Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 194
Filtrar
1.
J Invasive Cardiol ; 35(5): E225-E233, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36920890

RESUMO

BACKGROUND: Although first-generation drug-eluting stent (DES) devices have effectively achieved their main goal of reducing restenosis, their safety has been limited by suboptimal polymer biocompatibility, delayed stent endothelialization, and local drug toxicity, which ultimately prompted the development of new-generation DES options carrying biocompatible or even biodegradable polymers. AIMS: We sought to assess the vessel-healing pattern of the novel sirolimus-eluting Inspiron DES (Scitech Medical) using serial optical coherence tomography (OCT) and assuming the hypothesis that this thin-strut (75-µm), biodegradable-polymer DES promotes a faster healing, with very early strut coverage. METHODS: This is a prospective, multicenter, open-label, single-arm study enrolling 68 patients who underwent percutaneous coronary intervention guided by OCT. These patients were consecutively assigned into 3 groups. The first group had its OCT imaging follow-up performed at 3 months, the second group at 2 months, and the third group at 1 month. RESULTS: Mean age was 59.5 years, 70.6% were male, 41.2% had type 2 diabetes, and 29.4% presented with acute coronary syndrome. A total of 72 lesions were treated and 1.06 stents were implanted per patient. OCT assessment of the stents at 1, 2, and 3 months showed a strut coverage of 90.41%, 93.96%, and 97.21%, respectively (P=.04). CONCLUSION: The Inspiron DES showed an early strut healing pattern, with >90% of the struts covered by neointima within the first month and with almost all struts covered by the third month.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Stents Farmacológicos , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Doença da Artéria Coronariana/terapia , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Resultado do Tratamento , Desenho de Prótese , Stents , Polímeros
2.
Catheter Cardiovasc Interv ; 101(3): 579-586, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36640416

RESUMO

One limitation to transradial access (TRA) is the occurrence of spasms (RAS), for which the use of prophylactic medications is recommended. Improvement in TRA material combined with the increase in operators' expertise, might mitigate this benefit. We assess the effect of preventive nitroglycerin on RAS during TRA, evaluating the role of the operator's experience. Patients received 500 µg nitroglycerin or placebo. The operator's expertise was classified as: inexperienced (I), intermediate (M), and experienced (E). 2040 patients were included. Prophylactic use of nitroglycerin did not reduce RAS (10.8% vs. 13.4% (placebo), p = 0.07). RAS incidence was 14.5% in I, 12.5% in M, and 9.7% in E (p = 0.01). In group I, nitroglycerin reduced RAS (17.4% vs. 11.1%, p = 0.04), which was not observed in other groups. Overall, nitroglycerin does not prevent RAS, which is more common among inexperienced operators. More experienced operators could abolish preventive nitroglycerin use.


Assuntos
Nitroglicerina , Vasodilatadores , Humanos , Artéria Radial , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Espasmo/diagnóstico , Espasmo/etiologia , Espasmo/prevenção & controle
3.
JACC Cardiovasc Interv ; 15(10): 1009-1018, 2022 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-35331684

RESUMO

OBJECTIVES: The aim of this study was to evaluate whether administration of nitroglycerin at the beginning or end of a transradial approach (TRA) procedure would preserve radial patency. BACKGROUND: The TRA is becoming the preferred vascular access route in coronary interventions. Radial artery occlusion (RAO) is the most frequent complication. Routine vasodilator treatment aims to reduce spasm and possibly prevent RAO. METHODS: The authors designed a prospective, multicenter, randomized, double-blind, 2-by-2 factorial, placebo-controlled trial encompassing patients undergoing the TRA. Patients were randomized to either 500 µg nitroglycerin or placebo; each arm was also subrandomized to early (upon sheath insertion) or late (right before sheath removal) nitroglycerin administration to evaluate the superiority of nitroglycerin in the prevention of RAO with 24 hours on Doppler ultrasound. RESULTS: A total of 2,040 patients were enrolled. RAO occurred in 49 patients (2.4%). Fifteen of these patients (30.6%) showed re-establishment of flow at 30 days. Nitroglycerin, compared with placebo, did not reduce the risk for RAO at either of the 2 time points (early, 2.5% vs 2.3% [P = 0.66]; late, 2.3% vs 2.5% [P = 0.66]). By multivariable analysis, the presence of spasm (OR: 3.53; 95% CI: 1.87-6.65; P < 0.001) and access achieved with more than 1 puncture attempt (OR: 2.58; 95% CI: 1.43-4.66; P = 0.002) were independent predictors of RAO. CONCLUSIONS: The routine use of nitroglycerin was not associated with a reduction in the rate of RAO, regardless of the time of administration (at the beginning or end of the TRA procedure).


Assuntos
Arteriopatias Oclusivas , Artéria Radial , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Humanos , Nitroglicerina/efeitos adversos , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Espasmo/complicações , Espasmo/prevenção & controle , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 97(1): 167-174, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32445607

RESUMO

OBJECTIVES: The aim of the study was to evaluate mid- to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with Acurate neo™ (Boston Scientific, Boston, MA). BACKGROUND: TAVR is an established treatment for aortic stenosis (AS). Few data exist on mid- to long-term outcomes and durability after new-generation valves. METHODS: All consecutive patients (n = 104) who underwent Acurate neo™ implantation from 2012 to 2018 were included. Follow-up was systematically performed at 1, 6, 12, and 24 months and yearly thereafter. Outcomes were reported according to VARC-2, and structural valve deterioration (SVD) or bioprosthetic valve failure defined accordingly to new definitions. RESULTS: Mean age was 82 ± 5.4 years, 56.7% were female and the Society of Thoracic Surgeons score for mortality was 5.9 ± 4%. Patients were followed for a median of 3 years (1,092 days; IQR 1.5-4 years), and the maximum follow-up was 7 years. All-cause mortality values at 1 and 5 years were 8.5% and 40.5%, respectively. No relevant changes in mean gradient and orifice area occurred (7.9 ± 3.8 mmHg and 1.9 ± 0.3 cm2 at 1 year; 6.6 ± 2.1 mmHg and 1.8 ± 0.3 cm2 at 5 years), and there was a significant rate of paravalvular leaks resolution at 1, 2, and 3 years (p = .004; p < .001; p < .001, respectively). None of the patients had leaflet thrombosis or endocarditis. One patient developed SVD at 84 months. CONCLUSIONS: Acurate neo™ was associated with sustained echocardiographic results. Reassuring mid- to long-term outcomes was observed in this cohort of elderly patients with severe AS.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
J Invasive Cardiol ; 32(4): 147-152, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32160152

RESUMO

OBJECTIVES: The aim of this study was to compare two hemostatic techniques, minimum pressure technique and patent hemostasis, on radial artery occlusion (RAO) after transradial catheterization. BACKGROUND: RAO is an infrequent complication of transradial procedures. One of the strategies used to reduce this complication is the patent hemostasis technique. Use of minimum pressure in hemostatic wristband, without monitoring patency, might have the same efficacy for preventing RAO. METHODS: This is a multicenter study encompassing patients submitted to transradial catheterization. After pneumatic wristband application, the band was deflated to the lowest allowable volume while preserving hemostasis. Radial artery patency was subsequently evaluated. The group with no return of plethysmographic curve was labeled "minimum pressure," and the group in which the signal returned was labeled "patent hemostasis." RAO was verified by Doppler evaluation within the first 24 hours of the procedure. RESULTS: A total of 1082 patients were enrolled, with mean age of 61.4 ± 10.4 years. The majority (61.0%) were male and 34.5% had diabetes. Patent hemostasis was achieved in only 213 cases (20%). Early RAO occurred in 16 patients (1.8%) in the minimum pressure group and in 4 patients (1.9%) in the patent hemostasis group (P=.97). No major bleeding was observed among the entire cohort. EASY scale for hematoma grade was similar between the cohorts (EASY grades 1-3: 7.0% in the minimum pressure group vs 7.5% in the patent hemostasis group; P=.96). CONCLUSION: Checking radial patency during hemostatic compression may not be necessary after the procedure when adopting a mild and short hemostatic compression.


Assuntos
Arteriopatias Oclusivas , Cateterismo Periférico , Técnicas Hemostáticas , Grau de Desobstrução Vascular , Idoso , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/prevenção & controle , Cateterismo Cardíaco/efeitos adversos , Feminino , Hemostasia , Humanos , Masculino , Pessoa de Meia-Idade , Punções/efeitos adversos , Artéria Radial
6.
J Echocardiogr ; 17(3): 138-146, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30382559

RESUMO

BACKGROUND: Left ventricular diastolic function is an important prognostic marker in acute coronary syndrome. However, classification of the dysfunction grade using isolated echocardiographic parameters remains difficult. Therefore, it is necessary to combine multiple data in diagnostic algorithms. The purpose of this study was to evaluate the capacity of left atrial strain (LAS) components to classify left ventricular diastolic dysfunction (DD) grade. METHODS: Cross-sectional study with 109 consecutive patients admitted to the emergency room with acute coronary syndrome. Patients were referred for echocardiographic evaluation within 72 h. Mean values of LAS, corresponding to three phases of atrial function (reservoir, conduit and contraction), were obtained by speckle-tracking echocardiography. Patients were divided according to the diastolic dysfunction grade for later association with the LAS. RESULTS: The three LAS components showed moderate correlation with most diastolic variables (left atrial volume index, E/e' ratio and e' wave). In addition, there was related reduction of the LAS, which was inversely proportional to the DD grade (p < 0.05). LAS was effective for the identification of patients with DD grade III [area under the curve (AUC) for the reservoir = 0.99; conduit AUC = 0.89; contraction AUC = 0.99) and also those with DD grade II or III (reservoir AUC = 0.94; conduit AUC = 0.92; contraction AUC = 0.80]. CONCLUSIONS: LAS alone presented excellent capacity to classify DD in patients with acute coronary syndrome and may represent an additional tool for this purpose.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Angina Instável/diagnóstico por imagem , Função do Átrio Esquerdo , Remodelamento Atrial , Infarto do Miocárdio/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Angina Instável/fisiopatologia , Estudos Transversais , Diástole , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
7.
Catheter Cardiovasc Interv ; 90(1): 139-146, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28029207

RESUMO

OBJECTIVE: We sought to compare the new transcatheter aortic valve replacement (TAVR) device ACURATE neo (ACT) with the already established CoreValve (MCV) and SAPIEN XT (SXT) for the treatment of severe aortic stenosis (AS). BACKGROUND: Very few data on TAVR devices are available beyond MCV and SAPIEN and there is no previous study comparing ACT with MCV and SXT. METHODS: We prospectively evaluated consecutive patients who underwent transfemoral TAVR for the treatment of severe AS. Clinical outcomes were reported following Valve Academic Research Consortium 2 (VARC-2) criteria. RESULTS: A total of 162 patients (ACT n = 49, MCV n = 56, SXT n = 57), were included. MCV group had higher valve embolization/migration rates (ACT none; MCV 9%; SXT 2%; P = 0.034) causing lower device success rates (ACT 98%; MCV 86%; SXT 95%; P = 0.043). At 30 days, there was no significant difference in all-cause mortality (P = 0.22), cardiovascular mortality (P = 0.20), periprocedural myocardial infarction (P = 0.40), stroke (P = 0.64), major vascular complications (P = 0.48), life-threatening bleeding (P = 0.29), acute kidney injury stage 2/3 (P = 0.69), or VARC-2 composite early safety endpoints (P = 0.21). MCV group had higher rates of new permanent pacemaker implantation (ACT 6%; MCV 25%; SXT 11%; P = 0.013). Follow-up echocardiography showed no significant difference in aortic valve mean pressure gradient (P = 0.73) or moderate/severe aortic regurgitation (P = 0.19) between groups. CONCLUSIONS: In a "real world" registry, ACT compared favorably against the well-studied SXT and MCV devices in both safety and efficacy. MCV implantation was associated with lower device success rates and higher rates of new permanent pacemaker implantation. © 2016 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Equipe de Assistência ao Paciente , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Brasil , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
J Invasive Cardiol ; 27(12): E312-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26301560

RESUMO

PURPOSE: To evaluate the safety and efficacy of the Svelte Acrobat integrated delivery system (IDS) via radial approach with 5 Fr catheters. The direct stenting (DS) system enables easy delivery, deployment, and postdilatation of a cobalt-chromium stent. METHODS: Patients with coronary artery disease (CAD) were prospectively enrolled at three centers to undergo percutaneous coronary intervention with DS via radial approach using 5 Fr catheters. The primary endpoint was IDS success, which was defined as DS without postdilatation and final stenosis <20% with Thrombolysis in Myocardial Infarction (TIMI)-3 flow. RESULTS: Fifty consecutive patients with 55 lesions were included. The procedure success rate was 98%. The device could not cross the lesion in 2 cases, so DS success was 96%. Fifty lesions met the primary study objective; thus, IDS success rate was 91%. The procedure duration was 21 ± 9 minutes, fluoroscopy time was 7.3 ± 4.7 minutes, and contrast volume per vessel was 103 ± 33 cm3. The final residual stenosis, by quantitative coronary angiography, was 3.4 ± 4%. The reduced need for additional catheters resulted in a 20% procedural cost reduction. There were no bleeding or vascular complications. At 8 months, the event-free survival rate was 84%. CONCLUSIONS: DS using the Svelte Acrobat IDS via radial approach with low-profile catheters is safe and efficacious in select coronary artery disease patients, and its use is associated with potential procedural cost savings.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/cirurgia , Prestação Integrada de Cuidados de Saúde , Intervenção Coronária Percutânea/instrumentação , Stents , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Radial , Resultado do Tratamento
9.
Rev. bras. cardiol. invasiva ; 23(3): 201-206, jul.-set.2015. tab, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-794198

RESUMO

A revascularização miocárdica anatômica completa está associada a um melhor controle dossintomas anginosos e a menores índices de eventos cardíacos maiores tardios. No entanto, em substancial número de pacientes tratados por meio de intervenção coronária percutânea (ICP), não logramos sua obtenção. Assim, nosso objetivo foi avaliar os fatores associados à revascularização miocárdica incompleta (RMI) em casos de ICP multiarterial. Métodos: Estudo de coorte envolvendo 1.049 pacientes revascularizados de forma prospectiva e consecutivapor meio de ICP com tratamento de dois ou mais vasos, entre 2012 e 2014, divididos em dois grupos: RMI(n = 324; 30,9%) e revascularização miocárdica completa (n = 725; 69,1%).Resultados: A RMI foi significativamente associada a faixa etária maior (66,5 anos vs. 64,1 anos; p = 0,003),hipertensão arterial (92,2% vs. 86,0%; p = 0,006), insuficiência renal crônica (36.4% vs. 26.0%; p < 0,001), síndrome coronariana aguda (26,3% vs. 21,0%; p = 0,05), revascularização cirúrgica prévia (16,1% vs. 7,1%;p = 0,001), lesões em enxertos venosos (3,4% vs. 1,0%; p < 0,001) e oclusões crônicas (3,3% vs. 1,4%; p =0,005), bem como a menor acesso a stents farmacológicos (57,8% vs. 64,8%; p = 0,002). Os resultados clínicos hospitalares não diferiram entre os grupos.Conclusões: A RMI ocorreu em cerca de um terço dos casos tratados, tendo sido observada associação significativa, com um perfil clínico de maior risco e com intervenções em lesões alvo comumente associadas com menor sucesso do procedimento. O grau de revascularização não gerou impacto nosresultados clínicos da fase hospitalar...


Complete anatomical myocardial revascularization is associated with better anginacontrol and lower rates of cardiac events. However, in a significant number of patients treated bypercutaneous coronary intervention (PCI), complete revascularization is not achieved. Thus, the aimof this study was to evaluate factors associated with incomplete myocardial revascularization (IMR) in multivessel PCI patients. Methods: This was a cohort study involving 1,049 prospectively and consecutively revascularized patients through PCI with treatment of two or more vessels, between 2012 and 2014, divided into two groups: IMR(n = 324; 30.9%) and complete myocardial revascularization (n = 725; 69.1%). Results: IMR was significantly associated with older age (66.5 years vs. 64.1 years; p = 0.003), arterial hypertension (92.2% vs. 86.0%; p = 0.006), chronic renal failure (36.4 % vs. 26.0%; p < 0.001), acute coronary syndrome (26.3% vs. 21.0%; p = 0.05), previous surgical revascularization (16.1% vs. 7.1 %; p = 0.001), saphenous venous graft lesions (3.4% vs. 1.0%, p < 0.001), and chronic occlusions (3.3% vs. 1.4%, p = 0.005), as well as lower access to drug-eluting stents (57.8% vs. 64.8%; p = 0.002). In-hospital clinical outcomes did not differ between the groups. Conclusions: IMR occurred in approximately one-third of treated cases, and a significant association was observed with a higher-risk clinical profile and with target lesion interventions commonly associated with lower procedure success. The degree of revascularization had no impact on in-hospital clinical outcomes...


Assuntos
Humanos , Masculino , Feminino , Idoso , Intervenção Coronária Percutânea/métodos , Pacientes , Revascularização Miocárdica/métodos , Vasos Coronários/cirurgia , Angiografia Coronária/métodos , Interpretação Estatística de Dados , Atenção Terciária à Saúde/métodos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/terapia , Estudos de Coortes , Heparina/administração & dosagem , Stents Farmacológicos
10.
JACC Cardiovasc Interv ; 8(7): 984-90, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26088516

RESUMO

OBJECTIVES: This study aimed to assess 6-month outcomes in patients with implantable cardioverter-defibrillators (ICDs) undergoing renal sympathetic denervation (RSD) for refractory ventricular arrhythmias (VAs). BACKGROUND: ICDs are generally indicated for patients at high risk of malignant VAs. Sympathetic hyperactivity plays a critical role in the development, maintenance, and aggravation of VAs. METHODS: A total of 10 patients with refractory VA underwent RSD. Underlying conditions were Chagas disease (n = 6), nonischemic dilated cardiomyopathy (n = 2), and ischemic cardiomyopathy (n = 2). Information on the number of ventricular tachycardia (VT)/ventricular fibrillation (VF) episodes and device therapies (antitachycardia pacing/shocks) in the previous 6 months as well as 1 and 6 months post-treatment was obtained from ICD interrogation. RESULTS: The median number of VT/VF episodes/antitachycardia pacing/shocks 6 months before RSD was 28.5 (range 1 to 106)/20.5 (range 0 to 52)/8 (range 0 to 88), respectively, and was reduced to 1 (range 0 to 17)/0 (range 0 to 7)/0 (range 0 to 3) at 1 month and 0 (range 0 to 9)/0 (range 0 to 7)/0 (range 0 to 3) at 6 months afterward, respectively. There were no major procedure-related complications. Two patients experienced sustained VT within the first week; in both cases, no further episodes occurred during follow-up. Two patients were nonresponders: 1 with persistent idioventricular rhythm and 1 with multiple renal arteries and incomplete ablation. Three patients died during follow-up. None of the deaths was attributed to VA. CONCLUSIONS: In patients with ICDs and refractory VAs, RSD was associated with reduced arrhythmic burden with no procedure-related complications. Randomized controlled trials investigating RSD for treatment of refractory VAs in patients with increased sympathetic activity are needed.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Rim/irrigação sanguínea , Artéria Renal/inervação , Simpatectomia/métodos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Brasil , Ablação por Cateter/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Simpatectomia/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia
11.
J Interv Cardiol ; 28(4): 339-47, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26086603

RESUMO

OBJECTIVES: To determine the impact of percutaneous coronary intervention (PCI) performed at the same time of the peak concentration of rosuvastatin to reduce periprocedural myocardial infarction (PMI). BACKGROUND: Prior studies suggest that a high dose of statin before PCI reduce periprocedural myocardial infarction. However, there is no information regarding the elective PCI performed at the time of the peak of statin concentration to reduce PMI. METHODS: From 2001 to 2013, at a single center in Brazil we enrolled 544 patients who underwent elective PCI and after exclusions for baseline biases in clinical and angiographic characteristics, yielding 528 patients, we prospectively randomly assigned them to either a high loading dose of Rosuvastatin before PCI (n = 264) or standard treatment (n = 264). After exclusions for biases in procedural characteristics a total of 487 patients underwent to end points analysis. The primary outcome was the incidence of MB fraction of creatine kinase (CK-MB) greater than three times the upper limit of normal. RESULTS: The primary end point occurred in 7.6% in the rosuvastatin and 4.8% in the control group (P = 0.200). There was a higher incidence in elevation of CK-MB than normal baseline in the rosuvastatin (67.1% vs 59.2%, P = 0.701). There was no difference in major adverse event (0% in the rosuvastatin group vs 0.8% in control).


Assuntos
Doença da Artéria Coronariana/terapia , Creatina Quinase Forma MB/sangue , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Intervenção Coronária Percutânea , Rosuvastatina Cálcica/administração & dosagem , Biomarcadores/sangue , Relação Dose-Resposta a Droga , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Estudos Prospectivos
12.
Rev. bras. cardiol. invasiva ; 23(2): 124-129, abr.-jun. 2015. tab, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-786995

RESUMO

Introdução: A utilização crescente do implante transcateter de prótese valvar aórtica (TAVI) em pacientes de alto risco, em especial naqueles com disfunção ventricular, justifica uma avaliação mais profunda da seleção e dos resultados do procedimento. Utilizamos nosso banco de dados para caracterizar o perfil dos pacientes e avaliar os resultados do TAVI de acordo com o grau de disfunção ventricular.Métodos: Estudo observacional longitudinal no qual foram incluídos todos os pacientes com estenose aórtica (EAo) grave, submetidos ao TAVI entre 2009 e 2014, e comparados àqueles com fração de ejeção do ventrículo esquerdo (FEVE) ≤ 40% vs. > 40%. Foram avaliados os desfechos de segurança e eficácia em 30dias e 1 ano. Resultados: Dentre os 172 pacientes, 20 (11,6%) apresentavam FEVE ≤ 40%. Esses pacientes eram mais jovens, com maior prevalência de tabagismo, infarto agudo do miocárdio prévio, cirurgia de revascularizaçãomiocárdica, marca-passo definitivo e hipertensão arterial pulmonar. Também se observou, nesse grupo, maior frequência de classes funcionais mais elevadas. O grupo com FEVE ≤ 40% apresentou menor gradiente valvar aórtico médio para área valvar equivalente. As taxas de sucesso do procedimento não diferiram entre os grupos. Não foram observadas diferenças na mortalidade, nos eventos coronarianos, cerebrovasculares, sangramentos, complicações vasculares e disfunção renal aguda no acompanhamento de 30 dias e 1 ano. No grupo FEVE ≤ 40%, a média da FEVE elevou-se de 31,5 para 45,1% 1 ano após o procedimento (p = 0,002).Conclusões: O TAVI em pacientes com EAo grave e FEVE ≤ 40% não aumenta o risco de complicações e estáassociado à melhora da FEVE.


Background: The increasing use of transcatheter aortic valve implantation (TAVI) in high-risk patients, especially those with ventricular dysfunction, justifies further evaluation of the selection and the results of the procedure. A database was used to characterize the profile of patients and evaluate TAVI results according to the degree of ventricular dysfunction.Methods: This was a longitudinal observational study that included all patients with severe aortic stenosis(AoS) submitted to TAVI between 2009 and 2014, comparing those with left ventricular ejection fraction (LVEF) ≤ 40% vs. > 40%. The safety and efficacy outcomes were evaluated at 30 days and 1 year. Results: Of the 172 patients, 20 (11.6%) had LVEF ≤ 40%. These patients were younger, with a higherprevalence of smoking, previous acute myocardial infarction, coronary artery bypass graft surgery, permanent pacemaker, and pulmonary artery hypertension. Higher functional classes were also more often observed in this group. The group with LVEF ≤ 40% had lower mean aortic valve gradient for anequivalent valve area. The procedure success did not differ between groups. There were no differences in mortality in coronary and cerebrovascular events, bleeding, vascular complications, and acute renal failure in the 30 day and 1 year follow-up. In the LVEF ≤ 40% group, the mean LVEF increased from 31.5 to 45.1% 1 year after the procedure (p = 0.002). Conclusions: TAVI in patients with severe AoS and LVEF ≤ 40% does not increase the risk of complications and is associated with LVEF improvement.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Disfunção Ventricular Esquerda/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Interpretação Estatística de Dados , Aspirina/administração & dosagem , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Estudo Observacional , Próteses e Implantes , Prognóstico , Volume Sistólico
13.
Rev. bras. cardiol. invasiva ; 23(2): 84-90, abr.-jun. 2015. tab, graf
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-786988

RESUMO

Introdução: Cardiodesfibriladores implantáveis (CDIs) são geralmente indicados para pacientes com arritmias malignas considerados de alto risco. A hiperatividade simpática desempenha um papel crítico no desenvolvimento, na manutenção e no agravamento de arritmias ventriculares. Novas opçõesde tratamento nessa população representam uma necessidade clínica. Nosso objetivo foi relatar osresultados de pacientes com CDIs e tempestade elétrica submetidos à denervação simpática renal paracontrole da arritmia. Métodos: Oito pacientes com CDIs internados por tempestade elétrica refratária ao tratamento médico otimizado foram submetidos à denervação simpática renal. Condições subjacentes foram: doença de Chagas (n = 6), cardiomiopatia dilatada não isquêmica (n = 1) e cardiomiopatia isquêmica (n = 1). As informações sobre o número de taquicardias ventriculares/fibrilações ventriculares e episódios de terapiasantitaquicardia na última semana pré-procedimento e nos 30 dias pós-tratamento foram obtidas por meiode interrogação dos CDIs. Resultados: As medianas dos episódios de taquicardias ventriculares/fibrilações ventriculares, sobreestimulaçãoe choques na semana que antecedeu a denervação simpática renal foram de 29 (9 a 106), 23 (2 a 94) e 7,5 (1 a 88), sendo significativamente reduzidas para 0 (0 a 12), 0 (0 a 30) e 0 (0 a 1), respectivamente, 1 mês após o procedimento (p = 0,002; p = 0,01; p = 0,003). Nenhum paciente morreu durante o acompanhamento. Não ocorreram complicações maiores relacionadas ao procedimento.Conclusões: Em pacientes com CDIs e tempestade elétrica refratária ao tratamento médico otimizado, a denervação simpática renal reduziu significativamente a carga de arritmia e, consequentemente, as sobre-estimulações e os choques. Ensaios clínicos randomizados, no contexto de denervação simpática renal para controle de arritmias cardíacas refratárias, são necessários para trazer maior robustez aos nossos achados.


Background: Implantable cardioverter-defibrillators (ICDs) are usually indicated for patients with malignant arrhythmias considered as high risk. Sympathetic hyperactivity plays a critical role in thedevelopment, maintenance, and worsening of ventricular arrhythmias. New treatment options in thispopulation represent a clinical necessity. This study’s objective was to report the outcomes of patients with ICDs and electrical storm submitted to renal sympathetic denervation for arrhythmia control. Methods: Eight patients with ICDs admitted for electrical storm refractory to optimal medical therapy underwent renal sympathetic denervation. Underlying diseases included Chagas disease (n = 6), non-ischemic dilated cardiomyopathy (n = 1), and ischemic cardiomyopathy (n = 1).Information on the number of episodes of ventricular tachycardia/ventricular fibrillation and antitachycardia therapies in the week before the procedure and 30 days after treatment were obtained through interrogation of the ICDs.Results: The median numbers of episodes of ventricular achycardia/ ventricular fibrillation,antitachycardia pacing, and shocks in the week before renal sympathetic denervation were 29 (9 to 106), 23 (2 to 94), and 7.5 (1 to 88), and significantly reduced to 0 (0 to 12), 0 (0 to 30), and 0 (0 to 1), respectively, 1 month after the procedure (p = 0.002; p = 0.01; p = 0.003, respectively). No patients diedduring follow-up. There were no major complications related to the procedure.Conclusions: In patients with ICDs and electrical storm refractory to optimal medical treatment, renal sympathetic denervation significantly reduced arrhythmia load and, consequently, antitachycardia pacing and shocks. Randomized clinical trials in the context of renal sympathetic denervation tocontrol refractory cardiac arrhythmias are needed to further support these findings.


Assuntos
Humanos , Masculino , Feminino , Idoso , Ablação por Cateter/métodos , Cardiopatias/etiologia , Desfibriladores Implantáveis , Simpatectomia/métodos , Terapêutica , Antiarrítmicos/administração & dosagem , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Artéria Renal/fisiopatologia , Doença Crônica , Estudos Prospectivos , Heparina/administração & dosagem , Nefropatias/fisiopatologia , Nefropatias/terapia
14.
Rev. bras. cardiol. invasiva ; 23(1): 28-37, abr.-jun.2015. ilus, tab
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-782172

RESUMO

No estudo BIOACTIVE, avaliamos as respostas vasculares após implante do stent eluidor de biolimus A9 (SEB; BioMatrix®) e o stent eluidor de everolimus (SEE; XIENCE V®). Apresentamos a análise detomografia de coerência óptica (OCT) 6 meses pós-intervenção. Métodos: Os pacientes foram randomizados para tratamento com SEB (n = 22) ou SEE (n = 18). O desfecho primário foi a frequência de hastes não cobertas e mal apostas pela OCT. Resultados: A OCT foi realizada em 26 pacientes (SEB: n = 15; SEE: n = 11) e foram analisadas 749 imagens tomográficas e 7.725 hastes de stent. SEB e SEE apresentaram áreas luminais e dos stents semelhantes.A área de hiperplasia neointimal, a espessura neointimal e o porcentual de obstrução intra-stent (8,44 ± 5,10% vs. 9,21 ± 6,36%; p = 0,74) foram similares. As taxas de hastes não cobertas (SEB: 2,10 ± 3,60% vs. SEE: 2,46 ± 2,15%; p = 0,77) e mal apostas (SEB: 0,48 ± 1,48% vs. SEE 0,44 ± 1,05%; p = 0,94) foram baixas e semelhantes. A frequência de frames com sinais compatíveis com infiltrado inflamatório peri-haste foi baixa e similar entre SEB (15,53 ± 20,77%) e SEE (11,70 ± 27,51%; p = 0,68).Conclusões: Stents farmacológicos de segunda geração SEB e SEE se mostraram igualmente eficientes emsuprimir a formação neointimal aos 6 meses, com respostas vasculares favoráveis. A frequência de framescom sinais de infiltrado peri-haste por paciente foi baixa, e menor do que a historicamente observada comos stents farmacológicos de primeira geração...


In BIOACTIVE study, we evaluated vascular responses after the implant of biolimus A9-eluting stent (BES; BioMatrixTM) and the everolimus-eluting stent (EES; XIENCE VTM). In this study, we present the optical coherence tomography analysis (OCT) 6 months post-intervention. Methods: Patients were randomized to treatment with BES (n = 22) or EES (n = 18). The primary outcome was the frequency of non-covered, poorly positioned struts by OCT.Results: OCT was performed in 26 patients (BES: n = 15; EES: n = 11) and 749 tomographic images and 7,725stent struts were analyzed. BES and EES showed similar luminal and stent areas. Neointimal hyperplasia area, neointimal thickness and the percentage of in-stent obstruction (8.44 ± 5.10% vs. 9.21 ± 6.36%; p = 0.74) were similar. The rates of not covered struts (BES: 2.10 ± 3.60% vs. ESS: 2.46 ± 2.15%, p = 0.77) and poorly positioned struts (BES: 0.48 ± 1.48% vs. EES 0.44 ± 1.05%, p = 0.94) were similarly low. The frequency of frames with signs consistent with peri-strut inflammatory infiltrate was low and similar between BES (15.53 ± 20.77%) and EES (11.70 ± 27.51%; p = 0.68). Conclusions: The second-generation drug-eluting stents BES and EES were equally effective at suppressing the neointimal formation after 6 months, with favorable vascular responses. The frequency of frameswith peri-strut infiltrate signals per patient was low, and lower than that observed historically with firstgenerationdrug-eluting stents...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença das Coronárias/fisiopatologia , Doença das Coronárias/terapia , Stents Farmacológicos , Tomografia de Coerência Óptica/métodos , Interpretação Estatística de Dados , Estudos Prospectivos , Intervenção Coronária Percutânea/métodos , Polímeros/uso terapêutico , Resultado do Tratamento , Trombose/complicações , Trombose/diagnóstico
15.
Rev. bras. cardiol. invasiva ; 23(1): 22-27, abr.-jun.2015. tab
Artigo em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-782171

RESUMO

O stent liberador de everolimus XIENCE V® é um stent farmacológico de nova geração que incorpora uma plataforma de cromo-cobalto de baixo perfil (81 m) e um polímero de elevada biocompatibilidade (fluoropolímero), o qual carreia e controla a liberação do fármaco everolimus. Estudos recentes demonstram segurança e eficácia sustentadas do dispositivo XIENCE V® no tratamento de populações da prática clínica. Nosso objetivo foi reportar resultados clínicos de 12 meses do protocolo brasileiro BRAVO. Métodos: O registro BRAVO foi um estudo prospectivo, não randomizado, de braço único, multicêntrico (25centros), que avaliou os resultados clínicos tardios de 535 pacientes minimamente selecionados, tratados com o stent farmacológico XIENCE V®.Resultados: Cerca de 40% dos pacientes tinham diabetes, 25% infarto agudo do miocárdio prévio e 42% apresentaram-se com síndrome coronária aguda. A maioria das lesões (69%) era de elevada complexidade(ACC/AHA tipo B2/C). As médias da extensão e do diâmetro nominais dos stents foram, respectivamente, 19,9 ± 5,3 mm e 3,0 ± 0,4 mm. Os sucessos angiográfico e de procedimento foram de 99,7 e 98%, respectivamente. Aos 12 meses, a taxa cumulativa de eventos cardíacos adversos maiores, disponível em 100% dos pacientes, foi de 5,6% (morte cardíaca: 1,3%; infarto agudo do miocárdio: 3,0%; revascularização da lesão-alvo: 2,2%). Já a trombose de stent ocorreu em cinco pacientes (0,9%), sendo reportada apenas uma ocorrência entre 6 e 12 meses. Conclusões: O stent farmacológico XIENCE V® demonstrou segurança e eficácia sustentadas ao final de 12meses no tratamento de lesões coronárias complexas em pacientes da prática diária...


The Xience VTM everolimus-eluting stents is a new generation drug-eluting stent (DES)that incorporates a low profile cobalt-chromium platform (81 m) and a highly biocompatible polymer(fluoropolymer), which carries and controls the release of everolimus. Recent studies have demonstrated sustained safety and efficacy of the Xience VTM in the treatment of real-world populations. Our aim was to report the clinical results of 12 months of the BRAVO Brazilian protocol. Methods: The BRAVO Registry was a prospective, non-randomized, single-arm, multicenter (25 centers) study that evaluated the late clinical results of 535 minimally selected patients treated with the drug eluting stent Xience VTM in Brazilian daily practice. Results: Overall, 40% of patients had diabetes, 25% prior myocardial infarction, and 42% presented with acute coronary artery syndrome. The majority of lesions (69%) was highly complex (ACC/AHA type B2 or C).The mean length and the nominal stent diameter were 19.9 ± 5.3 mm and 3.0 ± 0.4 mm, respectively.The angiographic and procedural successes were 99.7 and 98%, respectively. At 12 months, the cumulative rate of major adverse cardiac events, available in 100% of patients, was 5.6% (cardiac death: 1.3%; acute myocardial infarction: 3.0%; revascularization of the target lesion: 2.2%). Stent thrombosis occurred in 5 patients (0,9%), and only 1 case was reported between 6 and 12 months. Conclusions: The drug-eluting stent Xience V™ demonstrated sustained safety and efficacy up to 12 months in the treatment of complex coronary lesions in patients from daily practice...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença das Coronárias , Intervenção Coronária Percutânea/métodos , Pacientes , Stents Farmacológicos , Trombose/complicações , Trombose/diagnóstico , Interpretação Estatística de Dados , Estudos Prospectivos , Fatores de Risco , Próteses e Implantes/métodos , Resultado do Tratamento
16.
Rev. bras. cardiol. invasiva ; 23(1): 17-21, abr.-jun.2015. tab, graf
Artigo em Português | LILACS, SES-SP | ID: lil-782170

RESUMO

Stents farmacológicos (SF) de segunda geração demonstraram melhor desempenho clínico que os de primeira geração, sobretudo pela redução nas taxas de trombose, mas ainda não está claro se esse benefício se estende a diabéticos da prática diária. Objetivamos comparar o desempenho de pacientes diabéticos não selecionados tratados com SF eluidores de sirolimus (SES; primeira geração) vs. SF eluidoresde everolimus (SEE; segunda geração).Métodos: Entre 2007 e 2014, 798 diabéticos foram tratados com SES (n = 414) ou SEE (n = 384) e incluídosnesta análise. Seguimento clínico tardio foi obtido em 99,4% da população e os grupos foram comparados quanto à ocorrência de eventos cardíacos adversos maiores (ECAM) e trombose de stent. Resultados: A idade da população foi semelhante, com predomínio do sexo masculino. Em ambas as coortes, a apresentação clínica mais frequente foi a doença coronária estável. Número de vasos tratados (1,50 ± 0,62 vs. 1,52 ± 0,72; p = 0,88) e extensão total de stents (36,1 ± 20,4 mm vs. 37,7 ± 22,2 mm; p = 0,32) foram semelhantes. Os pacientes tratados com SEE apresentaram menores taxas de ECAM (15% vs. 6,8%; p < 0,001), sobretudo à custa de menor mortalidade cardíaca (5,3% vs. 1,3%; p < 0,001). Observou-se também menor ocorrência de trombose de stent definitiva/provável com SF de segunda geração (3,4% vs. 0,5%; p = 0,004).Conclusões: Nesta experiência unicêntrica, o uso de SEE em diabéticos mostrou-se com menor mortalidadecardíaca e trombose da endoprótese. Esse benefício se fez mais evidente no seguimento mais tardio...


Despite the better clinical performance of second-generation drug-eluting stents (DES)when compared to first-generation DES in controlled trials, mainly due to reduction in thrombosis rate, it remains unclear whether this benefit extends to diabetic patients treated in the daily practice. We sought to compare the clinical outcomes of unselected diabetic patients treated with either sirolimus eluting stents - SES (first-generation DES) or everolimus-eluting stents - EES (second-generation DES). Methods: Between January 2007 and October 2014 a total of 798 diabetic patients were treated with SES(n = 414) and EES (n = 384). Long-term clinical follow-up was achieved in 99,4% of the population andthe groups were compared regarding the occurrence of major adverse cardiac events (MACE) and stent thrombosis. Results: In both cohorts age was similar, and most patients were male. Stable coronary disease was the most frequent clinical presentation. The number of treated vessels (1.50 ± 0.62 vs. 1.52 ± 0.72; p = 0.88)and the total stent length (36.1 ± 20.4 vs. 37.7 ± 22.2 mm; p = 0.32) were similar between groups. Patients treated with EES showed lower rates of MACE (15% vs. 6.8%, p < 0.001), mainly due to a lower cardiac death(5.3% vs. 1.3%, p < 0.001). There was also less definitive/ probable thrombosis with the second generation DES (3.4% vs. 0.5%, p = 0.004)...


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/terapia , Sirolimo/administração & dosagem , Stents Farmacológicos , Trombose Coronária/fisiopatologia , Estudos Prospectivos , Fatores de Risco , Fibrinolíticos/administração & dosagem , Próteses e Implantes/métodos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
17.
Echocardiography ; 32(7): 1122-30, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25327943

RESUMO

BACKGROUND: Left atrial (LA) dilation is associated with worse prognosis in various clinical situations including chronic mitral regurgitation (MR). Real time three-dimensional echocardiography (3DE) has allowed a better assessment of LA volumes and function. Little is known about LA size and function in early postoperative period in symptomatic patients with chronic organic MR. We aimed to investigate these aspects. METHODS: By means of 3DE, 43 patients with symptomatic chronic organic MR were prospectively studied before and 30 days after surgery (repair or bioprosthetic valve replacement). Twenty subjects were studied as controls. Maximum (Vol-max), minimum, and preatrial contraction LA volumes were measured and total, passive, and active LA emptying fractions were calculated. RESULTS: Before surgery patients had higher LA volumes (P < 0.001) but smaller LA emptying fractions than controls (P < 0.01). After surgery there was a reduction in all 3 LA volumes and an increase in active atrial emptying fraction (AAEF). Multivariate analysis showed that independent predictors of early postoperative Vol-max reduction were preoperative diastolic blood pressure (coefficient = -0.004; P = 0.02), lateral mitral annular early diastolic velocity (e') (coefficient = 0.023; P = 0.008), and the mean transmitral diastolic gradient increment (coefficient = -0.035; P < 0.001). Furthermore, e' was also independently associated with AAEF increase (odds ratio = 1.66, P = 0.027). CONCLUSION: Early LA reverse remodeling and functional improvement occur after successful surgery of symptomatic organic MR regardless of surgical technique. Diastolic blood pressure and transmitral mean gradient augmentation are variables negatively related to Vol-max reduction. Besides, e' is positively correlated with both Vol-max reduction and AAEF increase.


Assuntos
Remodelamento Atrial/fisiologia , Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Adulto , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Prospectivos
18.
Rev. bras. cardiol. invasiva ; 22(3): 252-257, Jul-Sep/2014. tab, graf
Artigo em Português | LILACS-Express | LILACS, SES-SP | ID: lil-732777

RESUMO

Introdução: O volume de hiperplasia intimal correlaciona-se com a injúria arterial após implante de stents não farmacológicos. No entanto, pouco se sabe a respeito do impacto da injúria arterial na resposta inflamatória/proliferativa com os stents farmacológicos. Investigamos o impacto da injúria arterial, avaliada pela relação balão/artéria, no volume de obstrução neontimal, avaliado pelo ultrassom intracoronário 12 meses após o implante de stents farmacológicos com eluição de zotarolimus. Métodos: A relação balão/artéria foi definida como a razão do diâmetro máximo do balão, obtido no implante ou na pós-dilatação, e o diâmetro de referência do vaso pré-procedimento. Os pacientes foram categorizados em dois grupos: relação balão/artéria alta (≥ 1,15) e relação balão/artéria baixa (< 1,15). Resultados: Foram incluídos 86 pacientes, nos grupos relação balão/artéria baixa (n = 47/48 lesões) ou relação balão/artéria alta (n = 39/48 lesões). As características clínicas, angiográficas e do procedimento não diferiram entre os grupos, à exceção do diâmetro de referência dos vasos (2,73 ± 0,45 mm vs. 2,97 ± 0,40 mm; p = 0,01). Aos 12 meses, observou-se semelhante perda tardia intra-stent (0,59 ± 0,32 mm vs. 0,62 ± ...


Background: Intimal hyperplasia volume is correlated to arterial injury after bare-metal stenting. However, little is known about the impact of arterial injury on the inflammatory/ proliferative response with drug-eluting stents. We investigated the impact of arterial injury, evaluated by the balloon/artery ratio, on neointimal hyperplasia volume obstruction, evaluated by intravascular ultrasound, 12 months after zotarolimus-eluting stent implantation. Methods: Balloon/ artery ratio was defined as the ratio of the maximum balloon diameter, using the maximal implantation or post-dilatation pressure, and the reference diameter of the vessel obtained before the procedure. Patients were divided into two groups: high balloon/artery ratio (≥ 1.15) and low balloon/artery ratio (< 1.15). Results: A total of 86 patients were included in the low balloon/artery ratio group (n = 47/48 lesions) or high balloon/artery ratio (n = 39/48 lesions). The clinical, angiographic and procedurerelated characteristics were not different between groups, except for the vessel reference diameter (2.73 ± 0.45 mm vs. 2.97 ± 0.40 mm; p = 0.01). At 12 months, similar in-stent late loss was observed (0.59 ± 0.32 mm vs. 0.62 ± 0.42 mm; p = 0.92), as well as binary restenosis (4.2% in both cohorts; p > 0.99). Instent neointimal hyperplasia volume obstruction (15.2 ± 14.3% vs. 12.5 ± 10.1%; p = 0.62) showed no difference between groups. No correlation was observed between balloon/artery ratio ...

19.
Rev. bras. cardiol. invasiva ; 22(3): 216-224, Jul-Sep/2014. tab, graf
Artigo em Português | LILACS-Express | LILACS, SES-SP | ID: lil-732779

RESUMO

Introdução: O implante por cateter de prótese aórtica (TAVI, do inglês transcatheter aortic valve implantation) constitui tratamento alternativo para pacientes com estenose aórtica de alto risco cirúrgico ou inoperáveis. Para adquirir competência, o grupo multidisciplinar deve receber treinamento específico e acumular experiência na execução do TAVI. Contudo, sua curva de aprendizado não está bem estabelecida. Nosso objetivo foi analisar o impacto da curva de aprendizado na seleção de pacientes, nos aspectos técnicos e nos resultados clínicos do TAVI. Métodos: Estudo observacional e prospectivo dos primeiros 150 pacientes submetidos a TAVI por via femoral, entre janeiro de 2009 e dezembro de 2013 divididos em tercis (n = 50) de acordo com a data do procedimento. Os desfechos foram definidos conforme os critérios Valve Academic Research Consortium-2 (VARC-2). Resultados: A idade foi de 82,5 ± 6,7 anos, sendo 44% homens e 75% em classe NYHA III/IV. O EuroSCORE (24,2 ± 13% vs. 21,2 ± 10,8% vs. 23,4 ± 14,3%) e o STS Score (5,9 ± 2,9% vs. 6,7 ± 4,3% vs. 5,8 ± 3,1%) foram similares entre os grupos. Observou-se redução gradativa nos tempos do procedimento (107,2 ± 48,1 minutos vs. 90,3 ± 42,2 minutos vs. 76,6 ± 37,7 minutos; p < 0,01) e de fluoroscopia (31,3 ± 9,6 minutos vs. 25,4 ± 8,7 minutos vs. 17,2 ± 6,2 minutos; p = 0,01), e no ...


Background: Transcatheter aortic valve implantation (TAVI) is an alternative treatment for high-risk or inoperable patients with aortic stenosis. The multidisciplinary team must undergo specific training and accumulate experience to achieve optimal results. However, its learning curve is not well established. Our objective was to investigate the impact of learning curve on patient selection, technical aspects and clinical outcomes of TAVI. Methods: Observational, prospective analysis of the first 150 patients undergoing transfemoral TAVI between January 2009 and December 2013. Patients were divided into tertiles (n = 50), according to the procedure date. Outcomes were defined according to Valve Academic Research Consortium-2 (VARC-2) criteria. Results: Mean age was 82.5 ± 6.7 years, 44% were male and 75% were in NYHA class III/IV. EuroS-CORE (24.2 ± 13% vs. 21.2 ± 10.8% vs. 23.4 ± 14.3%) and STS Score (5.9 ± 2.9% vs. 6.7 ± 4.3% vs. 5.8 ± 3.1%) were similar between groups. A gradual decrease was observed in procedure times (107.2 ± 48.1 minutes vs. 90.3 ± 42.2 minutes vs. 76.6 ± 37.7 minutes; p < 0.01), fluoroscopy times (31.3 ± 9,6 minutes vs. 25.4 ± 8.7 minutes vs. 17.2 ± 6.2 minutes; p = 0.01) and contrast volume (145.5 ± 70.9 mL vs. 123.2 ± 87.8 mL vs. 101.1 ± 50 mL; p = 0.01). Mortality decreased gradually (20% vs. 10% vs. 4%; p = 0,047), and lower bleeding and moderate-to-severe aortic regurgitation were ...

20.
Rev. bras. cardiol. invasiva ; 22(3): 233-239, Jul-Sep/2014. tab, graf
Artigo em Português | LILACS-Express | LILACS, SES-SP | ID: lil-732787

RESUMO

Introdução: O OPTIMIZE constituiu um estudo prospectivo conduzido em 33 centros no Brasil, que randomizou pacientes para receber terapia antiplaquetária dupla por 3 ou 12 meses, após o implante de stents com eluição de zotarolimus. Nosso propósito foi avaliar os resultados dos pacientes tratados no Instituto Dante Pazzanese de Cardiologia e, posteriormente, compará-los aos de outros centros envolvidos do estudo. Métodos: Foram incluídos pacientes com angina estável ou síndrome coronariana aguda de baixo risco. O objetivo primário foi avaliar a incidência de eventos clínicos e cerebrais adversos, uma combinação de morte por qualquer causa, infarto agudo do miocárdio, acidente vascular encefálico ou sangramento maior aos 12 meses. Resultados: Entre abril de 2010 e março de 2012, incluímos 624 (20%) pacientes no OPTIMIZE. Aos 12 meses, não houve diferença significativa entre os grupos (3 vs. 12 meses de terapia antiplaquetária dupla) quanto à incidência de eventos clínicos e cerebrais adversos (3,8% vs. 6,7%; p = 0,15), eventos cardíacos adversos maiores (6,7% vs. 7,1%; p > 0,99) e nem de trombose do stent (0 vs. 1,3%; p = 0,12). O teste de heterogeneidade mostrou que a variabilidade observada nos resultados do Instituto Dante Pazzanese e dos outros centros não foi maior que a esperada para ocorrer por acaso ( p = 0,064). Conclusões : Nos pacientes ...


Background: OPTIMIZE was a prospective study conducted in 33 Brazilian sites that randomized patients to receive dual antiplatelet therapy for 3 or 12 months after zotarolimus eluting stent implantation. Our objective was to evaluate the outcomes of patients treated at Instituto Dante Pazzanese de Cardiologia and compare them to the outcomes of patients from other participating study sites. Methods: Patients with stable angina or low risk acute coronary syndrome were included in the study. The primary outcome was the incidence of adverse clinical and cerebral events, a composite of all cause of death, myocardial infarction, stroke, or major bleeding at 12 months. Results: Between April/2010 and March/2012, we included 624 (20%) patients in the OPTIMIZE study. At 12 months, there was no significant difference between groups (3 vs. 12 months of dual antiplatelet therapy) for net adverse clinical and cerebral events (3.8% vs. 6.7%; p = 0.15), major adverse cardiac events (6.7% vs. 7.1; p > 0.99) or stent thrombosis (0 vs. 1.3%; p = 0.12). The heterogeneity test showed that the variability observed in the results of Instituto Dante Pazzanese de Cardiologia and in the remaining sites was not greater than the expected to occur by chance (p = 0.064). Conclusions: In patients treated at Instituto Dante Pazzanese de Cardiologia, 3 months of dual antiplatelet therapy was not inferior to 12 months of therapy for the occurrence of net adverse clinical ...

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA