, HAP and CAP initially decreased cell viability. In summary, bioactive glasses 45S5 and S53P4 had significant and long-lasting effects on the pre-osteoblastic cell migration, which could be related to the observed calcium dissolution. Additionally, bioactive glasses had no negative effects on cell viability, which was observed with HAP and CAP.


Assuntos
Cálcio , Durapatita , Durapatita/farmacologia , Materiais Biocompatíveis , Vidro , Apatitas , Cálcio da Dieta , Movimento Celular
2.
Dent Mater ; 38(12): 1878-1885, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36207169

RESUMO

OBJECTIVES: A tribochemical silica-coating (TSC) method has been developed to improve the adhesion of dental resin composites to various substrates. The method utilizes airborne-particle abrasion using particles having a silica surface and an alumina core. The impact of the TSC method has been extensively studied but less attention has been paid to the characterization of the silica-modified alumina particles. Due to the role of silicate ions in cell biology, e.g. osteoblast function and bone mineralization, silica-modified alumina particles could also be potentially used as a biomaterial in scaffolds of tissue regeneration. Thus, we carried out detailed physicochemical characterization of the silica-modified alumina particles. METHODS: Silica-modified alumina particles (Rocatec, 3 M-ESPE) of an average particle size of 30 µm were studied for the phase composition, spectroscopic properties, surface morphology, dissolution, and the capability to modify the pH of an immersion solution. The control material was alumina without silica modification. Pre-osteoblastic MC3T3-E1 cells were used to assess cell viability in the presence of the particles. Cell viability was tested at 1, 3, 7 and 10 days of culture with various particle quantities. Multivariate ANOVA was used for statistical analyses. RESULTS: Minor quantities of silica enrichment was verified on the surface of alumina particles and the silica did not evenly cover the alumina surface. In the dissolution test, no change in the pH of the immersion solution was observed in the presence of the particles. Minor quantities of silicate ions were dissolved from the particles to the cell culture medium but no major differences were observed in the viability of pre-osteoblastic cells, whether the cells were cultured with silica-modified or plain alumina particles. SIGNIFICANCE: Characterization of silica-modified alumina particles demonstrated differences in the particle surface structure compared to control alumina. Dissolution of silica layer in Tris buffer or SBF solution varied from that of cell culture medium: minor quantities of dissolved Si were observed in cell culture test medium. The cell viability test did not shown significant differences between control alumina and its silica-modified counterpart.


Assuntos
Óxido de Alumínio , Colagem Dentária , Óxido de Alumínio/química , Resinas Compostas/química , Colagem Dentária/métodos , Teste de Materiais , Cimentos de Resina/química , Silicatos/química , Dióxido de Silício/química , Propriedades de Superfície , Zircônio/química
3.
Dent Mater ; 37(9): 1350-1357, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34175132

RESUMO

OBJECTIVE: Clinically used bioceramics have been characterized previously with different kinds of methods and comparison of results have proven to be difficult due to varieties of the material properties of interest. Therefore, in this study we compared clinically commonly used bioceramics of hydroxyapatite and carbonate apatite, two bioactive glasses 45S5 and S53P4, and alumina with respect of properties which according to the present knowledge are significant for bone biology. METHODS: Physicochemical properties of the materials were characterized by various methods. Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) was used to analyze the material vibrational features. X-ray Power Diffraction (XRD) was used to characterize the material crystal structure and scanning electron microscopy-energy-dispersive x-ray analysis (SEM-EDXA) was used to evaluate the morphology and size of the materials and to calculate their oxide content. The dissolution behavior of the materials, ion release and pH changes in Tris buffer in a continuous flow-through reaction for 24-hours were determined. The change of the surface of the bioactive glasses by interfacial reaction during the Tris immersion was examined and the thickness of the surface reaction layer of the materials was studied. RESULTS: SEM examination showed that the particle morphology of BG 45S5, BG S53P4 and alumina particle's surface was smooth. The surface of HAP was porous, but also CAP showed some surface porosity. An increase in the pH of the immersion solution was observed especially for BG 45S5 and BG S53P4. HAP, CAP and alumina caused only a minor increase in pH. BGs 45S5 and S53P4 showed a rapid initial release of sodium and calcium ions, followed by the release of silicon species. Minor release of sodium ions was registered for HAP, CAP and alumina. Calcium ion release was low but constant over the experimental time while only a minor initial dissolution was measured for HAP. SIGNIFICANCE: The in vitro study showed differences in the materials' properties, which are considered to be important for biological suitability and in clinical applications, such as materials tomography, ion release and pH changes.


Assuntos
Materiais Biocompatíveis , Cerâmica , Durapatita , Vidro , Porosidade , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA