Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 30(23): 41271-41278, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36366609

RESUMO

In this paper, we report a flexible wavelength-, pulse-controlled mode-locked all-fiber laser based on a novel fiber optic Lyot filter. The wavelength, pulse duration and spectral bandwidth of passive mode-locked lasers can be tuned by controlling the polarization controller. The proposed Lyot filter was constructed by a single-mode fiber insertion between two polarization-maintaining fibers. The filter bandwidth and laser output tunability were based on the birefringence characteristics of the polarization-maintaining fibers. This all-fiber laser is simple and stable and can be used for various applications where width-tunable or wavelength-tunable pulses are necessary.

2.
ScientificWorldJournal ; 2015: 341619, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26495422

RESUMO

The problem of optimising the target detection performance of MIMO radar in the presence of clutter is considered. The increased false alarm rate which is a consequence of the presence of clutter returns is known to seriously degrade the target detection performance of the radar target detector, especially under low SNR conditions. In this paper, a mathematical model is proposed to optimise the target detection performance of a MIMO radar detector in the presence of clutter. The number of samples that are required to be processed by a radar target detector regulates the amount of processing burden while achieving a given detection reliability. While Subspace Compressive GLRT (SSC-GLRT) detector is known to give optimised radar target detection performance with reduced computational complexity, it however suffers a significant deterioration in target detection performance in the presence of clutter. In this paper we provide evidence that the proposed mathematical model for SSC-GLRT detector outperforms the existing detectors in the presence of clutter. The performance analysis of the existing detectors and the proposed SSC-GLRT detector for MIMO radar in the presence of clutter are provided in this paper.

3.
Neurourol Urodyn ; 33(7): 1101-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24000163

RESUMO

AIMS: Assess patients' preferences in a pilot crossover study of two different electronic voiding diaries against a standard paper diary. Assess urological health professional (HP) opinions on the electronic bladder diary reporting system. METHODS: Two different electronic diaries were developed: (1) electronically read diary-a card with predefined slots read by a card reader and (2) e-diary-a handheld touch screen device. Data uploaded from either electronic diary produced an electronic report. We recruited 22 patients split into two cohorts for each electronic diary, 11 completed each type of electronic diary for 3 days either preceded or followed by a standard paper diary for 3 days. Both diaries were completed on the 7th day. Patients' perceptions of both diaries were recorded using a standardized questionnaire. A HP study recruited 22 urologists who were given the paper diary and the electronic reports. Time taken for analysis was recorded along with accuracy and HP preferences. RESULTS: The majority of patients (82%) preferred the e-diary and only 1/11 found it difficult to use. Patients had the same preference for the electronically read diary as the paper diary. The paper diary took 66% longer to analyze than the electronic report (P < 0.001) and was analyzed with an accuracy of 58% compared to 100%. Slightly more HP (9%) preferred the electronic report to the paper diary. CONCLUSIONS: This proposed e-diary with its intuitive interface has overcome previous deficiencies in electronic diaries with most patients finding the format user-friendly. Electronic reports make analysis and interpretation by HP quicker and more accurate.


Assuntos
Pessoal de Saúde , Cooperação do Paciente , Bexiga Urinária/fisiologia , Micção/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Cross-Over , Feminino , Humanos , Masculino , Prontuários Médicos , Pessoa de Meia-Idade , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA