Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Pharmaceutics ; 16(10)2024 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-39458668

RESUMO

BACKGROUND/OBJECTIVES: This study aimed to develop a fully validated HPLC-MS/MS method for quantifying total and unbound lenalidomide concentrations in human plasma. METHODS: Unbound concentrations were measured using plasma ultrafiltrate prepared with Amicon® Centrifugal Filters. Lenalidomide and lenalidomide-d5 (internal standard) were extracted from 50 µL of human plasma using liquid-liquid extraction. Chromatography was conducted with a Halo® C18 column using 0.1% formic acid and methanol (20:80, v/v) as the mobile phase. The mass spectrometer was operated in a positive ion mode with an electrospray ionization interface and multiple reaction monitoring modes. RESULTS: Calibration curves were linear over the range of 5 to 1000 ng/mL (r2 > 0.996) for both the total and unbound lenalidomide. For total lenalidomide concentrations, between-run precision (coefficients of variation) and accuracy were 1.70-7.65% and 94.45-101.10%, respectively. For unbound concentrations, inter-day precision and accuracy were 1.98-10.55% and 93.95-98.48%, respectively. CONCLUSIONS: We developed a highly reproducible, sensitive, and efficient bioanalytical method using a smaller volume of plasma sample (50 µL) with a relatively short run time (2.5 min). The proposed analytical method was successfully applied to measure total and unbound lenalidomide concentrations at various time points in multiple myeloma patients with renal impairment.

2.
Molecules ; 29(18)2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39339502

RESUMO

A highly accurate, precise, and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for ketotifen (KTF) estimation from Beagle dog plasma was developed and validated, with ketotifen-d3 (KTF-d3) as the internal standard (IS). KTF and IS were detected on an API 4000 mass spectrometer in multiple reaction monitoring (MRM) mode in electrospray ionization (ESI) positive ionization mode. The transitions were monitored at m/z 310.2 → 96.0 for KTF and m/z 313.2 → 99.1 for IS. KTF and IS were extracted from plasma using liquid-liquid extraction with methyl tertiary-butyl ether and then analyzed for 3 min with extracted samples (7 µL) into the LC-MS/MS system. Analytes were separated on a Luna® Hilic column (50 × 2.0 mm i.d., 3 µm) using the Nexera X2 HPLC. The mobile phase A consisted of 10 mmol/L ammonium formate (pH 3.0), while mobile phase B consisted of 0.05% formic acid in acetonitrile. The ratio of mobile phase was 5:95 (v/v) at a flow rate of 0.2 mL/min. The method has been thoroughly validated in accordance with the bioanalytical method validation guidelines established by the Ministry of Food and Drug Safety in Korea and the U.S. Food and Drug Administration, addressing selectivity, lower limit of quantification, linearity, carryover, precision, accuracy, recovery, matrix effect, and stability. The developed LC-MS/MS method was effectively utilized for the bioequivalence assessment of ketotifen in Beagle dog plasma following the oral administration of ketotifen syrup.


Assuntos
Cetotifeno , Espectrometria de Massas em Tandem , Equivalência Terapêutica , Animais , Cães , Espectrometria de Massas em Tandem/métodos , Cetotifeno/farmacocinética , Cetotifeno/sangue , Cetotifeno/administração & dosagem , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Masculino , Administração Oral , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massa com Cromatografia Líquida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA