Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 271, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589829

RESUMO

BACKGROUND: Single limb support phase of the gait-cycle in patients who are treated for a pertrochanteric fracture is characterized by transversal loads acting on the lag screw, tending to block its dynamization. If the simultaneous axial force overcomes transversal loads of the sliding screw, the dynamization can still occur. METHODS: Biomechanical investigation was performed for three types of dynamic implants: Gamma Nail, and two types of Selfdynamizable Internal Fixators (SIF) - SIF-7 (containing two 7 mm non-cannulated sliding screws), and SIF-10 (containing one 10 mm cannulated sliding screw). Contact surface between the stem and the sliding screws is larger in SIF implants than in Gamma Nail, as the stem of Gamma Nail is hollow. A special testing device was designed for this study to provide simultaneous application of a controlled sliding screws bending moment and a controlled transversal load on sliding screws (Qt) without using of weights. Using each of the implants, axial forces required to initiate sliding screws dynamization (Qa) were applied and measured using a tensile testing machine, for several values of sliding screws bending moment. Standard least-squares method was used to present the results through the linear regression model. RESULTS: Positive correlation between Qt and Qa was confirmed (p < 0.05). While performing higher bending moments in all the tested implants, Qa was higher than it could be provided by the body weight. It was the highest in Gamma Nail, and the lowest in SIF-10. CONCLUSIONS: A larger contact surface between a sliding screw and stem results in lower forces required to initiate dynamization of a sliding screw. Patients treated for a pertrochanteric fracture by a sliding screw internal fixation who have longer femoral neck or higher body weight could have different programme of early postoperative rehabilitation than lighter patients or patients with shorter femoral neck.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur , Humanos , Parafusos Ósseos/efeitos adversos , Fenômenos Biomecânicos , Fixadores Internos , Fixação Interna de Fraturas , Fraturas do Fêmur/etiologia , Peso Corporal
2.
Unfallchirurgie (Heidelb) ; 127(3): 246-250, 2024 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-37801096

RESUMO

Fractures of the tibial pilon are severe injuries which can be accompanied by articular impaction, comminution and soft tissue injury. Soft tissue injury with already existing skin damage can further complicate the method of treatment. In these cases, the method of unilateral or circular external fixation can be used as an alternative method of treatment. Minimally invasive percutaneous osteosynthesis with spanning rigid and dynamic unilateral external fixation as a one-stage method has been used for the treatment of intra-articular pilon fractures. We report a case of a patient with an intra-articular pilon fracture with chronic venous insufficiency and venous ulcer, who was injured after falling from a height and who had emergency surgery based on capsuloligamentotaxis and percutaneous osteosynthesis with a spanning unilateral external fixator. The patient was mobilized postoperatively for walking without weight bearing on the injured leg. The initial rigid spanning external fixation was transformed into dynamic fixation to enable ankle joint movements 8 weeks after surgery. The external fixator was removed 4.5 months after surgery and the Kirschner wire and screws were removed 7 months after surgery. The final functional result 1 year after the injury was good and motion of upper ankle joint was moderately restricted without pain. Swelling occurred after walking for longer distances.


Assuntos
Traumatismos do Tornozelo , Fraturas Intra-Articulares , Lesões dos Tecidos Moles , Fraturas da Tíbia , Humanos , Resultado do Tratamento , Seguimentos , Fixadores Externos , Fixação de Fratura , Traumatismos do Tornozelo/cirurgia , Fraturas da Tíbia/diagnóstico por imagem
4.
Int Orthop ; 45(4): 1071-1076, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32740756

RESUMO

PURPOSE: Tibial plateau fractures are severe intra-articular injuries; their treatment is accompanied by numerous complications and requires extensive surgical experience. In this manuscript, we compared our experiences with data from the literature. METHODS: Retrospectively, we analyzed 41 patients with closed lateral tibial plateau fracture (Schatzker's I-III). All fractures were treated surgically with open reduction and internal plate fixation. Post-operative complications and final outcomes were monitored according to the Tegner Lysholm Knee Scoring System. The average follow-up was 5.7 years (2-10). RESULTS: We analyzed 41 patients (Schatzker I-III), average age 46.7 ± 13.0 years. Traumatic lesion of the lateral meniscus was present in 15 (36.58%) patients. Post-traumatic knee osteoarthritis was present in all (100%) patients after lateral meniscectomy and in 20% of patients it occurred after meniscus repair (p = 0.007). Post-traumatic knee osteoarthritis was present in 12 (29.68%) patients. Infection occurred in five (12.19%) patients, DVT in three (7.3%) patients, and we had one (2.43%) case of non-lethal PE. Final functional outcomes were excellent in 13 (31.7%), good in 21 (51.21%), moderate in five (12.19%), and poor in two (4.87%) patients. CONCLUSION: Lateral tibial plateau fractures are severe intra-articular injuries which can leave lasting consequences, regardless of the restoring of the articular surface and stable internal fixation. Local skin condition and associated soft tissue injuries, comminution, degree of dislocation, and depression can significantly affect the development of post-traumatic osteoarthritis and poor outcomes.


Assuntos
Fixação Interna de Fraturas , Fraturas da Tíbia , Adulto , Placas Ósseas , Fixação Interna de Fraturas/efeitos adversos , Humanos , Pessoa de Meia-Idade , Redução Aberta/efeitos adversos , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
5.
Int Orthop ; 45(4): 871-876, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32617652

RESUMO

PURPOSE: Acetabular fractures are accompanied by complications such as post-traumatic osteoarthritis (OA) of the hip and avascular necrosis (AVN) of the femoral head. The aim of the study was to evaluate improvement of life quality and functional recovery after total hip arthroplasty (THA) in patients with post-traumatic OA and AVN. METHODS: We retrospectively reviewed 23 patients with post-traumatic OA of the hip and AVN of the femoral head who undergone THA, out of 63 patients who were previously surgically treated for acetabular fractures. Final functional outcomes are defined according to the Merle d'Aubigné score, and the pain intensity according to VAS from 0 to 10. RESULTS: Out of 63 patients with acetabular fractures from 2008 to 2018, we analyzed 23 (36.5%) patients, with an average age of 51.5 ± 13.8 years, who required THA due to post-traumatic OA and AVN of the femoral head. THA was done after the average of 4.28 years (range 1 to 8) from previous acetabular osteosynthesis. According to Merle d'Aubigné score, final functional outcomes before THA were moderate with average points of 4.86 (4-6). Post-THA final functional outcomes were excellent with an average point of 10.04 (10-12) (p < 0.001). The ratio of VAS before and after THA was 9.04:1.95(p < 0.001). CONCLUSION: THA is a method which gives the best results in the treatment of post-traumatic OA of the hip and AVN of the femoral head after previous osteosynthesis of the acetabular fracture. After THA, life quality and functional status of a patient are significantly improved.


Assuntos
Artroplastia de Quadril , Acetábulo/cirurgia , Adulto , Idoso , Artroplastia de Quadril/efeitos adversos , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
6.
Vojnosanit Pregl ; 74(1): 51-3, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29350891

RESUMO

Background/Aim: Fitmore® hip stem belongs to the group of short stem prostheses with the metaphysar stabilization, with its shape and form that protects the bone mass in the greater trochanter region and the distal part of the femur. The aim of this paper was to present the early postoperative results in patients with implanted Fitmore® hip stem and point out some of the advantages. Methods: A series of 10 patients with implanted Fitmore® hip stem, was included in this study. The average age of the patients was 54.5 (48­65) years. There were 5 women and 5 men. The total monitoring time was 16 months. To rate the condition of the hip joint we used The Western Ontario and Mc Master Universities Arthritis Index (WOMAC) score. We also monitored the degree of hip pain, hip flexion, heterotopic ossification and indentation in the stem of the prosthesis. Results: After 12 months of monitoring 9 (90%) of the patients had no pain in the thigh region, and only 1 (10%) experienced mild pain. The hip flexion rose from the average 89° to postoperative 114°. WOMAC score rose as well, from 49 to 94 average points. Indentation in the stem was registered 3 months after the operation in 2 (20%) of the patients ­ in one of the patients the indentation was 3 mm and in the other patient 5 mm. After the 16-month monitoring, the results were excellent. The monitoring period was short though it should be continued and the results should be presented after 5 and then after 10 years. Conclusion: Early results of the implantation Fitmore stem showed good bone ingrowth with excellent functional result.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Avaliação da Deficiência , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
7.
Srp Arh Celok Lek ; 144(5-6): 293-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29648747

RESUMO

Introduction: Open lower leg fractures are the most common open fractures of the locomotor system and their treatment is associated with a number of complications. Objective: The aim of the paper was to present the results of the treatment of 68 patients with open lower leg fractures, as well as the complications that accompany the treatment of these fractures. Methods: In the analyzed group, there were 45 (66.18%) men and 23 (33.82%) women. The majority of patients ­ 33 (48.53%) of them ­ were injured in motor vehicle accidents, whereas 24 (35.29%) patients sustained injuries due to falls from heights. In two (2.94%) patients the cause of open tibial fractures was gunshot injuries. In the analyzed group, there were 18 (26.47%) type I open fractures, 21 (30.88%) type II open fractures, 19 (27.94%) type IIIA open fractures, seven (10.29%) type IIIB open fractures, and three (4.41%) type IIIC open fractures. Results: The tibial shaft fracture healed without serious complications in 50 (73.53%) patients, whereas in 18 (26.47%) patients we observed some complications. Nonunion was found in 10 (14.71%) patients, osteitis in four (5.88), malunion in two (2.94%) patients. Milder complications such as soft tissue pin tract infection developed in 13 (19.12%) patients, infection of the open fracture wound soft tissue was observed in four (5.88%) patients. Conclusion: Basic principles in the treatment of open lower leg fractures in this study are thorough primary open fracture wound treatment followed by the delayed wound closure, stable fracture fixation using unilateral external skeletal device, proper antibiotic treatment and tetanus prophylaxis. The results correlate with similar studies.


Assuntos
Fixadores Externos , Fraturas Expostas/cirurgia , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fixadores Externos/efeitos adversos , Feminino , Consolidação da Fratura , Fraturas Expostas/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
8.
Ann Ital Chir ; 86(2): 148-55, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25952608

RESUMO

UNLABELLED: arthroplasty (TKA) patients and to determine the association of fear of movement with established outcome measures. METHODS: A prospective study included 78 patients with primary TKA for osteorthritis. The occurence of fear of movement was assessed by Tampa Scale of Kinesiophobia (TSK). The patients were assessed at three time points: 2 weeks, 4 weeks and 6 months after the surgery. Pain and flexion were measured at all the three time points while function according to the Oxford knee score 1 was evaluated only at 6 month after surgery. RESULTS: Fear of movement occurred in 17 patients (21.8%). Patients with a high degree of fear of movement showed significantly poorer results compared to those with a low degree in terms of pain, flexion and function. Improvement in pain and flexion over time was achieved in both groups but it was significantly greater in the low degree fear of movement group. DISCUSSION: Our study showed that postoperative fear of movement was significantly associated with pain, flexion and function. Other authors found that preoperative level of fear of movement was a predictor of postoperative functional limitations. CONCLUSIONS: Fear of movement occurred in a substantial proportion of patients after TKA and it was associated with knee pain, flexion and function. According to our results fear of movement may represent a risk for poor TKA outcome.


Assuntos
Artroplastia do Joelho/psicologia , Medo/psicologia , Osteoartrite , Amplitude de Movimento Articular , Idoso , Artroplastia do Joelho/métodos , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/psicologia , Osteoartrite/cirurgia , Dor/psicologia , Período Pós-Operatório , Estudos Prospectivos , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Inquéritos e Questionários , Resultado do Tratamento
9.
Vojnosanit Pregl ; 72(2): 181-4, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25831912

RESUMO

INTRODUCTION: Most scapular fractures are caused by high-impact blunt injuries, often as the result of motor vehicle accidents, fall from height, etc. In 80% to 90% of cases, scapula fractures are associated with multiple injuries (clavicle fracture, rib fractures, humeral fracture, pulmonary injury, brachial plexus injury). CASE REPORT: We presented scapular fracture in a 27-years-old male who had sustained a work-related injury when a ground soil brick machine pressed him. Fracture line was identified on radiotherapy and computed tomography scan from the distal scapular angle enclosing scapular neck. The whole lateral part of the scapula was dislocated laterally from the scapular body. Scapular fracture was treated operatively. The posterior approach was used for reposition, while for fixation after reposition we used two Blunt clamps. We presented functional outcome 22 years after the injury and the surgical treatment. The patient can perform all physical activities, still works, and there is no need to remove the ostheosynthetic material as it causes no discomfort nor problems. The strength of the shoulder muscles is estimated as physician as the grade 5. CONCLUSION: Displaced intra- articular fractures of the scapula should be treated operatively, with open reduction and internal fixation.


Assuntos
Fraturas Ósseas/cirurgia , Escápula/cirurgia , Luxação do Ombro/cirurgia , Adulto , Seguimentos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Avaliação de Resultados da Assistência ao Paciente , Radiografia , Escápula/diagnóstico por imagem , Escápula/lesões , Luxação do Ombro/diagnóstico por imagem , Fatores de Tempo
10.
Vojnosanit Pregl ; 72(11): 1004-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26731975

RESUMO

BACKGROUND/AIM: Arthrosis of the hip is the most common cause of a hip joint disorders. The aim of this study was to present our experience in the application of a safe surgical dislocation of the hip in patients with minor morphological changes in the hip joint, which, through the mechanism of femoroacetabular impingement, cause damage to the acetabular labrum and adjacent cartilage as an early sign of the hip arthrosis. METHODS: We have operated 51 patients with different morphological bone changes in the hip area and resultant soft tissue damage of the acetabular labrum and its adjacent cartilage. Surgical technique that we applied in this group of patients, was. adapted to our needs and capabilities and it was minimaly modified compared to the original procedure. RESULTS: The surgical technique presented in this paper, proved to be a good method of treatment of bone and soft tissue pathomorphological changes of the hip in patients with femoroacetabular impingement. We had no cases with avascular necrosis of the femoral head, and two patients had nonunion of the greater trochanter, 9 patients developed paraarticular ossification, without subjective symptoms, while 3 patients suffered from postoperative pain in the groin during more energetic physical activities. CONCLUSION: Utilization of our partly modified surgical technique of controlled and safe dislocation of the hip can solve all the bone and soft tissue problems in patients with femoroacetibular impingement to stop already developed osteoarthritis of the hip or to prevent mild form of it.


Assuntos
Impacto Femoroacetabular/cirurgia , Procedimentos Ortopédicos/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Resultado do Tratamento
11.
Vojnosanit Pregl ; 72(12): 1132-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26898040

RESUMO

INTRODUCTION: Minimal bone changes in the acetabulum and/or proximal femur, through mechanism known as femoroacetabular impingement, during flexion, adduction and internal rotation lead to early contact between femoral head-neck junction and acetabular brim, in anterosuperior region. Each additional pathological substrate which further decreases specified clearance provokes earlier onset of femoroacetabular impingement symptoms. CASE REPORT: We presented a 20-year-old male patient with groin pain, limping, positive impingement test, radiological signs of mixed form of femoroacetabular impingement and unrecognized chronic hypertrophic synovitis with earlier development of clinical hip symptoms than it has been expected. Open surgery of the left hip was done. Two years after the surgery, patient was asymptomatic, painless, and free of motion, with stable x-rays. CONCLUSION: Hypertrophic synovial tissue further reduces the distance between the femoral head-neck junction and the acetabulum, leading to the earlier onset of femoroacetabular impingement symptoms. Surgical treatment is the method of choice.


Assuntos
Impacto Femoroacetabular/diagnóstico , Articulação do Quadril , Sinovite/diagnóstico , Fenômenos Biomecânicos , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/fisiopatologia , Impacto Femoroacetabular/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Radiografia , Recuperação de Função Fisiológica , Sinovite/diagnóstico por imagem , Sinovite/fisiopatologia , Sinovite/cirurgia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Acta Chir Iugosl ; 60(2): 41-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24298737

RESUMO

The aim of this study is to describe the nature of war wounds with fracture caused by cluster bombs and to suggest treatment options for such injuries. The nature of wounds caused by cluster bombs differs from those caused by conventional arms (they are more severe). The sides of the wounds are represented by conquasated soft tissues (such as fat and muscle) with thick dead tissues, ordinarily with a thickness of 0.5-4.5 cm. Another main characteristic of such injuries is the high percentage of amputations needed due to the high rate of neurovascular damage. This paper investigates the cases of 81 patients who sustained a total of 99 war wounds with fractures. The average age of the patients was 32.7 years while the youngest was 20 and the oldest, 77. According to The International Committee of the Red Cross (ICRC) classification of war wounds, 14 patients had grade I injuries, 48 patients grade II, and 29 patients, grade III. Mitkovic external fixation system, known also as the "War Fixator" was used for all fractures fixation. One protocol, which was a modification of the ICRC's protocol adapted to our specific conditions, was used throughout the study. For solving soft tissue defects, a rotator fasciocutan flap was the most frequently used. For solving of bones defect Mitkovic reconstructive external fixation device was used. All fractures we treated healed. We concluded that shortening the procedural time and being a very simple, immediate using of Mitkovic versatile external fixator ("War Fixator") is, leads to desirable results.


Assuntos
Traumatismos por Explosões/cirurgia , Fixadores Externos , Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Traumatismo Múltiplo/cirurgia , Lesões dos Tecidos Moles/cirurgia , Adulto , Idoso , Amputação Cirúrgica , Bombas (Dispositivos Explosivos) , Desbridamento , Feminino , Fixação de Fratura/instrumentação , Fixação Interna de Fraturas/instrumentação , Fraturas Expostas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Sérvia , Retalhos Cirúrgicos , Índices de Gravidade do Trauma , Guerra , Adulto Jovem
13.
Acta Chir Iugosl ; 60(2): 59-64, 2013.
Artigo em Sérvio | MEDLINE | ID: mdl-24298740

RESUMO

Proper timing and surgical method in management of femur fractures in polytrauma patients can greatly reduce the mortality, morbidity and disability. The aim of this paper is to present the treatment of bilateral femoral fractures in polytrauma patient with dominant chest trauma by selfdynamisable internal fixator Mitkovic (SIF) as a definitive method of fractures treatment. A 23 years old female was injured in a traffic accident. After resuscitation and treatment of the dominant chest injuries, surgical treatment of bilateral femur fractures performed on the fourth day after the injury. Length of surgery was 65 minutes. There was not blood substitution during the intervention and blood loss through the operative wounds drainage. There was no worsening of the pulmonary function after orthopaedic surgery. The patient discharged from hospital postoperative day ten. Postoperative follow-up was 9 months. The fractures healed with an excellent functional result. Application of selfdynamisable internal fixator (SIF) with minimally invasive technique for the treatment of bilateral femoral fractures in polytrauma patients is a good operative method because poses minimally additional operative trauma and provides excellent biomechanical conditions for fracture healing.


Assuntos
Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fixadores Internos , Traumatismo Múltiplo/cirurgia , Feminino , Fixação Interna de Fraturas/métodos , Consolidação da Fratura , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Traumatismos Torácicos/terapia , Adulto Jovem
14.
Acta Chir Iugosl ; 60(2): 65-9, 2013.
Artigo em Sérvio | MEDLINE | ID: mdl-24298741

RESUMO

INTRODUCTION: Acetabular fractures are severe injuries, mostly occured in young patients after traffic accident or fall from heights. Of the all acetabular fractures, posterior wall acetabular fractures are the most often observed. Regarding to mechanism of the injury, about 30% of these fractures are associated with posterior hip dislocation. MATERIAL AND METHODS: The incidence of AVN in 18 patients with posterior wall acetabular fractures associated with dislocations of the hip is presented. Thompson-Epstein Scale (type I-V) was used as the classification of the injury. Kocher-Langenbeck surgical approach was achieved in all patients. RESULTS: Average following time after surgery was 22, 66 months (8-36 months). After that period the incidence of femoral head AVN was observed in 33.3%. Femoral head AVN was observed in 5.55% of patient who was treated by the reduction of hip dislocation in first 24 hours after injury, while in patients with later reduction, femoral head AVN were observed in 27.77%. CONCLUSION: Posterior wall acetabular fractures associated with hip dislocation are severe injuries. Urgent, closed reduction of the hip, early definitive stable osteosynthesis of acetabulum and the experience of surgical team are factors that greatly decrease the possibility for AVN occurence. Later reduction, comminution of posterior wall of the acetabulum (Thompson- Epstein III et IV), impaction, chondral lesion of the femoral head and associated fractures of femoral head, increase the possibility for AVN occurence.


Assuntos
Acetábulo/lesões , Necrose da Cabeça do Fêmur/etiologia , Fraturas Ósseas/complicações , Luxação do Quadril/complicações , Adulto , Feminino , Fraturas Ósseas/cirurgia , Luxação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Tempo para o Tratamento , Adulto Jovem
15.
Acta Chir Iugosl ; 60(2): 103-8, 2013.
Artigo em Sérvio | MEDLINE | ID: mdl-24298747

RESUMO

The main goal of this paper is to present clinical results of surgical correction of angular (varus and valgus) deformities of knee area. Goal is also to present new external fixation device for surgical treatment of varus deformity of proximal tibia. As material it has been used series of 70 patients treated during the period of 6.5 years in University Orthopaedic and traumatology clinic. Biomechanical investigation of 80% cut bone model fixed by new external fixation device was performed in the measurement laboratory of Mechanical Faculty University of Nis. Clinical results of treatment of 58 high tibial surgeries (49 varus and 9 valgus) and 12 distal femur surgeries (2 varus and 10 valgus) showed that unicorticotomy and callus distraction by the use of Mitkovic external fixation device leaded to correction and bone union. Superficial pin tract infection happened in 9 patients and has been successfully treated without pins removal. Biomechanical investigation of new device showed that during axial loading of bone model by 690 N (70 kg) movement of medial distal end of bone model was 0.30 mm while posterior distal end of bone model was 0.26 mm. From results obtained in can be concluded that unicorticotomy and gradual callus distraction by the use of external fixation is one reliable method. Biomechanical testing of new external fixation device showed that it is more stable in control of varus and posterior position of proximal tibial fragment.


Assuntos
Fixadores Externos , Fêmur/anormalidades , Técnica de Ilizarov/instrumentação , Articulação do Joelho/anormalidades , Tíbia/anormalidades , Fenômenos Biomecânicos , Pinos Ortopédicos , Feminino , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Masculino , Osteotomia , Tíbia/cirurgia
16.
Srp Arh Celok Lek ; 141(9-10): 615-22, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24364223

RESUMO

INTRODUCTION: The importance of vitamin D on bone health and osteoporosis was studied by many researchers. The main role of the Vitamin D is to absorb calcium and phosphate and increase bone mineralization. Older people are at an increased risk of the inadequate vitamin D production in the skin because of lower sun exposure and reduced ability of the skin to synthesize vitamin D. OBJECTIVE: The aim of this clinical trial was to evaluate the efficacy and tolerability of short-term (2 weeks) low energy UVB irradiation in postmenopausal women with osteoporosis using bone mineral density and bone turnover markers. METHODS: A three-month, single-blinded, randomized, placebo-controlled clinical trial was conducted at the University hospital in Daegu, Republic of Korea. Fifty-two postmenopausal Korean women (older than 65 years) with osteoporosis were randomly allocated to have either low energy UVB or placebo for 30 minutes a day for two weeks of treatment during winter. Laboratory analysis and physical examination before and 4, 8 and 12 weeks after treatment were carried out and BMD was measured before and 8 and 12 weeks after treatment. The effects of time and treatment interaction between these two groups were evaluated by repeated-measure two-factor analysis, and subgroup analysis was performed to examine UVB effect on the vitamin D insufficient group [serum 25(OH)D3 concentration < 30 ng/mL]. RESULTS: In vitamin D insufficient group, the effect of UVB irradiation on vitamin D and bone ALP as well as additional benefit on bone formation was confirmed. The vitamin D insufficient group showed statistically significant increment in serum 25(OH)D3 compared with the normal group (p < 0.05). However, there was no significant difference between two groups in the other bone turnover markers, such as serum calcium, PTH-C, serum osteocalcin, serum CTX and BMD. CONCLUSION: Low-energy-short-term UVB radiation for postmenopausal women may be of use in vitamin D synthesis. There was a modest benefit in change of bone ALP especially in women with the insufficient vitamin D.


Assuntos
Densidade Óssea/efeitos dos fármacos , Remodelação Óssea/efeitos da radiação , Osteoporose Pós-Menopausa/radioterapia , Terapia Ultravioleta , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Osteoporose Pós-Menopausa/sangue , Método Simples-Cego , Vitamina D/sangue
17.
Srp Arh Celok Lek ; 141(9-10): 693-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24364237

RESUMO

INTRODUCTION: Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. CASE OUTLINE: A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. CONCLUSION: Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.


Assuntos
Fixação de Fratura/métodos , Fraturas Expostas/cirurgia , Osteogênese por Distração , Fraturas da Tíbia/cirurgia , Ferimentos por Arma de Fogo/cirurgia , Adulto , Fixadores Externos , Fixação de Fratura/instrumentação , Consolidação da Fratura , Fraturas Expostas/etiologia , Fraturas Expostas/patologia , Humanos , Masculino , Fraturas da Tíbia/etiologia , Fraturas da Tíbia/patologia , Ferimentos por Arma de Fogo/patologia
18.
Vojnosanit Pregl ; 70(2): 182-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23607186

RESUMO

BACKGROUND: Large defects of the abdominal wall caused by incisional hernia still represent a challenging problem in plastic, reconstructive, and abdominal surgery. For their successful tension-free repair a proper selection of reconstructive material is essential. In the last decades, the use of synthetic meshes was dominant while biological autodermal grafts were rarely used. The aim of the study was to comparatively analyse efficacy and safety of autodermal graft and polypropylene mesh in surgical treatment of large abdominal wall defects. METHODS: This prospective comparative clinical study enroled 40 patients surgically treated for large incisional hernia repair in a 10-year period. The patients were divided into two equal groups consisting of 20 subjects and treated either by biological autodermal graft or by synthetic polypropylene mesh. The surgical techniques of reconstruction, duration of surgery, the occurrence of early, minor, and major (severe) and delyed complications and hospital stay were analysed. The average follow-up took 2 years. RESULTS: Statistically significant differences in demographic characteristics of patients and in size of defects were not found. The surgical technique of reconstruction with an autodermal graft was more complicated. The duration of surgery in patients treated with autodermal grafts was significantly longer. There was no statistically significant difference regarding occurrence of early, minor postoperative complications and hospital stay in our study. Two severe complications were registered in the synthetic mesh group: intestinal obstruction and enterocutaneous fistula. The recurrence rate was 10% in the autodermal graft group and 15% in the group with a synthetic mesh. CONCLUSION: Tension-free repair of large incisional hernia with autodermal grafts was unjustly neglected despite the fact that it is safe and effective. It can be applied in all cases where synthetic mesh are not indicated (presence of infection, immunodeficient patients, after radiotherapy). They are especially important in war surgery and in lack of funds when commercial grafts cannot be purchased.


Assuntos
Parede Abdominal/cirurgia , Hérnia Abdominal/cirurgia , Transplante de Pele , Telas Cirúrgicas , Adulto , Idoso , Feminino , Hérnia Abdominal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade
19.
Srp Arh Celok Lek ; 140(7-8): 515-20, 2012.
Artigo em Sérvio | MEDLINE | ID: mdl-23092041

RESUMO

INTRODUCTION: The missiles of modern firearms can cause severe fractures of the extremity. High velocity missile fractures of the tibia are characterized by massive tissue destruction and primary contamination with polymorphic bacteria. Treatment of these fractures is often complicated by delayed healing, poor position healing, nonhealing and bone tissue infection. CASE OUTLINE: We present the management of tibial nonunion after wounding by high velocity missile and primary treatment by external fixation in a 25-year-old patient. The patient was primarily treated with external fixation and reconstructive operations of the soft tissue without union of the fracture. Seven months after injury we placed a compression-distraction external fixator type Mitkovic and started with compression and distraction in the fracture focus after osteotomy of the fibula and autospongioplasty. We recorded satisfactory fracture healing and good functional outcome. CONCLUSION: Contamination and devitalization of the soft-tissue envelope increase the risk of infection and nonunion in fractures after wounding by high velocity missile. The use of the compression-distraction external fixator type Mitkovic may be an effective method in nonunions of the tibia after this kind of injury.


Assuntos
Fraturas não Consolidadas/cirurgia , Fraturas da Tíbia/cirurgia , Ferimentos por Arma de Fogo/cirurgia , Adulto , Fixadores Externos , Consolidação da Fratura , Humanos , Traumatismos da Perna/cirurgia , Masculino , Lesões dos Tecidos Moles/cirurgia , Fraturas da Tíbia/etiologia , Ferimentos por Arma de Fogo/complicações
20.
Work ; 41 Suppl 1: 3207-12, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22317205

RESUMO

This paper presents a case study which confirmed that the use of APJ for proper assessment of human error in the Electric Power Company of Serbia (hereinafter EPS). The proposal methodological framework was used for human error identification and quantification in the case of a repair intervention on a steel lattice tower 10/0.4 kV (jurisdiction of an EPS subsidiary ED "Jugoistok", Nis, Serbia) which resulted in an accident with a fatal outcome. One of the aims of this study is to show the necessity of human error assessment not only in manufacturing industries but, as it will be shown in this paper, in companies that distribute electric energy, as well.


Assuntos
Acidentes de Trabalho , Centrais Elétricas , Probabilidade , Humanos , Julgamento , Medição de Risco , Sérvia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA