RESUMO
This study reports the development of a novel amphiphobic coating. The coating is a bilayer arrangement, where carbon nanotubes (CNTs) form the underlayer and fluorinated alkyl-silane (FAS) forms the overlayer, resulting in the development of highly amphiphobic coatings suitable for a wide range of substrates. The effectiveness of these coatings is demonstrated through enhanced contact angles for water and artificial blood plasma fluid on glass, stainless steel, and porous PTFE. The coatings were characterized using Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), atomic force microscopy (AFM), and contact angle (CA) measurements. The water contact angles achieved with the bilayer coating were 106 ± 2°, 116 ± 2°, and 141 ± 2° for glass, stainless steel, and PTFE, respectively, confirming the hydrophobic nature of the coating. Additionally, the coating displayed high repellency for blood plasma, exhibiting contact angles of 102 ± 2°, 112 ± 2°, and 134 ± 2° on coated glass, stainless steel, and PTFE surfaces, respectively. The presence of the CNT underlayer improved plasma contact angles by 29%, 21.7%, and 16.5% for the respective surfaces. The presence of the CNT layer improved surface roughness significantly, and the average roughness of the bilayer coating on glass, stainless steel, and PTFE was measured to be 488 nm, 301 nm, and 274 nm, respectively. Mechanistically, the CNT underlayer contributed to the surface roughness, while the FAS layer provided high amphiphobicity. The maximum effect was observed on modified glass, followed by stainless steel and PTFE surfaces. These findings highlight the promising potential of this coating method across diverse applications, particularly in the biomedical industry, where it can help mitigate complications associated with device-fluid interactions.
RESUMO
OBJECTIVE: Preoperative left ventricular ejection fraction (LVEF) is one of the main predictors of outcomes in cardiac surgery. We present current era outcomes and associated direct cost in nonemergent isolated coronary artery bypass surgery (CABG) patients with LVEF <20% over the past 6 years and compare it with higher EF subgroups. METHODS: Six-year data from 2016 to 2022 at hospitals sharing Society of Thoracic Surgeons and financial data with Biome Analytics were analyzed based on 3 EF subgroups (EF ≤20%, EF 21% to 35%, and EF >35%). Outcomes and costs were assessed. RESULTS: Overall 30-day mortality of 12,649 patients was 1.9%. The EF ≤20% (n = 248), EF 21% to 35% (n = 1,408), and EF >35 (n = 10,993) cohorts had mortality of 6.9%, 3.7%, and 1.6%, respectively. The EF ≤20% subgroup had higher use of cardiopulmonary bypass, blood products, and mechanical support. In addition, the EF ≤20% subgroup had higher complication rates in almost all measured categories. Also, the EF ≤20% cohort had significantly higher length of stay, intensive care unit (ICU) hours, ICU and hospital readmissions, and lowest discharge to home rate. The strongest factors associated with mortality were postoperative cardiac arrest, renal failure requiring dialysis, extracorporeal membrane oxygenation, sepsis, prolonged ventilation, and gastrointestinal event. The overall median direct cost of care was $37,387.79 ($27,605.18, $51,720.96), with a median direct cost of care in the EF ≤20%, EF 21% to 35%, and EF >35% subgroups of $52,500.17 ($34,103.52, $80,806.79), $44,108.32 ($31,597.58, $63,788.03), and $36,521.80 ($27,168.91, $50,019.31), respectively. CONCLUSIONS: In nonemergent isolated CABG surgery, low EF continues to have higher surgical risks and higher direct cost of care despite advances in cardiovascular care.
Assuntos
Ponte de Artéria Coronária , Função Ventricular Esquerda , Humanos , Volume Sistólico , Ponte de Artéria Coronária/efeitos adversos , Estudos RetrospectivosRESUMO
Transcatheter pacing systems are self-contained, leadless, devices that offer the potential benefits of avoiding complications related to pectoral pocket and upper extremity vascular access. These systems in preapproval trials demonstrated excellent safety profile with the incidence of device-related cardiac perforation as low as 1.6% with Micra™ (Medtronic) and 1.3% in Nanostim (Abbott). In post-approval registry of Micra™ TPS, the rate of major complications was even lower than in the investigational study ranging from 0.63% to 0.77%. Recently, published report found much higher rates of need for rescue surgery, shock, tamponade, and death among patients implanted with the Micra™ device when compared with transvenous devices. This case report describes two cases of major right ventricular perforation requiring surgical intervention.
RESUMO
Anticoagulation during extracorporeal membrane oxygenation (ECMO) for Coronovirus Disease 2019 (COVID-19) can be performed by direct or indirect thrombin inhibitors but differences in outcomes with these agents are uncertain. A retrospective, multicenter study was conducted. All consecutive adult patients with COVID-19 placed on ECMO between March 1, 2020 and April 30, 2021 in participating centers, were included. Patients were divided in groups receiving either a direct thrombin inhibitor (DTI) or an indirect thrombin inhibitor such as unfractionated heparin (UFH). Overall, 455 patients with COVID-19 from 17 centers were placed on ECMO during the study period. Forty-four patients did not receive anticoagulation. Of the remaining 411 patients, DTI was used in 160 (39%) whereas 251 (61%) received UFH. At 90-days, in-hospital mortality was 50% (DTI) and 61% (UFH), adjusted hazard ratio: 0.81, 95% confidence interval (CI): 0.49-1.32. Deep vein thrombosis [adjusted odds ratio (aOR): 2.60, 95% CI: 0.90-6.65], ischemic (aOR: 1.58, 95% CI: 0.18-14.0), and hemorrhagic (aOR:1.22, 95% CI: 0.39-3.87) stroke were similar with DTI in comparison to UFH. Bleeding requiring transfusion was lower in patients receiving DTI (aOR: 0.40, 95% CI: 0.18-0.87). Anticoagulants that directly inhibit thrombin are associated with similar in-hospital mortality, stroke, and venous thrombosis and do not confer a higher risk of clinical bleeding in comparison to conventional heparin during ECMO for COVID-19.
Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Acidente Vascular Cerebral , Adulto , Humanos , Heparina/uso terapêutico , Oxigenação por Membrana Extracorpórea/efeitos adversos , Trombina , Estudos Retrospectivos , COVID-19/terapia , Anticoagulantes/uso terapêutico , Hemorragia/etiologiaRESUMO
Superhydrophobic surfaces, as indicated in the name, are highly hydrophobic and readily repel water. With contact angles greater than 150° and sliding angles less than 10°, water droplets flow easily and hardly wet these surfaces. Superhydrophobic materials and coatings have been drawing increasing attention in medical fields, especially on account of their promising applications in blood-contacting devices. Superhydrophobicity controls the interactions of cells with the surfaces and facilitates the flowing of blood or plasma without damaging blood cells. The antibiofouling effect of superhydrophobic surfaces resists adhesion of organic substances, including blood components and microorganisms. These attributes are critical to medical applications such as filter membranes, prosthetic heart valves, extracorporeal circuit tubing, and indwelling catheters. Researchers have developed various methods to fabricate blood-compatible or biocompatible superhydrophobic surfaces using different materials. In addition to being hydrophobic, these surfaces can also be antihemolytic, antithrombotic, antibacterial, and antibiofouling, making them ideal for clinical applications. In this review, the authors summarize recent developments of blood-compatible superhydrophobic surfaces, with a focus on methods and materials. The expectation of this review is that it will support the biomedical research field by providing current trends as well as future directions.
RESUMO
In a multicenter, retrospective analysis of 435 patients with refractory COVID-19 placed on V-V ECMO, cannulation by a single, dual-lumen catheter with directed outflow to the pulmonary artery was associated with lower inpatient mortality.
Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , COVID-19/terapia , Cateterismo/métodos , Catéteres , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Estudos RetrospectivosAssuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Humanos , Resultado do TratamentoRESUMO
PURPOSE: Driveline exit site (DLES) management following left ventricular assist device implantation is important for preventing driveline infection (DLI). While chlorhexidine gluconate (CHG) is generally recommended for DLES antisepsis, CHG intolerance can develop, resulting in a need for alternative antiseptics. We reviewed our institutional experience with DLES antisepsis methods in HeartMate II patients, comparing outcomes of patients with and without CHG intolerance. METHODS: Between October 2011 and March 2016, 44 patients underwent primary HeartMate II implantation. CHG was used for DLES antisepsis and povidone-iodine (PVP-I) was used in patients with CHG intolerance. DLI was defined by Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) criteria. RESULTS: Of 44 patients, 37 (84%) received CHG and 7 (16%) received PVP-I antisepsis due to CHG intolerance. Five patients (11.4%) developed a DLI, with an event per patient-year rate of 0.07. Median length of support was 521 days (interquartile range 202-881 days). Characteristics were similar between patients with and without DLI. However, a larger proportion of patients with DLI had CHG intolerance compared to patients without DLI (60.0% vs. 10.3%, p:0.05). Causative organisms were Staphylococcus aureus in CHG-intolerant patients and Stenotrophomonas and Acinetobacter in CHG-tolerant patients. Kaplan-Meier method and log-rank test demonstrated decreased infection-free days in patients using PVP-I rather than CHG (p:0.01). CONCLUSIONS: While the etiology of DLI is multifactorial, CHG intolerance appears to be a risk factor. Our findings highlight the need for larger studies comparing the efficacy of antiseptics for DLES care, particularly for patients with CHG contraindications.