Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Med Biol Eng Comput ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38954265

RESUMO

Diastolic vortex ring (VR) plays a key role in the blood-pumping function exerted by the left ventricle (LV), with altered VR structures being associated with LV dysfunction. Herein, we sought to characterize the VR diastolic alterations in ischemic cardiomyopathy (ICM) patients with systo-diastolic LV dysfunction, as compared to healthy controls, in order to provide a more comprehensive understanding of LV diastolic function. 4D Flow MRI data were acquired in ICM patients (n = 15) and healthy controls (n = 15). The λ2 method was used to extract VRs during early and late diastolic filling. Geometrical VR features, e.g., circularity index (CI), orientation (α), and inclination with respect to the LV outflow tract (ß), were extracted. Kinetic energy (KE), rate of viscous energy loss ( EL ˙ ), vorticity (W), and volume (V) were computed for each VR; the ratios with the respective quantities computed for the entire LV were derived. At peak E-wave, the VR was less circular (p = 0.032), formed a smaller α with the LV long-axis (p = 0.003) and a greater ß (p = 0.002) in ICM patients as compared to controls. At peak A-wave, CI was significantly increased (p = 0.034), while α was significantly smaller (p = 0.016) and ß was significantly increased (p = 0.036) in ICM as compared to controls. At both peak E-wave and peak A-wave, EL ˙ VR / EL ˙ LV , WVR/WLV, and VVR/VLV significantly decreased in ICM patients vs. healthy controls. KEVR/VVR showed a significant decrease in ICM patients with respect to controls at peak E-wave, while VVR remained comparable between normal and pathologic conditions. In the analyzed ICM patients, the diastolic VRs showed alterations in terms of geometry and energetics. These derangements might be attributed to both structural and functional alterations affecting the infarcted wall region and the remote myocardium.

2.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710782

RESUMO

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/métodos , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada por Raios X , Aorta/diagnóstico por imagem , Aorta/cirurgia , Resultado do Tratamento , Próteses Valvulares Cardíacas , Estudos Retrospectivos
4.
Catheter Cardiovasc Interv ; 103(5): 741-750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38451154

RESUMO

BACKGROUND: The GCA is a well performing device in terms of efficacy despite complex anatomies (aortic rim <5 mm and ASD diameter >17 mm) with a good safety profile. AIMS: To evaluate atrial septal defect (ASD) features impacting on right disc device thrombosis in patients who underwent Gore Cardioform ASD Occluder (GCA) implantation. METHODS: A total of 44 consecutive patients undergoing percutaneous ASD with GCA device from January 2020 to September 2022 at our tertiary care Center were evaluated. The minimum follow-up was 6 months. RESULTS: The patients were stratified in two groups according to a cut-off value of ASD diameter equal to 20 mm at sizing balloon, derived from ROC analysis (AUC = 0.894; p = 0.024). Baseline characteristics were comparable between groups in terms of age, sex, weight, height, and interatrial septum dimensions. Patients with ASD > 20 mm (n = 9) had a higher ASD/device dimension ratio, both at echocardiography (p = 0.009) and at sizing balloon (p = 0.001), longer fluoroscopic time (p = 0.022), and higher incidence of device thrombosis (0.006). Right disc thrombosis was observed in three patients of the ASD > 20 mm group, always in the inferior portion of the right disc. On univariate analysis, ASD diameter at sizing balloon (OR 1.360; p = 0.036) was the only positive predictor of device thrombosis. CONCLUSIONS: Right disc thrombosis of the GCA device may be under-recognized at follow-up, hence deserving clinical attention, especially in those patients with larger ASD diameters.


Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Ecocardiografia Transesofagiana , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/terapia
5.
JACC Case Rep ; 29(6): 102247, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38549848

RESUMO

We describe a rare and extremely challenging case of transcatheter pulmonary valve implantation in repaired tetralogy of Fallot and anomalous origin of the left main coronary artery from the right coronary sinus. Procedural planning based on advanced multimodality imaging and 3-dimensional technology proved to be the key to procedural success.

6.
Heart ; 110(4): 235-244, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37487694

RESUMO

Although survival has significantly improved in the last four decades, the diagnosis of Ebstein's anomaly is still associated with a 20-fold increased risk of mortality, which generally drops after neonatal period and increases subtly thereafter. With increasing age of presentation, appropriate timing of intervention is challenged by a wide spectrum of disease and paucity of data on patient-tailored interventional strategies. The present review sought to shed light on the wide grey zone of post-neonatal Ebstein's manifestations, highlighting current gaps and achievements in knowledge for adequate risk assessment and appropriate therapeutic strategy.A 'wait-and-see' approach has been adopted in many circumstances, though its efficacy is now questioned by the awareness that Ebstein's anomaly is not a benign disease, even when asymptomatic. Moreover, older age at intervention showed a negative impact on post-surgical outcome.In order to tackle the extreme heterogeneity of Ebstein's anomaly, this review displays the multimodality imaging assessment necessary for a proper anatomical classification and the multidisciplinary approach needed for a comprehensive risk stratification and monitoring strategy. Currently available predictors of clinical outcome are summarised for both operated and unoperated patients, with the aim of supporting the decisional process on the choice of appropriate therapy and optimal timing for intervention.


Assuntos
Anomalia de Ebstein , Recém-Nascido , Criança , Adulto , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/cirurgia , Medição de Risco , Imagem Multimodal
8.
Comput Biol Med ; 163: 107147, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37329622

RESUMO

Accurate planning of transcatheter aortic valve implantation (TAVI) is important to minimize complications, and it requires anatomic evaluation of the aortic root (AR), commonly performed through 3D computed tomography (CT) image analysis. Currently, there is no standard automated solution for this process. Two convolutional neural networks with 3D U-Net architectures (model 1 and model 2) were trained on 310 CT scans for AR analysis. Model 1 performs AR segmentation and model 2 identifies the aortic annulus and sinotubular junction (STJ) contours. After training, the two models were integrated into a fully automated pipeline for geometric analysis of the AR. Results were validated against manual measurements of 178 TAVI candidates. The trained CNNs segmented the AR, annulus, and STJ effectively, resulting in mean Dice scores of 0.93 for the AR, and mean surface distances of 0.73 mm and 0.99 mm for the annulus and STJ, respectively. Automatic measurements were in good agreement with manual annotations, yielding annulus diameters that differed by 0.52 [-2.96, 4.00] mm (bias and 95% limits of agreement for manual minus algorithm). Evaluating the area-derived diameter, bias, and limits of agreement were 0.07 [-0.25, 0.39] mm. STJ and sinuses diameters computed by the automatic method yielded differences of 0.16 [-2.03, 2.34] and 0.1 [-2.93, 3.13] mm, respectively. The proposed tool is a fully automatic solution to quantify morphological biomarkers for pre-TAVI planning. The method was validated against manual annotation from clinical experts and showed to be quick and effective in assessing AR anatomy, with potential for time and cost savings.


Assuntos
Estenose da Valva Aórtica , Aprendizado Profundo , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Aorta Torácica , Tomografia Computadorizada por Raios X/métodos
9.
Front Cardiovasc Med ; 10: 1103751, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025678

RESUMO

The total kinetic energy (KE) of blood can be decomposed into mean KE (MKE) and turbulent KE (TKE), which are associated with the phase-averaged fluid velocity field and the instantaneous velocity fluctuations, respectively. The aim of this study was to explore the effects of pharmacologically induced stress on MKE and TKE in the left ventricle (LV) in a cohort of healthy volunteers. 4D Flow MRI data were acquired in eleven subjects at rest and after dobutamine infusion, at a heart rate that was ∼60% higher than the one in rest conditions. MKE and TKE were computed as volume integrals over the whole LV and as data mapped to functional LV flow components, i.e., direct flow, retained inflow, delayed ejection flow and residual volume. Diastolic MKE and TKE increased under stress, in particular at peak early filling and peak atrial contraction. Augmented LV inotropy and cardiac frequency also caused an increase in direct flow and retained inflow MKE and TKE. However, the TKE/KE ratio remained comparable between rest and stress conditions, suggesting that LV intracavitary fluid dynamics can adapt to stress conditions without altering the TKE to KE balance of the normal left ventricle at rest.

10.
J Clin Med ; 12(1)2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36615133

RESUMO

Post-ischemic left ventricular (LV) remodeling is a biologically complex process involving myocardial structure, LV shape, and function, beginning early after myocardial infarction (MI) and lasting until 1 year. Adverse remodeling is a post-MI maladaptive process that has been associated with long-term poor clinical outcomes. Cardiac Magnetic Resonance (CMR) is the best tool to define adverse remodeling because of its ability to accurately measure LV end-diastolic and end-systolic volumes and their variation over time and to characterize the underlying myocardial changes. Therefore, CMR is the gold standard method to assess in vivo myocardial infarction extension and to detect the presence of microvascular obstruction and intramyocardial hemorrhage, both associated with adverse remodeling. In recent times, new CMR quantitative biomarkers emerged as predictive of post-ischemic adverse remodeling, such as T1 mapping, myocardial strain, and 4D flow. Additionally, CMR T1 mapping imaging may depict infarcted tissue and assess diffuse myocardial fibrosis by using surrogate markers such as extracellular volume fraction, which may predict functional recovery or risk stratification of remodeling. Finally, there is emerging evidence supporting the utility of intracavitary blood flow kinetic energy and hemodynamic features assessed by the 4D flow CMR technique as early predictors of remodeling.

11.
J Endovasc Ther ; 30(5): 756-768, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35588222

RESUMO

PURPOSE: Displacement forces (DFs) identify hostile landing zones for stent graft deployment in thoracic endovascular aortic repair (TEVAR). However, their use in TEVAR planning is hampered by the need for time-expensive computational fluid dynamics (CFD). We propose a novel fast-approximate computation of DFs merely exploiting aortic arch anatomy, as derived from the computed tomography (CT) and a measure of central aortic pressure. MATERIALS AND METHODS: We tested the fast-approximate approach against CFD gold-standard in 34 subjects with the "bovine" aortic arch variant. For each dataset, a 3-dimensional (3D) model of the aortic arch lumen was reconstructed from computed tomography angiography and CFD then employed to compute DFs within the aortic proximal landing zones. To quantify fast-approximate DFs, the wall shear stress contribution to the DF was neglected and blood pressure space-distribution was averaged on the entire aortic wall to reliably approximate the patient-specific central blood pressure. Also, DF values were normalized on the corresponding proximal landing zone area to obtain the equivalent surface traction (EST). RESULTS: Fast-approximate approach consistently reflected (r2=0.99, p<0.0001) the DF pattern obtained by CFD, with a -1.1% and 0.7° bias in DFs magnitude and orientation, respectively. The normalized EST progressively increased (p<0.0001) from zone 0 to zone 3 regardless of the type of arch, with proximal landing zone 3 showing significantly greater forces than zone 2 (p<0.0001). Upon DF normalization to the corresponding aortic surface, fast-approximate EST was decoupled in blood pressure and a dimensionless shape vector (S) reflecting aortic arch morphology. S showed a zone-specific pattern of orientation and proved a valid biomechanical blueprint of DF impact on the thoracic aortic wall. CONCLUSION: Requiring only a few seconds and quantifying clinically relevant biomechanical parameters of proximal landing zones for arch TEVAR, our method suits the real preoperative decision-making process. It paves the way toward analyzing large population of patients and hence to define threshold values for a future patient-specific preoperative TEVAR planning.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Stents
12.
J Thorac Cardiovasc Surg ; 165(4): 1418-1429.e4, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-33781593

RESUMO

OBJECTIVE: The study objective was to elucidate the mechanisms of left ventricle functional recovery in terms of endocardial contractility and synchronicity after surgical ventricular reconstruction. METHODS: Real-time 3-dimensional transthoracic echocardiography was performed on 20 patients with anterior left ventricle remodeling and ischemic heart failure before surgical ventricular reconstruction and at 6-month follow-up, and on 15 healthy controls matched by age and body surface area. Real-time 3-dimensional transthoracic echocardiography datasets were analyzed through TomTec software (4D LV-Analysis; TomTec Imaging Systems GmbH, Unterschleissheim, Germany): Left ventricle volumes, ejection fraction, and global longitudinal strain were computed; the time-dependent endocardial surface yielded by 3-dimensional speckle-tracking echocardiography was postprocessed through in-house software to quantify local systolic minimum principal strain as a measure of fiber shortening and mechanical dispersion as a measure of fiber synchronicity. RESULTS: Compared with controls, patients with heart failure before surgical ventricular reconstruction showed lower ejection fraction (P < .0001) and significantly impaired mechanical dispersion (P < .0001) and minimum principal strain (P < .0001); the latter worsened progressively from left ventricle base to apex. After surgical ventricular reconstruction, global longitudinal strain improved from -6.7% to -11.3% (P < .0001); mechanical dispersion decreased in every left ventricle region (P ≤ .017) and mostly in the basal region, where computed mechanical dispersion values were comparable to physiologic values (P ≥ .046); minimum principal strain improved mostly in the basal region, changing from -16.6% to -22.3% (P = .0027). CONCLUSIONS: At 6-month follow-up, surgical ventricular reconstruction was associated with significant recovery in global left ventricle function, improved mechanical dispersion indicating a more synchronous left ventricle contraction, and improved left ventricle fiber shortening mostly in the basal region, suggesting the major role of the remote myocardium in enhancing left ventricle functional recovery.


Assuntos
Ecocardiografia Tridimensional , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda/fisiologia , Ecocardiografia/métodos , Ecocardiografia Tridimensional/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Volume Sistólico/fisiologia , Reprodutibilidade dos Testes
13.
Quant Imaging Med Surg ; 12(7): 3515-3527, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35782271

RESUMO

Background: Performance and durability of arterio-venous grafts depend on their ability to mimic the mechanical behavior of the anastomized blood vessels. To select the most suitable synthetic graft, in vivo evaluation of the radial deformability of peripheral arteries and veins could be crucial; however, a standardized non-invasive strategy is still missing. Herein, we sought to define a novel and user-friendly clinical protocol for in vivo assessment of the arm vessel deformability. Methods: A dedicated protocol, applied on 30 volunteers, was specifically designed to estimate both compliance and distensibility of the brachial and radial arteries, and of the basilic and cephalic veins. Bi-dimensional ultrasound imaging was used to acquire cross-sectional areas (CSAs) of arteries in clinostatic configuration, and CSAs of veins combining clinostatic and orthostatic configurations. Arterial pulse pressure was measured with a digital sphygmomanometer, while venous hydrostatic pressure was derived from the arm length in orthostatic configuration. Results: For each participant, all CSAs were successfully extracted from ultrasound images. The basilic vein and the radial artery exhibited the largest (21.5±8.9 mm2) and the smallest (3.4±1.0 mm2) CSAs, respectively; CSA measurements were highly repeatable (Bland-Altman bias <10% and Pearson correlation ≥0.90, for both arteries and veins). In veins, compliance and distensibility were higher than in arteries; compliance was significantly higher (P<0.0001) in the brachial than in the radial artery (3.52×10-4 vs. 1.3×10-4 cm2/mmHg); it was three times larger in basilic veins than in cephalic veins (17.4×10-4 vs. 5.6×10-4 cm2/mmHg, P<0.0001). Conclusions: The proposed non-invasive protocol proved feasible, effective and adequate for daily clinical practice, allowing for the estimation of patient-specific compliance and distensibility of peripheral arteries and veins. If further extended, it may contribute to the fabrication of biohybrid arterio-venous grafts, paving the way towards patient-tailored solutions for vascular access.

14.
Int J Cardiol ; 362: 183-189, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35504452

RESUMO

BACKGROUND: Left atrial (LA) function can be effectively assessed by measuring longitudinal LA strain (LAS) via two-dimensional speckle tracking echocardiography (2DSTE). Here, we test 2DSTE-based LAS as marker of different left ventricle (LV) remodeling patterns and as prognostic index in ischemic heart failure (HF) candidates to surgical ventricular reconstruction. METHODS: We retrospectively considered ischemic HF patients with anterior (group A, n=130) or posterior (group P, n=48) LV remodeling. Based on 2D ultrasound, LV and LA morpho-functional parameters were quantified including reservoir (LASRes), conduit (LASCond) and booster (LASBoost) LAS. We tested their capability to discriminate between groups A and P, and their group-specific prognostic significance for the composite end-point of death or HF re-hospitalization at follow-up (mean follow-up time=40 months, range 3-101 months). RESULTS: Group A and group P displayed similar end-diastolic (p=0.89) and end-systolic (p=0.33) LV volume index, and LA volume index LAVi (p=0.44) corrected for the degree of mitral regurgitation. As compared to group P, group A revealed a significant reduction in LASBoost (9.2±0.4% vs. 11.1±0.7%, p=0.04) and a non-significant reduction in LASRes (16.9±0.7% vs. 19.3±1.1%, p=0.06). Kaplan-Meier curves showed that the median LASRes and LASBoost values effectively stratified patients based on their prognosis in the overall study population (Log-rank p=0.002 and Log_rank p<0.0001) and in group A, where the association was stronger for LASBoost (Log-rank p<0.001) than for LASRes (Log-rank p=0.013). CONCLUSIONS: 2DSTE-based LAS assessment is affordable, repeatable and non-invasive, and could add clinically-relevant mechanistic insight and prognostic value in the stratification of ischemic HF patients.


Assuntos
Átrios do Coração , Insuficiência Cardíaca , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Prognóstico , Estudos Retrospectivos , Ultrassonografia , Remodelação Ventricular
15.
Eur Heart J ; 43(28): 2672-2684, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35608227

RESUMO

Congenital heart disease (CHD) is often comprised of complex three-dimensional (3D) anatomy that must be well understood to assess the pathophysiological consequences and guide therapy. Thus, detailed cardiac imaging for early detection and planning of interventional and/or surgical treatment is paramount. Advanced technologies have revolutionized diagnostic and therapeutic practice in CHD, thus playing an increasing role in its management. Traditional reliance on standard imaging modalities including echocardiography, cardiac computed tomography (CT) and magnetic resonance imaging (MRI) has been augmented by the use of recent technologies such as 3D printing, virtual reality, augmented reality, computational modelling, and artificial intelligence because of insufficient information available with these standard imaging techniques. This has created potential opportunities of incorporating these technologies into routine clinical practice to achieve the best outcomes through delivery of personalized medicine. In this review, we provide an overview of these evolving technologies and a new approach enabling physicians to better understand their real-world application in adult CHD as a prelude to clinical workflow implementation.


Assuntos
Cardiopatias Congênitas , Realidade Virtual , Adulto , Inteligência Artificial , Coração , Cardiopatias Congênitas/cirurgia , Humanos , Impressão Tridimensional
16.
J Med Eng Technol ; 46(3): 209-219, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35060819

RESUMO

We investigated the effect of the design of bioprosthetic pericardial valves on the downstream fluid flow pattern through four-dimensional flow magnetic resonance imaging (4D Flow). A dedicated in vitro test bench, including a paradigmatic aortic root phantom, was used to compare, under steady flow conditions, three commercially used pericardial bioprostheses (TrifectaTM, Carpentier-Edwards PERIMOUNT Magna, Crown PRT®), selecting the two smallest and comparable valve sizes. In-house 4D Flow post-processing provided the downstream flow pattern of velocity, the velocity profile at vena contracta, its effective orifice area (EOA) and the corresponding hydraulic diameter (DH). Trifecta reported the lowest peak of velocity for both the tested sizes, with vena contracta position being the most proximal to the free margin of leaflets. Conversely, in both Crown and Magna, jet flow continued to increase its downstream velocity, resulting in a farther position of vena contracta. EOA shape was trilobal for Magna, triangular for Crown and circular for Trifecta, the last one maximising EOA. The percentage of nominal luminal area effectively exploited by the flow was largely above 80% in Trifecta, below 75% in Crown and below 70% in Magna. Hence, the design of pericardial bioprostheses directly impacts on the downstream flow field pattern and its fluid dynamic performance.


Assuntos
Próteses Valvulares Cardíacas , Valva Aórtica , Hemodinâmica , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Desenho de Prótese
17.
J Magn Reson Imaging ; 56(4): 1157-1170, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35075711

RESUMO

BACKGROUND: Time-resolved three-directional velocity-encoded (4D flow) magnetic resonance imaging (MRI) enables the quantification of left ventricular (LV) intracavitary fluid dynamics and energetics, providing mechanistic insight into LV dysfunctions. Before becoming a support to diagnosis and patient stratification, this analysis should prove capable of discriminating between clearly different LV derangements. PURPOSE: To investigate the potential of 4D flow in identifying fluid dynamic and energetics derangements in ischemic and restrictive LV cardiomyopathies. STUDY TYPE: Prospective observational study. POPULATION: Ten patients with post-ischemic cardiomyopathy (ICM), 10 patients with cardiac light-chain cardiac amyloidosis (AL-CA), and 10 healthy controls were included. FIELD STRENGTH/SEQUENCE: 1.5 T/balanced steady-state free precession cine and 4D flow sequences. ASSESSMENT: Flow was divided into four components: direct flow (DF), retained inflow, delayed ejection flow, and residual volume (RV). Demographics, LV morphology, flow components, global and regional energetics (volume-normalized kinetic energy [KEV ] and viscous energy loss [ELV ]), and pressure-derived hemodynamic force (HDF) were compared between the three groups. STATISTICAL TESTS: Intergroup differences in flow components were tested by one-way analysis of variance (ANOVA); differences in energetic variables and peak HDF were tested by two-way ANOVA. A P-value of <0.05 was considered significant. RESULTS: ICM patients exhibited the following statistically significant alterations vs. controls: reduced KEV , mostly in the basal region, in systole (-44%) and in diastole (-37%); altered flow components, with reduced DF (-33%) and increased RV (+26%); and reduced basal-apical HDF component on average by 63% at peak systole. AL-CA patients exhibited the following alterations vs. controls: significantly reduced KEV at the E-wave peak in the basal segment (-34%); albeit nonstatistically significant, increased peaks and altered time-course of the HDF basal-apical component in diastole and slightly reduced HDF components in systole. DATA CONCLUSION: The analysis of multiple 4D flow-derived parameters highlighted fluid dynamic alterations associated with systolic and diastolic dysfunctions in ICM and AL-CA patients, respectively. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Cardiomiopatia Restritiva , Hidrodinâmica , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Função Ventricular Esquerda
18.
J Digit Imaging ; 35(2): 226-239, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35083618

RESUMO

Feasibility assessment and planning of thoracic endovascular aortic repair (TEVAR) require computed tomography (CT)-based analysis of geometric aortic features to identify adequate landing zones (LZs) for endograft deployment. However, no consensus exists on how to take the necessary measurements from CT image data. We trained and applied a fully automated pipeline embedding a convolutional neural network (CNN), which feeds on 3D CT images to automatically segment the thoracic aorta, detects proximal landing zones (PLZs), and quantifies geometric features that are relevant for TEVAR planning. For 465 CT scans, the thoracic aorta and pulmonary arteries were manually segmented; 395 randomly selected scans with the corresponding ground truth segmentations were used to train a CNN with a 3D U-Net architecture. The remaining 70 scans were used for testing. The trained CNN was embedded within computational geometry processing pipeline which provides aortic metrics of interest for TEVAR planning. The resulting metrics included aortic arch centerline radius of curvature, proximal landing zones (PLZs) maximum diameters, angulation, and tortuosity. These parameters were statistically analyzed to compare standard arches vs. arches with a common origin of the innominate and left carotid artery (CILCA). The trained CNN yielded a mean Dice score of 0.95 and was able to generalize to 9 pathological cases of thoracic aortic aneurysm, providing accurate segmentations. CILCA arches were characterized by significantly greater angulation (p = 0.015) and tortuosity (p = 0.048) in PLZ 3 vs. standard arches. For both arch configurations, comparisons among PLZs revealed statistically significant differences in maximum zone diameters (p < 0.0001), angulation (p < 0.0001), and tortuosity (p < 0.0001). Our tool allows clinicians to obtain objective and repeatable PLZs mapping, and a range of automatically derived complex aortic metrics.


Assuntos
Implante de Prótese Vascular , Aprendizado Profundo , Procedimentos Endovasculares , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aortografia/métodos , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Int J Cardiovasc Imaging ; 38(1): 211-221, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34448067

RESUMO

To assess the impact of regurgitant jet direction on left ventricular function and intraventricular hemodynamics in asymptomatic patients with bicuspid aortic valve (BAV) and mild aortic valve regurgitation (AR), using cardiac magnetic resonance (CMR) feature tracking and 4D flow imaging. Fifty BAV individuals were retrospectively selected: 15 with mild AR and posterior regurgitation jet (Group-PJ), 15 with regurgitant jet in other directions (Group-nPJ) and 20 with no regurgitation (Controls). CMR protocol included cine steady state free precession (SSFP) sequences and 4D Flow imaging covering the entire left ventricle (LV) cavity and the aortic root. Cine-SSFP images were analyzed to assess LV volumes, longitudinal and circumferential myocardial strain. Circumferential and longitudinal peak diastolic strain rate (PDSR) and peak diastolic velocity (PDV) were reduced in group PJ if compared to group nPJ and control group (PDSR = 1.10 ± 0.2 1/s vs. 1.34 ± 0.5 1/s vs. 1.53 ± 0.3 1/s, p:0.001 and 0.68 ± 0.2 1/s vs. 1.17 ± 0.2 1/s vs. 1.05 ± 0.4 1/s ; p < 0.001, PDV = - 101.6 ± 28.1 deg/s vs. - 201.4 ± 85.9 deg/s vs. - 221.6 ± 67.1 deg/s; p < 0.001 and - 28.1 ± 8 mm/s vs. - 38.9 ± 11.1 mm/s vs. - 43.6 ± 14.3 mm/s, p < 0.001, respectively), whereas no differences have been found in systolic strain values. 4D Flow images (available only in 9 patients) showed deformation of diastolic transmitral streamlines direction in group PJ compared to other groups. In BAV patients with mild AR, the posterior direction of the regurgitant jet may hamper the complete mitral valve opening, disturbing transmitral flow and slowing the LV diastolic filling.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Insuficiência da Valva Mitral , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Humanos , Espectroscopia de Ressonância Magnética , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Valor Preditivo dos Testes , Estudos Retrospectivos
20.
Front Cardiovasc Med ; 9: 1076359, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36704466

RESUMO

An 8-year-old girl, diagnosed with mid-aortic syndrome (MAS) at the age of 2 months and under antihypertensive therapy, presented with severe systemic hypertension (>200/120 mmHg). Computed tomography (CT) examination revealed aortic aneurysm between severe stenoses at pre- and infra-renal segments, and occlusion of principal splanchnic arteries with peripheral collateral revascularization. Based on CT imaging, preoperative three-dimensional (3D) anatomy was reconstructed to assess aortic dimensions and a dedicated in vitro planning platform was designed to investigate the feasibility of a stenting procedure under fluoroscopic guidance. The in vitro system was designed to incorporate a translucent flexible 3D-printed patient-specific model filled with saline. A covered 8-zig 45-mm-long Cheatham-Platinum (CP) stent and a bare 8-zig, 34-mm-long CP stent were implanted with partial overlap to treat the stenoses (global peak-to-peak pressure gradient > 60 mmHg), excluding the aneurysm and avoiding risk of renal arteries occlusion. Percutaneous procedure was successfully performed with no residual pressure gradient and exactly replicating the strategy tested in vitro. Also, as investigated on the 3D-printed model, additional angioplasty was feasible across the frames of the stent to improve bilateral renal flow. Postoperative systemic pressure significantly reduced (130/70 mmHg) as well as dosage of antihypertensive therapy. This is the first report demonstrating the use of a 3D-printed model to effectively plan percutaneous intervention in a complex pediatric MAS case: taking full advantage of the combined use of a patient-specific 3D model and a dedicated in vitro platform, feasibility of the stenting procedure was successfully tested during pre-procedural assessment. Hence, use of patient-specific 3D-printed models and in vitro dedicated platforms is encouraged to assist pre-procedural planning and personalize treatment, thus enhancing intervention success.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA