Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(3): 033502, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35364968

RESUMO

The gasdynamic electron cyclotron resonance (ECR) ion source is a type of the device in which the ionization efficiency is achieved primarily due to a high plasma density. Because of a high particle collision rate, the confinement is determined by a gasdynamic plasma outflow from a magnetic trap. Due to high efficiency of resonant heating, electrons gain energy significantly higher than that in inductively or capacitively coupled plasmas. As a consequence of such a parameter combination, the gasdynamic ECR plasma can be a unique source of low to medium charged ions, providing a high current and an ultimate quality of an ion beam. One of the most demanded directions of its application today is a development of high-current proton injectors for modern accelerators and neutron sources of different intensities. Special plasma parameters allow for the use of diagnostic techniques, traditional for multiply charged ECR plasmas as well as for other types of discharges with a high plasma density. Among the additional techniques, one can mention the methods of numerical simulation and reconstruction of the plasma density and temperature from the parameters of the extracted ion beams. Another point is that the high plasma density makes it possible to measure it from the Stark broadening of hydrogen lines by spectroscopy of plasma emission in the visible range, which is a fairly convenient non-invasive diagnostic method. The present paper discusses the main physical aspects of the gasdynamic ECR plasma, suitable diagnostic techniques, and possibilities and future prospects for its various applications.

2.
Rev Sci Instrum ; 93(4): 043501, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35489927

RESUMO

To ensure further progress in the development of electron cyclotron resonance ion sources (ECRISs), deeper understanding of the underlying physics is required. The electron energy distribution (EED), which is crucial for the performance of an ECRIS, still remains obscure. The present paper focuses on the details of a well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS. The method allows for better than 500 eV energy resolution over a range of electron energies from 4 keV to over 1 MeV. We present detailed explanation of the experimental procedure and the following data processing peculiarities with examples and discuss possible reasons of energetic electron losses from the magnetic trap, in particular the role of RF pitch angle scattering. Finally, an experimental method of approximating the confined EED based on the measurement of escaping electrons is described.

3.
Rev Sci Instrum ; 91(1): 013502, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012519

RESUMO

Further progress in the development of electron cyclotron resonance (ECR) ion sources (ECRISs) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of the EED in an unstable mode of plasma confinement, i.e., in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences between the EED escaping from stable and unstable plasmas. It was found that nonlinear phenomena alter the EED noticeably. The electron losses are enhanced in both unstable regimes, with two-frequency heating suppressing the instabilities. It has been shown earlier that two-frequency heating boosts the ECRIS performance presumably owing to the suppression of instabilities. We report the observed changes in EED introduced by the secondary frequency in different regimes, including an off-resonance condition, where the secondary frequency is lower than the minimum frequency satisfying the resonance condition for cold electrons at the magnetic field minimum. Finally, we suggest an experimental method of qualitative evaluation of the energy distribution of electrons confined in the magnetic trap using a method of measuring energy distribution of lost electrons during the plasma decay in pulsed operation of the ion source.

4.
Rev Sci Instrum ; 91(1): 013331, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012579

RESUMO

The paper presents recent results of a "pointlike" neutron source development based on a D-D fusion in a D-loaded target caused by its bombardment with a sharply focused deuterium ion beam. These developments are undergoing at the Institute of Applied Physics of Russian Academy of Sciences in order to study a possibility to create an effective and compact device for fast-neutron radiography. The last experiments with a beam produced by a gasdynamic high-current ECR ion source and its focusing with a magnetic lens demonstrated that 60 mA of deuterium ions may be constricted to a transversal size of ∼1 mm at the focal plane. With a purpose to improve this result in terms of the beam current and its size, a combined electrostatic and magnetic focusing system is proposed and analyzed. It is shown that the combined system may enhance the total beam current and reduce its footprint down to 0.13 mm. All numerical analysis was performed using the IBSimu code.

5.
Rev Sci Instrum ; 91(1): 013517, 2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012642

RESUMO

Negative hydrogen ion sources are used as injectors into accelerators and drive the neutral beam heating in ITER. Certain processes in low-temperature hydrogen plasmas are accompanied by the emission of vacuum ultraviolet (VUV) emission. Studying the VUV radiation, therefore, provides volumetric rates of plasma-chemical processes and plasma parameters. In the past, we have used gasdynamic ECR discharge for volumetric negative ion production and investigated the dependencies between the extracted H- current density and various ion source parameters. It was shown that it is possible to reach up to 80 mA/cm2 of negative ion current density with a two electrode extraction. We report experimental studies on negative hydrogen ion production in a high-density gasdynamic ECR discharge plasma consisting of two simple mirror traps together with the results of VUV emission measurements. The VUV-power was measured in three ranges-Lyα, Lyman band, and molecular continuum-varying the source control parameters near their optima for H- production. It was shown that the molecular continuum emission VUV power is the highest in the first chamber while Lyα emission prevails in the second one. Modifications for the experimental scheme for further optimization of negative hydrogen ion production are suggested.

6.
Rev Sci Instrum ; 90(11): 113321, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31779446

RESUMO

The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the plasma at high densities. Parallel to the technical development of the ion sources themselves, significant effort has been directed into the development of their plasma diagnostic tools. We review the recent results of Electron Cyclotron Resonance Ion Source (ECRIS) plasma diagnostics highlighting a number of selected examples of plasma density, electron energy distribution, and ion confinement time measurements, obtained mostly with the second-generation sources operating at frequencies from 10 to 18 GHz. The development of minimum-B ECR ion sources based on the superposition of solenoid and sextupole fields has long relied on semiempirical scaling laws for the strength of the magnetic field with increasing plasma heating frequency. This approach is becoming increasingly difficult with the looming limits of superconducting technologies being able to satisfy the magnetic field requirements at frequencies approaching 60 GHz. Thus, we discuss alternative ECRIS concepts and proposed modifications to existing sources that are supported by the current understanding derived from the plasma diagnostics experiments.

7.
Rev Sci Instrum ; 90(12): 123511, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893772

RESUMO

Results of experimental investigation of the ECR discharge in a single coil magnetic field as an alternative to rf and helicon discharges for wide-aperture dense plasma fluxes production are presented. A possibility of obtaining wide-aperture high density hydrogen plasma fluxes with homogeneous transverse distribution was demonstrated in such a system. The prospects of using this system for obtaining high current ion beams are discussed.

8.
Rev Sci Instrum ; 90(12): 123303, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893842

RESUMO

Electron Cyclotron Resonance Ion Source (ECRIS) plasmas are prone to kinetic instabilities resulting in loss of electron and ion confinement. It is demonstrated that the biased disk of an ECRIS can be used as a probe to quantify such instability-induced electron and ion losses occurring in less than 10 µs. The qualitative interpretation of the data is supported by the measurement of the energy spread of the extracted ion beams implying a transient plasma potential >1.5 kV during the instability. A parametric study of the electron losses combined with electron tracking simulations allows for estimating the fraction of electrons expelled in each instability event to be on the order of 10% of the total electron population.

9.
Rev Sci Instrum ; 90(12): 123308, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31893846

RESUMO

A new experimental facility named GISMO (Gasdynamic Ion Source for Multipurpose Operation) was constructed at the IAP RAS to continue investigations in the field of gasdynamic ion sources. The source utilizes 28 GHz/10 kW gyrotron radiation for heating magnetically confined plasma. Magnetic field configuration provided by a fully permanent magnet system is much like a simple mirror trap. The GISMO source is aimed at the production of bright ion beams with hundreds of milliamperes current. The facility has been tested for continuous-wave (CW) operation with 2 kW of heating power to check durability of a microwave injection system and the plasma chamber. A 2-electrode extraction system with an integrated Einzel lens was designed for a formation of CW high current beam with up to 100 kV accelerating voltage. The first results on ion beam production at GISMO are presented together with the general progress status of the facility.

10.
Rev Sci Instrum ; 89(5): 052302, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864837

RESUMO

The conceptual design of a fourth generation hybrid electron cyclotron resonance (ECR) ion source operated at 60 GHz is proposed. The axial magnetic mirror is generated with a set of three Nb3Sn coils, while the hexapole is made with room temperature (RT) copper coils. The motivations for such a hybrid development are to study further the ECR plasma physics and the intense multicharged ion beams' production and transport at a time when a superconducting (SC) hexapole appears unrealistic at 60 GHz. The RT hexapole coil designed is an evolution of the polyhelix technology developed at the French High Magnetic Field Facility. The axial magnetic field is generated by means of 3 Nb3Sn SC coils operated with a maximum current density of 350 A/mm2 and a maximum coil load line factor of 81%. The ECR plasma chamber resulting from the design features an inner radius of 94 mm and a length of 500 mm. The radial magnetic intensity is 4.1 T at the wall. Characteristic axial mirror peaks are 8 and 4.5 T, with 1.45 T minimum in between.

11.
Phys Rev Lett ; 120(15): 155001, 2018 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-29756884

RESUMO

We report the first experimental evidence of a controlled transition from the generation of periodic bursts of electromagnetic radiation into the continuous-wave regime of a cyclotron maser formed in magnetically confined nonequilibrium plasma. The kinetic cyclotron instability of the extraordinary wave of weakly inhomogeneous magnetized plasma is driven by the anisotropic electron population resulting from electron cyclotron plasma heating in a MHD-stable minimum-B open magnetic trap.

12.
Rev Sci Instrum ; 88(3): 033503, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372417

RESUMO

Plasma of electron cyclotron resonance (ECR) discharge sustained by millimeter wave radiation is widely used for production of ion beams of different kind. The main trend in ECR ion sources development nowadays is an increase of frequency and power of microwave heating. The most advanced systems use gyrotrons in 24-60 GHz frequency range. In previous studies at IAP RAS it was demonstrated that ECR source SMIS 37 (Simple Mirror Ion Source) with 37.5 GHz heating operating in quasigasdynamic regime of plasma confinement is able to produce proton and deuteron beams with ion current density about 700 mA/cm2. As the next step of these investigations plasma properties of the discharge sustained by 75 GHz radiation have been studied. Plasma density and electron temperature were determined using spectroscopic and Langmuir probe techniques. It was demonstrated that plasma density could reach values close to 1014 cm-3 and that is of great interest for further development of high current ion sources for various applications.

13.
Rev Sci Instrum ; 87(9): 093301, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27782615

RESUMO

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O3+-O7+ were recorded at various tuner positions and frequencies in the range of 14.00-14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited "mode-hopping" between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

14.
Rev Sci Instrum ; 87(2): 02A701, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931919

RESUMO

The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz A-electron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10-100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime.

15.
Rev Sci Instrum ; 87(2): 02A703, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931921

RESUMO

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of ECRISs.

16.
Rev Sci Instrum ; 87(2): 02A715, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931933

RESUMO

A new type of ECR ion source-a gasdynamic ECR ion source-has been recently developed at the Institute of Applied Physics. The main advantages of such device are extremely high ion beam current with a current density up to 600-700 emA/cm(2) in combination with low emittance, i.e., normalized RMS emittance below 0.1 π mm mrad. Previous investigations were carried out in pulsed operation with 37.5 or 75 GHz gyrotron radiation with power up to 100 kW at SMIS 37 experimental facility. The present work demonstrates the first experience of operating the gasdynamic ECR ion source in CW mode. A test bench of SMIS 24 facility has been developed at IAP RAS. 24 GHz radiation of CW gyrotron was used for plasma heating in a magnetic trap with simple mirror configuration. Initial studies of plasma parameters were performed. Ion beams with pulsed and CW high voltage were successfully extracted from the CW discharge. Obtained experimental results demonstrate that all advantages of the gasdynamic source can be realized also in CW operation.

17.
Rev Sci Instrum ; 87(2): 02A716, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931934

RESUMO

The experimental and theoretical research carried out at the Institute of Applied Physics resulted in development of a new type of electron cyclotron resonance ion sources (ECRISs)-the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller's ECRIS confinement, i.e., the quasi-gasdynamic one similar to that in fusion mirror traps. Experimental studies of gasdynamic ECRIS were performed at Simple Mirror Ion Source (SMIS) 37 facility. The plasma was created by 37.5 and 75 GHz gyrotron radiation with power up to 100 kW. High frequency microwaves allowed to create and sustain plasma with significant density (up to 8 × 10(13) cm(-3)) and to maintain the main advantages of conventional ECRIS such as high ionization degree and low ion energy. Reaching such high plasma density relies on the fact that the critical density grows with the microwave frequency squared. High microwave power provided the average electron energy on a level of 50-300 eV enough for efficient ionization even at neutral gas pressure range of 10(-4)-10(-3) mbar. Gasdynamic ECRIS has demonstrated a good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z = 4-5 for argon). Gasdynamic ECRIS has appeared to be especially effective in low emittance hydrogen and deuterium beams formation. Proton beams with current up to 500 emA and RMS emittance below 0.07 π ⋅ mm ⋅ mrad have been demonstrated in recent experiments.

18.
Rev Sci Instrum ; 87(2): 02A729, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931947

RESUMO

It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. It was found that even in various gases (helium and oxygen were studied) and at different values of magnetic field and heating power, the dynamic spectra demonstrate common features: decreasing frequency within a single burst as well as from one burst to another.

19.
Appl Radiat Isot ; 106: 29-33, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26302662

RESUMO

BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beams with current density up to 700-800 mA/cm(2). Generation of the neutron flux with density at the level of 7-8·10(10) s(-1) cm(-2) at the target surface could be obtained in case of TiD2 target bombardment with deuteron beam accelerated to 100 keV. Estimations show that it is enough for formation of epithermal neutron flux with density higher than 10(9) s(-1) cm(-2) suitable for BNCT. Important advantage of described approach is absence of Tritium in the scheme. First experiments performed in pulsed regime with 300 mA, 45 kV deuteron beam directed to D2O target demonstrated 10(9) s(-1) neutron flux. This value corresponds to theoretical estimations and proofs prospects of neutron generator development based on high current quasi-gasdynamic ECR ion source.


Assuntos
Terapia por Captura de Nêutron de Boro , Nêutrons , Gases em Plasma
20.
Rev Sci Instrum ; 86(2): 023301, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25725830

RESUMO

Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space available for the optimization of high charge state ion currents. The most critical parameter in terms of plasma stability is the strength of the solenoid magnetic field. It is demonstrated that due to the instabilities the optimum Bmin-field in single frequency heating mode is often ≤0.8BECR, which is the value suggested by the semiempirical scaling laws guiding the design of modern ECRISs. It is argued that the effect can be attributed not only to the absolute magnitude of the magnetic field but also to the variation of the average magnetic field gradient on the resonance surface.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA