Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Food Chem ; 400: 134014, 2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36084587

RESUMO

This study evaluates the use of paper spray ionization mass spectrometry (PSI-MS) for rapid determination of bisphenol A (BPA) and bisphenol S (BPS) in UHT milk and milk packaging. The packages were analyzed by cutting the cartons into triangular shapes and submitting them to PSI-MS analysis. The milk samples were subjected to a simple liquid-liquid extraction and the supernatant was deposited onto a triangular paper that was subsequently used for PSI-MS analysis. In milk, BPS and BPA levels ranged from 60.0 to 150.8 ng mL-1. The LOD and LOQ values were 1.5 and 4.8 ng mL-1 for BPA, and 4.8 and 16.0 ng mL-1 for BPS, respectively. Linearity was R2 > 0.98 for both compounds. Precision values were below 20%, and recoveries close to 100%. The PSI-MS can be used as a simple, rapid, and accurate methodology to determine bisphenols in milk and milk packaging.


Assuntos
Leite , Espectrometria de Massas em Tandem , Animais , Compostos Benzidrílicos/análise , Leite/química , Fenóis/análise , Sulfonas
2.
Environ Sci Pollut Res Int ; 28(40): 57288-57296, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34089157

RESUMO

Concerns about human health regarding the large use of bisphenol A in thermal papers have led to its replacement by bisphenol S. Analyses of bisphenols require several sample pretreatment steps, which are laborious, expensive, and time-consuming. A paper spray ionization mass spectrometry (PSI-MS) was developed to detect and quantify bisphenol S in three different brands of thermal papers commercially available. Parameters such as paper size, and paper position relative to the mass spectrometer inlet were evaluated. The analyses were performed in selected ion monitoring mode on a linear ion trap mass spectrometer. The developed method presented absolute recovery values ranging from 92.2 to 109.04%, accuracy values from -1.2 to 9.0%, and inter assay precision from 1.8 to 5.6% and enabled LOD as low as 5 ng g-1. The concentration of bisphenol S in all of the three brands of BPA-free thermal papers evaluated ranged from 1.36 to 6.77 µg g-1, and the concentrarion of BPA ranged from 6.56 to 16.4 µg g-1 in all samples of thermal paper evaluated. The PSI-MS method described here was comparable to the conventional ones, such as liquid chromatography coupled with mass spectrometry and gas chromatography coupled with mass spectrometry described in the literature. The present study proved to be practical, fast, and efficient for the direct determination of bisphenol S in thermal papers. Furthermore, the methodology here described showed to be a promising alternative to replace the classical methods for determination of bisphenol S, due to its simplicity, and no needing of any sample pretreatment.


Assuntos
Papel , Espectrometria de Massas em Tandem , Compostos Benzidrílicos/análise , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Fenóis , Sulfonas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA