RESUMO
PURPOSE: To evaluate the effect of automated tube voltage selection (ATVS) on radiation dose at computed tomography (CT) worldwide encompassing all body regions and types of CT examinations. MATERIALS AND METHODS: No patient information was accessed; therefore, institutional review board approval was not sought. Data from 86 centers across the world were analyzed. All CT interactions were automatically collected and transmitted to the CT vendor during two 6-week periods immediately before and 2 weeks after implementation of ATVS. A total of 164 323 unique CT studies were analyzed. Studies were categorized by body region and type of examination. Tube voltage and volume CT dose index (CTDIvol) were compared between examinations performed with ATVS and those performed before ATVS implementation. Descriptive statistical methods and multilevel linear regression models were used for analysis. RESULTS: Across all types of CT examinations and body regions, CTDIvol was 14.7% lower in examinations performed with ATVS (n = 30 313) than in those performed before ATVS implementation (n = 79 275). Relative reductions in mean CTDIvol were most notable for temporal bone CT (-56.1%), peripheral runoff CT angiography (-48.6%), CT of the paranasal sinus (-39.6%), cerebral or carotid CT angiography (-36.4%), coronary CT angiography (-25.1%), and head CT (-23.9%). An increase in mean CTDIvol was observed for renal stone protocols (26.2%) and thoracic or lumbar spine examinations (6.6%). In the multilevel model with fixed effects ATVS and examination type, and the interaction of these variables and the random effect country, a significant influence on CTDIvol for all fixed efects was revealed (ATVS, P = .0031; examination type, P < .0001; interaction term, P < .0001). CONCLUSION: ATVS significantly reduces radiation dose across most, but not all, body regions and types of CT examinations.
Assuntos
Algoritmos , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Automação , Humanos , Estudos RetrospectivosRESUMO
OBJECTIVES: To perform a systematic review of the growing body of literature evaluating the prognostic value of epicardial fat volume (EFV) quantified by cross-sectional imaging. METHODS: Two independent reviewers performed systematic searches on both PubMed and Scopus using search terms developed with a medical librarian. Peer-reviewed articles were selected based on the inclusion of outcome data, utilization of epicardial fat volume and sufficient reporting for analysis. RESULTS: A total of 411 studies were evaluated with nine studies meeting the inclusion criteria. In all, the studies evaluated 10,252 patients. All nine studies were based on CT measurements. Seven studies evaluated the prognostic value of EFV unadjusted for calcium score, and six of these studies found a significant association between EFV and clinical outcomes. Seven studies evaluated the incremental value of EFV beyond calcium scoring, and six of these studies found a significant association. CONCLUSIONS: The majority of studies suggest that EFV quantification is significantly associated with clinical outcomes and provides incremental prognostic value over coronary artery calcium scoring. Future research should use a binary cutoff of 125 mL for evaluation of EFV to provide consistency with other research. KEY POINTS: ⢠Epicardial fat volume (EFV) has prognostic value for adverse cardiac events ⢠Establishment of standardized quantitative categories for EFV is needed ⢠Quantification of EFV could improve risk assessment with calcium scoring.
Assuntos
Tecido Adiposo/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Medição de Risco , Tomografia Computadorizada por Raios X , Adulto JovemRESUMO
OBJECTIVE: To evaluate the accuracy, reliability and time saving potential of a novel cardiac CT (CCT)-based, automated software for the assessment of segmental left ventricular function compared to visual and manual quantitative assessment of CCT and cardiac magnetic resonance (CMR). METHODS: Forty-seven patients with suspected or known coronary artery disease (CAD) were enrolled in the study. Wall thickening was calculated. Segmental LV wall motion was automatically calculated and shown as a colour-coded polar map. Processing time for each method was recorded. RESULTS: Mean wall thickness in both systolic and diastolic phases on polar map, CCT, and CMR was 9.2 ± 0.1 mm and 14.9 ± 0.2 mm, 8.9 ± 0.1 mm and 14.5 ± 0.1 mm, 8.3 ± 0.1 mm and 13.6 ± 0.1 mm, respectively. Mean wall thickening was 68.4 ± 1.5 %, 64.8 ± 1.4 % and 67.1 ± 1.4 %, respectively. Agreement for the assessment of LV wall motion between CCT, CMR and polar maps was good. Bland-Altman plots and ICC indicated good agreement between CCT, CMR and automated polar maps of the diastolic and systolic segmental wall thickness and thickening. The processing time using polar map was significantly decreased compared with CCT and CMR. CONCLUSION: Automated evaluation of segmental LV function with polar maps provides similar measurements to manual CCT and CMR evaluation, albeit with substantially reduced analysis time. KEY POINTS: ⢠Cardiac computed tomography (CCT) can accurately assess segmental left ventricular wall function. ⢠A novel automated software permits accurate and fast evaluation of wall function. ⢠The software may improve the clinical implementation of segmental functional analysis.
Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica , Reprodutibilidade dos Testes , Estudos RetrospectivosRESUMO
OBJECTIVES: To systematically analyze the influence of technical parameters on quantification of epicardial fat volume (EATV) at cardiac CT. METHODS: 153 routine cardiac CT data sets were analyzed using three-dimensional pericardial border delineation. Three image series were reconstructed per patient: (a) CTAD: coronary CT angiography (CTA), diastolic phase; (b) CTAS: coronary CTA, systolic phase; (c) CaScD: non-contrast CT, diastolic phase. EATV was calculated using three different upper thresholds (-15HU, -30 HU, -45HU). Repeated measures ANOVA, Spearman's rho, and Bland Altman plots were used. RESULTS: Mean EATV differed between all three image series at a -30HU threshold (CTAD 87.2 ± 38.5 ml, CTAS 90.9 ± 37.7 ml, CaScD 130.7 ± 49.5 ml, P<0.001). EATV of diastolic and systolic CTA reconstructions did not differ significantly (P=0.225). Mean EATV for contrast enhanced CTA at a -15HU threshold (CTAD15 102.4 ± 43.6 ml, CTAS15 105.3 ± 42.3 ml) could be approximated most closely by non-contrast CT at -45HU threshold (CaScD45 105.3 ± 40.8 ml). The correlation was excellent: CTAS15-CTAD15, rho=0.943; CTAD15-CaScD45, rho=0.905; CTAS15-CaScD45, rho=0.924; each P<0.001). Bias values from Bland Altman Analysis were: CTAS15-CTAD15, 4.9%; CTAD15-CaScD45, -4.3%; CTAS15-CaScD45, 0.6%. CONCLUSIONS: Measured EATV can differ substantially between contrast enhanced and non-contrast CT studies, which can be reconciled by threshold modification. Heart cycle phase does not significantly influence EATV measurements.
Assuntos
Tecido Adiposo/patologia , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Pericárdio/patologia , Tomografia Computadorizada por Raios X , Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Sístole , Tomografia Computadorizada por Raios X/métodosRESUMO
OBJECTIVE: The purpose of this study was to determine whether ultralow-radiation-dose chest CT can be used for quantification of lung density and for emphysema detection in participants undergoing lung cancer screening. SUBJECTS AND METHODS: Fifty-two patients were prospectively enrolled and underwent scanning twice with low-dose CT (reference parameters, 120 kV, 50 effective mAs) and ultralow-dose CT (reference parameters, 80 kV, 4-5 effective mAs). Images were reconstructed by filtered back projection (FBP) for low-dose CT and FBP and iterative reconstruction (IR) for ultralow-dose CT. Radiation dose was recorded. Image noise, mean lung attenuation, 15th percentile of lung attenuation, and emphysema index were measured in each image series and compared. Test characteristics of ultralow-dose CT in detecting more than subtle emphysema (emphysema index≥3%) were calculated. RESULTS: The effective dose of low-dose CT was 2.1±0.5 mSv, and that of ultralow-dose CT was 0.13±0.04 mSv. Compared with the findings for low-dose CT, absolute overestimation of emphysema index was 7% on ultralow-dose CT images reconstructed with FBP and 2% on those processed with IR. The 15th percentile of lung attenuation was underestimated by 21.3 HU on ultralow-dose FBP images and by 5.8 HU on IR images. No relevant bias was observed for mean lung attenuation. Four patients (8%) had more than subtle emphysema. The emphysema index measured at ultralow-dose CT with FBP and IR had 100% and 100% sensitivity and 92% and 96% specificity in identifying patients with more than subtle emphysema at a cutoff of greater than 12.1% for FBP and greater than 6.7% for IR. CONCLUSION: Ultralow-dose chest CT performed for lung cancer screening can be used for quantification of lung density and for emphysema detection. IR improves the accuracy of ultralow-dose CT in this setting.
Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Enfisema Pulmonar/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Sensibilidade e Especificidade , Fumar/efeitos adversosRESUMO
OBJECTIVES: The present study aimed to determine the feasibility of a novel fractional flow reserve (FFR) algorithm based on coronary CT angiography (cCTA) that permits point-of-care assessment, without data transfer to core laboratories, for the evaluation of potentially ischemia-causing stenoses. METHODS: To obtain CT-based FFR, anatomical coronary information and ventricular mass extracted from cCTA datasets were integrated with haemodynamic parameters. CT-based FFR was assessed for 36 coronary artery stenoses in 28 patients in a blinded fashion and compared to catheter-based FFR. Haemodynamically relevant stenoses were defined by an invasive FFR ≤0.80. Time was measured for the processing of each cCTA dataset and CT-based FFR computation. Assessment of cCTA image quality was performed using a 5-point scale. RESULTS: Mean total time for CT-based FFR determination was 51.9 ± 9.0 min. Per-vessel analysis for the identification of lesion-specific myocardial ischemia demonstrated good correlation (Pearson's product-moment r = 0.74, p < 0.0001) between the prototype CT-based FFR algorithm and invasive FFR. Subjective image quality analysis resulted in a median score of 4 (interquartile ranges, 3-4). CONCLUSIONS: Our initial data suggest that the CT-based FFR method for the detection of haemodynamically significant stenoses evaluated in the selected population correlates well with invasive FFR and renders time-efficient point-of-care assessment possible. KEY POINTS: ⢠CT-based FFR computation is a promising novel non-invasive application. ⢠A novel prototype algorithm permits time-efficient point-of-care CT-based FFR assessment. ⢠Initial results of the CT-based FFR prototype algorithm compare favourably with FFR.
Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , SesquiterpenosAssuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Tomografia Computadorizada por Raios X , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de DoençaRESUMO
BACKGROUND: Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. PURPOSE: To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. MATERIAL AND METHODS: A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. RESULTS: The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). CONCLUSION: Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp.
Assuntos
Angiografia/métodos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto JovemRESUMO
The aim of the study is to describe the spectrum of indications for pediatric ECG-synchronized CT angiography (CTA), the main determinants of radiation exposure, and trends in radiation dose over time at a single, tertiary referral center. The study was IRB approved and HIPAA compliant with informed consent waived. Between 2005 and 2013, 324 pediatric patients underwent ECG-synchronized CTA to evaluate known or suspected cardiovascular abnormalities (109 female, median age 8.1 years). The effective dose (ED) was calculated using age-specific correction factors. Univariate and multivariate regression analyses were performed to identify predictors of radiation dose. The most common primary indications for the CTA examinations included known or suspected coronary pathologies (n = 166), complex congenital heart disease (n = 73), and aortic pathologies (n = 41). Median radiation exposure decreased from 12 mSv for patients examined in the years 2005-2007 to 1.2 mSv for patients examined in the years 2011-2013 (p < 0.001). Patients scanned using a tube potential of 80 kV (n = 259) had a significantly lower median radiation dose (1.4 mSv) compared to patients who were scanned at 100 kV (n = 46, median 6.3 mSv) or 120 kV (n = 19, median 19 mSv, p < 0.001). Tube voltage, followed by tube current and the method of ECG-synchronization were the strongest independent predictors of radiation dose. Growing experience with dose-saving techniques and CTA protocols tailored to the pediatric population have led to a tenfold reduction in radiation dose over recent years and now allow routinely performing ECG-synchronized CTA in children with a radiation dose on the order of 1 mSv.
Assuntos
Envelhecimento , Angiografia/efeitos adversos , Eletrocardiografia/efeitos adversos , Cardiopatias Congênitas/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Angiografia/métodos , Técnicas de Imagem de Sincronização Cardíaca/efeitos adversos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Eletrocardiografia/métodos , Feminino , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente , Recém-Nascido , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodosRESUMO
The purpose of this article is to evaluate image quality and radiation dose of prospectively electrocardiogram (ECG)-triggered high-pitch coronary computed tomography angiography (CCTA) at 70 kVp and 30 mL contrast medium.One hundred fifty patients with a heart rate ≤70 beats per minute (bpm) underwent CCTA using a second-generation dual-source computed tomography (CT) scanner and were randomized into 3 groups according to tube voltage and contrast medium volume (370 mg/mL iodine concentration) (100 kVp group, 100 kVp/60 mL, n = 55; 80 kVp group, 80 kVp/60 mL, n = 44; 70 kVp group, 70 kVp/30 mL, n = 51). Objective and subjective image quality along with the effect of heart rate (HR) and body mass index (BMI) was evaluated and compared between the groups. Radiation dose was estimated for each patient.CT attenuation and image noise were higher in the 80 and 70 kVp groups than in the 100 kVp group (all P < 0.001). Signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were lower in the 70 kVp group than in the 80 and 100 kVp groups (all P < 0.05). There was no difference for subjective image quality between the groups (P > 0.05). HR did not affect subjective image quality (all P > 0.05), while patients with BMI <23 kg/m had higher image quality than patients with BMI ≥23 kg/m (P < 0.05). Compared with the 100 kVp group, the radiation dose of the 70 kVp group was reduced by 75%.In conclusion, prospectively ECG-triggered high-pitch 70 kVp/30 mL CCTA can obtain diagnostic image quality with lower radiation dose in selected patients with BMI <23 kg/m compared with 80/100 kVp/60 mL CCTA.
Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de RadiaçãoRESUMO
The exact pathophysiology of contrast-induced nephropathy (CIN) is not fully clarified, yet the osmotic characteristics of contrast media (CM) have been a significant focus in many investigations of CIN. Osmotic effects of CM specific to the kidney include transient decreases in blood flow, filtration fraction, and glomerular filtration rate. Potentially significant secondary effects include an osmotically induced diuresis with a concomitant dehydrating effect. Clinical experiences that have compared the occurrence of CIN between the various classes of CM based on osmolality have suggested a much less than anticipated advantage, if any, with a lower osmolality. Recent animal experiments actually suggest that induction of a mild osmotic diuresis in association with iso-osmolar agents tends to offset potentially deleterious renal effects of high viscosity-mediated intratubular CM stagnation.
Assuntos
Meios de Contraste/efeitos adversos , Meios de Contraste/química , Nefropatias/induzido quimicamente , Animais , Humanos , Concentração Osmolar , RatosRESUMO
OBJECTIVES: To evaluate the feasibility, image quality and radiation dose of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) with 30 mL contrast agent at 70 kVp. METHODS: Fifty-eight patients with suspected coronary artery disease, a body mass index (BMI) of less than 25 kg/m(2), sinus rhythm and a heart rate (HR) of less than 70 beats per minute (bpm) were prospectively enrolled in this study. Thirty mL of 370 mg I/mL iodinated contrast agent was administrated at a flow rate of 5 mL/s. All patients underwent prospectively ECG-triggered high-pitch CCTA on a second-generation dual-source CT system at 70 kVp using automated tube current modulation. RESULTS: Fifty-six patients (96.6%) had diagnostic CCTA images and two patients (3.4%) had one vessel with poor image quality each rated as non-diagnostic. No significant effects of HR, HR variability and BMI on CCTA image quality were observed (all P > 0.05). Effective dose was 0.17 ± 0.02 mSv and the size-specific dose estimate was 1.03 ± 0.13 mGy. CONCLUSION: Prospectively ECG-triggered high-pitch CCTA at 70 kVp with 30 mL of contrast agent can provide diagnostic image quality at a radiation dose of less than 0.2 mSv in patients with a BMI of less than 25 kg/m(2) and an HR of less than 70 bpm. KEY POINTS: ⢠Prospectively ECG-triggered high-pitch CCTA at 70 kVp/30 mL contrast agent is feasible. ⢠Diagnostic image quality can be obtained at a radiation dose of less than 0.2 mSv. ⢠This protocol is suitable for normal-weight patients with slow heart rate.
Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia , Iohexol/análogos & derivados , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Injeções Intravenosas , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos TestesRESUMO
UNLABELLED: Transient ischemic dilation (TID) in the setting of abnormal stress-rest cardiac SPECT myocardial perfusion imaging (MPI) has been linked with increased cardiovascular risk. However, the significance of TID in the setting of an otherwise normal SPECT MPI study has not been clearly established. In this study, cardiac CT was used to evaluate the prevalence of atherosclerotic lesions and the severity of coronary artery stenosis in patients with TID of the left ventricle with or without associated myocardial perfusion defects on SPECT MPI. METHODS: The study population consisted of 1,553 consecutive patients who had undergone both cardiac CT and SPECT MPI within 1 mo between January 1, 2006, and September 1, 2011. Patients included in the study group had a pathologic TID value defined as ≥1.18 for men and ≥1.22 for women. Coronary CT angiography was used to evaluate each coronary segment for the presence and composition of atherosclerotic plaque and the degree of coronary stenosis. TID-positive patients were compared with a 2:1 risk-factor-matched-pair control cohort without TID. RESULTS: TID was identified in 30 patients who were compared with TID-negative risk-factor-matched controls (n = 60). When compared with the TID-negative control cohort, TID-positive patients had no significant differences in the presence and extent of atherosclerosis, the degree of coronary artery stenosis, or the calcium score at cardiac CT. Similarly, there were no significant differences in these CT measures in TID-positive patients with a normal perfusion study (n = 20) when compared with TID-negative patients with a normal perfusion study (n = 48). In addition, there was no significant difference in the incidence of major adverse cardiac events when comparing both the TID-positive patients and the TID-negative control cohort and when comparing patients who were TID-positive with normal perfusion with patients who were TID-negative with normal perfusion. CONCLUSION: The presence of TID with an otherwise normal SPECT MPI study does not translate into a greater extent of coronary artery disease as assessed by cardiac CT or increased risk for future major adverse cardiac events.
Assuntos
Angiografia Coronária , Ventrículos do Coração/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de TempoRESUMO
OBJECTIVES: This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). METHODS: cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFVM segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFVA calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. RESULTS: The final EFVA (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). CONCLUSIONS: Automated EFVA quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. KEY POINTS: ⢠Manual epicardial fat volume quantification correlates with risk factors but is time-consuming. ⢠The novel software prototype automates measurement of epicardial fat volume with good accuracy. ⢠This novel approach is less time-consuming and could be incorporated into clinical workflow.
Assuntos
Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Design de SoftwareRESUMO
BACKGROUND: Congenital heart diseases (CHDs) are sometimes associated with coronary artery anomalies (CAAs). Accurate preoperative evaluation of coronary artery anatomy is essential for successful surgical repair of complex CHD. OBJECTIVE: The aim of this study was to evaluate the incidence of congenital CAAs in patients with complex CHD at dual-source CT. METHODS: Four hundred seventeen consecutive patients with complex CHD underwent contrast-enhanced cardiac CT angiography. The results were retrospectively analyzed, including the types and incidences of CAAs in various forms of complex CHD. Each patient was analyzed independently by 2 experienced cardiovascular radiologists. Image quality of coronary arteries was assessed on a 5-point scale with 2 or less being nondiagnostic. RESULTS: Thirty-five of 417 studies were nondiagnostic (8.39%). Sixty-three cases of CAA (15.11%) were detected by anomalous ostia and coronary arteries. CAA was involved in 6 of 108 patients with tetralogy of Fallot (5.56%), 18 of 84 patients with double outlet right ventricle (21.43%), 11 of 97 patients with pulmonary artery atresia (11.34%), 7 of 36 patients with transposition of the great arteries (22.22%), 15 of 41 patients with single ventricle (36.59%), 4 of 12 patients with truncus arteriosus/aortopulmonary window (33.33%), and 2 of 39 patients with interruption of the aortic arch/coarctation of the aorta (5.13%). Twenty of these were accompanied with an anomalous coronary course (31.74%). CONCLUSION: Patients with complex CHD have a higher prevalence of CAAs, which should be considered before surgery. Dual-source CT is an effective technique to visualize and evaluate complex CHD.