Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Emerg Infect Dis ; 29(6): 1-9, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37210749

RESUMO

A carbapenem-resistant Enterobacterales outbreak at a veterinary teaching hospital in the United States increased urgency for improved communication among diagnostic laboratories, public health authorities, veterinarians, and pet owners. Kansas State University, University of Missouri, Kansas Department of Health and Environment, and Veterinary Laboratory Investigation and Response Network created a surveillance, storage, and reporting protocol for veterinary antimicrobial-resistant bacteria; determined frequency of those bacteria in companion animals during 2018-2021; and created educational flyers for veterinarians and pet owners. We recommend a One Health strategy to create efficient surveillance programs to identify and report antimicrobial-resistant bacteria and educate veterinarians and pet owners about transmission risks.


Assuntos
Anti-Infecciosos , Saúde Única , Animais , Saúde Pública , Carbapenêmicos/farmacologia , Hospitais Veterinários , Hospitais de Ensino , Bactérias , Antibacterianos/farmacologia
2.
Infect Control Hosp Epidemiol ; 43(10): 1333-1338, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34612179

RESUMO

BACKGROUND: In 2015, an international outbreak of Mycobacterium chimaera infections among patients undergoing cardiothoracic surgeries was associated with exposure to contaminated LivaNova 3T heater-cooler devices (HCDs). From June 2017 to October 2020, the Centers for Disease Control and Prevention was notified of 18 patients with M. chimaera infections who had undergone cardiothoracic surgeries at 2 hospitals in Kansas (14 patients) and California (4 patients); 17 had exposure to 3T HCDs. Whole-genome sequencing of the clinical and environmental isolates matched the global outbreak strain identified in 2015. METHODS: Investigations were conducted at each hospital to determine the cause of ongoing infections. Investigative methods included query of microbiologic records to identify additional cases, medical chart review, observations of operating room setup, HCD use and maintenance practices, and collection of HCD and environmental samples. RESULTS: Onsite observations identified deviations in the positioning and maintenance of the 3T HCDs from the US Food and Drug Administration (FDA) recommendations and the manufacturer's updated cleaning and disinfection protocols. Additionally, most 3T HCDs had not undergone the recommended vacuum and sealing upgrades by the manufacturer to decrease the dispersal of M. chimaera-containing aerosols into the operating room, despite hospital requests to the manufacturer. CONCLUSIONS: These findings highlight the need for continued awareness of the risk of M. chimaera infections associated with 3T HCDs, even if the devices are newly manufactured. Hospitals should maintain vigilance in adhering to FDA recommendations and the manufacturer's protocols and in identifying patients with potential M. chimaera infections with exposure to these devices.


Assuntos
Infecções por Mycobacterium não Tuberculosas , Infecções por Mycobacterium , Humanos , Contaminação de Equipamentos , Kansas , Quimera , Infecções por Mycobacterium/epidemiologia , Infecções por Mycobacterium/etiologia , Complexo Mycobacterium avium , Aerossóis , Infecções por Mycobacterium não Tuberculosas/epidemiologia , Infecções por Mycobacterium não Tuberculosas/etiologia , Infecções por Mycobacterium não Tuberculosas/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA