Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Intern Med ; 63(6): 803-807, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37495529

RESUMO

A 55-year-old patient was admitted for variceal treatment, a complication of chronic portal hypertension and liver cirrhosis. Imaging studies revealed prominent duodenal varices, the pancreaticoduodenal vein as its afferent pathway, a drainer vessel into the inferior vena cava, and a paraumbilical vein. We successfully performed complete obliteration of the varix, including its afferent and efferent vessels, via the paraumbilical vein approach.


Assuntos
Duodeno/anormalidades , Embolização Terapêutica , Varizes Esofágicas e Gástricas , Doenças Fetais , Bexiga Urinária/anormalidades , Varizes , Humanos , Pessoa de Meia-Idade , Escleroterapia , Varizes/complicações , Varizes/terapia , Embolização Terapêutica/métodos , Varizes Esofágicas e Gástricas/complicações , Hemorragia Gastrointestinal/etiologia
2.
Liver Cancer ; 12(6): 576-589, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38058422

RESUMO

Introduction: The purpose of this study was to evaluate the treatment efficacy of transcatheter arterial chemoembolization (TACE) for treatment-naive hepatocellular carcinoma (HCC) according to tumor location and burden. Methods: Between 2010 and 2019, consecutive patients who underwent TACE as the first treatment were enrolled. Tumors were classified into two categories based on their location, as central or peripheral tumors. Tumors in the central zone, which is within 1 cm of the main trunk or the first branch of the portal vein, were classified as central tumors, while those located in the peripheral zone were classified as peripheral tumors. Patients were grouped according to the HCC location and up-to-7 criteria. Patients with central tumors were classified into the central arm and those with only peripheral tumors were classified into the peripheral arm. Patients within and beyond the up-to-7 criteria were classified into the up-to-7 in and up-to-7 out-groups, respectively. Local recurrence-free survival (LRFS) and progression-free survival (PFS) were compared per nodule (central tumor vs. peripheral tumor) and per patient (central arm vs. peripheral arm), respectively. The prognostic factors of LRFS and PFS were analyzed by univariate and multivariate analyses. Results: A total of 174 treatment-naive patients with 352 HCCs were retrospectively enrolled. Ninety-six patients and 130 lesions were selected by propensity score matching. Median LRFS was longer for peripheral tumors than central tumors (not reached vs. 3.3 months, p < 0.001). Median PFS was 17.1 months (8.3-24.9) in the peripheral arm and up-to-7 in, 7.0 months (3.3-12.7) in the peripheral arm and up-to-7 out, 8.4 months (4.0-12.6) in the central arm and up-to-7 in, and 3.0 months (1.2-4.9) in the central arm and up-to-7 out-groups. The peripheral arm and up-to-7 in-groups had significantly longer PFS than the other three groups (p = 0.013, p = 0.015, p < 0.001, respectively). Multivariate analysis confirmed that the central zone and central arm were associated with high adjusted hazard ratios for tumor recurrence or death (2.87, p < 0.001; 2.89, p < 0.001, respectively). Conclusion: Treatment-naive HCCs in the peripheral zone had a longer LRFS and PFS following TACE compared to those in the central zone.

3.
Radiol Case Rep ; 18(12): 4327-4330, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37789920

RESUMO

The standard treatment for ruptured duodenal varices remains to be established. Emergency balloon-occluded retrograde transvenous obliteration is challenging in patients with bleeding because re-rupture of varices can occur due to increased pressure when using the retrograde approach. Herein, we describe a case in which a catheter was retrogradely advanced to the afferent vein beyond bleeding duodenal varices; however, the varices re-ruptured during coil embolization, and a part of the catheter was deviated into the intestinal tract. The rupture site was embolized by liquid embolic materials from the microcatheter. Embolization via retrograde approach needs to be carefully performed.

4.
Radiol Case Rep ; 18(9): 3037-3040, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37434611

RESUMO

Recently, combination therapy with atezolizumab, a humanized monoclonal antiprogrammed death ligand-1 antibody, and bevacizumab, has become available for treatment of unresectable hepatocellular carcinoma (HCC). We herein report a 73-year-old man with advanced stage HCC who developed fatigue during treatment with atezolizumab-bevacizumab combination therapy. Computed tomography identified intratumoral hemorrhage within the HCC metastasis to the right fifth rib metastasis of HCC, which was confirmed on emergency angiography of the right 4th and 5th intercostal arteries and some branches of the subclavian artery confirmed intratumoral hemorrhage, following which transcatheter arterial embolization (TAE) was performed to achieve hemostasis. He continued to receive atezolizumab-bevacizumab combination therapy after TAE, and no rebleeding was seen. Although uncommon, rupture and intratumoral hemorrhage in the HCC metastasis to the ribs can cause life-threatening hemothorax. However, to our knowledge, no previous cases of intratumoral hemorrhage in HCC during atezolizumab-bevacizumab combination therapy have been reported. This is the first report of intratumoral hemorrhage with the combination therapy of atezolizumab and bevacizumab, which was successfully controlled by TAE. Patients receiving this combination therapy should be observed for intratumoral hemorrhage, which can be managed by TAE if it does occur.

5.
PLoS One ; 18(2): e0281384, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36735744

RESUMO

OBJECTIVES: Tract embolization has been performed to prevent bleeding after trans-organ puncture. This study evaluated clinical outcomes of tract embolization using a gel-like radiopaque material comprising two sheets of gelatin sponge and 3 mL of contrast agent, and experimentally confirmed its viscosity and hemostatic efficacy. METHODS: Three study phases were planned. In a clinical setting, 57 consecutive patients who underwent tract embolization after transhepatic puncture were retrospectively analyzed. Clinical success was evaluated as absence of bleeding complications for 30 days after the procedure. In a basic experiment, viscosity of the material was analyzed. In an animal experiment, rabbit kidney puncture site was embolized via a 7-Fr sheath using this material, coils, or N-butyl-2-cyanoacrylate glue or received no embolization while removing the sheath. Amounts of tract bleeding were measured for 1 min and compared between groups. RESULTS: Embolization was successfully completed in all clinical cases. No postoperative bleeding requiring intervention was encountered. The basic experiment revealed the material was highly viscous. In the animal experiment, mean weights of bleeding in the control, gel-like embolic material, coil, and N-butyl-2-cyanoacrylate glue groups were 1.04±0.32 g, 0.080±0.056 g, 0.20±0.17 g and 0.11±0.10 g, respectively. No significant differences were seen among embolization groups, while the control group showed significantly more bleeding than any embolization group. CONCLUSION: Tract embolization with this gel-like radiopaque embolic material appears safe and feasible. ADVANCES IN KNOWLEDGE: Tract embolization using this embolic material with two sheets of gelatin sponge and 3 mL of contrast agent offers a safe, feasible, and economical procedure after trans-organ puncture, because the material offers the following characteristics: visibility under X-ray; viscosity facilitating retention in the tract; ability to allow repeated puncture via the same route; and low cost.


Assuntos
Embolização Terapêutica , Embucrilato , Animais , Coelhos , Meios de Contraste , Gelatina/uso terapêutico , Embucrilato/uso terapêutico , Estudos Retrospectivos , Estudos de Viabilidade , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Hemorragia Pós-Operatória/tratamento farmacológico , Resultado do Tratamento
6.
Hepatol Res ; 53(3): 228-237, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36356950

RESUMO

AIM: Patients with liver cirrhosis and portosystemic shunt occasionally develop reversed portal flow in the portal venous system. The factors contributing to reversed portal flow in these patients remain unclear. The aim of this study was to identify factors contributing to reversed portal flow in patients with portosystemic shunts based on four-dimensional computed tomography (4DCT), which visualized flow dynamics in the portal venous system. METHODS: Data from 34 consecutive patients with portosystemic shunts who had undergone 4DCT before interventional radiology procedures were retrospectively investigated in this study. Uni- and multivariate analyses were performed to identify factors contributing to reversed portal flow. RESULTS: Flow dynamics could be visualized on 4DCT in 32 of the 34 patients. Fifteen patients had forward portal flow; 17 had reversed portal flow. The main portal, splenic, and superior mesenteric veins displayed reversed portal flow in five, 12, and five vessels, respectively. Portosystemic shunt originating from splenic and superior mesenteric veins, worse albumin-bilirubin score, and small main portal vein diameter were significant factors contributing to reversed portal flow in both univariate (p = 0.049, p = 0.027, and p = 0.002) and multivariate (odds ratio [OR] 6.345, p = 0.012; OR 4.279, p = 0.039; and OR 5.516, p = 0.019) analyses. CONCLUSIONS: The reversed portal flow was visualized on 4DCT. Portosystemic shunt originating distant to the liver, worse albumin-bilirubin score, and small diameter of the main portal vein were factors contributing to reversed flow in the portal venous system.

7.
J Vasc Surg ; 77(1): 114-121.e2, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35985566

RESUMO

OBJECTIVE: The objective of this study was to investigate the mid-term outcomes of embolization procedures for type II endoleak after endovascular abdominal aortic repair, and clarify the risk factors for aneurysm enlargement after embolization procedures. METHODS: This was a retrospective multicenter registry study enrolling patients who underwent embolization procedures for type II endoleaks after EVAR from January 2012 to December 2018 at 19 Japanese centers. The primary end point was the rate of freedom from aneurysm enlargement, more than 5 mm in the aortic maximum diameter, after an embolization procedure. Demographic, procedural, follow-up, and laboratory data were collected. Continuous variables were summarized descriptively, and Kaplan-Meier analyses and a Cox regression model were used for statistical analyses. RESULTS: A total of 315 patients (248 men and 67 women) were enrolled. The average duration from the initial embolization procedure to the last follow-up was 31.6 ± 24.6 months. The rates of freedom from aneurysm enlargement at 3 and 5 years were 55.4 ± 3.8% and 37.0 ± 5.2%, respectively. A multivariate analysis revealed that a larger aortic diameter at the initial embolization procedure and the presence of a Moyamoya endoleak, defined as heterogeneous contrast opacity with an indistinct faint border, were associated with aneurysm enlargement after embolization management. CONCLUSIONS: The embolization procedures were generally ineffective in preventing further expansion of abdominal aortic aneurysms in patients with type II endoleaks after EVAR, especially in patients with a large abdominal aortic aneurysm and/or a presence of a Moyamoya endoleak.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Masculino , Humanos , Feminino , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/terapia , Resultado do Tratamento , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Fatores de Risco , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Estudos Retrospectivos
8.
Acad Radiol ; 30(1): 30-39, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35680546

RESUMO

RATIONALE AND OBJECTIVES: Safety and feasibility of contrast-enhanced computed tomography (CECT) with a nanoparticulate contrast agent, ExiTron nano 12000, was evaluated in a rat liver tumor model. MATERIALS AND METHODS: This study employed eighteen 8-week-old male F344 rats. Six rats given tap water for 8 weeks further divided into two: Control group and Normal Liver with CECT group. Six rats each were given tap water containing diethylnitrosamine (DEN) at 100 ppm for 8 or 14 weeks; Adenoma group and Hepatocellular carcinoma (HCC) group, respectively. Biochemical marker values and adverse events were evaluated after CT imaging. ExiTron nano 12000 was evaluated for the hepatic contrast enhancement, and the detection and measurement of liver nodules by CECT after 8- and 14-weeks administration of DEN. Post-mortem liver specimens were evaluated by hematoxylin-eosin (HE) staining, and the number and size of liver nodules were measured. The HCC group was evaluated for diagnostic concordance between HE-stained and CECT-detected nodules. RESULTS: The contrast agent enhanced liver and was tolerated after CECT in 15 rats. Biochemical parameter values did not differ significantly between the Control and Normal Liver groups. The numbers of CECT-detected nodules in the Adenoma and HCC groups were 14.8 ± 5.1, and 32.4 ± 8.1, respectively. The HCC group had 3.6 ± 2.7 of pathological HCCs, which were identified by CECT. The size of CECT-detected HCCs correlated significantly with that of pathological HCCs (r = 0.966, p < 0.0001). CONCLUSION: CECT with ExiTron nano 12000 is a safe and feasible method to measure tumors in a rat liver tumor model.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Nanopartículas , Masculino , Ratos , Animais , Neoplasias Hepáticas/induzido quimicamente , Neoplasias Hepáticas/diagnóstico por imagem , Carcinoma Hepatocelular/induzido quimicamente , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Dietilnitrosamina/toxicidade , Estudos de Viabilidade , Ratos Endogâmicos F344 , Tomografia Computadorizada por Raios X , Água/efeitos adversos
9.
Radiol Case Rep ; 18(1): 200-204, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36340230

RESUMO

A 70-year-old woman with liver cirrhosis was admitted to our hospital for treatment of growing gastric varices in the fundus. Computed tomography showed gastric varices continuously draining the pericardiophrenic vein via the inferior phrenic vein. Balloon-occluded retrograde transvenous obliteration by a transjugular approach was planned. However, a conventional balloon catheter or microballoon catheter could not be inserted into the efferent vein near the varices because of the narrowness and tortuosity of the vein. Hence, coil-assisted retrograde transvenous obliteration was performed by an inverted catheter tip technique using a single conventional microcatheter. This technique might be useful for cases in which it is difficult to insert a balloon catheter into the efferent vein.

10.
Radiol Case Rep ; 17(12): 4679-4684, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36204409

RESUMO

A 74-year-old patient presented with hematochezia and a history of liver cirrhosis with repeated bleeding from esophageal and rectal varices. Endoscopic examination revealed multiple rectal varices with positive red color signs. Ascites, severe portosystemic thrombosis and a splenorenal shunt were diagnosed on a contrast-enhanced dynamic computed tomography examination. From a transjugular approach, we circumvented thrombosed regions by maneuvering double balloon catheters through the shunt and dilated left colic marginal vein. We managed to successfully obliterate the varices.

11.
J Endovasc Ther ; : 15266028221109477, 2022 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-35815459

RESUMO

PURPOSE: To evaluate the clinical utility of the Gore Excluder iliac branch endoprosthesis (IBE) for Japanese patients with aortoiliac aneurysms. MATERIALS AND METHODS: This was a multicenter retrospective cohort study (J-Preserve Registry). Patients undergoing endovascular aortic repair using the Gore Excluder IBE for aortoiliac aneurysms between August 2017 and June 2020 were enrolled. Data pertaining to the baseline and anatomical characteristics, technical details, and clinical outcomes were collected from each institution. The primary endpoints were technical success, IBE-related complications, and reinterventions. Secondary endpoints were mortality, aneurysm size change, and reintervention during follow-up. Technical success was defined as accurate deployment of the IBE without type Ib, Ic, or III endoleaks on the IBE sides on completion angiography. A change in aneurysm size of 5 mm or more was taken to be a significant change. RESULTS: We included 141 patients with 151 IBE implantations. Sixty-five IBE implantations (43.0%) had at least one instruction for use violation. Twenty-two patients (15.6%) required internal iliac artery (IIA) embolization for external iliac artery extension on the contralateral side. Of 151 IBE implantations, 19 exhibited IIA branch landing zones due to IIA aneurysms. Mean maximum and proximal common iliac artery (CIA) diameters were 32.9±9.9 mm and 20.5±6.9 mm, respectively. The mean CIA length was 59.1±17.1 mm. The IIA landing diameter and length were 9.0±2.3 mm and 33.8±14.6 mm. The overall technical success rate was 96.7%. There were no significant differences in IBE-related complications (2.3% vs 5.3%, p=0.86) or IBE-related reinterventions (1.5% vs 5.3%, p=0.33) between the IIA trunk and IIA branch landing groups. The mean follow-up period was 635±341 days. The all-cause mortality rate was 5.0%. There were no aneurysm-related deaths or ruptures during the follow-up. Most patients (95.7%) had sac stability or shrinkage. CONCLUSION: The Gore Excluder IBE was safe and effective for Japanese patients in the midterm. Extending the IIA device into the distal branches of the IIA was acceptable, which may permit extending indications for endovascular aortic aneurysm repair of aortoiliac aneurysms to more complex lesions. CLINICAL IMPACT: This study suggests clinical benefits of the Gore Excluder IBE for Japanese patients, despite 43% of the IBE implantations having at least one IFU violation.

12.
J Vasc Interv Radiol ; 33(7): 845-851.e8, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35311665

RESUMO

PURPOSE: To develop a deep learning (DL) model to generate synthetic, 2-dimensional subtraction angiograms free of artifacts from native abdominal angiograms. MATERIALS AND METHODS: In this retrospective study, 2-dimensional digital subtraction angiography (2D-DSA) images and native angiograms were consecutively collected from July 2019 to March 2020. Images were divided into motion-free (training, validation, and motion-free test datasets) and motion-artifact (motion-artifact test dataset) sets. A total of 3,185, 393, 383, and 345 images from 87 patients (mean age, 71 years ± 10; 64 men and 23 women) were included in the training, validation, motion-free, and motion-artifact test datasets, respectively. Native angiograms and 2D-DSA image pairs were used to train and validate an image-to-image translation model to generate synthetic DL-based subtraction angiography (DLSA) images. DLSA images were quantitatively evaluated by the peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) using the motion-free dataset and were qualitatively evaluated via visual assessments by radiologists with a numerical rating scale using the motion-artifact dataset. RESULTS: The DLSA images showed a mean PSNR (± standard deviation) of 43.05 dB ± 3.65 and mean SSIM of 0.98 ± 0.01, indicating high agreement with the original 2D-DSA images in the motion-free dataset. Qualitative visual evaluation by radiologists of the motion-artifact dataset showed that DLSA images contained fewer motion artifacts than 2D-DSA images. Additionally, DLSA images scored similar to or higher than 2D-DSA images for vascular visualization and clinical usefulness. CONCLUSIONS: The developed DL model generated synthetic, motion-free subtraction images from abdominal angiograms with similar imaging characteristics to 2D-DSA images.


Assuntos
Aprendizado Profundo , Idoso , Angiografia Digital/métodos , Artefatos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído
13.
Intern Med ; 61(7): 959-967, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34544949

RESUMO

Objective Mapping the long-term prognosis of Budd-Chiari syndrome (BCS) is difficult, as the prognosis is associated with changes in the liver function. The present study evaluated the time course changes in the liver function in a treatment group with percutaneous old balloon angioplasty (POBA) and a non-treatment group using the albumin-bilirubin score (ALBI) and Child-Pugh score during long-term follow-up. Methods In this retrospective study, 13 consecutive patients diagnosed with BCS at our hospital between 2007 and 2020 were categorized into a treatment group (n=8), which received POBA, and a non-treatment group (n=5). Differences in the liver function in the ALBI and Child-Pugh scores between the initial visit and one- and three-year follow-up were calculated and statistically evaluated. We investigated the changes in the liver function during the long-term follow-up, including events such as re-stenosis and re-treatment. Results While the Child-Pugh scores in the treatment group did not differ significantly between the initial visit and 1- or 3-year follow-up, the ALBI scores in this group improved significantly between the initial visit and the 1- or 3-year follow-up visit (p=0.0078 and 0.0156, respectively). The liver function according to the ALBI score in the treatment group showed gradual improvement from the initial value but gradual worsening in the non-treatment group. The ALBI scores also revealed that the liver function varies according to re-stenosis and re-POBA in BCS patients. Conclusion Unlike the Child-Pugh score, the ALBI score was able to capture changes in the liver function of BCS patients during the long-term course of BCS.


Assuntos
Síndrome de Budd-Chiari , Neoplasias Hepáticas , Albuminas , Bilirrubina , Síndrome de Budd-Chiari/terapia , Humanos , Neoplasias Hepáticas/cirurgia , Prognóstico , Estudos Retrospectivos
15.
Case Rep Radiol ; 2021: 7970894, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34426775

RESUMO

Uterine artery embolization (UAE) is a type of noninvasive treatment for symptomatic uterine fibroids. One of the complications of UAE is fibroid expulsion. Here, we report a case of a 45-year-old woman who underwent UAE for an intramural fibroid, which resulted in fibroid expulsion. To the best of our knowledge, there are only few reports of expulsion of intramural fibroids. The process of fibroid protrusion from the myometrium into the uterine cavity was depicted on magnetic resonance imaging (MRI) in this case. We discuss the risk factors and mechanisms of fibroid expulsion after UAE.

16.
Ann Vasc Dis ; 14(2): 192-197, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34239650

RESUMO

In this study, we report the case of a 47-year-old female who presented with extensive acute type IIIb aortic dissection and cerebral infarction. At 69 years of age, dilatation of the descending aorta was noted to be more than 70 mm with compression of the left atrium. We performed endovascular repair with distal false lumen occlusion. However, further dilatation of the descending aorta with false lumen flow from the re-entry of the common carotid artery was detected. She subsequently underwent additional proximal false lumen occlusion by embolization at the aortic arch. A year later, as per her computed tomography angiography findings, appreciable shrinkage of the descending aorta without endoleakage was observed.

17.
Radiol Case Rep ; 16(4): 801-806, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33552329

RESUMO

Stomal varices are rare and ectopic varices defined as dilated portosystemic collateral veins located in sites other than the gastro-esophageal region. These sometimes cause recurrent bleedings and can be life-threatening. Optimal treatments have yet to be established. We report 3 cases of repetitive bleeding stomal varices in which resolution of bleeding was obtained over the medium term with minimally invasive approaches including balloon-occluded retrograde transvenous obliteration and variceal embolization by ultrasound-guided direct puncture. Rebleeding did not occur in any patients within 2-15 months of follow-up. Serious complications over Clavien-Dindo grade I were not found.

18.
Cardiovasc Intervent Radiol ; 44(6): 921-930, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33474605

RESUMO

PURPOSE: Portal venous system thrombosis is a complication of partial splenic artery embolization, and pre-treatment risk assessment is thus important. The purpose of this study was to identify the risk factors for portal venous system thrombosis after partial splenic artery embolization. MATERIALS AND METHODS: We retrospectively analyzed 67 consecutive patients who underwent contrast-enhanced computed tomography before and after first partial splenic artery embolization between July 2007 and October 2018. As risk factors, we investigated age, sex, hematological data, liver function, steroid use, heparin use, and findings from pre- and post-treatment computed tomography. Uni- and multivariate analyses were performed to evaluate the relationship between thrombus appearance or growth and these factors. Values of p < 0.05 were considered significant. RESULTS: Partial splenic artery embolization was technically successful in all 67 patients. Nine patients showed appearance or growth of thrombus. Univariate analysis showed maximum diameter of the splenic vein before treatment (p = 0.0076), percentage of infarcted spleen (p = 0.017), and volume of infarcted spleen (p = 0.022) as significant risk factors. Multivariate analysis showed significant differences in maximum diameter of the splenic vein before treatment (p = 0.041) and percentage of infarcted spleen (p = 0.023). According to receiver operating characteristic analysis, cutoffs for maximum diameter of the splenic vein and percentage of infarcted spleen for distinguishing the appearance or growth of thrombus were 17 mm and 58.2%. CONCLUSION: Large maximum diameter of the splenic vein before partial splenic artery embolization and high percentage of infarcted spleen after partial splenic artery embolization were identified as risk factors for portal venous system thrombosis. LEVEL OF EVIDENCE: Level 4, Case Series.


Assuntos
Embolização Terapêutica/efeitos adversos , Veia Porta/fisiopatologia , Artéria Esplênica/fisiopatologia , Veia Esplênica/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Trombose Venosa/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Embolização Terapêutica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Trombose Venosa/fisiopatologia , Adulto Jovem
19.
Eur Radiol Exp ; 5(1): 1, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33432529

RESUMO

Multidetector row computed tomography (CT) scanners perform dynamic scanning and have a wide scan range. Time-resolved three-dimensional CT (i.e., 4D CT) has recently enabled visualization of flow in neurovascular vessels. We hypothesized that 4D CT technology would be a useful and non-invasive method for visualizing the flow dynamics of the portal circulation. The aim of this study was to evaluate the technical feasibility of 4D CT for visualizing flow dynamics in the portal circulation using 320-detector-row CT. 4D CT images of 18 consecutive patients with portal circulation including gastrorenal shunt were retrospectively evaluated for their ability to generate flow dynamics of the portal circulation. Flow dynamics could be visualized by 4D CT in 68 of the 72 vessels in the portal vein, splenic vein, superior mesenteric vein, and gastrorenal shunt. Flow direction could not be identified in four vessels, all of them being superior mesenteric veins. Flow direction was recognized on 4D CT in the 68 vessels of the portal circulation. A preliminary validation study revealed that flow direction of all 19 vessels in the portal circulation had concordance between 4D CT and color Doppler ultrasound. 4D CT could visualize flow dynamics of the portal circulation.


Assuntos
Veia Porta , Veia Esplênica , Estudos de Viabilidade , Humanos , Veia Porta/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
20.
BJR Case Rep ; 7(4): 20200097, 2021 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35047188

RESUMO

Ductus arteriosus aneurysm (DAA) in adulthood is a rare entity. We retrospectively reviewed our medical records from the past 10 years and identified 8 cases of adult DAA (6 males and 2 females aged between 69 and 89 years; mean, 76 years), using multiplanar reconstruction and three-dimensional reconstruction CT images. The aneurysm was suspected incidentally in all cases based on the results of chest radiographic screening or post-operative follow-up CT for lung or colon cancer. All eight patients were asymptomatic but had a history of or concurrent hypertension (n = 5, 62.5%), diabetes mellitus (n = 3, 37.5%), cerebrovascular disease (n = 3, 37.5%), ischemic heart disease (n = 1, 12.5%), and cardiac failure (n = 1). All patients had no history of trauma (n = 8, 100%). Six had a history of cigarette smoking. The aneurysm size ranged from 2.0 × 4.0 to 6.3 × 5.3 cm (mean, 3 × 5 cm). The surgical procedures used were four cases of total arch replacement and two cases of thoracic endovascular aortic repair. Two patients were not surgically treated. The median follow-up was 14.5 months (range, 2 months to 9 years). In the two patients who were not surgically treated, the aneurysm enlarged in one, and remained unchanged in the other. Of the six surgically managed cases, one was lost to follow-up, and another patient died of an unrelated cause. The remaining four cases had no enlargement of the aneurysm. No ruptures were reported in any of the cases. DAA should be considered when a saccular aneurysm is located in the minor curvature of the aortic arch and extending toward the left pulmonary trunk in adult patients. Differentiating adult DAA is important, because it is associated with a high risk of rupture due to the fragile nature of true aneurysms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA