Resultados 1 - 20 de 21
Filtrar
1.
Astrobiology ; 23(3): 295-307, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36625891

RESUMO

Motility is widely distributed across the tree of life and can be recognized by microscopy regardless of phylogenetic affiliation, biochemical composition, or mechanism. Microscopy has thus been proposed as a potential tool for detection of biosignatures for extraterrestrial life; however, traditional light microscopy is poorly suited for this purpose, as it requires sample preparation, involves fragile moving parts, and has a limited volume of view. In this study, we deployed a field-portable digital holographic microscope (DHM) to explore microbial motility in Badwater Spring, a saline spring in Death Valley National Park, and complemented DHM imaging with 16S rRNA gene amplicon sequencing and shotgun metagenomics. The DHM identified diverse morphologies and distinguished run-reverse-flick and run-reverse types of flagellar motility. PICRUSt2- and literature-based predictions based on 16S rRNA gene amplicons were used to predict motility genotypes/phenotypes for 36.0-60.1% of identified taxa, with the predicted motile taxa being dominated by members of Burkholderiaceae and Spirochaetota. A shotgun metagenome confirmed the abundance of genes encoding flagellar motility, and a Ralstonia metagenome-assembled genome encoded a full flagellar gene cluster. This study demonstrates the potential of DHM for planetary life detection, presents the first microbial census of Badwater Spring and brine pool, and confirms the abundance of mobile microbial taxa in an extreme environment.


Assuntos
Microscopia , Parques Recreativos , Filogenia , RNA Ribossômico 16S/genética , Metagenoma , Metagenômica/métodos , América do Norte
2.
Med Phys ; 49(4): e1-e49, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35032394

RESUMO

Modern fluoroscopes used for image guidance have become quite complex. Adding to this complexity are the many regulatory and accreditation requirements that must be fulfilled during acceptance testing of a new unit. Further, some of these acceptance tests have pass/fail criteria, whereas others do not, making acceptance testing a subjective and time-consuming task. The AAPM Task Group 272 Report spells out the details of tests that are required and gives visibility to some of the tests that while not yet required are recommended as good practice. The organization of the report begins with the most complicated fluoroscopes used in interventional radiology or cardiology and continues with general fluoroscopy and mobile C-arms. Finally, the appendices of the report provide useful information, an example report form and topics that needed their own section due to the level of detail.


Assuntos
Cardiologia , Radiologia Intervencionista , Fluoroscopia/métodos , Doses de Radiação , Radiologia Intervencionista/métodos , Relatório de Pesquisa
3.
J Appl Clin Med Phys ; 21(11): 205-214, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33142050

RESUMO

PURPOSE: We introduce an automated, quantitative image analysis package for gamma camera and single photon emission computed tomography quality control. Our focus was to produce consistent methods that are feasible in clinical settings and use standard phantoms. METHODS: Four gamma cameras were used to acquire planar images of four-quadrant bar phantoms and projection views of an American College of Radiology (ACR) phantom as part of a standard gamma camera quality control program. Images were sent to QC-Track® (Atirix Medical Systems, Inc., Minneapolis, MN, USA), which automatically placed predetermined regions of interest (ROIs) and performed analysis. For the bar phantom, a standard deviation (SD)-based modulation transfer function was calculated for a circular ROI in each quadrant. The bar widths at various MTF values were reported using linear interpolation as applicable. For the ACR phantom, the contrast-to-noise ratio (CNR) for each sphere, a modulation for each rods section, and a percent deviation for uniformity ROIs was calculated. Spheres corresponding to a CNR of 3, and the rod size at various modulations were also reported using linear interpolation. Visual analysis was performed by three medical physicists to evaluate interobserver variability and correlation to quantitative values. RESULTS: Analysis of the bar phantom showed predictable differences with changes in matrix size and bar width and showed consistency over similar acquisitions over the course of the study. Analysis of the ACR Phantom showed increasing CNR and modulation with increasing sphere and rod diameter, as expected. For both phantoms, quantitative values from linear interpolation correlated well with visual analysis. CONCLUSION: Our automated method for quantitative image analysis is consistent and shows increased precision and sensitivity when compared to standard visual methods. Thresholds correspond well with visual analysis and previous guidelines for observer visibility (e.g., Rose criterion), making our framework suitable for routine use in a nuclear medicine department.


Assuntos
Câmaras gama , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Variações Dependentes do Observador , Imagens de Fantasmas , Controle de Qualidade
4.
J Appl Clin Med Phys ; 20(10): 172-180, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31593338

RESUMO

Modern fluoroscopes pose a challenge for the clinical physicist for annual testing and continued upkeep. These fluoroscopes are critical to providing care to patients for complex interventions, and continue to evolve in automated image quality adjustments. Few tools in software or hardware currently exist to assist the physicist or technologist in gauging fluoroscope constancy or readiness for procedures. Many modalities such as mammography, computed tomography or even magnetic resonance imaging are much more evolved with respect to testing or quality control. In this work we sought to provide simple reproducible tools and methods for spot evaluating or continued quality testing of interventional fluoroscopes.


Assuntos
Fluoroscopia/métodos , Fluoroscopia/normas , Imagens de Fantasmas , Controle de Qualidade , Radiografia Intervencionista/métodos , Razão Sinal-Ruído , Humanos , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Estudos Retrospectivos , Software
5.
Pacing Clin Electrophysiol ; 40(6): 615-623, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28240419

RESUMO

BACKGROUND: The incidence of cardiac implantable electronic device (CIED) infections has risen significantly over the past years. Although several devices are currently available to decrease the incidence of infection, most are made from nonviable synthetic material and are more prone to infection than vascularized tissue. OBJECTIVE: This study was undertaken to assess the resistance to infection of the CorMatrix CanGaroo (CorMatrix Cardiovascular, Roswell, GA, USA), a CIED envelope made of decellularized extracellular matrix (ECM) hydrated in different antibiotic solutions. METHODS: This study was comprised of two in vitro tests and one animal trial. For all the tests, the ECM was hydrated in a mixture of vancomycin (25 mg/mL) and gentamicin (20 mg/mL) or gentamicin alone (40 mg/mL). The drug elution characteristics were assessed followed by the effectiveness of CanGaroo to prevent the bacterial growth of Staphylococcus aureus and Staphylococcus epidermidis in culture. Then, the direct inoculation of pacemaker implant pockets with both Staphylococcus species was performed in rabbits implanted with either a pacemaker alone or a pacemaker with antibiotic-soaked CorMatrix ECM pouches. RESULTS: The hydration of CanGaroo envelopes in both antibiotic mixtures resulted in antimicrobial activity against both Staphylococcus species, with an early bolus release of antibiotics followed by a slow release lasting for up to 6 days. In vivo, there was a substantial decrease in the occurrence of infection. CONCLUSIONS: The hydration of the CanGaroo ECM with an antibiotic solution prevented Staphylococcus species growth in vitro and substantially reduced the incidence of CIED pocket infections in an in vivo rabbit model.


Assuntos
Matriz Extracelular/transplante , Gentamicinas/administração & dosagem , Proteínas de Membrana/efeitos dos fármacos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Estafilocócicas/prevenção & controle , Vancomicina/administração & dosagem , Animais , Antibacterianos/administração & dosagem , Sistema Livre de Células/química , Terapia Combinada/métodos , Desfibriladores Implantáveis/efeitos adversos , Combinação de Medicamentos , Matriz Extracelular/química , Feminino , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Coelhos , Infecções Estafilocócicas/diagnóstico , Resultado do Tratamento
6.
Radiology ; 274(2): 540-7, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25247405

RESUMO

PURPOSE: To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. MATERIALS AND METHODS: Informed consent was obtained from all participants under one of two institutional review board-approved, HIPAA-compliant protocols. Twelve female patients (age range, 19-54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22-56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9-7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. RESULTS: Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. CONCLUSION: The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination.


Assuntos
Neoplasias da Mama/diagnóstico , Meios de Contraste , Análise de Fourier , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
7.
Magn Reson Med ; 73(2): 677-82, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24604286

RESUMO

PURPOSE: SWIFT (SWeep Imaging with Fourier Transformation) is a non-Cartesian MRI method with unique features and capabilities. In SWIFT, radiofrequency (RF) excitation and reception are performed nearly simultaneously, by rapidly switching between transmit and receive during a frequency-swept RF pulse. Because both the transmitted pulse and data acquisition are simultaneously amplitude-modulated in SWIFT (in contrast to continuous RF excitation and uninterrupted data acquisition in more familiar MRI sequences), crosstalk between different frequency bands occurs in the data. This crosstalk leads to a "bulls-eye" artifact in SWIFT images. We present a method to cancel this interband crosstalk by cycling the pulse and receive gap positions relative to the un-gapped pulse shape. We call this strategy "gap cycling." THEORY AND METHODS: We carry out theoretical analysis, simulation and experiments to characterize the signal chain, resulting artifacts, and their elimination for SWIFT. RESULTS: Theoretical analysis reveals the mechanism for gap-cycling's effectiveness in canceling interband crosstalk in the received data. We show phantom and in vivo results demonstrating bulls-eye artifact free images. CONCLUSION: Gap cycling is an effective method to remove bulls-eye artifact resulting from interband crosstalk in SWIFT data.


Assuntos
Algoritmos , Artefatos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Magn Reson Med ; 73(6): 2390-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24986525

RESUMO

PURPOSE: Ultra-high field (UHF) MR scanning in the body requires novel coil designs due to B1 field inhomogeneities. In the transverse electromagnetic field (TEM) design, maximum B1 transmit power can only be achieved if each individual transmit element is tuned and matched for different coil loads, which requires a considerable amount of valuable scanner time. METHODS: An integrated system for autotuning a multichannel parallel transmit (pTx) cardiac TEM array was devised, using piezoelectric actuators, power monitoring equipment and control software. The reproducibility and performance of the system were tested and the power responses of the coil elements were profiled. An automated optimization method was devised and evaluated. RESULTS: The time required to tune an eight-element pTx cardiac RF array was reduced from a mean of 30 min to less than 10 min with the use of this system. CONCLUSION: Piezoelectric actuators are an attractive means of tuning RF coil arrays to yield more efficient B1 transmission into the subject. An automated mechanism for tuning these elements provides a practical solution for cardiac imaging at UHF, bringing this technology closer to clinical use.


Assuntos
Coração/anatomia & histologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Algoritmos , Desenho de Equipamento , Voluntários Saudáveis , Humanos , Reprodutibilidade dos Testes
9.
Magn Reson Med ; 72(2): 304-15, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24006267

RESUMO

PURPOSE: Phosphorus magnetic resonance spectroscopy ((31)P-MRS) affords unique insight into cardiac energetics but has a low intrinsic signal-to-noise ratio (SNR) in humans. Theory predicts an increased (31)P-MRS SNR at 7T, offering exciting possibilities to better investigate cardiac metabolism. We therefore compare the performance of human cardiac (31)P-MRS at 7T to 3T, and measure T1s for (31)P metabolites at 7T. METHODS: Matched (31)P-MRS data were acquired at 3T and 7T, on nine normal volunteers. A novel Look-Locker CSI acquisition and fitting approach was used to measure T1s on six normal volunteers. RESULTS: T1s in the heart at 7T were: phosphocreatine (PCr) 3.05 ± 0.41s, γ-ATP 1.82 ± 0.09s, α-ATP 1.39 ± 0.09s, ß-ATP 1.02 ± 0.17s and 2,3-DPG (2,3-diphosphoglycerate) 3.05 ± 0.41s (N = 6). In the field comparison (N = 9), PCr SNR increased 2.8× at 7T relative to 3T, the Cramer-Ráo uncertainty (CRLB) in PCr concentration decreased 2.4×, the mean CRLB in PCr/ATP decreased 2.7× and the PCr/ATP SD decreased 2×. CONCLUSION: Cardiac (31)P-MRS at 7T has higher SNR and the spectra can be quantified more precisely than at 3T. Cardiac (31)P T1s are shorter at 7T than at 3T. We predict that 7T will become the field strength of choice for cardiac (31)P-MRS.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Miocárdio/metabolismo , Compostos de Fósforo/metabolismo , Adulto , Humanos , Masculino , Imagem Molecular/métodos , Isótopos de Fósforo/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Engenharia Tecidual , Adulto Jovem
10.
IEEE Trans Biomed Eng ; 61(2): 327-33, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23508243

RESUMO

Multi-element volume radio-frequency (RF) coils are an integral aspect of the growing field of high-field magnetic resonance imaging. In these systems, a popular volume coil of choice has become the transverse electromagnetic (TEM) transceiver coil consisting of microstrip resonators. In this paper, to further advance this design approach, a new microstrip resonator strategy in which the transmission line is segmented into alternating impedance sections, referred to as stepped impedance resonators (SIRs), is investigated. Single-element simulation results in free space and in a phantom at 7 T (298 MHz) demonstrate the rationale and feasibility of the SIR design strategy. Simulation and image results at 7 T in a phantom and human head illustrate the improvements in a transmit magnetic field, as well as RF efficiency (transmit magnetic field versus specific absorption rate) when two different SIR designs are incorporated in 8-element volume coil configurations and compared to a volume coil consisting of microstrip elements.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Impedância Elétrica , Campos Eletromagnéticos , Desenho de Equipamento , Cabeça/anatomia & histologia , Cabeça/fisiologia , Humanos , Imagens de Fantasmas
11.
Magn Reson Med ; 70(4): 1038-46, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23197329

RESUMO

At clinical MRI field strengths (1.5 and 3 T), quantitative maps of the longitudinal relaxation time T1 of the myocardium reveal diseased tissue without requiring contrast agents. Cardiac T1 maps can be measured by Look-Locker inversion recovery sequences such as ShMOLLI at 1.5 and 3 T. Cardiovascular MRI at a field strength of 7 T has recently become feasible, but doubts have remained as to whether magnetization inversion is possible in the heart due to subject heating and technical limitations. This work extends the repertoire of 7 T cardiovascular MRI by implementing an adiabatic inversion pulse optimized for use in the heart at 7 T. A "ShMOLLI+IE" adaptation of the ShMOLLI pulse sequence has been introduced together with new postprocessing that accounts for the possibility of incomplete magnetization inversion. These methods were validated in phantoms and then used in a study of six healthy volunteers to determine the degree of magnetization inversion and the T1 of normal myocardium at 7 T within a 22-heartbeat breathhold. Using a scanner with 16 × 1 kW radiofrequency outputs, inversion efficiencies ranging from -0.79 to -0.83 (intrasegment means; perfect 180° would give -1) were attainable across the myocardium. The myocardial T1 was 1925 ± 48 ms (mean ± standard deviation).


Assuntos
Algoritmos , Ventrículos do Coração/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Magn Reson Med ; 64(6): 1625-39, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20740657

RESUMO

Three different coil configurations were evaluated through simulation and experimentally to determine safe operating limits and evaluate subject size-dependent performance for prostate imaging at 7 T. The coils included a transceiver endorectal coil (trERC), a 16-channel transceiver external surface array (trESA) and a trESA combined with a receive-only ERC (trESA+roERC). Although the transmit B(1) (B 1+) homogeneity was far superior for the trESA, the maximum achievable B 1+ is subject size dependent and limited by transmit chain losses and amplifier performance. For the trERC, limitations in transmit homogeneity greatly compromised image quality and limited coverage of the prostate. Despite these challenges, the high peak B 1+ close to the trERC and subject size-independent performance provides potential advantages especially for spectroscopic localization where high-bandwidth radiofrequency pulses are required. On the receive side, the combined trESA+roERC provided the highest signal-to-noise ratio and improved homogeneity over the trERC resulting in better visualization of the prostate and surrounding anatomy. In addition, the parallel imaging performance of the trESA+roERC holds strong promise for diffusion-weighted imaging and dynamic contrast-enhanced MRI.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Próstata/anatomia & histologia , Adulto , Desenho de Equipamento , Humanos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Masculino , Imagens de Fantasmas , Reto
13.
Magn Reson Med ; 63(6): 1478-85, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20512850

RESUMO

Transmit and receive RF coil arrays have proven to be particularly beneficial for ultra-high-field MR. Transmit coil arrays enable such techniques as B(1) (+) shimming to substantially improve transmit B(1) homogeneity compared to conventional volume coil designs, and receive coil arrays offer enhanced parallel imaging performance and SNR. Concentric coil arrangements hold promise for developing transceiver arrays incorporating large numbers of coil elements. At magnetic field strengths of 7 tesla and higher where the Larmor frequencies of interest can exceed 300 MHz, the coil array design must also overcome the problem of the coil conductor length approaching the RF wavelength. In this study, a novel concentric arrangement of resonance elements built from capacitively-shortened half-wavelength transmission lines is presented. This approach was utilized to construct an array with whole-brain coverage using 16 transceiver elements and 16 receive-only elements, resulting in a coil with a total of 16 transmit and 32 receive channels.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/classificação , Imageamento por Ressonância Magnética/instrumentação
14.
Magn Reson Med ; 61(1): 244-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19097214

RESUMO

The objective of this study was to investigate the feasibility of whole-body imaging at 7T. To achieve this objective, new technology and methods were developed. Radio frequency (RF) field distribution and specific absorption rate (SAR) were first explored through numerical modeling. A body coil was then designed and built. Multichannel transmit and receive coils were also developed and implemented. With this new technology in hand, an imaging survey of the "landscape" of the human body at 7T was conducted. Cardiac imaging at 7T appeared to be possible. The potential for breast imaging and spectroscopy was demonstrated. Preliminary results of the first human body imaging at 7T suggest both promise and directions for further development.


Assuntos
Algoritmos , Mama/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Corporal Total/métodos , Estudos de Viabilidade , Feminino , Humanos , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Magn Reson Med ; 59(4): 936-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18383292

RESUMO

This work investigates probe construction materials for their signal contribution to ultrashort echo time spectroscopy and imaging. (1)H, (13)C, and (31)P spectra were obtained at a field strength of 9.4 T for 16 materials considered for use in probe and holder design and construction. Four of the materials were found to be suited for the construction of NMR probes, housing of RF coils, and holders for in vivo experiments.


Assuntos
Espectroscopia de Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Manejo de Espécimes/instrumentação , Transdutores , Espectroscopia de Ressonância Magnética/métodos , Teste de Materiais , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/métodos
16.
Magn Reson Med ; 59(3): 590-7, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18219635

RESUMO

A novel geometrically adjustable transceiver array system is presented. A key feature of the geometrically adjustable array was the introduction of decoupling capacitors that allow for automatic change in capacitance dependent on neighboring resonant element distance. The 16-element head array version of such an adjustable coil based on transmission line technology was compared to fixed geometry transmission line arrays (TLAs) of various sizes at 7T. The focus of this comparison was on parallel imaging performance, RF transmit efficiency, and signal-to-noise ratio (SNR). Significant gains in parallel imaging performance and SNR were observed for the new coil and attributed to its adjustability and to the design of the individual elements with a three-sided ground plane.


Assuntos
Mapeamento Encefálico/métodos , Aumento da Imagem/instrumentação , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Desenho de Equipamento , Humanos , Processamento de Sinais Assistido por Computador
17.
Magn Reson Med ; 59(2): 396-409, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18228604

RESUMO

High-quality prostate images were obtained with transceiver arrays at 7T after performing subject-dependent local transmit B(1) (B(1) (+)) shimming to minimize B(1) (+) losses resulting from destructive interferences. B(1) (+) shimming was performed by altering the input phase of individual RF channels based on relative B(1) (+) phase maps rapidly obtained in vivo for each channel of an eight-element stripline coil. The relative transmit phases needed to maximize B(1) (+) coherence within a limited region around the prostate greatly differed from those dictated by coil geometry and were highly subject-dependent. A set of transmit phases determined by B(1) (+) shimming provided a gain in transmit efficiency of 4.2 +/- 2.7 in the prostate when compared to the standard transmit phases determined by coil geometry. This increased efficiency resulted in large reductions in required RF power for a given flip angle in the prostate which, when accounted for in modeling studies, resulted in significant reductions of local specific absorption rates. Additionally, B(1) (+) shimming decreased B(1) (+) nonuniformity within the prostate from (24 +/- 9%) to (5 +/- 4%). This study demonstrates the tremendous impact of fast local B(1) (+) phase shimming on ultrahigh magnetic field body imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Próstata/anatomia & histologia , Adulto , Desenho de Equipamento , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Masculino
18.
Magn Reson Med ; 59(1): 73-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17969077

RESUMO

In vivo temperatures were correlated to the whole head average specific absorption rate (SAR(avg)) at 9.4T using 12 anesthetized swine (mean animal weight = 52 kg, standard deviation = 6.7 kg). Correlating the temperatures and SAR(avg) is necessary to ensure safe levels of human heating during ultra-high field MR exams. The temperatures were measured at three depths inside the brain, in the rectum, and at the head-skin of swine. A 400 MHz, continuous wave RF power was deposited to the head using a volume coil. The SAR(avg) values were varied between 2.7-5.8 W/kg. The RF power exposure durations were varied between 1.4-3.7 hr. To differentiate the temperature response caused by the RF from that of the anesthesia, the temperatures were recorded in four unheated swine. To study the effect of the spatial distribution of the RF and tissue properties, the temperature probes were placed at two brain locations (n = 4 swine for each location). Results showed that the in vivo brain temperatures correlated to the SAR(avg) in a geometry-dependent manner. Additionally, 1) the skin temperature change was not the maximum temperature change; 2) the RF heating caused an inhomogeneous brain temperature distribution; and 3) the maximum temperature occurred inside the brain.


Assuntos
Temperatura Alta , Imageamento por Ressonância Magnética/instrumentação , Animais , Temperatura Corporal , Encéfalo , Cabeça , Ondas de Rádio , Suínos
19.
Magn Reson Med ; 56(6): 1274-82, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17075852

RESUMO

This work reports the preliminary results of the first human images at the new high-field benchmark of 9.4T. A 65-cm-diameter bore magnet was used together with an asymmetric 40-cm-diameter head gradient and shim set. A multichannel transmission line (transverse electromagnetic (TEM)) head coil was driven by a programmable parallel transceiver to control the relative phase and magnitude of each channel independently. These new RF field control methods facilitated compensation for RF artifacts attributed to destructive interference patterns, in order to achieve homogeneous 9.4T head images or localize anatomic targets. Prior to FDA investigational device exemptions (IDEs) and internal review board (IRB)-approved human studies, preliminary RF safety studies were performed on porcine models. These data are reported together with exit interview results from the first 44 human volunteers. Although several points for improvement are discussed, the preliminary results demonstrate the feasibility of safe and successful human imaging at 9.4T.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Proteção Radiológica/instrumentação , Transdutores , Queimaduras por Corrente Elétrica/etiologia , Queimaduras por Corrente Elétrica/prevenção & controle , Tontura/etiologia , Tontura/prevenção & controle , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Projetos Piloto , Proteção Radiológica/métodos , Medição de Risco
20.
Magn Reson Med ; 53(2): 434-45, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15678527

RESUMO

Transceive array coils, capable of RF transmission and independent signal reception, were developed for parallel, 1H imaging applications in the human head at 7 T (300 MHz). The coils combine the advantages of high-frequency properties of transmission lines with classic MR coil design. Because of the short wavelength at the 1H frequency at 300 MHz, these coils were straightforward to build and decouple. The sensitivity profiles of individual coils were highly asymmetric, as expected at this high frequency; however, the summed images from all coils were relatively uniform over the whole brain. Data were obtained with four- and eight-channel transceive arrays built using a loop configuration and compared to arrays built from straight stripline transmission lines. With both the four- and the eight-channel arrays, parallel imaging with sensitivity encoding with high reduction numbers was feasible at 7 T in the human head. A one-dimensional reduction factor of 4 was robustly achieved with an average g value of 1.25 with the eight-channel transmit/receive coils.


Assuntos
Mapeamento Encefálico/instrumentação , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Transdutores , Mapeamento Encefálico/métodos , Desenho de Equipamento , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade