Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Infect Dis (Lond) ; : 1-9, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39150281

RESUMO

BACKGROUND: India relies primarily on direct smear microscopy for tuberculosis (TB) diagnosis. However, the low sensitivity of smear microscopy emphasizes the need to improve its performance. We recently described the development of 'TBDetect' kit which showed improved performance over direct smear microscopy at National Reference Laboratories (NRLs) in India. METHODS: The present study was aimed to assess the operational feasibility of 'TBDetect' microscopy in field settings. This was evaluated by (i) assessing the performance of 'TBDetect' microscopy vs. LED-fluorescence microscopy (LED-FM) on consecutive presumptive pulmonary TB patients (n = 5300) who attended Designated Microscopy Centres (DMCs, n = 13) under 4 NRLs at Bhubaneswar, Bhopal, Chennai, and New Delhi, and (ii) obtaining feedback from Scientists (n = 10) and laboratory technicians (n = 42) using semi-structured questionnaires under the following parameters: feasibility of initiation of 'TBDetect' microscopy in DMCs, sample preparation and testing, training, time-to-result, logistics, and troubleshooting. A scoring questionnaire was also used to assess 'TBDetect' microscopy vs. LED-FM and statistical significance of the scores was calculated using paired t-test. RESULTS: The overall positivity of 'TBDetect' microscopy was 10.32% (547/5300) vs. 8.96% (475/5300) of LED-FM at all sites and the increment in positivity was significant (p = 0.019). In addition, 'TBDetect' microscopy yielded an increment in smear grade status over LED-FM (p = 0.043). The feedback from the study-in-charge and kit users indicated that 'TBDetect' microscopy was easily adapted in point-of-care settings. An analysis of scoring feedback suggested that it was easy to perform and observe in comparison to LED-FM (p < 0.005). CONCLUSIONS: This study established the feasibility of 'TBDetect' microscopy in field settings.

2.
ERJ Open Res ; 7(3)2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34350282

RESUMO

BACKGROUND: Near-patient access to appropriate tests is a major obstacle for the efficient diagnosis of tuberculosis (TB) and associated drug resistance. METHODS: We recently developed the "TB Concentration & Transport" kit for bio-safe, ambient-temperature transportation of dried sputum on Trans-Filter, and the "TB DNA Extraction" kit for DNA extraction from Trans-Filter for determining drug resistance by DNA sequencing. In the present study, we evaluated the compatibility of Kit-extracted DNA with Hain's line probe assays (LPAs), which are endorsed by National TB programmes for the detection of drug resistance in sputum collected from presumptive multidrug-resistant TB patients (n=207). RESULTS: Trans-Filter-extracted DNA was seamlessly integrated with the LPA protocol (Kit-LPA). The sensitivity of Kit-LPA for determining drug resistance was 83.3% for rifampicin (95% CI 52-98%), 77.7% for isoniazid (95% CI 52-94%), 85.7% for fluoroquinolones (95% CI 42-100%) and 66.6% for aminoglycosides (95% CI 9-99%), with a specificity range of 93.7% (95% CI 87-97) to 99.1% (95% CI 95-100) using phenotypic drug susceptibility testing (DST) as a reference standard. A high degree of concordance was noted between results obtained from Kit-LPA and LPA (99% to 100% (κ value: 0.83-1.0)). CONCLUSIONS: This study demonstrates successful integration of our developed kits with LPA. The adoption of these kits across Designated Microscopy Centres in India can potentially overcome the existing challenge of transporting infectious sputum at controlled temperature to centralised testing laboratories and can provide rapid near-patient cost-effective "Universal DST" services to TB subjects residing in remote areas.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA