Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMJ Case Rep ; 16(11)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940197

RESUMO

An internal hernia through the foramen of Winslow represents a rare surgical pathology. This report describes a case with incipient caecal ischaemia and discusses current diagnostic and therapeutic approaches. A patient in his early 60s presented at the emergency department with abdominal pain and last bowel movement three days prior. A CT scan of the abdomen suggested an internal hernia into the lesser sac. Intraoperatively, the suspected diagnosis could be confirmed laparoscopically with a twisted mobile caecum herniating through the foramen of Winslow. Due to a suspected ischaemia and laparoscopic frustrated reduction, a right open hemicolectomy was performed. The hernia gap was closed. The postoperative course was uneventful. Despite the rarity of internal hernias in patients without prior abdominal surgery, surgeons should be aware of this entity. The diagnosis can be difficult and sometimes only established intraoperatively. Open surgery is usually required. If the gap is clearly identified, the recommendations tend towards its closure.


Assuntos
Doenças do Ceco , Hérnia Abdominal , Obstrução Intestinal , Humanos , Hérnia Abdominal/complicações , Hérnia Abdominal/diagnóstico por imagem , Hérnia Abdominal/cirurgia , Hérnia/complicações , Hérnia/diagnóstico por imagem , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Ceco/diagnóstico por imagem , Ceco/cirurgia , Doenças do Ceco/complicações , Doenças do Ceco/diagnóstico por imagem , Doenças do Ceco/cirurgia , Hérnia Interna
2.
Minerva Anestesiol ; 88(3): 121-128, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34527406

RESUMO

BACKGROUND: Double-lumen endobronchial tubes (DLT) continue to be the most widely used method for obtaining lung isolation during anesthesia. We compared recommendations for DLT size selection with radiologically assessed lower airway dimensions gathered from a large patient population. METHODS: For this retrospective comparative study, we assessed computed tomography (CT) scans of 150 adults with no known airway pathologies. Using these scans, we measured the diameter and length of the trachea and the diameter of the mainstem bronchi. These airway dimensions were then compared to the dimensions of left-sided DLTs of three different manufacturers. Size selection was based on one standard textbook's recommendations. RESULTS: We found the recommended DLT sizes were occasionally too small but more often too large, particularly in the endobronchial airway. With the DLT Vivasight-DL®, mismatching occurred in 28.7% (43/150) of the patients at the distal mainstem bronchus and 8% (12/150) at the tracheal level. This mismatching happened most often in females (left distal mainstem bronchus 34/68, 50%; trachea 9/68, 13.2%). Conversely, the DLT was more often too small for male patients in both the left main bronchus (SHER-I-BRONCH®: 8/82, 9.8%) and the trachea (SHER-I-BRONCH®: 2/82, 2.4%). The endobronchial tube portion was more often too long in females (Vivasight® DLT: 11/68, 16%) than males (9/82, 11%). CONCLUSIONS: A considerable proportion of the recommended DLT sizes from all three manufacturers was incompatible with individual patient's lower airway dimensions.


Assuntos
Intubação Intratraqueal , Traqueia , Adulto , Brônquios/diagnóstico por imagem , Feminino , Humanos , Intubação Intratraqueal/métodos , Pulmão , Masculino , Estudos Retrospectivos , Traqueia/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA