Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Investig Health Psychol Educ ; 12(1): 42-49, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35049533

RESUMO

The first aim of this study was to compare body mass index (BMI) (indirect method) classification with the body fat percent (PBF) (direct method) and to determine how BMI classifies subjects with different levels of skeletal muscle mass percent (PSMM). The second aim was to determine the prevalence of overweight and obesity status among police trainees (PTs). A total of 103 male PTs participated in this research: age = 21.46 ± 0.64 years, body mass (BM) = 75.97 ± 8.10 kg, body height (BH) = 174.07 ± 6.31 cm, BMI = 25.05 ± 2.12 kg/m2. The InBody 370 multichannel bioelectrical impedance analysis (BIA) measured body composition. Study results indicated that muscular PTs could be misclassified as overweight and that PBF identified more subjects as obese. Namely, three PTs were obese according to BMI, while 13 were obese according to PBF. The information provided by this research could be used to help professionals understand the importance of measuring body composition, and the inaccuracies in BMI classification. In conclusion, whenever possible PSMM and PBF should replace the utilization of BMI to screen overweight and obesity in PTs. Agencies may think of using BIA as non-invasive, quick and inexpensive measurement tool.

2.
J Strength Cond Res ; 35(3): 826-832, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30335715

RESUMO

ABSTRACT: Cvorovic, A, Kukic, F, Orr, RM, Dawes, JJ, Jeknic, V, and Stojkovic, M. Impact of a 12-week postgraduate training course on the body composition and physical abilities of police trainees. J Strength Cond Res 35(3): 826-832, 2021-The main objective of this study was to determine the effects of a 12-week physical training program on police trainees at the Abu Dhabi Police College. Anthropometric and fitness testing data for 325 healthy trainees, enrolled in an academic course for qualification as a police officer, were analyzed. The trainees were tested 3 times, during the initial (week 1), midpoint (week 7), and final testing (week 13) phases of the training program. The tested variables included anthropometry (body mass [BM]), body composition (body mass index [BMI]; waist circumference [WC]; waist-to-height ratio [WHtR]), upper-body muscular endurance (1-minute push-up [PU]), trunk muscular endurance (1-minute sit-up [SU]), and aerobic endurance (2.4-km run [RUN]). A 1-way analysis of variance with post hoc Bonferroni adjustment was performed to investigate the changes in anthropometry and fitness across the 3 testing periods with percentages of change calculated at each testing stage. Alpha levels were set at 0.05 a priori. Statistically significant differences (range of p values from p < 0.001 to p < 0.05) were found in all tested variables (BM, BMI, WC, WHtR, PU, SU, and RUN) and between all testing stages (initial, midpoint, and final). A progressive physical training program that incorporates mesocycles and midpoint evaluations can have a positive impact on the fitness of trainees even when undergoing a busy academy program.


Assuntos
Aptidão Física , Polícia , Composição Corporal , Índice de Massa Corporal , Teste de Esforço , Humanos , Resistência Física , Circunferência da Cintura
3.
J Healthc Eng ; 2020: 6689961, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33299535

RESUMO

The paper reports on the importance of applying the holistic approach in designing a personalized bone scaffold, but also all other kinds of personalized implants. In addition, the paper attempts to point out the important aspects of the design of a PBS against which the quality of a realistic and applicable design solution should be assessed. The holistic approach refers to the adaptation of design features of a bone scaffold to the multilateral specifics related to the particular patient, its surgical case, and curing treatment. To ensure a successful application, five aspects of personalized bone scaffold design should be considered while it is being adapted: anatomical congruency, mechanical conformity, biochemical compatibility and biodegradability, manufacturability, and implantability. To demonstrate the importance of applying a holistic approach in designing a personalized bone scaffold, the paper shows a case where a patient-specific scaffold aimed at the reconstruction of a large missing piece of mandible was designed. The research resulted in a series of recommendations regarding the methods of bone geometry reconstruction and scaffold design. The paper sheds new light on the desired mechanical properties of a personalized bone scaffold while also recommending possible design parameters for optimizing the construction according to these properties. Finally, it recommends a possible procedure of integral production of personalized bone scaffold and bone graft. The presented so-called holistic approach announces a new systematic process of designing a personalized bone scaffold, which, although requiring a comprehensive consideration of complex requirements, is inevitable to make the designed solution applicable.


Assuntos
Mandíbula , Procedimentos de Cirurgia Plástica , Transplante Ósseo , Humanos , Mandíbula/cirurgia , Próteses e Implantes
4.
Vojnosanit Pregl ; 67(10): 839-46, 2010 Oct.
Artigo em Sérvio | MEDLINE | ID: mdl-21066876

RESUMO

BACKGROUND/AIM: Reconstruction of lost, damaged or distorted mandibular bone presents a challenge from the functional side, as well as from the esthetic point of view. The aim of this study was to determinate potential differences between values of the basic linear moprhometric parameters (LMPs) obtained by direct and indirect manual measurement of the same humane mandibles, with accuracy testing of indirect measurement, which are routinely used in every-day clinical practice. The results are essential for defining of parametric model of the "standard mandible" and virtual modeling of the humane mandible in future researches as well as in clinical medicine. METHODS: A total number of 12 dry bony mandibles of human adults were studied. According to the standard anatomical landmarks, 10 standard LPMs were measured on each mandible by different manual methods: directly by a sliding caliper with nonius, and indirectly using standard software on two-dimensional (2D) reconstructions of mandibular multislice computed tomography (MSCT) scans. The values obtained by the different measuring methods were matched for the same LMPs. RESULTS: Statistically significant differences between compared LMPs values obtained by different measuring methods, appeared in the gnathio-interdental distance (Gn-IdD), as well as in the gnathio-condylar distance (Gn-CoD), bilaterally. In both parameters, significantly higher mean values (with percent of difference) were obtained by direct versus indirect measurement: Gn-IdD (21.57%; 29.2 mm vs 22.9 mm; p = 0.004); Gn-CoD left side (14.1%; 122.7 mm vs 105.4 cm; p = 0.001); Gn-CoD right side (11.87%; 124.7 mm vs 109.9 mm; p = 0.009). CONCLUSION: According to the observed inaccuracy of indirect measurement, we recommended the use of a correction factor for calculation of both Gn-IdD and Gn-CoD real vales, in defining of parametric model of the "standard mandible" based on indirect morphometry on 2D reconstructions of mandibular MSCT scans. Additional studies with larger number of specimens and quantification of anatomical variations regarding to sex, age, dentition status and ethnic origin, additionally should increase measurement accuracy and consequently reliability of future parametric model of the human mandible.


Assuntos
Mandíbula/anatomia & histologia , Mandíbula/diagnóstico por imagem , Adulto , Antropometria/métodos , Bromoexina , Humanos , Radiografia
5.
Australas Phys Eng Sci Med ; 33(3): 243-50, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20821359

RESUMO

The paper presents a case where an implant for a part of the sternum (with costal cartilages) affected by cancer was created and implanted by using the specific reverse modeling method and solid free-form fabrication. The method provides surgeons with a fast and reliable tool for tissue engineering and implantation and therefore improves the quality of life for patients. Digital images of healthy sternum samples were used to develop a reverse modeling algorithm that semi-automatically generates a necessary and sufficient simplification of the tissue geometry to be fabricated in an inexpensive and applicable manner. In this particular case, the redesign of the missing part of the sternum in CAD software took three designer-hours. At the same time, the suitable simplification of the geometry affects the fabrication of simpler and less expensive casting molds. Furthermore, the core of the developed algorithm for the reverse modeling of sternum can be applied in the reverse modeling improvement of other tile (or plate-like) bones.


Assuntos
Modelos Anatômicos , Próteses e Implantes , Desenho de Prótese , Esterno/anatomia & histologia , Esterno/cirurgia , Algoritmos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/cirurgia , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Esterno/diagnóstico por imagem , Engenharia Tecidual , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA