Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
2.
Bone Joint J ; 100-B(6): 749-754, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29855250

RESUMO

Aims: The aim of this study was to establish the diagnostic accuracy of culture of joint aspirate with and without saline injection-reaspiration. Patients and Methods: This is a retrospective analysis of 580 hip and knee aspirations in patients who were deemed to have a moderate to high risk of infection, and who subsequently proceeded to revision arthroplasty over a period of 12 years. It was carried out at a large quaternary referral centre where preoperative aspiration is routine. Results: Fluid was aspirated primarily in 313 (54%) cases and after saline injection-reaspiration of a 'dry tap' in 267 (46%) cases. Overall sensitivity and specificity of the diagnostic aspirate were 84% (78% to 89%) and 85% (81% to 88%), respectively. Sensitivity and specificity of saline injection-reaspiration after 'dry tap' were 87% (79% to 92%) and 79% (72% to 84%) compared with 81% (71% to 88%) and 90% (85% to 93%) for direct aspiration. Conclusion: Preoperative joint aspiration and culture is a sensitive and specific test for the confirmation of diagnosis in patients at a moderate to high risk of prosthetic joint infection. Culture of saline injection-reaspiration also provides accurate diagnostic information in the event of a 'dry tap'. Both methods allow susceptibility testing of relevant organisms and are therefore able to guide perioperative antibiotic therapy. Cite this article: Bone Joint J 2018;100-B:749-54.


Assuntos
Artrocentese/métodos , Técnicas Microbiológicas/métodos , Infecções Relacionadas à Prótese/diagnóstico , Líquido Sinovial/microbiologia , Artroplastia/efeitos adversos , Articulação do Quadril/microbiologia , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Prótese de Quadril/microbiologia , Humanos , Articulação do Joelho/microbiologia , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Prótese do Joelho/microbiologia , Valor Preditivo dos Testes , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Cloreto de Sódio/administração & dosagem
3.
Bone Joint J ; 99-B(9): 1153-1156, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28860394

RESUMO

AIMS: Tantalum (Ta) trabecular metal components are increasingly used to reconstruct major bone defects in revision arthroplasty surgery. It is known that some metals such as silver have antibacterial properties. Recent reports have raised the question regarding whether Ta components are protective against infection in revision surgery. This laboratory study aimed to establish whether Ta has intrinsic antibacterial properties against planktonic bacteria, or the ability to inhibit biofilm formation. MATERIALS AND METHODS: Equal-sized pieces of Ta and titanium (Ti) acetabular components were sterilised and incubated with a low dose inoculum of either Staphylococcus (S.) aureus or S. epidermidis for 24 hours. After serial dilution, colony forming units (cfu) were quantified on Mueller-Hinton agar plates. In order to establish whether biofilms formed to a greater extent on one material than the other, these Ta and Ti pieces were then washed twice, sonicated and washed again to remove loosely adhered planktonic bacteria. They were then re-incubated for 24 hours prior to quantifying the number of cfu. All experiments were performed in triplicate. RESULTS: More than 1x108 cfu/ml were observed in both the Ta and Ti experiments. After washing and sonication, more than 2x107 cfu/ml were observed for both Ta and Ti groups. The results were the same for both S. aureus and S. epidermidis. CONCLUSION: Compared with Ti controls, Ta did not demonstrate any intrinsic antibacterial activity or ability to inhibit biofilm formation. Hence, intrinsic antimicrobial properties of Ta do not account for the previously observed reduction in the frequency of subsequent infections when Ta was used in revision procedures. Cite this article: Bone Joint J 2017;99-B:1153-6.


Assuntos
Artroplastia de Quadril , Biofilmes/efeitos dos fármacos , Prótese de Quadril/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/prevenção & controle , Tantálio/farmacologia , Titânio/farmacologia , Aderência Bacteriana , Reoperação , Sonicação , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus epidermidis/efeitos dos fármacos , Células-Tronco , Esterilização , Propriedades de Superfície
4.
Bone Joint J ; 99-B(1): 73-77, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28053260

RESUMO

AIMS: Vancomycin is commonly added to acrylic bone cement during revision arthroplasty surgery. Proprietary cement preparations containing vancomycin are available, but are significantly more expensive. We investigated whether the elution of antibiotic from 'home-made' cement containing vancomycin was comparable with more expensive commercially available vancomycin impregnated cement. MATERIALS AND METHODS: A total of 18 cement discs containing either proprietary CopalG+V; or 'home-made' CopalR+G with vancomycin added by hand, were made. Each disc contained the same amount of antibiotic (0.5 g gentamycin, 2 g vancomycin) and was immersed in ammonium acetate buffer in a sealed container. Fluid from each container was sampled at eight time points over a two-week period. The concentrations of gentamicin and vancomycin in the fluid were analysed using high performance liquid chromatography mass spectrometry. RESULTS: The highest peak concentrations of antibiotic were observed from the 'home-made' cements containing vancomycin, added as in the operating theatre. The overall elution of antibiotic was, fivefold (vancomycin) and twofold (gentamicin) greater from the 'home-made' mix compared with the commercially mixed cement. The use of a vacuum during mixing had no significant effect on antibiotic elution in any of the samples. CONCLUSION: These findings suggest that the addition of 2 g vancomycin powder to gentamicin-impregnated bone cement by hand significantly increases the elution of both antibiotics compared with commercially prepared cements containing vancomycin. We found no significant advantages of using expensive commercially produced vancomycin-impregnated cement and recommend the addition of vancomycin powder by hand in the operating theatre. Cite this article: Bone Joint J 2017;99-B:73-7.


Assuntos
Antibacterianos/química , Cimentos Ósseos/química , Gentamicinas/química , Polimetil Metacrilato/química , Vancomicina/química , Artroplastia de Substituição/métodos , Cromatografia Líquida de Alta Pressão , Combinação de Medicamentos , Espectrometria de Massas , Vácuo
5.
J Antimicrob Chemother ; 72(2): 410-416, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27798203

RESUMO

OBJECTIVES: To assess the Gram-positive-specific antibiotic linezolid and the broad-spectrum antibiotic tigecycline for use in local antibiotic delivery via antibiotic-loaded bone cement. METHODS: Linezolid and tigecycline were added to Biomet bone cement at varying concentrations. Antibiotic elution over 1 week was quantified by HPLC-MS. The effect of wear on elution over 51 h was determined using a modified TE-66 wear tester. Eluted antibiotics were used to determine the MICs for a panel of clinically relevant bacteria. The impact strength of antibiotic-loaded samples was determined using a Charpy-type impact testing apparatus. Cytotoxicity of eluted antibiotics against MG-63 cells was evaluated using an MTT assay. RESULTS: Linezolid and tigecycline eluted from bone cement to clinically relevant levels within 1 h and retained activity over 1 week. Mechanical wear significantly reduced elution of tigecycline, but had little effect on elution of linezolid. Linezolid showed low cytotoxicity towards MG-63 cells with ≤300 mg/mL resulting in >50% cell activity. Cytotoxicity of tigecycline was higher, with an IC50 of 5-10 mg/L. CONCLUSIONS: Linezolid and tigecycline retain activity after elution from bone cement. The concentration of tigecycline may need to be carefully controlled due to cytotoxicity. The effect of wear on bone cement may need to be considered if tigecycline is to be used for local delivery. Up to 10% linezolid can be added without affecting the impact strength of the bone cement. These results are promising indications for future investigation of these antibiotics for use in local antibiotic delivery strategies.


Assuntos
Antibacterianos/farmacocinética , Cimetidina/química , Linezolida/farmacocinética , Minociclina/análogos & derivados , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão , Portadores de Fármacos , Humanos , Concentração Inibidora 50 , Espectrometria de Massas , Testes de Sensibilidade Microbiana , Minociclina/farmacocinética , Tigeciclina
7.
Ann R Coll Surg Engl ; 96(8): e23-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25350172

RESUMO

We report the case of an eradicated multiresistant Serratia marcescens prosthetic hip joint infection. It is estimated that enteric Gram-negative organisms account for approximately 8% of prosthetic joint infections. However, the evolving multiresistant strains of organisms being encountered in hospital acquired infections is making eradication increasingly difficult. We describe n our surgical and microbiological approach to this in a complex case.


Assuntos
Antibacterianos/uso terapêutico , Ciprofloxacina/uso terapêutico , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/microbiologia , Infecções por Serratia/tratamento farmacológico , Serratia marcescens/efeitos dos fármacos , Serratia marcescens/isolamento & purificação , Antibacterianos/farmacologia , Artroplastia de Quadril/efeitos adversos , Ciprofloxacina/farmacologia , Gentamicinas/farmacologia , Gentamicinas/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Infecções por Serratia/microbiologia
9.
J Bone Joint Surg Br ; 94(11): 1455-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23109621

RESUMO

Peri-prosthetic infection remains a leading cause of revision surgery. Recent publications from the American Musculoskeletal Infection Society have sought to establish a definition of peri-prosthetic infection based on clinical findings and laboratory investigations. The limitations of their approach are discussed and an alternative definition is proposed, which it is felt may better reflect the uncertainties encountered in clinical practice.


Assuntos
Artroplastia/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Reoperação , Humanos , Infecções Relacionadas à Prótese/cirurgia
10.
Antimicrob Agents Chemother ; 56(3): 1471-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22155831

RESUMO

The use of antibiotics as a supplement to bone cement for the purposes of providing a local release of antibiotics is common practice in arthroplasty surgery and the kinetics of elution of the antibiotics in such systems have been investigated previously. However, in these previous studies no account was taken of the potential effects that wear may have on the elution kinetics of the antibiotic. Here, we have modified an existing wear testing rig to allow the simultaneous study of the elution kinetics of bone cement samples containing antibiotics being subjected to immersion only and immersion and conjoint wear. The results show contrasting effects with two commonly used antibiotics. Bone cement containing daptomycin showed no substantial change in antibiotic elution due to wear, while cement containing gentamicin (the most commonly used antibiotic in this application) in contrast demonstrated a substantial reduction in the rate of antibiotic elution when wear was applied. Scanning electron microscopy revealed a possible explanation for these diverse results, due to wear-induced "sealing" of the surface in conjunction with the crystal morphology of the antibiotic.


Assuntos
Antibacterianos/química , Cimentos Ósseos/química , Daptomicina/química , Gentamicinas/química , Vancomicina/química , Acetatos , Artroplastia , Biomimética , Soluções Tampão , Cristalização , Difusão , Humanos , Cinética , Microscopia Eletrônica de Varredura
12.
J Bone Joint Surg Br ; 93(6): 844-6, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21586788

RESUMO

Intrapelvic migration of the acetabular component of a total hip replacement, with severe acetabular destruction making reconstruction impossible, is very rare. We present a patient in whom the component was removed using a laparotomy and a transperitoneal approach with subsequent salvage using a saddle prosthesis and a total femoral replacement.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Remoção de Dispositivo/métodos , Prótese de Quadril/efeitos adversos , Idoso , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Humanos , Pelve/diagnóstico por imagem , Peritônio/cirurgia , Falha de Prótese , Radiografia
13.
J Bone Joint Surg Br ; 92(6): 856-61, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20513885

RESUMO

Between 1988 and 1998 we implanted 318 total hip replacements (THRs) in 287 patients using the Plasmacup (B. Braun Ltd, Sheffield, United Kingdom) and a conventional metal-on-polyethylene articulation. The main indications for THR were primary or secondary osteoarthritis. At follow-up after a mean 11.6 years (7.6 to 18.4) 17 patients had died and 20 could not be traced leaving a final series of 280 THRs in 250 patients. There were 62 revisions (22.1%) in 59 patients. A total of 43 acetabular shells (15.4%) had been revised and 13 (4.6%) had undergone exchange of the liner. The most frequent indications for revision were osteolysis and aseptic loosening, followed by polyethylene wear. The mean Kaplan-Meier survival of the Plasmacup was 91% at ten years and 58% at 14 years. Osteolysis was found around 36 (17.1%) of the 211 surviving shells. The median annual rate of linear wear in the surviving shells was 0.12 mm/year and 0.25 mm/year in those which had been revised (p < 0.001). Polyethylene wear was a strong independent risk factor for osteolysis and aseptic loosening. The percentage of patients with osteolysis increased proportionately with each quintile of wear-rate. There is a high late rate of failure of the Plasmacup. Patients with the combination of this prosthesis and bearing should be closely monitored after ten years.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Adulto , Idoso , Artroplastia de Quadril/instrumentação , Cimentação , Métodos Epidemiológicos , Humanos , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Polietileno , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Resultado do Tratamento , Adulto Jovem
14.
J Bone Joint Surg Br ; 91(11): 1419-23, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19880883

RESUMO

Between 1990 and 2000, 123 hips in 110 patients were reconstructed for aseptic loosening using impaction bone grafting with frozen, irradiated, morsellised femoral heads and cemented acetabular components. This series was reported previously at a mean follow-up of five years. We have extended this follow-up and now describe the outcome of 86 hips in 74 patients at a mean of ten years. There have been 19 revisions, comprising nine for infection, seven for aseptic loosening and three for dislocation. In surviving acetabular reconstructions, union of the graft had occurred in 64 of 67 hips (95.5%). Survival analysis for all indications at ten years was 83.3% (95% confidence interval (CI) 68 to 89) and 71.3% (95% CI 58 to 84) at 15 years. Acetabular reconstruction using irradiated allograft and a cemented acetabular component is an effective method of reconstruction, providing results in the medium- to long-term comparable with those of reported series where non-irradiated freshly-frozen bone was used.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Transplante Ósseo/métodos , Cabeça do Fêmur/efeitos da radiação , Acetábulo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça do Fêmur/transplante , Seguimentos , Sobrevivência de Enxerto , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação/métodos , Análise de Sobrevida , Resultado do Tratamento
15.
J Bone Joint Surg Br ; 90(5): 574-8, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18450621

RESUMO

Between 1980 and 2000, 63 support rings were used in the management of acetabular deficiency in a series of 60 patients, with a mean follow-up of 8.75 years (2 months to 23.8 years). There was a minimum five-year follow-up for successful reconstructions. The indication for revision surgery was aseptic loosening in 30 cases and infection in 33. All cases were Paprosky III defects; IIIA in 33 patients (52.4%) and IIIB in 30 (47.6%), including four with pelvic dissociation. A total of 26 patients (43.3%) have died since surgery, and 34 (56.7%) remain under clinical review. With acetabular revision for infection or aseptic loosening as the definition of failure, we report success in 53 (84%) of the reconstructions. A total of 12 failures (19%) required further surgery, four (6.3%) for aseptic loosening of the acetabular construct, six (9.5%) for recurrent infection and two (3.2%) for recurrent dislocation requiring captive components. Complications, seen in 11 patients (18.3%), included six femoral or sciatic neuropraxias which all resolved, one grade III heterotopic ossification, one on-table acetabular revision for instability, and three early post-operative dislocations managed by manipulation under anaesthesia, with no further instability. We recommend support rings and morcellised bone graft for significant acetabular bone deficiency that cannot be reconstructed using mesh.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese , Acetábulo , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Cimentos Ósseos , Parafusos Ósseos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese , Reoperação
16.
J Bone Joint Surg Br ; 90(5): 643-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18450633

RESUMO

Bone cements produced by different manufacturers vary in their mechanical properties and antibiotic elution characteristics. Small changes in the formulation of a bone cement, which may not be apparent to surgeons, can also affect these properties. The supplier of Palacos bone cement with added gentamicin changed in 2005. We carried out a study to examine the mechanical characteristics and antibiotic elution of Schering-Plough Palacos, Heraeus Palacos and Depuy CMW Smartset bone cements. Both Heraeus Palacos and Smartset bone cements performed significantly better than Schering-Plough Palacos in terms of mechanical characteristics, with and without additional vancomycin (p < 0.001). All cements show a deterioration in flexural strength with increasing addition of vancomycin, albeit staying above ISO minimum levels. Both Heraeus Palacos and Smartset elute significantly more gentamicin cumulatively than Schering-Plough Palacos. Smartset elutes significantly more vancomycin cumulatively than Heraeus Palacos. The improved antibiotic elution characteristics of Smartset and Heraeus Palacos are not associated with a deterioration in mechanical properties. Although marketed as the 'original' Palacos, Heraeus Palacos has significantly altered mechanical and antibiotic elution characteristics compared with the most commonly-used previous version.


Assuntos
Antibacterianos/análise , Cimentos Ósseos/análise , Teste de Materiais , Polimetil Metacrilato/análise , Estresse Mecânico , Suporte de Carga/fisiologia , Artroplastia de Substituição , Gentamicinas/análise , Testes de Dureza , Humanos , Estatística como Assunto , Vancomicina/análise
17.
Strategies Trauma Limb Reconstr ; 3(1): 35-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18427922

RESUMO

We report a case of a 51-year-old lady, who underwent a femoral shortening using a fixator assisted blade plate after total hip replacement. The patient had a total hip replacement on the other side with previous revisions, which resulted in a leg length discrepancy. We used the above technique to control the shortening and preserve the mechanical and anatomical axis of the femur.

18.
J Bone Joint Surg Br ; 90(2): 145-8, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18256078

RESUMO

We present a series of 114 patients with microbiologically-proven chronically-infected total hip replacement, treated between 1991 and 2004 by a two-stage exchange procedure with antibiotic-loaded cement, but without the use of a prolonged course of antibiotic therapy. The mean follow-up for all patients was 74 months (2 to 175) with all surviving patients having a minimum follow-up of two years. Infection was successfully eradicated in 100 patients (87.7%), a rate which is similar to that reported by others, but where prolonged adjuvant antibiotic therapy has been used. Using the technique described, a prolonged course of systemic antibiotics does not appear to be essential and the high cost of the administration of antibiotics can be avoided.


Assuntos
Antibacterianos/administração & dosagem , Artroplastia de Quadril , Cimentos Ósseos/farmacologia , Prótese de Quadril , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/economia , Artroplastia de Quadril/métodos , Cimentos Ósseos/economia , Cimentos Ósseos/uso terapêutico , Feminino , Fidelidade a Diretrizes , Articulação do Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Resultado do Tratamento
19.
J Bone Joint Surg Br ; 89(1): 32-3, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17259412

RESUMO

Bleeding is a major complication of revision total hip replacement. We report a case where the inflated balloon of a urinary catheter was used to temporarily control intrapelvic bleeding from the superior gluteal artery, while definitive measures for endovascular embolisation were made.


Assuntos
Artroplastia de Quadril/efeitos adversos , Oclusão com Balão , Perda Sanguínea Cirúrgica/prevenção & controle , Cateterismo/métodos , Hemostasia Cirúrgica/métodos , Idoso , Artérias/lesões , Nádegas/irrigação sanguínea , Feminino , Humanos , Complicações Intraoperatórias/terapia , Reoperação/efeitos adversos , Cateterismo Urinário/instrumentação
20.
J Bone Joint Surg Br ; 89(1): 107-8, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17259426

RESUMO

We report a case of local compression-induced transient femoral nerve palsy in a 46-year-old man. He had previously undergone surgical release of the soft tissues anterior to both hip joints because of contractures following spinal injury. An MRI scan confirmed a synovial cyst originating from the left hip joint, lying adjacent to the femoral nerve. The cyst expanded on standing, causing a transient femoral nerve palsy. The symptoms resolved after excision of the cyst.


Assuntos
Neuropatia Femoral/etiologia , Paralisia/etiologia , Traumatismos da Medula Espinal/complicações , Cisto Sinovial/complicações , Contratura de Quadril/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Cisto Sinovial/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA