Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
ACS Catal ; 12(19): 11974-11983, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36249872

RESUMO

Spatio-temporal nonuniformities in H2 oxidation on individual Rh(h k l) domains of a polycrystalline Rh foil were studied in the 10-6 mbar pressure range by photoemission electron microscopy (PEEM), X-ray photoemission electron microscopy (XPEEM), and low-energy electron microscopy (LEEM). The latter two were used for in situ correlative microscopy to zoom in with significantly higher lateral resolution, allowing detection of an unusual island-mediated oxygen front propagation during kinetic transitions. The origin of the island-mediated front propagation was rationalized by model calculations based on a hybrid approach of microkinetic modeling and Monte Carlo simulations.

2.
Catal Letters ; 152(10): 2892-2907, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36196216

RESUMO

A surface science based approach was applied to model carbon supported Pd nanoparticle catalysts. Employing physical vapour deposition of Pd on sputtered surfaces of highly oriented pyrolytic graphite (HOPG), model catalysts were prepared that are well-suited for characterization by X-ray photoelectron spectroscopy (XPS) and scanning tunneling microscopy (STM). Analysis of the HOPG substrate before and after ion-bombardment, and of Pd/HOPG before and after annealing, revealed the number of "nominal" HOPG defects (~ 1014 cm-2) as well as the nucleation density (~ 1012 cm-2) and structural characteristics of the Pd nanoparticles (mean size/height/distribution). Two model systems were stabilized by UHV annealing to 300 °C, with mean Pd particles sizes of 4.3 and 6.8 nm and size/height aspect ratio up to ~ 10. A UHV-compatible flow microreactor and gas chromatography were used to determine the catalytic performance of Pd/HOPG in ethylene (C2H4) hydrogenation up to 150 °C under atmospheric pressure, yielding temperature-dependent conversion values, turnover frequencies (TOFs) and activation energies. The performance of Pd nanocatalysts is compared to that of polycrystalline Pd foil and contrasted to Pt/HOPG and Pt foil, pointing to a beneficial effect of the metal/carbon phase boundary, reflected by up to 10 kJ mol-1 lower activation energies for supported nanoparticles.

3.
J Mech Behav Biomed Mater ; 125: 104815, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34678618

RESUMO

Bone is a biological tissue with unique mechanical properties, owing to a complex hierarchical structure ranging from the nanoscale up to the macroscale. To better understand bone mechanics, investigation of mechanical properties of all structural elements at every hierarchical level and how they interact is necessary. Testing of bone structures at the lower microscale, e.g. bone lamellae, has been least performed and remains a challenge. Focused ion beam (FIB) milling is an attractive technique for machining microscopic samples from bone material and performing mechanical testing at the microscale using atomic force microscopy (AFM) and nanoindentation setups. So far, reported studies at this length scale have been performed on bone samples of animal origin, mostly in a dehydrated state, except for one study. Here we present an AFM-based microbeam bending method for performing bending measurements in both dehydrated and rehydrated conditions at the microscale. Single lamella bone microbeams of four human donors, aged 65-94 yrs, were machined via FIB and tested both in air and fully submerged in Hank's Balanced Salt Solution (HBSS) to investigate the effect of (de)hydration and to a certain extent, of age, on bone mechanics. Bending moduli were found to reduce up to 5 times after 2 h of rehydration and no trend of change in bending moduli with respect to age could be observed. Mechanical behavior changed from almost purely elastic to viscoelastic upon rehydration and a trend of lower dissipated energy in samples from older donors could be observed in the rehydrated state. These results confirm directly the importance of water for the mechanical properties of bone tissue at the microscale. Moreover, the trend of lowered capability of energy dissipation in older donors may contribute to a decrease of fracture toughness and thus an increase in bone fragility with age.


Assuntos
Osso e Ossos , Fêmur , Idoso , Osso Cortical , Humanos
5.
Materials (Basel) ; 14(5)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803401

RESUMO

Energy-loss magnetic chiral dichroism (EMCD) is a versatile method for measuring magnetism down to the atomic scale in transmission electron microscopy (TEM). As the magnetic signal is encoded in the phase of the electron wave, any process distorting this characteristic phase is detrimental for EMCD. For example, elastic scattering gives rise to a complex thickness dependence of the signal. Since the details of elastic scattering depend on the electron's energy, EMCD strongly depends on the acceleration voltage. Here, we quantitatively investigate this dependence in detail, using a combination of theory, numerical simulations, and experimental data. Our formulas enable scientists to optimize the acceleration voltage when performing EMCD experiments.

6.
ACS Catal ; 11(8): 4920-4928, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33898080

RESUMO

Compound materials, such as transition-metal (TM) carbides, are anticipated to be effective electrocatalysts for the carbon dioxide reduction reaction (CO2RR) to useful chemicals. This expectation is nurtured by density functional theory (DFT) predictions of a break of key adsorption energy scaling relations that limit CO2RR at parent TMs. Here, we evaluate these prospects for hexagonal Mo2C in aqueous electrolytes in a multimethod experiment and theory approach. We find that surface oxide formation completely suppresses the CO2 activation. The oxides are stable down to potentials as low as -1.9 V versus the standard hydrogen electrode, and solely the hydrogen evolution reaction (HER) is found to be active. This generally points to the absolute imperative of recognizing the true interface establishing under operando conditions in computational screening of catalyst materials. When protected from ambient air and used in nonaqueous electrolyte, Mo2C indeed shows CO2RR activity.

7.
Nat Commun ; 11(1): 4801, 2020 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-32968079

RESUMO

Exsolution of metal nanoparticles from perovskite-type oxides is a very promising approach to obtain catalysts with superior properties. One particularly interesting property of exsolution catalysts is the possibility of electrochemical switching between different activity states. In this work, synchrotron-based in-situ X-ray diffraction experiments on electrochemically polarized La0.6Sr0.4FeO3-δ thin film electrodes are performed, in order to simultaneously obtain insights into the phase composition and the catalytic activity of the electrode surface. This shows that reversible electrochemical switching between a high and low activity state is accompanied by a phase change of exsolved particles between metallic α--Fe and Fe-oxides. Reintegration of iron into the perovskite lattice is thus not required for obtaining a switchable catalyst, making this process especially interesting for intermediate temperature applications. These measurements also reveal how metallic particles on La0.6Sr0.4FeO3-δ electrodes affect the H2 oxidation and H2O splitting mechanism and why the particle size plays a minor role.

8.
J Mech Behav Biomed Mater ; 106: 103741, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32250952

RESUMO

Continuing technological advancement of mechanical characterization at the microscale has enabled the isolation of micron-sized specimens and their direct mechanical characterization. Such techniques, initially developed for engineering materials and MEMS, can also be applied on hard biological materials. Bone is a material with a complex hierarchical structure ranging from the macro- all the way down to the nanoscale. To fully understand bone tissue mechanics, knowledge of the mechanics of all structural elements i.e. at every length scale is necessary. Particularly, the mechanical properties of microstructural elements, such as bone lamellae are still largely unknown. In the last decade, testing protocols have been devised to close this gap including bending and compression of micrometer-sized bone specimens. However, the precision and accuracy of results obtained have not been discussed. In this study, we aim to do exactly this: we validate microbeam bending by testing silicon microbeams with known mechanical constants, and evaluate the precision and sources of errors in both microbeam bending and micropillar compression by means of finite element (FE) modeling. Bending of Si-microbeams reproduced the expected value for the bending modulus within 17% accuracy, although the effect of geometrical uncertainties was estimated to result in relative errors of up to 50%. The deformation of constraining bulk material had a smaller influence, with relative errors of 11%, for microbeam bending and 25% for micropillar compression. For the latter this error could be sufficiently eliminated by the Sneddon correction. The tapering of micropillars had a negligible effect on overall apparent stiffness, but induced inhomogeneous stress state within micropillars may lead to superposed structural deformation mechanisms and be responsible for failure patterns observed in past studies.


Assuntos
Osso e Ossos , Fenômenos Biomecânicos , Análise de Elementos Finitos , Pressão , Estresse Mecânico
9.
ACS Nano ; 13(7): 8047-8054, 2019 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-31282653

RESUMO

Highly oriented Ge0.81Sn0.19 nanowires have been synthesized by a low-temperature chemical vapor deposition growth technique. The nanostructures form by a self-seeded vapor-liquid-solid mechanism. In this process, liquid metallic Sn seeds enable the anisotropic crystal growth and act as a sole source of Sn for the formation of the metastable Ge1-xSnx semiconductor material. The strain relaxation for a lattice mismatch of ε = 2.94% between the Ge (111) substrate and the constant Ge0.81Sn0.19 composition of nanowires is confined to a transition zone of <100 nm. In contrast, Ge1-xSnx structures with diameters in the micrometer range show a 5-fold longer compositional gradient very similar to epitaxial thin-film growth. Effects of the Sn growth promoters' dimensions on the morphological and compositional evolution of Ge1-xSnx are described. The temperature- and laser power-dependent photoluminescence analyses verify the formation of a direct band gap material with emission in the mid-infrared region and values expected for unstrained Ge0.81Sn0.19 (e.g., band gap of 0.3 eV at room temperature). These materials  hold promise in applications such as thermal imaging and photodetection as well as building blocks for group IV-based mid- to near-IR photonics.

10.
J Mech Behav Biomed Mater ; 52: 51-62, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25842157

RESUMO

We here report an improved experimental technique for the determination of Young׳s modulus and uniaxial strength of extracellular bone matrix at the single micrometer scale, giving direct access to the (homogeneous) deformation (or strain) states of the tested samples and to the corresponding mechanically recoverable energy, called potential or elastic energy. Therefore, a new protocol for Focused Ion Beam milling of prismatic non-tapered micropillars, and attaching them to a rigid substrate, was developed. Uniaxial strength turns out as at least twice that measured macroscopically, and respective ultimate stresses are preceded by hardening elastoplastic states, already at very low load levels. The unloading portion of quasi-static load-displacement curves revealed Young׳s modulus of 29GPa in bovine extracellular bone matrix. This value is impressively confirmed by the corresponding prediction of a multiscale mechanics model for bone, which has been comprehensively validated at various other observation scales, across tissues from the entire vertebrate animal kingdom.


Assuntos
Força Compressiva , Módulo de Elasticidade , Matriz Extracelular/metabolismo , Fêmur/citologia , Teste de Materiais/instrumentação , Animais , Fenômenos Biomecânicos , Bovinos , Estresse Mecânico
11.
Nanotechnology ; 25(30): 305302, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25008053

RESUMO

In this paper, we report on the surface evolution of focused ion beam treated single crystalline Bi(001) with respect to different beam incidence angles and channeling effects. 'Erosive' sputtering appears to be the dominant mechanism at room temperature (RT) and diffusion processes during sputtering seem to play only a minor role for the surface evolution of Bi. The sputtering yield of Bi(001) shows anomalous behavior when increasing the beam incidence angle along particular azimuthal angles of the specimen. The behavior of the sputtering yield could be related to channeling effects and the relevant channeling directions are identified. Dynamic annealing processes during ion irradiation retain the crystalline quality of the Bi specimen allowing ion channeling at RT. Lowering the specimen temperature to T = -188 °C reduces dynamic annealing processes and thereby disables channeling effects. Furthermore unexpected features are observed at normal beam incidence angle. Spike-like features appear during the ion beam induced erosion, whose growth directions are not determined by the ion beam but by the channeling directions of the Bi specimen.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA