Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 101(6): 1098-1107, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37002948

RESUMO

BACKGROUND: The superior sinus venosus atrial septal defect is a congenital communication between the left and right atria. Open surgical approach by patch closure has historically been the only treatment option. Recently, a transcatheter approach has been developed. This study aims to compare the efficacy and safety of surgical and transcatheter approach in treatment of sinus venosus atrial septal defect. METHODS: Between March 2010 and December 2020, 58 patients (median age: 45.4, range 14.8-73.8) underwent either surgical or transcatheter correction of superior sinus venosus atrial septal defect with partial anomalous pulmonary venous drainage. RESULTS: Twenty-four patients (median age: 35.4, range 14.8-66.8) underwent surgery while 34 patients (median age: 46.8, range 15.5-73.8) had a transcatheter treatment. During the catheterization era, 41 patients was considered suitable for a transcatheter closure. In 5 patients, surgery was the patient's or referring physician's choice. In 2 cases, the procedure was unsuccessful; the remaining 34 were successfully closed (94.4% of cases). Intensive care unit stay (median of 1 day, range 0.5-4, vs. 0, range 0-2, p < 0.0001) and hospital stay (median 7 days, range 2-15 vs. 2 days, range 1-12, p < 0.0001), were significantly longer in the surgery group. Total early complication rate, consisted on procedural and in-hospital complication, were higher in the surgical group (62.5% vs. 23.5%; p = 0.005). However, complications in both groups were clinically mild. At follow-up, a small residual shunt was present in 6 patients (surgery group: 2 pts; catheterization group: 4 pts; p: NS). Imaging studies showed significant improvement of right ventricular size and unobstructed pulmonary venous return in all patients. No late complications occurred at follow-up. CONCLUSIONS: Transcatheter correction of sinus venosus atrial septal defect is effective and safe in selected patients and may be considered as a valid alternative to surgery.


Assuntos
Apêndice Atrial , Comunicação Interatrial , Humanos , Pessoa de Meia-Idade , Adulto , Resultado do Tratamento , Átrios do Coração , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia
2.
Int J Cardiovasc Imaging ; 39(7): 1405-1419, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37103667

RESUMO

Extended reality (XR), which encompasses virtual, augmented and mixed reality, is an emerging medical imaging display platform which enables intuitive and immersive interaction in a three-dimensional space. This technology holds the potential to enhance understanding of complex spatial relationships when planning and guiding cardiac procedures in congenital and structural heart disease moving beyond conventional 2D and 3D image displays. A systematic review of the literature demonstrates a rapid increase in publications describing adoption of this technology. At least 33 XR systems have been described, with many demonstrating proof of concept, but with no specific mention of regulatory approval including some prospective studies. Validation remains limited, and true clinical benefit difficult to measure. This review describes and critically appraises the range of XR technologies and its applications for procedural planning and guidance in structural heart disease while discussing the challenges that need to be overcome in future studies to achieve safe and effective clinical adoption.


Assuntos
Realidade Aumentada , Cardiopatias , Humanos , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Imageamento Tridimensional/métodos , Valor Preditivo dos Testes , Estudos Prospectivos
3.
J Imaging ; 8(11)2022 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-36354877

RESUMO

This study aimed to evaluate the accuracy and reliability of a virtual reality (VR) system line measurement tool using phantom data across three cardiac imaging modalities: three-dimensional echocardiography (3DE), computed tomography (CT) and magnetic resonance imaging (MRI). The same phantoms were also measured using industry-standard image visualisation software packages. Two participants performed blinded measurements on volume-rendered images of standard phantoms both in VR and on an industry-standard image visualisation platform. The intra- and interrater reliability of the VR measurement method was evaluated by intraclass correlation coefficient (ICC) and coefficient of variance (CV). Measurement accuracy was analysed using Bland−Altman and mean absolute percentage error (MAPE). VR measurements showed good intra- and interobserver reliability (ICC ≥ 0.99, p < 0.05; CV < 10%) across all imaging modalities. MAPE for VR measurements compared to ground truth were 1.6%, 1.6% and 7.7% in MRI, CT and 3DE datasets, respectively. Bland−Altman analysis demonstrated no systematic measurement bias in CT or MRI data in VR compared to ground truth. A small bias toward smaller measurements in 3DE data was seen in both VR (mean −0.52 mm [−0.16 to −0.88]) and the standard platform (mean −0.22 mm [−0.03 to −0.40]) when compared to ground truth. Limits of agreement for measurements across all modalities were similar in VR and standard software. This study has shown good measurement accuracy and reliability of VR in CT and MRI data with a higher MAPE for 3DE data. This may relate to the overall smaller measurement dimensions within the 3DE phantom. Further evaluation is required of all modalities for assessment of measurements <10 mm.

4.
J Cardiovasc Dev Dis ; 9(8)2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-36005432

RESUMO

Echocardiography, CT and MRI have a crucial role in the management of congenital heart disease (CHD) patients. All of these modalities can be presented in a 2D or a 3D rendered format. The aim of this paper is to review the key advantages and potential limitations, as well as the future challenges of a 3D approach in each imaging modality. The focus of this review is on anatomic rather than functional assessment. Conventional 2D echocardiography presents limitations when imaging complex lesions, whereas 3D imaging depicts the anatomy in all dimensions. CT and MRI can visualise extracardiac vasculature and guide complex biventricular repair. Three-dimensional printed models can be used in depicting complex intracardiac relationships and defining the surgical strategy in specific lesions. Extended reality imaging retained dynamic cardiac motion holds great potential for planning surgical and catheter procedures. Overall, the use of 3D imaging has resulted in a better understanding of anatomy, with a direct impact on the surgical and catheter approach, particularly in more complex cases.

5.
Pediatr Cardiol ; 43(8): 1728-1736, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35486129

RESUMO

Multi-system inflammatory syndrome in children (MIS-C) causes widespread inflammation including a pancarditis in the weeks following a COVID infection. As we prepare for further coronavirus surges, understanding the medium-term cardiac impacts of this condition is important for allocating healthcare resources. A retrospective single-center study of 67 consecutive patients with MIS-C was performed evaluating echocardiographic and electrocardiographic (ECG) findings to determine the point of worst cardiac dysfunction during the admission, then at intervals of 6-8 weeks and 6-8 months. Worst cardiac function occurred 6.8 ± 2.4 days after the onset of fever with mean 3D left ventricle (LV) ejection fraction (EF) 50.5 ± 9.8%. A pancarditis was typically present: 46.3% had cardiac impairment; 31.3% had pericardial effusion; 26.8% demonstrated moderate (or worse) valvar regurgitation; and 26.8% had coronary dilatation. Cardiac function normalized in all patients by 6-8 weeks (mean 3D LV EF 61.3 ± 4.4%, p < 0.001 compared to presentation). Coronary dilatation resolved in all but one patient who initially developed large aneurysms at presentation, which persisted 6 months later. ECG changes predominantly featured T-wave changes resolving at follow-up. Adverse events included need for ECMO (n = 2), death as an ECMO-related complication (n = 1), LV thrombus formation (n = 1), and subendocardial infarction (n = 1). MIS-C causes a pancarditis. In the majority, discharge from long-term follow-up can be considered as full cardiac recovery is expected by 8 weeks. The exception includes patients with medium sized aneurysms or greater as these may persist and require on-going surveillance.


Assuntos
COVID-19 , Aneurisma Coronário , Infecções por Coronavirus , Derrame Pericárdico , Criança , Humanos , Adolescente , Estudos Retrospectivos , Infecções por Coronavirus/complicações , Aneurisma Coronário/etiologia , Síndrome de Resposta Inflamatória Sistêmica/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA