Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Biol Open ; 13(7)2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38885005

RESUMO

Metabolic syndrome has become a global epidemic, affecting all developed countries and communities with growing economies. Worldwide, increasing efforts have been directed at curbing this growing problem. Mice deleted of the gene encoding Type 1 Transient Receptor Potential Canonical Channel (Trpc1) were found to weigh heavier than controls. They had fasting hyperglycemia and impaired glucose tolerance compared with wild-type controls. Beyond 1 year of age, plasma triglyceride level in Trpc1-/- mice was elevated. Plasma cholesterol levels tended to be higher than in controls. The livers of Trpc1-/- mice were heavier, richer in triglyceride, and more echogenic than those of controls on ultrasound evaluation. Hematocrit was lower in Trpc1-/- mice of both genders beginning at the second to third months of age in the absence of bleeding or hemolysis. Measured by the indirect tail-cuff method or by the direct arterial cannulation, blood pressures in null mice were lower than controls. We conclude that TRPC1 gene regulates body metabolism and that except for hypertension, phenotypes of mice after deletion of the Trpc1 gene resemble mice with metabolic syndrome, suggesting that this could be a good experimental model for future investigation of the pathogenesis and management of this disorder.


Assuntos
Modelos Animais de Doenças , Síndrome Metabólica , Camundongos Knockout , Canais de Cátion TRPC , Animais , Canais de Cátion TRPC/genética , Canais de Cátion TRPC/metabolismo , Canais de Cátion TRPC/deficiência , Camundongos , Síndrome Metabólica/etiologia , Síndrome Metabólica/metabolismo , Síndrome Metabólica/genética , Pressão Sanguínea , Fenótipo , Masculino , Feminino
2.
Anat Sci Educ ; 17(1): 11-23, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37850629

RESUMO

Growth in the online survey market may be increasing response burden and possibly jeopardizing higher response rates. This meta-analysis evaluated survey trends over one decade (2011-2020) to determine: (1) changes in survey publication rates over time, (2) changes in response rates over time, (3) typical response rates within health sciences education research, (4) the factors influencing survey completion levels, and (5) common gaps in survey methods and outcomes reporting. Study I estimated survey publication trends between 2011 and 2020 using articles published in the top three health sciences education research journals. Study II searched the anatomical sciences education literature across six databases and extracted study/survey features and survey response rates. Time plots and a proportional meta-analysis were performed. Per 2926 research articles, the annual estimated proportion of studies with survey methodologies has remained constant, with no linear trend (p > 0.050) over time (Study I). Study II reported a pooled absolute response rate of 67% (95% CI = 63.9-69.0) across 360 studies (k), totaling 115,526 distributed surveys. Despite response rate oscillations over time, no significant linear trend (p = 0.995) was detected. Neither survey length, incentives, sponsorship, nor population type affected absolute response rates (p ≥ 0.070). Only 35% (120 of 339) of studies utilizing a Likert scale reported evidence of survey validity. Survey response rates and the prevalence of studies with survey methodologies have remained stable with no linear trends over time. We recommend researchers strive for a typical absolute response rate of 67% or higher and clearly document evidence of survey validity for empirical studies.


Assuntos
Anatomia , Anatomia/educação , Inquéritos e Questionários , Escolaridade , Motivação
3.
Environ Toxicol Chem ; 41(11): 2658-2666, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35920352

RESUMO

Active pharmaceutical ingredient (API) contamination of water sources, including opioid contamination, has become more common in recent years. Although drinking water-treatment plants help mitigate API infiltration, API contamination remains in some drinking water sources. Therefore, the ability to detect APIs at ultratrace concentrations is vital to ensure safe drinking water. A method for the ultratrace determination of fentanyl, hydrocodone, and codeine in drinking water via direct injection and high-performance liquid-chromatography tandem mass spectrometry (HPLC-MS/MS) was developed and validated. Drinking water samples (10 ml) are simply syringe-filtered and then analyzed by HPLC-MS/MS. A wide linear range (0.25-100 ng/L) and ultratrace limits of detection (80, 150, and 500 pg/L for fentanyl, hydrocodone, and codeine, respectively) were features of the method. The method produced excellent aggregate accuracies of 90%-115% and precisions of ≤11% for the three analytes tested. This method was used to test drinking water samples from 53 US locations, with hydrocodone and codeine detected in approximately 40% of the samples tested at concentrations between 0.3 and 20 ng/L. Codeine was detected at higher concentrations than hydrocodone (up to 7.3 times) for each sample containing these APIs. Fentanyl was not detected in any field drinking water sample. The detection of opioids in a large fraction of the US drinking water samples tested is cause for concern, and these levels should continue to be monitored to ensure that they do not become a threat to human health. Environ Toxicol Chem 2022;41:2658-2666. © 2022 SETAC.


Assuntos
Água Potável , Humanos , Água Potável/química , Cromatografia Líquida de Alta Pressão , Analgésicos Opioides/análise , Espectrometria de Massas em Tandem/métodos , Hidrocodona/análise , Cromatografia Líquida/métodos , Prevalência , Codeína/análise , Preparações Farmacêuticas
4.
J Chromatogr A ; 1659: 462493, 2021 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-34706316

RESUMO

Detection of drinking water contaminants is vital to the protection of human health. One group of contaminants that have recently generated serious concerns over health risks are per- and polyfluoroalkyl substances (PFAS). These compounds are very bio-persistent, leading to their detection in all types of water sources, including drinking water. While analysis of drinking water for PFAS is important, it is currently arduous to detect ultratrace levels of these contaminants. Specifically, current ultratrace PFAS analysis methods are difficult, costly, require large sample volumes, and consume relatively large volumes of organic solvent. In the present work, an analytical method using Ice Concentration Linked with Extractive Stirrer (ICECLES) and high performance liquid chromatography-tandem quadrupole mass spectrometry (HPLC-MS/MS), was developed and validated to provide simple and ultratrace analysis of drinking water for 14 PFAS. The method featured a relatively low sample volume requirement (10 mL), automated extraction, minimal matrix effects, and minimal organic solvent use (i.e., the method requires only 50 µL of methanol per sample). The method produced a wide linear range of 0.5 to 500 ng/L, ultratrace limits of detection (0.05 to 0.3 ng/L), and good accuracy and precision (i.e., 87 to 108% accuracy and ≤19% relative standard deviation as a measure of precision). This method was tested on drinking water samples from across the United States and detected at least one PFAS compound in 52 of the 53 drinking water samples tested. Perfluorohexanoic acid (PFHxA), perfluorooctanoic acid (PFOA), and perfluoroheptanoic acid (PFHpA) were detected in 89, 96, and 77% of the samples tested with maximum concentrations of 268 ng/L for PFHxA, 213 ng/L for PFOA, and 75.7 ng/L for PFHpA. Additionally, perfluorononanoic acid, perfluorodecanoic acid, and perfluoroheptanoic acid were each detected in at least one drinking water sample at concentrations > 20 ng/L. The availability of the method presented here allows ultratrace detection of PFAS while circumventing many of the disadvantages of current methods.


Assuntos
Água Potável , Poluentes Químicos da Água , Cromatografia Líquida de Alta Pressão , Humanos , Gelo , Espectrometria de Massas em Tandem , Poluentes Químicos da Água/análise
5.
J Chromatogr A ; 1635: 461753, 2021 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-33285417

RESUMO

Atrazine is a widely-used pesticide with a relatively long half-life in the environment. This leads to persistent soil contamination with the potential of migration to ground and surface waters. Analysis of atrazine in soil is difficult due to the inherent complexity of soil as a sample matrix. Moreover, the moderate hydrophobicity of atrazine makes it difficult to extract into typical sorbent phases during sample preparation. Therefore, a method for the ultratrace determination of atrazine in soil using Ice Concentration Linked with Extractive Stirrer (ICECLES) and high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed to address these issues. For the method, soil samples (10 g) were initially extracted with methanol:water (8:2, v:v), followed by solvent exchange to 100% water. The samples then underwent ICECLES with back-extraction into 100% methanol prior to HPLC-MS/MS analysis. The ICECLES-HPLC-MS/MS method produced a wide linear range of 10 to 1000 ng/kg, featured excellent limits of quantification and detection of 10 and 5 ng/kg, respectively, and good accuracy (100 ± 12%) and precision (≤9.6% relative standard deviation). This method was tested on field soil samples and provided ultratrace detection of atrazine. With this method, previously unachievable low parts per trillion (ppt) detection of atrazine in soil is now possible.


Assuntos
Atrazina/análise , Cromatografia Líquida de Alta Pressão , Monitoramento Ambiental/métodos , Solo/química , Espectrometria de Massas em Tandem , Praguicidas/análise , Poluentes do Solo/análise
6.
J Chromatogr A ; 1622: 461102, 2020 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-32389418

RESUMO

With the advent of highly selective analysis techniques (e.g., liquid chromatography-tandem mass spectrometry), and lower limits of detection requirements, extraction efficiency is arguably the most important property of modern sample preparation techniques. In this study, the extraction efficiency of Ice Concentration Linked with Extractive Stirrer (ICECLES) was compared to Stir Bar Sorptive Extraction (SBSE) and Solid-Phase Microextraction (SPME). A direct comparison of these sample preparation techniques was carried out with analysis via both Liquid Chromatography - Tandem Mass Spectrometry (LC-MS/MS) and Thermal Desorption Gas Chromatography - Mass Spectrometry (TD-GC-MS). ICECLES produced 2x and 7x greater TD-GC-MS signals than SBSE and SPME, respectively. When comparing extraction techniques for a suite of 60 pesticides in drinking water, 32, 25, and 13 pesticides were detected via LC-MS/MS at 0.1 ng/mL by ICECLES, SBSE, and SPME, respectively. Overall, ICECLES consistently produced better extraction efficiencies than the other extraction techniques evaluated.


Assuntos
Água Potável/química , Praguicidas/análise , Praguicidas/isolamento & purificação , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Cromatografia Líquida , Cromatografia Gasosa-Espectrometria de Massas , Gelo , Microextração em Fase Sólida , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA