Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Radiol ; 90(3 Pt 1): 287-98, 2009 Mar.
Artigo em Francês | MEDLINE | ID: mdl-19421113

RESUMO

PURPOSE: To assess the accuracy and torerability of gadolinium-enhanced thoracic CTA using a 64 MDCT compared to a 16 MDCT. Because this study was started prior to the description of NSF, particular attention was paid to long-term follow-up of the patient population. MATERIALS AND METHODS: The study protocol was approved by the ethics committee of our institution and informed consent was obtained from all patients. Fourteen patients (Group 1) (9 males and 5 females; mean age: 64.3 years) with contraindication to the administration of iodinated contrast material underwent thoracic CTA (collimation: 32 x 2 x 0.6 mm; pitch: 1.2) with gadolinium administration (0.5 mml/ml) at 0.4 mmol/kg injected at 6 ml/sec with evaluation of clinical and biological tolerability of the gadolinium based contrast agent. Results from this patient population were compared to results from a population of 31 patients (21 males; 10 females; mean age: 63.2 years) (Group 2) imaged on a 16 MDCT. All patients were folloowed-up for a mean time of 22.6 months. RESULTS: Using a mean contrast volume (standard deviation) that was not significantly different (Group 1: 54.8+/-11 ml; Group 2: 53.4+/-6.9 ml) (p=0.94), patients in Group 1 underwent complete thoracic CTA whereas patients in Group 2 underwent CTA of only the middle third of the thoracic region. All CTA examinations were diagnostic for Group 1 and Group 2 patients; however, evaluation of subsegmental vessels was possible in a significantly larger proportion of patients in Group 1 (10/14; 72%) compared to Group 2 (6/31; 19%) (p=0.003). Mean attenuation values within pulmonary arterial branches were similar for Groups 1 and 2 (central arteries: 194.5+/-51.3 HU vs 180.6+/-53.8 HU; p=0.38) (lobar arteries: 208.5+/-52.5 HU vs 189.9+/-60.1 HU; p=0.33) (segmental arteries: 220.4+/-50.4 HU vs 201.5+/-54.7 HU; p=0.42). Transient alteration of renal function was recorded in one patient from Group 1 with severe pre-existing chronic renal failure. No change in renal function was observed for Group 2 patients. No case of NSF was reported in patients with pre-existing renal failure at the time of enrollment. CONCLUSION: The use of gadolinium-based contrast agent for thoracic CTA using a 64 MDCT provides diagnostic quality examinations in all patients with improved image quality compared to a 16 MDCT. No complication other than transient alteration of renal function was observed. Because the likelihood of developing NSF may vary with the type of gadolinium-based contrast agent used, the least toxic agent should be used.


Assuntos
Angiografia/métodos , Meios de Contraste , Gadolínio DTPA , Falência Renal Crônica/complicações , Dermopatia Fibrosante Nefrogênica , Radiografia Torácica , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/efeitos adversos , Interpretação Estatística de Dados , Estudos de Viabilidade , Feminino , Gadolínio DTPA/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA