Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Inflamm (Lond) ; 20(1): 39, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37978397

RESUMO

Clinical cases and experimental evidence revealed that electronic cigarettes (ECIG) induce serious adverse health effects, but underlying mechanisms remain to be fully uncovered. Based on recent exploratory evidence, investigating the effects of ECIG on macrophages can broadly define potential mechanisms by focusing on the effect of ECIG exposure with or without nicotine. Here we investigated the effect of ECIG-aerosol exposure on macrophages (MQ) phenotype, inflammatory response, and function of macrophages.MQ were cultured at air liquid interface and exposed to ECIG-aerosol. Oxidative stress was determined by reactive oxygen species (ROS), heat shock protein 60 (HSP60), glutathione peroxidase (GPx) and heme oxygenase1 (HMOX1). Lipid accumulation and lipid peroxidation were defined by lipid staining and level of malondialdehyde (MDA) respectively. MQ polarization was identified by surface expression markers CD86, CD11C and CD206 as well as pro-inflammatory and anti-inflammatory cytokines in gene and protein level. Phagocytosis of E. coli by MQ was investigated by fluorescence-based phagocytosis assay.ECIG-aerosol exposure in presence or absence of nicotine induced oxidative stress evidenced by ROS, HSP60, GPx, GPx4 and HMOX1 upregulation in MQ. ECIG-aerosol exposure induced accumulation of lipids and the lipid peroxidation product MDA in MQ. Pro-inflammatory MQ (M1) markers CD86 and CD11C but not anti-inflammatory MQ (M2) marker CD206 were upregulated in response to ECIG-aerosol exposure. In addition, ECIG induced pro-inflammatory cytokines IL-1beta and IL-8 in gene level and IL-6, IL-8, and IL-1beta in protein level whereas ECIG exposure downregulated anti-inflammatory cytokine IL-10 in protein level. Phagocytosis activity of MQ was downregulated by ECIG exposure. shRNA mediated lipid scavenger receptor 'CD36' silencing inhibited ECIG-aerosol-induced pro-inflammatory MQ polarization and recovered phagocytic activity of MQ.ECIG exposure alters lung lipid homeostasis and thus induced inflammation by inducing M1 type MQ and impair phagocytic function, which could be a potential cause of ECIG-induced lung inflammation in healthy and inflammatory exacerbation in disease condition.

2.
BMJ Open ; 13(7): e072582, 2023 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438074

RESUMO

OBJECTIVES: Studies on health effects of tobacco often rely on self-reported exposure data, which is subjective and can lead to misclassification. The aim of this study was to describe the prevalence of cigarette smoking, snus and e-cigarette use, as well as to validate self-reported tobacco use among young adults in Sweden. METHOD: Participants of a population-based Swedish cohort (n=3052), aged 22-25 years, assessed their tobacco use in a web questionnaire. Urinary cotinine was analysed in a subsample of the study population (n=998). The agreement between self-reported tobacco use and urinary cotinine was assessed using Cohen's Kappa coefficient (κ) at a cut-off level of 50 ng/mL. RESULTS: Patterns of tobacco use differed between men and women. Among men, 20.0% reported daily snus use, 5.8% daily cigarette smoking and 5.6% any e-cigarette use. In contrast, 3.2% of the women reported daily snus use, 9.0% daily cigarette smoking and 2.4% any e-cigarette use. Among the tobacco use categories, daily snus users had the highest levels of cotinine. Of reported non-tobacco users, 3.5% had cotinine levels above the cut-off, compared with 68.0% among both occasional cigarette smokers and snus users, 67.5% among all e-cigarette users and 94.7% and 97.8% among daily cigarette smokers and snus users, respectively. Agreement between self-reported tobacco use and urinary cotinine was classified as strong for daily use of cigarettes (κ=0.824) and snus (κ=0.861), while moderate to weak for occasional smoking (κ=0.618), occasional snus use (κ=0.573) and any e-cigarette use (κ=0.576). CONCLUSIONS: We found high validity of self-reported tobacco use in our study population, particularly for daily tobacco use. Further, we found that daily snus users were exposed to high levels of cotinine. Together with previous findings, our results indicate good validity of self-reported tobacco use among young adults.


Assuntos
Cotinina , Sistemas Eletrônicos de Liberação de Nicotina , Masculino , Humanos , Feminino , Adulto Jovem , Autorrelato , Suécia/epidemiologia , Coorte de Nascimento , Uso de Tabaco/epidemiologia
3.
Environ Res ; 208: 112760, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35065933

RESUMO

Despite the growing popularity of electronic cigarettes (e-cigarettes) over the last decade, few epidemiological studies have examined the influence on respiratory health in young adulthood. The aim of this study was to identify factors associated with e-cigarette use in young adulthood in Sweden, and to examine associations between e-cigarette use and lung function, respiratory symptoms, and obesity. This cross-sectional study included 3055 young adults from Sweden and used questionnaire and clinical data obtained at age 22-25 years. The prevalence of current e-cigarette use was 3.9% (n = 120). Few participants reported daily (0.4%) or exclusive (0.8%) use of e-cigarettes. In a multivariable adjusted logistic regression model, e-cigarette use was significantly associated with male gender (OR:3.2; 95% CI:1.5-6.7) and cigarette smoking (OR:14.7; 95% CI:5.5-39.0 for daily smoking). Prevalence of cough (15.0% vs. 8.5%) and mucus production (22.3% vs. 14.8%) was significantly higher among e-cigarette users compared to non-users, while no difference in lung function was observed. In addition, the prevalence of overweight/obesity was higher among e-cigarette users compared to non-users (36.7% vs. 22.3% with BMI≥25 kg/m2). In conclusion, cigarette smokers and males used e-cigarette more often compared to females and non-cigarette smokers. Attention should be given to respiratory symptoms among e-cigarette users, although our results may be explained by the concurrent use of conventional cigarettes, as the group of exclusive e-cigarette users were too small to allow firm conclusions.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Vaping , Adulto , Coorte de Nascimento , Estudos Transversais , Feminino , Humanos , Masculino , Obesidade/epidemiologia , Suécia/epidemiologia , Vaping/epidemiologia , Adulto Jovem
4.
Sci Rep ; 10(1): 20460, 2020 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-33235237

RESUMO

Limited toxicity data on electronic cigarette (ECIG) impede evidence-based policy recommendations. We compared two popular mixed fruit flavored ECIG-liquids with and without nicotine aerosolized at 40 W (E-smoke) with respect to particle number concentrations, chemical composition, and response on physiologically relevant human bronchial and alveolar lung mucosa models cultured at air-liquid interface. E-smoke was characterized by significantly increased particle number concentrations with increased wattage (25, 40, and 55 W) and nicotine presence. The chemical composition of E-smoke differed across the two tested flavors in terms of cytotoxic compounds including p-benzoquinone, nicotyrine, and flavoring agents (for example vanillin, ethyl vanillin). Significant differences in the expression of markers for pro-inflammation, oxidative stress, tissue injury/repair, alarm anti-protease, anti-microbial defense, epithelial barrier function, and epigenetic modification were observed between the flavors, nicotine content, and/ or lung models (bronchial or alveolar). Our findings indicate that ECIG toxicity is influenced by combination of multiple factors including flavor, nicotine content, vaping regime, and the region of respiratory tree (bronchial or alveolar). Toxic chemicals and flavoring agents detected in high concentrations in the E-smoke of each flavor warrant independent evaluation for their specific role in imparting toxicity. Therefore, multi-disciplinary approaches are warranted for comprehensive safety profiling of ECIG.


Assuntos
Brônquios/citologia , Marcadores Genéticos/efeitos dos fármacos , Nicotina/efeitos adversos , Alvéolos Pulmonares/citologia , Vaping/efeitos adversos , Brônquios/química , Brônquios/efeitos dos fármacos , Técnicas de Cultura de Células , Linhagem Celular , Sistemas Eletrônicos de Liberação de Nicotina , Aromatizantes/efeitos adversos , Aromatizantes/química , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Modelos Biológicos , Tamanho da Partícula , Alvéolos Pulmonares/química , Alvéolos Pulmonares/efeitos dos fármacos
5.
Toxicol In Vitro ; 61: 104617, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31381966

RESUMO

Diacetyl is an artificial flavouring agent, known to cause bronchiolitis obliterans. Diacetyl-induced pulmonary effects were assessed in human primary bronchial epithelial cells (PBEC) cultured at air-liquid interface (ALI). The PBEC-ALI models were exposed to clean air (sham) and diacetyl vapour (1, 3, 10 and 30 ppm) for 30 min. At 6 and 24 h post-exposure, cell medium was sampled for assessment of cytotoxicity measurement, and CXCL8, MMP9 secretion by ELISA. Pro-inflammatory, oxidative stress, tissue injury/repair, anti-protease and beta-defensin markers were assessed using qRT-PCR. Additionally, epidermal growth factor receptor ligands (amphiregulin) and anti-protease (SLPI) were analysed at 6 h, 8 h and 24 h post exposure to 1 and 10 ppm diacetyl. No significant cytotoxicity was observed at any exposure level. MMP9 was significantly increased in both apical and basal media at 24 h. Both SLPI and amphiregulin secretion were significantly increased following exposure to 10 ppm diacetyl. Exposure of PBEC-ALI model to diacetyl vapour resulted in significantly altered transcript expression of pro-inflammatory, oxidative stress, anti-protease, tissue injury/repair markers. Changes in transcript expression of significantly altered markers were more prominent 24 h post-exposure compared to 6 h. This study warrants further mechanistic investigations to elucidate the pulmonary effects of inhaled diacetyl vapour using physiologically relevant in vitro models.


Assuntos
Brônquios/citologia , Diacetil/toxicidade , Células Epiteliais/efeitos dos fármacos , Aromatizantes/toxicidade , Técnicas de Cultura de Células , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Citocinas/genética , Citocinas/metabolismo , Células Epiteliais/metabolismo , Receptores ErbB/metabolismo , Humanos , Ligantes , Metaloproteinase 9 da Matriz/genética , Modelos Biológicos , NF-kappa B/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA