RESUMO
Allosteric modulators bear great potential to fine-tune neurotransmitter action. Promising targets are metabotropic glutamate (mGlu) receptors, which are associated with numerous brain diseases. Orthosteric and allosteric ligands act in synergy to control the activity of these multidomain dimeric GPCRs. Here, we analyzed the effect of such molecules on the concerted conformational changes of full-length mGlu2 at the single-molecule level. We first established FRET sensors through genetic code expansion combined with click chemistry to monitor conformational changes on live cells. We then used single-molecule FRET and show that orthosteric agonist binding leads to the stabilization of most of the glutamate binding domains in their closed state, while the reorientation of the dimer into the active state remains partial. Allosteric modulators, interacting with the transmembrane domain, are required to stabilize the fully reoriented active dimer. These results illustrate how concerted conformational changes within multidomain proteins control their activity, and how these are modulated by allosteric ligands.
Assuntos
Receptores de Glutamato Metabotrópico , Regulação Alostérica , Ligantes , Receptores de Glutamato Metabotrópico/genética , Receptores de Glutamato Metabotrópico/agonistas , Receptores de Glutamato Metabotrópico/metabolismo , GlutamatosRESUMO
Cell surface receptors represent a vast majority of drug targets. Efforts have been conducted to develop biosensors reporting their conformational changes in live cells for pharmacological and functional studies. Although Förster resonance energy transfer (FRET) appears to be an ideal approach, its use is limited by the low signal-to-noise ratio. Here we report a toolbox composed of a combination of labeling technologies, specific fluorophores compatible with time-resolved FRET and a novel method to quantify signals. This approach enables the development of receptor biosensors with a large signal-to-noise ratio. We illustrate the usefulness of this toolbox through the development of biosensors for various G-protein-coupled receptors and receptor tyrosine kinases. These receptors include mGlu, GABAB, LH, PTH, EGF and insulin receptors among others. These biosensors can be used for high-throughput studies and also revealed new information on the activation process of these receptors in their cellular environment.
Assuntos
Técnicas Biossensoriais , Transferência Ressonante de Energia de Fluorescência , Ensaios de Triagem em Larga Escala , Receptores Proteína Tirosina Quinases/metabolismo , Receptores Acoplados a Proteínas G/metabolismo , Animais , Células HEK293 , Humanos , RatosRESUMO
Endogenous morphine and its derivatives (morphine-6-glucuronide [M6G]; morphine-3-glucuronide [M3G]) are formed by mammalian cells from dopamine. Changes in the concentrations of endogenous morphine have been demonstrated in several pathologies (sepsis, Parkinson's disease, etc.), and they might be relevant as pathological markers. While endogenous morphine levels are detectable using enzyme-linked immunosorbant assay (ELISA), mass spectrometry (MS) analysis was, so far, the only approach to detect and quantify M6G. This study describes the preparation of a specific anti-M6G rabbit polyclonal antibody and its validation. The specificity of this antibody was assessed against 30 morphine-related compounds. Then, a M6G-specific ELISA-assay was tested to quantify M6G in the plasma of healthy donors, morphine-treated, and critically ill patients. The antibody raised against M6G displays a strong affinity for M6G, codeine-6-glucuronide, and morphine-3-6-glucuronide, whereas only weak cross-reactivities were observed for the other compounds. Both M6G-ELISA and LC-MS/MS approaches revealed the absence of M6G in the plasma of healthy donors (controls, n = 8). In all positive donors treated with morphine-patch (n = 5), M6G was detected using both M6G-ELISA and LC-MS/MS analysis. Finally, in a study on critically ill patients with circulating endogenous morphine (n = 26), LC-MS/MS analysis revealed that 73% of the positive-patients (19 of 26), corresponding to high M6G-levels in M6G-ELISA, contained M6G. In conclusion, we show that endogenous M6G can be found at higher levels than morphine in the blood of morphine-naive patients. With respect to the interest of measuring endogenous M6G in pathologies, we provide evidences that our ELISA procedure represents a powerful tool as it can easily and specifically detect endogenous M6G levels.
Assuntos
Anticorpos/química , Derivados da Morfina/sangue , Animais , Especificidade de Anticorpos , Biomarcadores/sangue , Estudos de Casos e Controles , Estado Terminal , Ensaio de Imunoadsorção Enzimática , Humanos , Derivados da Morfina/imunologia , CoelhosRESUMO
The convenient and efficient synthesis of two macrocyclic ligands (15- and 18-membered) based on a dipyrido-6,7,8,9-tetrahydrophenazine (dpqc) or 2,2':6',2''-terpyridine (tpy) heterocycle and a DTTA (diethylenetriaminetriacetic acid) skeleton is described. In these ligands the DTTA skeleton contains an additional extracyclic functionality (NH(2) group) suitable for covalent attachment to bioactive molecules. These octa- and nonadentate ligands form very stable and luminescent neutral lanthanide complexes in aqueous solutions at physiological pH. The corresponding Eu(III) and Tb(III) complexes are characterized by a maximum absorption wavelength compatible with nitrogen laser excitation (337 nm) and attractive lifetimes and quantum yields. Further introduction of a maleimide bioconjugatable handle in the Eu(III) complexes was investigated and a valuable luminescence brightness above 1500 dm(3) mol(-1) cm(-1) at 337 nm was obtained with the corresponding Eu(III) tpy-derivative. Finally, these two luminescent chelates were grafted onto thiol residues of a model antibody (Mab GSS11) without loss of their luminescent properties.