Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Methods Inf Med ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38262476

RESUMO

OBJECTIVES: In this paper, an artificial intelligence-based algorithm for predicting the optimal contrast medium dose for computed tomography (CT) angiography of the aorta is presented and evaluated in a clinical study. The prediction of the contrast dose reduction is modelled as a classification problem using the image contrast as the main feature. METHODS: This classification is performed by random decision forests (RDF) and k-nearest-neighbor methods (KNN). For the selection of optimal parameter subsets all possible combinations of the 22 clinical parameters (age, blood pressure, etc.) are considered using the classification accuracy and precision of the KNN classifier and RDF as quality criteria. Subsequently, the results of the evaluation were optimized by means of feature transformation using regression neural networks (RNN). These were used for a direct classification based on regressed Hounsfield units as well as preprocessing for a subsequent KNN classification. RESULTS: For feature selection, an RDF model achieved the highest accuracy of 84.42% and a KNN model achieved the best precision of 86.21%. The most important parameters include age, height, and hemoglobin. The feature transformation using an RNN considerably exceeded these values with an accuracy of 90.00% and a precision of 97.62% using all 22 parameters as input. However, also the feasibility of the parameter sets in routine clinical practice has to be considered, because some of the 22 parameters are not measured in routine clinical practice and additional measurement time of 15 to 20 minutes per patient is needed. Using the standard feature set available in clinical routine the best accuracy of 86.67% and precision of 93.18% was achieved by the RNN. CONCLUSION: We developed a reliable hybrid system that helps radiologists determine the optimal contrast dose for CT angiography based on patient-specific parameters.

2.
J Cardiovasc Magn Reson ; 25(1): 22, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36978131

RESUMO

BACKGROUND: Different software programs are available for the evaluation of 4D Flow cardiovascular magnetic resonance (CMR). A good agreement of the results between programs is a prerequisite for the acceptance of the method. Therefore, the goal was to compare quantitative results from a cross-over comparison in individuals examined on two scanners of different vendors analyzed with four postprocessing software packages. METHODS: Eight healthy subjects (27 ± 3 years, 3 women) were each examined on two 3T CMR systems (Ingenia, Philips Healthcare; MAGNETOM Skyra, Siemens Healthineers) with a standardized 4D Flow CMR sequence. Six manually placed aortic contours were evaluated with Caas (Pie Medical Imaging, SW-A), cvi42 (Circle Cardiovascular Imaging, SW-B), GTFlow (GyroTools, SW-C), and MevisFlow (Fraunhofer Institute MEVIS, SW-D) to analyze seven clinically used parameters including stroke volume, peak flow, peak velocity, and area as well as typically scientifically used wall shear stress values. Statistical analysis of inter- and intrareader variability, inter-software and inter-scanner comparison included calculation of absolute and relative error (ER), intraclass correlation coefficient (ICC), Bland-Altman analysis, and equivalence testing based on the assumption that inter-software differences needed to be within 80% of the range of intrareader differences. RESULTS: SW-A and SW-C were the only software programs showing agreement for stroke volume (ICC = 0.96; ER = 3 ± 8%), peak flow (ICC: 0.97; ER = -1 ± 7%), and area (ICC = 0.81; ER = 2 ± 22%). Results from SW-A/D and SW-C/D were equivalent only for area and peak flow. Other software pairs did not yield equivalent results for routinely used clinical parameters. Especially peak maximum velocity yielded poor agreement (ICC ≤ 0.4) between all software packages except SW-A/D that showed good agreement (ICC = 0.80). Inter- and intrareader consistency for clinically used parameters was best for SW-A and SW-D (ICC = 0.56-97) and worst for SW-B (ICC = -0.01-0.71). Of note, inter-scanner differences per individual tended to be smaller than inter-software differences. CONCLUSIONS: Of all tested software programs, only SW-A and SW-C can be used equivalently for determination of stroke volume, peak flow, and vessel area. Irrespective of the applied software and scanner, high intra- and interreader variability for all parameters have to be taken into account before introducing 4D Flow CMR in clinical routine. Especially in multicenter clinical trials a single image evaluation software should be applied.


Assuntos
Imageamento por Ressonância Magnética , Software , Humanos , Feminino , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Aorta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA