Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clin Transl Radiat Oncol ; 46: 100742, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38440792

RESUMO

Background and purpose: MRI-guided radiotherapy (MRIgRT) offers multiple potential advantages over CT-guidance. This study examines the potential clinical benefits of MRIgRT for men with localised prostate cancer, in the setting of moderately hypofractionated radiotherapy. We evaluate two-year toxicity outcomes, early biochemical response and patient-reported outcomes (PRO), using data obtained from a multicentre international registry study, for the first group of patients with prostate cancer who underwent treatment on a 1.5 T MR-Linac. Materials and methods: Patients who were enrolled within the MOMENTUM study and received radical treatment with 60 Gy in 20 fractions were identified. PSA levels and CTCAE version 5.0 toxicity data were measured at follow-up visits. Those patients who consented to PRO data collection also completed EQ-5D-5L, EORTC QLQ-C30 and EORTC QLQ-PR25 questionnaires. Results: Between November 2018 and June 2022, 146 patients who had MRIgRT for localised prostate cancer on the 1.5 T MR-Linac were eligible for this study. Grade 2 and worse gastro-intestinal (GI) toxicity was reported in 3 % of patients at three months whilst grade 2 and worse genitourinary (GU) toxicity was 7 % at three months. There was a significant decrease in the median PSA at 12 months. The results from both the EQ-5D-5L data and EORTC global health status scale indicate a decline in the quality of life (QoL) during the first six months. The mean change in score for the EORTC scale showed a decrease of 11.4 points, which is considered clinically important. QoL improved back to baseline by 24 months. Worsening of hormonal symptoms in the first six months was reported with a return to baseline by 24 months and sexual activity in all men worsened in the first three months and returned to baseline at 12 months. Conclusion: This study establishes the feasibility of online-MRIgRT for localised prostate on a 1.5 T MR-Linac with low rates of toxicity, similar to that published in the literature. However, the clinical benefits of MRIgRT over conventional radiotherapy in the setting of moderate hypofractionation is not evident. Further research will focus on the delivery of ultrahypofractionated regimens, where the potential advantages of MRIgRT for prostate cancer may become more discernible.

2.
Int J Radiat Oncol Biol Phys ; 118(2): 378-389, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37633499

RESUMO

PURPOSE: The use of magnetic resonance imaging (MRI) in radiotherapy planning is becoming more widespread, particularly with the emergence of MRI-guided radiotherapy systems. Existing guidelines for defining the prostate bed clinical target volume (CTV) show considerable heterogeneity. This study aimed to establish baseline interobserver variability (IOV) for prostate bed CTV contouring on MRI, develop international consensus guidelines, and evaluate its effect on IOV. METHODS AND MATERIALS: Participants delineated the CTV on 3 MRI scans, obtained from the Elekta Unity MR-Linac, as per their normal practice. Radiation oncologist contours were visually examined for discrepancies, and interobserver comparisons were evaluated against simultaneous truth and performance level estimation (STAPLE) contours using overlap metrics (Dice similarity coefficient and Cohen's kappa), distance metrics (mean distance to agreement and Hausdorff distance), and volume measurements. A literature review of postradical prostatectomy local recurrence patterns was performed and presented alongside IOV results to the participants. Consensus guidelines were collectively constructed, and IOV assessment was repeated using these guidelines. RESULTS: Sixteen radiation oncologists' contours were included in the final analysis. Visual evaluation demonstrated significant differences in the superior, inferior, and anterior borders. Baseline IOV assessment indicated moderate agreement for the overlap metrics while volume and distance metrics demonstrated greater variability. Consensus for optimal prostate bed CTV boundaries was established during a virtual meeting. After guideline development, a decrease in IOV was observed. The maximum volume ratio decreased from 4.7 to 3.1 and volume coefficient of variation reduced from 40% to 34%. The mean Dice similarity coefficient rose from 0.72 to 0.75 and the mean distance to agreement decreased from 3.63 to 2.95 mm. CONCLUSIONS: Interobserver variability in prostate bed contouring exists among international genitourinary experts, although this is lower than previously reported. Consensus guidelines for MRI-based prostate bed contouring have been developed, and this has resulted in an improvement in contouring concordance. However, IOV persists and strategies such as an education program, development of a contouring atlas, and further refinement of the guidelines may lead to additional improvements.


Assuntos
Radioterapia Guiada por Imagem , Masculino , Humanos , Radioterapia Guiada por Imagem/métodos , Próstata/diagnóstico por imagem , Variações Dependentes do Observador , Planejamento da Radioterapia Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
3.
Radiother Oncol ; 180: 109457, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36608770

RESUMO

BACKGROUND AND PURPOSE: The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers' roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. MATERIALS AND METHODS: 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. RESULTS: Comparison of the radiographers' and clinicians' contours resulted in a median (range) DSC of 0.92 (0.86 - 0.99), median (range) MDA of 0.98 mm (0.2-1.7) and median (range) HD of 6.3 mm (2.5-11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians' offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88-1.0), median (range) MDA was 0.8 mm (0.04-1.18) and HD was 5.15 mm (2.09-8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians' offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. CONCLUSION: Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.


Assuntos
Neoplasias da Próstata , Radioterapia Guiada por Imagem , Masculino , Humanos , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Glândulas Seminais , Pelve , Radioterapia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-36654720

RESUMO

The implementation of MRI-guided online adaptive radiotherapy has enabled extension of therapeutic radiographers' roles to include contouring. An offline interobserver variability study compared five radiographers' and five clinicians' contours on 10 MRIs acquired on a MR-Linac from 10 patients. All contours were compared to a "gold standard" created from an average of clinicians' contours. The median (range) DSC of radiographers' and clinicians' contours compared to the "gold standard" was 0.91 (0.86-0.96), and 0.93 (0.88-0.97) respectively illustrating non-inferiority of the radiographers' contours to the clinicians. There was no significant difference in HD, MDA or volume size between the groups.

5.
Clin Transl Radiat Oncol ; 37: 25-32, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36052018

RESUMO

Background: The prostate demonstrates inter- and intra- fractional changes and thus adaptive radiotherapy would be required to ensure optimal coverage. Daily adaptive radiotherapy for MRI-guided radiotherapy can be both time and resource intensive when structure delineation is completed manually. Contours can be auto-generated on the MR-Linac via a deformable image registration (DIR) based mapping process from the reference image. This study evaluates the performance of automatically generated target structure contours against manually delineated contours by radiation oncologists for prostate radiotherapy on the Elekta Unity MR-Linac. Methods: Plans were generated from prostate contours propagated by DIR and rigid image registration (RIR) for forty fractions from ten patients. A two-dose level SIB (simultaneous integrated boost) IMRT plan is used to treat localised prostate cancer; 6000 cGy to the prostate and 4860 cGy to the seminal vesicles. The dose coverage of the PTV 6000 and PTV 4860 created from the manually drawn target structures was evaluated with each plan. If the dose objectives were met, the plan was considered successful in covering the gold standard (clinician-delineated) volume. Results: The mandatory PTV 6000 dose objective (D98% > 5580 cGy) was met in 81 % of DIR plans and 45 % of RIR plans. The SV were mapped by DIR only and for all the plans, the PTV 4860 dose objective met the optimal target (D98% > 4617 cGy). The plans created by RIR led to under-coverage of the clinician-delineated prostate, predominantly at the apex or the bladder-prostate interface. Conclusion: Plans created from DIR propagation of prostate contours outperform those created from RIR propagation. In approximately 1 in 5 DIR plans, dosimetric coverage of the gold standard PTV was not clinically acceptable. Thus, at our institution, we use a combination of DIR propagation of contours alongside manual editing of contours where deemed necessary for online treatments.

6.
Br J Radiol ; 95(1131): 20210800, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35073158

RESUMO

Advances in radiotherapy technology have increased precision of treatment delivery and in some tumour types, improved cure rates and decreased side effects. A new generation of radiotherapy machines, hybrids of an MRI scanner and a linear accelerator, has the potential to further transform the practice of radiation therapy in some cancers. Facilitating superior image quality and the ability to change the dose distribution online on a daily basis (termed "daily adaptive replanning"), MRI-guided radiotherapy machines allow for new possibilities including increasing dose, for hard to treat cancers, and more selective sparing of healthy tissues, where toxicity reduction is the key priority.These machines have already been used to treat most types of cancer, although experience is still in its infancy. This review summarises the potential and current evidence for MRI-guided radiotherapy, with a predominant focus on prostate cancer. Current advantages and disadvantages are discussed including a realistic appraisal of the likely potential to improve patient outcomes. In addition, horizon scanning for near-term possibilities for research and development will hopefully delineate the potential role for this technology over the next decade.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata/radioterapia , Radioterapia (Especialidade)/tendências , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Aceleradores de Partículas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Ann Palliat Med ; 10(5): 5969-5987, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33752437

RESUMO

There has been growing interest in oligometastatic prostate cancer (OMPC) with a mounting body of evidence to suggest that it is a distinct disease state, both biologically and prognostically, when compared to polymetastatic prostate cancer. Three subgroups have been recognised; de novo synchronous, metachronous/oligorecurrent and oligoprogressive disease. The belief that patients with OMPC can be treated more aggressively to improve survival is transforming patient care. Identifying these patients poses the first challenge, and we explore the imaging modalities currently utilised and those that are promising. For patients with de novo synchronous OMPC, both early systemic treatment in addition to androgen deprivation therapy (ADT) and radiotherapy to the prostate increase overall survival (OS), and both are increasingly being integrated into routine clinical practice. Metastasis-directed therapy (MDT) has predominantly been delivered using stereotactic body radiotherapy (SBRT) in prostate cancer and studies have shown SBRT is well-tolerated, provides excellent local control and can be used to delay ADT in the metachronous setting. We discuss the current management strategies in OMPC, review the evidence supporting the use of SBRT and outline ongoing trials.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Antagonistas de Androgênios/uso terapêutico , Humanos , Masculino , Neoplasias da Próstata/terapia
8.
Eur J Anaesthesiol ; 29(9): 438-45, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22569028

RESUMO

BACKGROUND: The immediate postoperative period is important, as the patient recovers from the acute derangements resulting from the surgical insult and anaesthesia. Incomplete or incorrect communication between the anaesthesiologist and the postanaesthesia care unit nurse during the transfer process may lead to dangerous clinical mistakes. The literature examining handovers from operating room to the postanaesthesia care unit is scarce. OBJECTIVES: The primary objective of this study was to examine the current transfer practice through observation of handovers between the anaesthesiologists and the postanaesthesia care unit staff in order to identify data omissions. The secondary objective was to learn which data items the clinicians and nurses thought were a necessary part of the transfer process and whether this information was communicated at the time of handover. DESIGN: A prospective observational study. SETTING: Academic hospital in Toronto, Canada. PARTICIPANTS AND INTERVENTIONS: After Research Ethics Board approval, a prospective observational study was conducted at a university-affiliated teaching centre. During a 2-month period, multiple observations of patient handover were performed. The data provided were marked on a checklist. At the end of the study, participating nurses and physicians were surveyed regarding the necessity of communicating different items on the checklist. RESULTS: A total of 526 transfers were observed. Of 29 data items examined, only two items (type of surgery and analgesics given) were reported in more than 90% of handovers. Only three items (difficult intubation, ST-wave changes and co-morbidities/healthy) were reported in more than 80% of cases. Many items deemed as needed to be reported by the participants in the study were not communicated. CONCLUSION: This study demonstrates that the handover process is inconsistent and in some cases information defined as important by the physicians and the nurses is not transferred. Further studies need to investigate whether a handover protocol leads to a minimisation of omissions in information transfer.


Assuntos
Anestesiologia , Comunicação , Continuidade da Assistência ao Paciente , Transferência de Pacientes , Adulto , Período de Recuperação da Anestesia , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sala de Recuperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA