Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Nanomaterials (Basel) ; 10(2)2020 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-32045986

RESUMO

In this work, we performed a systematic study on the effect of the geometry of pre-patterned templates and spin-coating conditions on the self-assembling process of colloidal nanospheres. To achieve this goal, large-scale templates, with different size and shape, were generated by direct laser-writer lithography over square millimetre areas. When deposited over patterned templates, the ordering dynamics of the self-assembled nanospheres exhibits an inverse trend with respect to that observed for the maximisation of the correlation length ξ on a flat surface. Furthermore, the self-assembly process was found to be strongly dependent on the height (H) of the template sidewalls. In particular, we observed that, when H is 0.6 times the nanospheres diameter and spinning speed 2500 rpm, the formation of a confined and well ordered monolayer is promoted. To unveil the defects generation inside the templates, a systematic assessment of the directed self-assembly quality was performed by a novel method based on Delaunay triangulation. As a result of this study, we found that, in the best deposition conditions, the self-assembly process leads to well-ordered monolayer that extended for tens of micrometres within the linear templates, where 96.2% of them is aligned with the template sidewalls.

2.
ACS Appl Mater Interfaces ; 12(6): 7777-7787, 2020 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-31967449

RESUMO

The orientation of block copolymer (BCP) features in thin films can be obtained by spin-coating a BCP solution on a substrate surface functionalized by a polymer brush layer of the appropriate random copolymer (RCP). Although this approach is well established, little work reporting the amount and distribution of residual solvent in the polymer film after the spin-coating process is available. Moreover, no information can be found on the effect of trapped solvent on the interface between the BCP film and RCP brush. In this work, systems consisting of poly(styrene)-b-poly(methyl methacrylate) thin films deposited on poly(styrene-r-methyl methacrylate) brush layers are investigated by combining neutron reflectivity (NR) experiments with simulation techniques. An increase in the amount of trapped solvent is observed by NR as the BCP film thickness increases accompanied by a significant decrease of the interpenetration length between the BCP and RCP, thus suggesting that the interpenetration between grafted chains and block copolymer chains is hampered by the solvent. Hybrid particle-field molecular dynamics simulations of the analyzed system confirm the experimental observations and demonstrate a clear correlation between the interpenetration length and the amount of trapped solvent.

3.
RSC Adv ; 10(25): 14958-14964, 2020 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35497145

RESUMO

Photonic crystals are a unique tool to modify the photoluminescence of light-emitting materials. A variety of optical effects have been demonstrated by infiltrating opaline structures with photoactive media. On the other hand, the fabrication of such structures includes complex infiltration steps, that often affect the opal lattice and decrease the efficiency of light emission control. In this work, silica nanospheres were directly functionalized with rhodamine B to create an emitting shell around the dielectric core. Simple tuning of the microsphere preparation conditions allows selecting the appropriate sphere diameter and polydispersity index approaching 5%. These characteristics allow facile self-assembling of the nanospheres into three-dimensional photonic crystals whose peculiar density of photonic states at the band-gap edges induces spectral redistribution of the rhodamine B photoluminescence. The possibility to employ the new stable structure as sensor is also investigated. As a proof of principle, we report the variation of light emission obtained by exposure of the opal to vapor of chlorobenzene.

4.
Sci Rep ; 9(1): 15782, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31673007

RESUMO

Magnetic materials in sample preparation for shotgun phosphoproteomics offer several advantages over conventional systems, as the enrichment can be achieved directly in solution, but they still suffer from some drawbacks, due to limited stability and selectivity, which is supposed to be affected by the hydrophilicity of the polymeric supports used for cation immobilization. The paper describes the development of an improved magnetic material with increased stability, thanks to a two-step covering of the magnetic core, for the enrichment of phosphopeptides in biological samples. Four materials were prepared featuring a polymeric shell with tunable hydrophilicity, obtained by "grafting from" polymerization of glycidyl methacrylate with 0-8.3% of polyethylene glycol methacrylate (PEGMA), the latter used to modulate the hydrophilicity of the material surface. Finally, the materials were functionalized with iminodiacetic acid for Ti4+ ion immobilization. The materials were analyzed for their composition by a combination of CHN elemental analysis and thermogravimetric analysis, also hyphenated to gas chromatography and mass spectrometric detection. Surface characteristics were evaluated by water contact angle measurements, scanning electron microscopy and energy dispersive X-ray spectrometry. These materials were applied to the enrichment of phosphopeptides from yeast protein digests. Peptides were identified by proteomics techniques using nano-high performance liquid chromatography coupled to mass spectrometry and bioinformatics. Qualitatively the peptides identified by the four systems were comparable, with 1606-1693 phosphopeptide identifications and a selectivity of 47-54% for all materials. The physico-chemical features of the identified peptides were also the same for the four materials. In particular, the grand average of hydropathy index values indicated that the enriched phosphopeptides were hydrophilic (ca. 90%), and only some co-enriched non-phosphorylated peptides were hydrophobic (21-28%), regardless of the material used for enrichment. Peptides had a pI ≤ 7, which indicated a well-known bias for acidic peptides binding, attributed to the interaction with the metal center itself. The results indicated that the enrichment of phosphopeptides and the co-enrichment of non-phosphorylated peptides is mainly driven by interactions with Ti4+ and does not depend on the amount of PEGMA chains in the polymer shell.

5.
Sci Rep ; 8(1): 11305, 2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30054503

RESUMO

Controlling the location and the distribution of hot spots is a crucial aspect in the fabrication of surface-enhanced Raman spectroscopy (SERS) substrates for bio-analytical applications. The choice of a suitable method to tailor the dimensions and the position of plasmonic nanostructures becomes fundamental to provide SERS substrates with significant signal enhancement, homogeneity and reproducibility. In the present work, we studied the influence of the long-range ordering of different flexible gold-coated Si nanowires arrays on the SERS activity. The substrates are made by nanosphere lithography and metal-assisted chemical etching. The degree of order is quantitatively evaluated through the correlation length (ξ) as a function of the nanosphere spin-coating speed. Our findings showed a linear increase of the SERS signal for increasing values of ξ, coherently with a more ordered and dense distribution of hot spots on the surface. The substrate with the largest ξ of 1100 nm showed an enhancement factor of 2.6 · 103 and remarkable homogeneity over square-millimetres area. The variability of the signal across the substrate was also investigated by means of a 2D chemical imaging approach and a standard methodology for its practical calculation is proposed for a coherent comparison among the data reported in literature.

6.
ACS Nano ; 12(7): 7076-7085, 2018 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-29952543

RESUMO

We investigated the dewetting process on flat and chemically patterned surfaces of ultrathin films (thickness between 2 and 15 nm) of a cylinder forming polystyrene- block-poly(methyl methacrylate) (PS- b-PMMA) spin coated on poly(styrene- r-methyl methacrylate) random copolymers (RCPs). When the PS- b-PMMA film dewets on a 2 nm-thick RCP layer, the ordering of the hexagonally packed PMMA cylinders in the dewetted structures extends over distances far exceeding the correlation length obtained in continuous block copolymer (BCP) films. As a result, micrometer-sized circular droplets featuring defectless single grains of self-assembled PS- b-PMMA with PMMA cylinders perpendicularly oriented with respect to the substrate are generated and randomly distributed on the substrate. Additionally, alignment of the droplets along micrometric lines was achieved by performing the dewetting process on large-scale chemically patterned stripes of 2 nm thick RCP films by laser lithography. By properly adjusting the periodicity of the chemical pattern, it was possible to tune and select the geometrical characteristics of the dewetted droplets in terms of maximum thickness, contact angle and diameter while maintaining the defectless single grain perpendicular cylinder morphology of the circular droplets.

7.
Anal Bioanal Chem ; 410(3): 1177-1185, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29318361

RESUMO

The work describes the development of an enrichment method for the analysis of endogenous phosphopeptides in serum. Endogenous peptides can play significant biological roles, and some of them could be exploited as future biomarkers. In this context, blood is one of the most useful biofluids for screening, but a systematic investigation of the endogenous peptides, especially phosphorylated ones, is still lacking, mainly due to the lack of suitable analytical methods. Thus, in this paper, different phosphopeptide enrichment strategies were pursued, based either on metal oxide affinity chromatography (MOAC, in the form of commercial TiO2 spin columns or magnetic graphitized carbon black-TiO2 composite), or on immobilized metal ion affinity chromatography (IMAC, in the form of Ti4+-IMAC magnetic material or commercial Fe3+-IMAC spin columns). While MOAC strategies proved completely unsuccessful, probably due to interfering phospholipids displacing phosphopeptides, the IMAC materials performed very well. Different sample preparation strategies were tested, comprising direct dilution with the loading buffer, organic solvent precipitation, and lipid removal from the matrix, as well as the addition of phosphatase inhibitors during sample handling for maximized endogenous phosphopeptide enrichment. All data were acquired by a shotgun peptidomics approach, in which peptide samples were separated by reversed-phase nanoHPLC hyphenated with high-resolution tandem mass spectrometry. The devised method allowed the identification of 176 endogenous phosphopeptides in fresh serum added with inhibitors by the direct dilution protocol and the Ti4+-IMAC magnetic material enrichment, but good results could also be obtained from the commercial Fe3+-IMAC spin column adapted to the batch enrichment protocol.


Assuntos
Cromatografia de Afinidade/métodos , Fosfopeptídeos/sangue , Extração em Fase Sólida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Humanos , Magnetismo/métodos , Imãs/química , Fosfopeptídeos/análise , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Titânio/química
8.
ACS Nano ; 12(1): 178-186, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29202227

RESUMO

An effective bottom-up technology for precisely controlling the amount of dopant atoms tethered on silicon substrates is presented. Polystyrene and poly(methyl methacrylate) polymers with narrow molecular weight distribution and end-terminated with a P-containing moiety were synthesized with different molar mass. The polymers were spin coated and subsequently end-grafted onto nondeglazed silicon substrates. P atoms were bonded to the surface during the grafting reaction, and their surface density was set by the polymer molar mass, according to the self-limiting nature of the "grafting to" reaction. Polymeric material was removed by O2 plasma hashing without affecting the tethered P-containing moieties on the surface. Repeated cycles of polymer grafting followed by plasma hashing led to a cumulative increase, at constant steps, in the dose of P atoms grafted to the silicon surface. P injection in the silicon substrate was promoted and precisely controlled by high-temperature thermal treatments. Sheet resistance measurements demonstrated effective doping of silicon substrate.

9.
Talanta ; 178: 274-281, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136822

RESUMO

The work describes the preparation of a new magnetic phase for batch enrichment of phosphopeptides. The material exploits the advantages of magnetic solid phase extraction and couples them with the most employed approach for phosphopeptide enrichment, i.e. Ti4+-IMAC. In order to immobilize Ti4+ ions on the surface of the magnetite nanoparticles, they were first covered by a silica shell and then modified to expose at the surface bromine containing groups. Glycidyl methacrylate was subsequently polymerized from these groups using the "grafting from" approach by the activator regenerated by electron transfer-atom transfer radical polymerization (ARGET-ATRP) technique. Finally, the glycidyl groups were reacted with iminodiacetic acid to functionalize the material with moieties suitable for coordination. The prepared material was extensively characterized and subsequently tested for enrichment of a bovine serum albumin mixture with casein to ascertain its potential. With positive results, the new magnetic polymeric material was further employed to set up an enrichment method on yeast protein digest based on shotgun proteomics. The sample to phase ratio was optimized and the best condition compared to a commercial TiO2 spin column. At the end of the comparison, the new material proved better and could enrich a larger total number of phosphopeptides with increased selectivity. All these conclusions and the test performed on a real complex sample within the final shotgun application further support the applicability of the new material in phosphopeptide analysis of real matrices.


Assuntos
Cromatografia de Afinidade/métodos , Nanopartículas de Magnetita/química , Fosfopeptídeos/química , Polímeros/química , Titânio/química , Animais , Bovinos , Compostos de Epóxi/química , Iminoácidos/química , Metacrilatos/química , Fosfopeptídeos/metabolismo , Proteômica , Soroalbumina Bovina/química , Dióxido de Silício/química
10.
ACS Appl Mater Interfaces ; 9(18): 15685-15697, 2017 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-28397488

RESUMO

The self-assembly (SA) of diblock copolymers (DBCs) based on phase separation into different morphologies of small and high-density features is widely investigated as a patterning and nanofabrication technique. The integration of conventional top-down approaches with the bottom-up SA of DBCs enables the possibility to address the gap in nanostructured lateral length standards for nanometrology, consequently supporting miniaturization processes in device fabrication. On this topic, we studied the pattern characteristic dimensions (i.e., center-to-center distance L0 and diameter D) of a cylinder-forming polystyrene-b-poly( methyl methacrylate) PS-b-PMMA (54 kg mol-1, styrene fraction 70%) DBC when confined within periodic SiO2 trenches of different widths (W, ranging between 75 and 600 nm) and fixed length (l, 5.7 µm). The characteristic dimensions of the PMMA cylinder structure in the confined configurations were compared with those obtained on a flat surface (L0 = 27.8 ± 0.5 nm, D = 13.0 ± 1.0 nm). The analysis of D as a function of W evolution indicates that the eccentricity of the PMMA cylinders decreases as a result of the deformation of the cylinder in the direction perpendicular to the trenches. The center-to-center distance in the direction parallel to the long side of the trenches (L0l) is equal to L0 measured on the flat surface, whereas the one along the short side (L0w) is subjected to an appreciable variation (ΔL0w = 5 nm) depending on W. The possibility of finely tuning L0w maintaining constant L0l paves the way to the realization of a DBC-based transfer standard for lateral length calibration with periods in the critical range between 20 and 50 nm wherein no commercial transfer standards are available. A prototype transfer standard with cylindrical holes was used to calibrate the linear correction factor c(Δx')xx' of an atomic force microscope for a scan length of Δx' = 1 µm. The relative standard uncertainty of the correction factor was only 1.3%, and the second-order nonlinear correction was found to be significant.

11.
ACS Appl Mater Interfaces ; 9(37): 31215-31223, 2017 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-28195457

RESUMO

Block copolymers (BCPs) are emerging as a cost-effective nanofabrication tool to complement conventional optical lithography because they self-assemble in highly ordered polymeric templates with well-defined sub-20-nm periodic features. In this context, cylinder-forming polystyrene-block-poly(methyl methacrylate) BCPs are revealed as an interesting material of choice because the orientation of the nanostructures with respect to the underlying substrate can be effectively controlled by a poly(styrene-random-methyl methacrylate) random copolymer (RCP) brush layer grafted to the substrate prior to BCP deposition. In this work, we investigate the self-assembly process and lateral order evolution in RCP + BCP systems consisting of cylinder-forming PS-b-PMMA (67 kg mol-1, PS fraction of ∼70%) films with thicknesses of 30, 70, 100, and 130 nm deposited on RCP brush layers having thicknesses ranging from 2 to 20 nm. The self-assembly process is promoted by a rapid thermal processing machine operating at 250 °C for 300 s. The level of lateral order is determined by measuring the correlation length (ξ) in the self-assembled BCP films. Moreover, the amount of solvent (Φ) retained in the RCP + BCP systems is measured as a function of the thicknesses of the RCP and BCP layers, respectively. In the 30-nm-thick BCP films, an increase in Φ as a function of the thickness of the RCP brush layer significantly affects the self-assembly kinetics and the final extent of the lateral order in the BCP films. Conversely, no significant variations of ξ are observed in the 70-, 100-, and 130-nm-thick BCP films with increasing Φ.

12.
ACS Appl Mater Interfaces ; 8(15): 9897-908, 2016 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-27020526

RESUMO

Block copolymer (BCP) self-assembly is expected to complement conventional optical lithography for the fabrication of next-generation microelectronic devices. In this regard, silicon-containing BCPs with a high Flory-Huggins interaction parameter (χ) are extremely appealing because they form high-resolution nanostructures with characteristic dimensions below 10 nm. However, due to their slow self-assembly kinetics and low thermal stability, these silicon-containing high-χ BCPs are usually processed by solvent vapor annealing or in solvent-rich ambient at a low annealing temperature, significantly increasing the complexity of the facilities and of the procedures. In this work, the self-assembly of cylinder-forming polystyrene-block-poly(dimethylsiloxane-random-vinylmethylsiloxane) (PS-b-P(DMS-r-VMS)) BCP on flat substrates is promoted by means of a simple thermal treatment at high temperatures. Homogeneous PS-b-P(DMS-r-VMS) thin films covering the entire sample surface are obtained without any evidence of dewetting phenomena. The BCP arranges in a single layer of cylindrical P(DMS-r-VMS) nanostructures parallel-oriented with respect to the substrate. By properly adjusting the surface functionalization, the heating rate, the annealing temperature, and the processing time, one can obtain correlation length values larger than 1 µm in a time scale fully compatible with the stringent requirements of the microelectronic industry.

13.
ACS Appl Mater Interfaces ; 8(12): 8280-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26959626

RESUMO

The self-assembly of block copolymer (BCP) thin films produces dense and ordered nanostructures. Their exploitation as templates for nanolithography requires the capability to control the lateral order of the nanodomains. Among a multiplicity of polymers, the widely studied all-organic polystyrene-block-poly(methyl methacrylate) (PS-b-PMMA) BCP can easily form nanodomains perpendicularly oriented with respect to the substrate, since the weakly unbalanced surface interactions are effectively neutralized by grafting to the substrate an appropriate poly(styrene-random-methyl methacrylate) P(S-r-MMA) random copolymer (RCP). This benefit along with the selective etching of the PMMA component and the chemical similarity with the standard photoresist materials deserved for PS-b-PMMA the role of BCP of choice for the technological implementation in nanolithography. This work demonstrates that the synergic effect of thermal annealing with the initial solvent naturally trapped in the basic RCP + BCP system after the deposition process can be exploited to enhance the lateral order. The solvent content embedded in the total RCP + BCP system can be tuned by changing the molecular weight and thus the thickness of the grafted RCP brush layer, without introducing external reservoirs or dedicated setup and/or systems. The appropriate supply of solvent supports a grain coarsening kinetics following a power law with a 1/3 growth exponent for standing hexagonally ordered cylinders.

14.
Anal Bioanal Chem ; 408(12): 3155-63, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26873220

RESUMO

In the present paper, a reliable and rugged thermogravimetry-gas chromatography-mass spectrometry (TGA-GC-MS) method was developed to determine the composition of ultrathin films consisting of binary blends of functional polystyrene (PS) and polymethylmethacrylate (PMMA) grafted to a silicon wafer. A general methodology will be given to address the composition determination problem for binary or even multicomponent polymer brush systems using the PS/PMMA-based samples as a paradigmatic example. In this respect, several distinct tailor-made materials were developed to ensure reliable calibration and validation stages. The analytical method was tested on unknown samples to follow the composition evolution in PS/PMMA brushes during the grafting reaction. A preferential grafting of the PMMA was revealed in full agreement with its preferential interaction with the SiO2 polar surface.

15.
J Inorg Biochem ; 151: 132-42, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26277416

RESUMO

Multilayer fluorescent nonporous silica nanoparticles (SNPs) with an external shell containing primary amino groups were used as delivery systems for Pt(IV) candidate antitumor prodrugs. Spherical SNPs of three different sizes (diameter around 120, 100, and 50 nm) were loaded with two different complexes, namely (OC-6-33)-diamminebis(4-carboxybutanoato)dichloridoplatinum(IV) (1) and (OC-6-44)-diammine(4-carboxybutanoato)dichloridoethanolatoplatinum(IV) (2), through the formation of amide bonds between the pendant amino groups on SNPs and the free carboxylic groups of the complexes. Complex 1 proved to cause heavy and irreversible agglomeration of SNPs; likely, the presence of two reactive carboxylic functionalities induces the formation of cross-links between the amino-decorated SNPs. On the contrary, the conjugates 2-SNP, obtained from the monofunctionalized 2, afforded aqueous nano-suspensions reasonably stable toward aggregation. These solutions showed a limited Pt release in water in the absence of any reducing agents, mainly in form of a Pt(IV) derivative generated by the hydrolysis of the Si-O-Si bond of the functionalized arms attached to silica. In the presence of ascorbic acid, the reduction Pt(IV) → Pt(II) caused the release of the active metabolite cisplatin. Conjugates 2-SNP exhibited much better antiproliferative activity on the Pt-sensitive ovarian A2780 cell line than parent cisplatin and free 2, due to their more efficient cellular uptake.


Assuntos
Portadores de Fármacos/química , Nanopartículas/química , Compostos Organoplatínicos/química , Pró-Fármacos/química , Dióxido de Silício/química , Antineoplásicos/síntese química , Antineoplásicos/química , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Portadores de Fármacos/farmacologia , Feminino , Corantes Fluorescentes/química , Corantes Fluorescentes/farmacologia , Humanos , Concentração Inibidora 50 , Microscopia Eletrônica de Varredura , Compostos Organoplatínicos/síntese química , Compostos Organoplatínicos/farmacologia , Neoplasias Ovarianas/tratamento farmacológico , Pró-Fármacos/farmacologia
16.
ACS Appl Mater Interfaces ; 7(20): 10944-51, 2015 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-25954979

RESUMO

Hydroxyl-terminated P(S-r-MMA) random copolymers (RCPs) with molecular weights (Mn) from 1700 to 69000 and a styrene unit fraction of approximately 61% were grafted onto a silicon oxide surface and subsequently used to study the orientation of nanodomains with respect to the substrate, in cylinder-forming PS-b-PMMA block copolymer (BCP) thin films. When the thickness (H) of the grafted layer is greater than 5-6 nm, a perpendicular orientation is always observed because of the efficient decoupling of the BCP film from the polar SiO2 surface. Conversely, if H is less than 5 nm, the critical thickness of the grafted layer, which allows the neutralization of the substrate and promotion of the perpendicular orientation of the nanodomains in the BCP film, is found to depend on the Mn of the RCP. In particular, when Mn = 1700, a 2.0 nm thick grafted layer is sufficient to promote the perpendicular orientation of the PMMA cylinders in the PS-b-PMMA BCP film. A proximity shielding mechanism of the BCP molecules from the polar substrate surface, driven by chain stretching of the grafted RCP molecules, is proposed.

17.
ACS Appl Mater Interfaces ; 7(7): 3920-30, 2015 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-25664773

RESUMO

Two strategies are envisioned to improve the thermal stability of the grafted layer and to allow the processing of the random copolymer/block copolymer (RCP/BCP) system at high temperature. From one side, a high-temperature thermal treatment of a commercial α-hydroxyl ω-2,2,6,6-tetramethylpiperidinyloxy functional RCP, namely, TR58, leads to the formation of a stabilized layer able to induce the perpendicular orientation of a symmetric BCP to temperatures higher than 310 °C. On the other side, an α-hydroxyl ω-Br functional RCP, namely, BrR58, with the same molar mass and composition of TR58, was prepared by activator regenerated by electron transfer atom transfer radical polymerization. The resulting brush layer can sustain the self-assembly of the symmetric BCP for processing temperatures as high as 330 °C. In both systems, the disruption of the BCP film, deposited on the grafted RCP layer, occurs because of the formation of bubbles, due to a low-temperature evolution of monomers from the RCP layer. The extent of the low-temperature monomer evolution is higher for TR58 than it is for BrR58 and starts at lower temperatures. For both copolymers, the thermal treatment offsets the low-temperature monomer evolution while still maintaining surface characteristics suitable to induce the perpendicular orientation of the BCPs, thus ultimately extending the range of processing temperatures of the BCP film and consequently speeding the self-organization process.

18.
Analyst ; 140(5): 1486-94, 2015 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-25620202

RESUMO

Fouling and passivation are the major drawbacks for a wide applicability of electroanalytical sensors based on nanomaterials, especially in biomedical and environmental fields. The production of highly engineered devices, designed ad hoc for specific applications, is the key factor in the direction of overcoming the problem and accessing effective sensors. Here, the fine-tuning of the system, composed of a highly ordered distribution of silver nanoparticles between a bottom silica and a top titania layer, confers multifunctional properties to the device for a biomedical complex challenge: dopamine detection. The crucial importance of each component towards a robust and efficient electroanalytical system is studied. The total recovery of the electrode performance after a simple UV-A cleaning step (self-cleaning), due to the photoactive interface and the aging resistance, is deeply investigated.


Assuntos
Técnicas Biossensoriais/instrumentação , Dopamina/análise , Eletroquímica/métodos , Eletrodos , Nanopartículas Metálicas/química , Nanotecnologia/instrumentação , Prata/química , Titânio/química , Raios Ultravioleta , Difração de Raios X
19.
PLoS One ; 9(10): e111360, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25356594

RESUMO

Here we describe a prime-boost regimen of vaccination in Macaca fascicularis that combines priming with novel anionic microspheres designed to deliver the biologically active HIV-1 Tat protein and boosting with Tat in Alum. This regimen of immunization modulated the IgG subclass profile and elicited a balanced Th1-Th2 type of humoral and cellular responses. Remarkably, following intravenous challenge with SHIV89.6Pcy243, vaccinees significantly blunted acute viremia, as compared to control monkeys, and this control was associated with significantly lower CD4+ T cell depletion rate during the acute phase of infection and higher ability to resume the CD4+ T cell counts in the post-acute and chronic phases of infection. The long lasting control of viremia was associated with the persistence of high titers anti-Tat antibodies whose profile clearly distinguished vaccinees in controllers and viremics. Controllers, as opposed to vaccinated and viremic cynos, exhibited significantly higher pre-challenge antibody responses to peptides spanning the glutamine-rich and the RGD-integrin-binding regions of Tat. Finally, among vaccinees, titers of anti-Tat IgG1, IgG3 and IgG4 subclasses had a significant association with control of viremia in the acute and post-acute phases of infection. Altogether these findings indicate that the Tat/H1D/Alum regimen of immunization holds promise for next generation vaccines with Tat protein or other proteins for which maintenance of the native conformation and activity are critical for optimal immunogenicity. Our results also provide novel information on the role of anti-Tat responses in the prevention of HIV pathogenesis and for the design of new vaccine candidates.


Assuntos
Vacinas contra a AIDS/imunologia , Síndrome da Imunodeficiência Adquirida/imunologia , Materiais Biocompatíveis/química , Sistemas de Liberação de Medicamentos , Microesferas , Polímeros/química , Produtos do Gene tat do Vírus da Imunodeficiência Humana/imunologia , Síndrome da Imunodeficiência Adquirida/sangue , Síndrome da Imunodeficiência Adquirida/virologia , Animais , Ânions , Formação de Anticorpos/imunologia , Linfócitos T CD4-Positivos/imunologia , Apresentação Cruzada/imunologia , Citocinas/biossíntese , Mapeamento de Epitopos , Imunidade Celular/imunologia , Imunidade Humoral , Imunização , Imunoglobulina G/imunologia , Injeções Intravenosas , Contagem de Linfócitos , Macaca , Masculino , Estatísticas não Paramétricas , Viremia/sangue , Viremia/imunologia
20.
J Chromatogr A ; 1368: 204-10, 2014 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-25311490

RESUMO

Polymeric materials are widely employed to build up tunable nanomasks for nano-patterning technologies. Ultrathin polymer layers are involved in this process. A Thermo Gravimetric Analysis-Mass Spectrometry (TGA-GC-MS) method was optimised, validated and successfully applied to investigate the thermal behavior of ultrathin poly(styrene-r-methylmethacrylate) random copolymer layers P(S-r-MMA) grafted to a silicon wafer surface. The interface between TGA and MS is highly versatile since many instrumental parameters (i.e. loop volumes, pulsed sampling frequencies, acquisition modalities, carrier gases, flow rates) can be easily tuned. Samples featuring substantial scale difference, i.e. bulk materials, thick films (few µm thickness), thin and ultrathin films (few nm thickness) can be analyzed without any instrumental modification or sample pretreatments. The TGA-GC-MS analysis was used to highlight subtle differences in samples featuring different thicknesses, in the 2-6 nm range, and subjected to various thermal treatments, thus indicating that this hyphenated technique could be successfully applied to the investigation of ultrathin polymer films.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Polímeros/química , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Silício , Propriedades de Superfície , Termogravimetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA