Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Indian Dermatol Online J ; 10(6): 714-716, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31807456

RESUMO

Adult Onset Xanthogranulomatous Disease represents an umbrella term encompassing 4 distinct entities with partially overlapping clinicopathological features: adult-onset xanthogranuloma, adult-onset asthma with periocular xanthogranuloma, Erdheim-Chester disease, and necrobiotic xanthogranuloma. They are characterized by a predilection to affect the orbit and ocular adnexa and special histopathological features, in particular infiltrates comprising non-Langerhans-derived foamy histiocytes and Touton giant cells. The appearance of the eyelid lesions is virtually diagnostic, producing readily recognisable diffuse, yellow plaques. Affected patients should be investigated and reviewed regularly for systemic disease. We would like to present a case of 35-year-old male patient with Adult-onset xanthogranulomatous disease [AOXG] associated with vitiligo. This case is reported for its rarity.

2.
Lab Chip ; 17(9): 1570-1577, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28357424

RESUMO

Label-free biodetection schemes compatible with standard CMOS fabrication methods constitute an important goal, as these are enabling tools for the mass production of high-sensitivity biosensors. Two-dimensional slab photonic crystal (2D slab-PhC) sensors have been posited as ultrahigh-sensitivity detection components, but to date recognition-mediated detection of viruses or simulants under flow has not been demonstrated. We report the design and optimization of a new W1 waveguide-coupled 2D slab-PhC sensor, with a geometry well suited to virus detection. Proof of concept experiments with fluorescent latex particles verified that the sensor could respond to infiltration of a single particle, both in air and under an aqueous cover layer. Subsequent experiments with antibody-functionalized sensors and virus simulants confirmed the ability of the device to detect virus-sized particles under flow via a recognition-mediated process. This work sets the stage for incorporation of 2D slab-PhC sensors into fully integrated photonic sensor systems.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Óptica e Fotônica/instrumentação , Vírus/isolamento & purificação , Anticorpos Antivirais/metabolismo , Humanos , Vírus/metabolismo
3.
Indian Dermatol Online J ; 6(1): 17-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25657911

RESUMO

BACKGROUND: Finasteride acts by reducing dihydrotestosterone levels, thereby inhibiting miniaturization of hair follicles in patients with androgenetic alopecia (AGA). Oral finasteride is associated with side effects such as decreased libido, sexual dysfunction, and gynecomastia. AIM: The aim of the following study is to assess the efficacy of maintaining hair growth with 5% topical minoxidil fortified with 0.1% finasteride in patients with AGA after initial treatment with 5% topical minoxidil and oral finasteride for two years. MATERIALS AND METHODS: A retrospective assessment was done in 50 male patients aged 20-40 years with AGA. All the patients had been initially treated with topical minoxidil and oral finasteride for a period of two years, after which the oral finasteride was replaced with topical minoxidil fortified with finasteride. Five of 50 patients had discontinued the treatment for a period of 8-12 months and were then resumed with only topical minoxidil fortified with finasteride. The patients' case sheets and photographs were reviewed by independent observers and the efficacy of minoxidil-finasteride combination was assessed. RESULTS: Of the 45 patients who underwent a continuous treatment for AGA, 84.44% maintained a good hair density with topical minoxidil-finasteride combinatio. Of the five patients who discontinued oral finasteride for 8-12 months, four demonstrated good improvement in hair density when treatment was resumed with topical minoxidil-finasteride combination. CONCLUSION: Topical finasteride can be considered for hair density maintenance after initial improvement with oral finasteride, thereby obviating the indefinite use of oral finasteride.

4.
Lab Chip ; 15(4): 971-990, 2015 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-25563402

RESUMO

Photonic crystals - optical devices able to respond to changes in the refractive index of a small volume of space - are an emerging class of label-free chemical- and bio-sensors. This review focuses on one class of photonic crystal, in which light is confined to a patterned planar material layer of sub-wavelength thickness. These devices are small (on the order of tens to hundreds of microns square), suitable for incorporation into lab-on-a-chip systems, and in theory can provide exceptional sensitivity. We introduce the defining characteristics and basic operation of two-dimensional photonic crystal sensors, describe variations of their basic design geometry, and summarize reported detection results from chemical and biological sensing experiments.


Assuntos
Técnicas Biossensoriais/instrumentação , Dispositivos Lab-On-A-Chip , Dispositivos Ópticos , Fótons , Cristalização , Luz
5.
J Cutan Aesthet Surg ; 7(2): 93-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25136209

RESUMO

BACKGROUND: Various treatment modalities including non-invasive methods such as chemical peels, topical retinoids, microdermabrasion, minimally invasive techniques such as microneedling, fractional lasers, microneedling radiofrequency devices and invasive procedures such as acne scar surgeries and ablative lasers are used for acne scars, each with its own unique advantages and disadvantages. This study is a retrospective assessment of efficacy and safety of microneedling fractional radiofrequency in the treatment of acne scars. METHODS: Thirty one patients of skin types III-V with moderate and severe facial acne scarring received four sequential fractional radiofrequency treatments over a period of 6 months with an interval of 6 weeks between each session. Goodman & Baron's acne scar grading system was used for assessment by a side by side comparison of preoperative and post- operative photographs taken at their first visit and at the end of 3 months after the last session. RESULTS: Estimation of improvement with Goodman and Baron's Global Acne Scarring System showed that by qualitative assessment of 31 patients with grade 3 and grade 4 acne scars, 80.64% showed improvement by 2 grades and 19.35% showed improvement by 1 grade. Quantitative assessment showed that 58% of the patients had moderate, 29% had minimal, 9% had good and 3% showed very good improvement. Adverse effects were limited to transient pain, erythema, edema and hyperpigmentation. CONCLUSION: Microneedling fractional radiofrequency is efficacious for the treatment of moderate and severe acne scars.

7.
Mater Sci Eng C Mater Biol Appl ; 35: 283-90, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24411379

RESUMO

The uniformity of aminosilane layers typically used for the modification of hydroxyl bearing surfaces such as silicon dioxide is critical for a wide variety of applications, including biosensors. However, in spite of many studies that have been undertaken on surface silanization, there remains a paucity of easy-to-implement deposition methods reproducibly yielding smooth aminosilane monolayers. In this study, solution- and vapor-phase deposition methods for three aminoalkoxysilanes differing in the number of reactive groups (3-aminopropyl triethoxysilane (APTES), 3-aminopropyl methyl diethoxysilane (APMDES) and 3-aminopropyl dimethyl ethoxysilane (APDMES)) were assessed with the aim of identifying methods that yield highly uniform and reproducible silane layers that are resistant to minor procedural variations. Silane film quality was characterized based on measured thickness, hydrophilicity and surface roughness. Additionally, hydrolytic stability of the films was assessed via these thickness and contact angle values following desorption in water. We found that two simple solution-phase methods, an aqueous deposition of APTES and a toluene based deposition of APDMES, yielded high quality silane layers that exhibit comparable characteristics to those deposited via vapor-phase methods.


Assuntos
Materiais Revestidos Biocompatíveis/síntese química , Silanos/química , Dióxido de Silício/química , Água/química , Adsorção , Gases/química , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Transição de Fase , Soluções , Propriedades de Superfície
8.
Biosens Bioelectron ; 26(10): 4024-31, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-21524903

RESUMO

A photonic crystal (PhC) waveguide based optical biosensor capable of label-free and error-corrected sensing was investigated in this study. The detection principle of the biosensor involved shifts in the resonant mode wavelength of nanocavities coupled to the silicon PhC waveguide due to changes in ambient refractive index. The optical characteristics of the nanocavity structure were predicted by FDTD theoretical methods. The device was fabricated using standard nanolithography and reactive-ion-etching techniques. Experimental results showed that the structure had a refractive index sensitivity of 10(-2) RIU. The biosensing capability of the nanocavity sensor was tested by detecting human IgG molecules. The device sensitivity was found to be 2.3±0.24×10(5) nm/M with an achievable lowest detection limit of 1.5 fg for human IgG molecules. Additionally, experimental results demonstrated that the PhC devices were specific in IgG detection and provided concentration-dependent responses consistent with Langmuir behavior. The PhC devices manifest outstanding potential as microscale label-free error-correcting sensors, and may have future utility as ultrasensitive multiplex devices.


Assuntos
Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Cristalização , Desenho de Equipamento , Humanos , Imunoglobulina G/análise , Microscopia Eletrônica de Varredura , Nanoestruturas , Dispositivos Ópticos , Fenômenos Ópticos , Silício
9.
Anal Chem ; 83(10): 3750-7, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21517019

RESUMO

One of the critical steps in the development of an analytical technique is to confirm that its experimental response correlates with predictions derived from the theoretical framework on which it is based. This validates the technique quantitatively and, in the case of a biosensor, facilitates a correlation of the sensor's output signal to the concentration of the analyte being tested. Herein we report studies demonstrating that the quantitative response of arrayed imaging reflectometry (AIR), a highly sensitive label-free biosensing method, is a predictable function of the probe and analyte properties. We first incorporated a standard one-site Langmuir binding model describing probe-analyte interactions at the surface into the theoretical model for thickness-dependent reflectance in AIR. This established a hypothetical correlation between the analyte concentration and the AIR response. Spectroscopic ellipsometry, surface plasmon resonance, and AIR were then used to validate this model for two biomedically important proteins, fibroblast growth factor-2 and vascular endothelial growth factor. While our studies demonstrated that the 1:1 one-site Langmuir model accurately described the observed response of macrospot AIR arrays, either a two-site Langmuir model or a Sips isotherm better described the behavior of AIR microarrays. These studies confirmed the quantitative performance of AIR across a range of probe-analyte affinities. Furthermore, the methodology developed here can be extended to other label-free biosensing platforms, thus facilitating a more accurate and quantitative interpretation of the sensor response.


Assuntos
Anticorpos/imunologia , Técnicas Biossensoriais/métodos , Fator 2 de Crescimento de Fibroblastos/análise , Fator A de Crescimento do Endotélio Vascular/análise , Fator 2 de Crescimento de Fibroblastos/química , Fator 2 de Crescimento de Fibroblastos/imunologia , Cinética , Modelos Teóricos , Ligação Proteica , Ressonância de Plasmônio de Superfície/métodos , Fator A de Crescimento do Endotélio Vascular/química , Fator A de Crescimento do Endotélio Vascular/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA